58 resultados para Assay Development


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Zootecnia - FCAV

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this work for evaluating the potential of biogas and methane productions and still and reductions in levels of total solids (TS), volatile solids (VS) and neutral detergent fiber (NDF) of the co-digestion anaerobic digestion in digesters fed with swine manure plus disposal of oil and lyophilized microorganisms. For assay development substrates were prepared containing 4% TS, consisting of swine manure, disposal oil (the proportions 8, 10 and 12% oil content in relation to the substrate TS), lyophilized microorganisms (Biol-2000 ® - concentrations of 10 g/m3 and 15 g/m3 ), water for dilution of this waste and inoculum for batch digesters supply. There was no significant difference with respect to reductions in TS, VS and NDF constituents, providing very significant reductions in average 54.14; 62.79 and 49.16% respectively. Regarding the potential of biogas production, the highest yields occurred in digesters supplied with 10% oil and 15 g/m3 of Biol®, being 0.43 and 0.54 L of biogas per kg of TS and VS added, respectively, similar results were found when assessed the potential for methane production, with higher values (0.22 and 0.27 L of methane per kg of TS added and VS, respectively) obitidos the same treatment. The inclusion of 15 g/m3 in Biol® substrate composition containing swine manure and 10% of oil improves the yields of biogas and methane.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A Saccharomyces cerevisiae-expressed nucleocapsid (N) polypeptide of the M41 strain of infectious bronchitis virus (IBV) was used as antigen in a recombinant yeast-expressed N protein-based enzyme-linked immunosorbent assay (Y-N-ELISA). The Y-N-ELISA was rapid, sensitive, and specific for detecting chicken serum antibodies to IBV, and it compared favorably with a commercial ELISA.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A crude antigenic preparation of Babesia bigemina was used to develop an ELISA for the detection of IgM antibodies. Optimal dilutions of the antigen, using positive and negative reference sera, were determined by checkerboard titrations. Negative sera from cattle imported from tick-free areas, serum samples collected from infected B. bigemina cattle were used to validate the test. The specificity was 94% and sensitivity of the Elisa 87.5%. Sera from 385 cattle deriving from areas free from tick-borne diseases, which were submitted to a preimmunization process, were screened by this technique. The Elisa detected seroconversion on the 14th day post-inoculation in animals either infested with Boophilus microplus ticks (infected with B. bigemina), or inoculated with B. bigemina infected blood. Antibody titers decreased after day 33; however, all animals remained positive until the end of the experiment (124 days). The ELISA described may prove to be an appropriate serological test for the detection of IgM antibodies against B. bigemina.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Two experiments were carried out to evaluate a larval development assay for the detection of anthelmintic resistance in O. circumcincta. In Experiment I, the dose responses to levamisole (LEV), thiabendazole (TBZ) and ivermectin (IVM) of 8 isolates of O. circumcincta were measured 34 days after infection (DAI). Four of these isolates were shown to be resistant to 1 or more anthelmintics. With 2 exceptions, all isolates considered to be resistant had higher LD50 values than the susceptible isolates for that anthelmintic. One exception was isolate RM8, which was considered to be resistant to all 3 anthelmintics based on faecal egg count reduction tests in goats, but the LD50 value for LEV did not differ from that for the susceptible isolates. The other exception was an isolate considered to be susceptible to TBZ which had a relatively high LD50 value. In an unrelated trial that was prompted by this finding, this isolate was confirmed to be benzimidazole-resistant. Isolate RM8 and an isolate susceptible to all 3 anthelmintics (SK2) were used in the second experiment, which was conducted to monitor changes in the LD50 values of LEV, TBZ and IVM over time following a single infection of 35 000 infective larvae in young sheep. Faecal samples were collected weekly from 24 to 115 DAI. With all 3 anthelmintics, the LD50 values increased with time to a peak around 50-60 DAI, and then declined to levels similar to those observed soon after patency. This trend was consistent for both isolates. The highest mean LD50 values for isolates SK2 for IVM and TBZ and RM8 for IVM and RM8, respectively, were 1.7 and 1.8 times, and 2.2 and 2.9 times higher than the initial mean LD50 values. There was a clear distinction in LD50 values between isolates at each sampling day for both IVM and TBZ. However, as a consequence of the changes in LD50 values with time, the peak LD50 values of IVM for isolate SK2 were higher than the minimum LD50 values of isolate RM8. As there was no apparent difference in LEV efficacy between these 2 isolates, the data were pooled. The highest mean LD50 value was 2.3 times higher than the initial LD50 value. (C) 1997 Australian Society for Parasitology.