89 resultados para 802.15.4
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Faced with an imminent restructuring of the electric power system, over the past few years many countries have invested in a new paradigm known as Smart Grid. This paradigm targets optimization and automation of electric power network, using advanced information and communication technologies. Among the main communication protocols for Smart Grids we have the DNP3 protocol, which provides secure data transmission with moderate rates. The IEEE 802.15.4 is another communication protocol also widely used in Smart Grid, especially in the so-called Home Area Network (HAN). Thus, many applications of Smart Grid depends on the interaction of these two protocols. This paper proposes modeling, in the traditional network simulator NS-2, the integration of DNP3 protocol and the IEEE 802.15.4 wireless standard for low cost simulations of Smart Grid applications.
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
In this paper was proposed the development of an heterogeneous system using the microcontroller (AT90CANI28) where the protocol model CAN and the standard IEEE 802.15.4 are connected. This module is able to manage and monitor sensors and actuators using CAN and, through the wireless standard 802.15.4, communicate with the other network modules. © 2011 IEEE.
Resumo:
Wireless Sensor Networks (WSNs) can be used to monitor hazardous and inaccessible areas. In these situations, the power supply (e.g. battery) of each node cannot be easily replaced. One solution to deal with the limited capacity of current power supplies is to deploy a large number of sensor nodes, since the lifetime and dependability of the network will increase through cooperation among nodes. Applications on WSN may also have other concerns, such as meeting temporal deadlines on message transmissions and maximizing the quality of information. Data fusion is a well-known technique that can be useful for the enhancement of data quality and for the maximization of WSN lifetime. In this paper, we propose an approach that allows the implementation of parallel data fusion techniques in IEEE 802.15.4 networks. One of the main advantages of the proposed approach is that it enables a trade-off between different user-defined metrics through the use of a genetic machine learning algorithm. Simulations and field experiments performed in different communication scenarios highlight significant improvements when compared with, for instance, the Gur Game approach or the implementation of conventional periodic communication techniques over IEEE 802.15.4 networks. © 2013 Elsevier B.V. All rights reserved.
Resumo:
The Internet of Things is a new paradigm where smart embedded devices and systems are connected to the Internet. In this context, Wireless Sensor Networks (WSN) are becoming an important alternative for sensing and actuating critical applications like industrial automation, remote patient monitoring and domotics. The IEEE 802.15.4 protocol has been adopted as a standard for WSN and the 6LoWPAN protocol has been proposed to overcome the challenges of integrating WSN and Internet protocols. In this paper, the mechanisms of header compression and fragmentation of IPv6 datagrams proposed in the 6LoWPAN standard were evaluated through field experiments using a gateway prototype and IEEE 802.15.4 nodes.
Resumo:
4-Dimethylaminocinnamylidenepyruvic acid (H-DMCP)and its sodium salt (Na-DMCP) have been synthesized and characterized. The protonation constant of DMCP as well as the stability constants of its binary 1:1 complexes with trivalent lanthanides (except Pm), Yttrium(III), Scandium(III), Thorium(IV) and Uranium(VI) were determined in an aqueous medium at 25°C and ionic strength 0.500 M. The mode of coordination of this ligand is discussed.
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective To examine the anesthetic effects of a xylazine-diazepam-ketamine (XDK) combination in roosters.Study design Prospective experimental trial.Animals Six healthy white Leghorn roosters weighing 2.03 +/- 0.08 kg.Methods Each rooster was pre-medicated with xylazine (3 mg kg(-1), IM) and after 15 minutes anesthesia was induced with a diazepam (4 mg kg(-1)) and ketamine (25 mg kg(-1)) combination injected into the pectoral muscles. Heart and respiratory rates were recorded before anesthesia and every 15 minutes after induction for 165 minutes. Cloacal temperature was measured before and 15 minutes after pre-medication and every 75 minutes thereafter during anesthesia. Quality of induction and recovery were scored subjectively; duration of loss of righting reflex, abolition of response to a painful stimulus and palpebral reflex were also recorded.Results Intramuscular injection of xylazine smoothly induced loss of the righting reflex within 3-4 minutes. Loss of response to a painful stimulus occurred at 13.1 +/- 2.9 minutes (mean +/- SD) after the administration of the D-K combination, and lasted for 63.0 +/- 5.3 minutes. Roosters anesthetized with this combination had a significant decrease in heart and respiratory rates and cloacal temperature. The recovery period lasted for up to 4 hours (227.5 +/- 15.4 minutes). Quality of recovery was satisfactory for four roosters but excitation was noted in two birds.Conclusions and clinical