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Orbifloxacin is a fluoroquinolone with broad-spectrum antimicrobial activity, and belongs to the third generation of quinolones. Regarding the quality control of medicines, a validated microbiological assay for determination of orbifloxacin in pharmaceutical formulations has not as yet been reported. For this purpose, this paper reports the development and validation of a simple, sensitive, accurate and reproducible agar diffusion method to quantify orbifloxacin in tablet formulations. The assay is based on the inhibitory effect of orbifloxacin upon the strain of Staphylococcus aureus ATCC 25923 used as test microorganism. The results were treated statistically by analysis of variance and were found to be linear (r = 0.9992) in the selected range of 16.0-64.0 μg/mL, precise with relative standard deviation (RSD) of repeatability intraday = 2.88%, intermediate precision RSD = 3.33%, and accurate (100.31%). The results demonstrated the validity of the proposed bioassay, which allows reliable orbifloxacin quantitation in pharmaceutical samples and therefore can be used as a useful alternative methodology for the routine quality control of this medicine. © 2011 by the authors; licensee MDPI, Basel, Switzerland.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Ceftriaxone sodium is a cephalosporin with broad-spectrum antimicrobial activity and belongs to the third generation of cephalosporins. Regarding the quality control of medicines, a validated microbiological assay for the determination of ceftriaxone sodium in powder for injectable solution has not been reported yet. This paper reports the development and validation of a simple, accurate and reproducible agar diffusion method to quantify ceftriaxone sodium in powder for injectable solution. The assay is based on the inhibitory effect of ceftriaxone sodium on the strain of Bacillus subtilis ATCC 9371 IAL 1027 used as test microorganism. The results were treated statistically by analysis of variance and were found to be linear (r = 0.999) in the selected range of 15.0-60.0 μg/mL, precise with a relative standard deviation (RSD) of repeatability intraday = 1.40%, accurate (100.46%) and robust with a RSD lower than 1.28%. The results demonstrated the validity of the proposed bioassay, which allows reliable ceftriaxone sodium quantitation in pharmaceutical samples and therefore can be used as a useful alternative methodology for the routine quality control of this medicine. © 2012 by the authors; licensee MDPI, Basel, Switzerland.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mitochondrial DNA (mtDNA) analysis is usually a last resort in routine forensic DNA casework. However, it has become a powerful tool for the analysis of highly degraded samples or samples containing too little or no nuclear DNA, such as old bones and hair shafts. The gold standard methodology still constitutes the direct sequencing of polymerase chain reaction (PCR) products or cloned amplicons from the HVS-1 and HVS-2 (hypervariable segment) control region segments. Identifications using mtDNA are time consuming, expensive and can be very complex, depending on the amount and nature of the material being tested. The main goal of this work is to develop a less labour-intensive and less expensive screening method for mtDNA analysis, in order to aid in the exclusion of non-matching samples and as a presumptive test prior to final confirmatory DNA sequencing. We have selected 14 highly discriminatory single nucleotide polymorphisms (SNPs) based on simulations performed by Salas and Amigo (2010) [1] to be typed using SNaPShotTM (Applied Biosystems, Foster City, CA, USA). The assay was validated by typing more than 100 HVS-1/HVS-2 sequenced samples. No differences were observed between the SNP typing and DNA sequencing when results were compared, with the exception of allelic dropouts observed in a few haplotypes. Haplotype diversity simulations were performed using 172 mtDNA sequences representative of the Brazilian population and a score of 0.9794 was obtained when the 14 SNPs were used, showing that the theoretical prediction approach for the selection of highly discriminatory SNPs suggested by Salas and Amigo (2010) [1] was confirmed in the population studied. As the main goal of the work is to develop a screening assay to skip the sequencing of all samples in a particular case, a pair-wise comparison of the sequences was done using the selected SNPs. When both HVS-1/HVS-2 SNPs were used for simulations, at least two differences were observed in 93.2% of the comparisons performed. The assay was validated with casework samples. Results show that the method is straightforward and can be used for exclusionary purposes, saving time and laboratory resources. The assay confirms the theoretic prediction suggested by Salas and Amigo (2010) [1]. All forensic advantages, such as high sensitivity and power of discrimination, as also the disadvantages, such as the occurrence of allele dropouts, are discussed throughout the article. © 2013 Elsevier B.V.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)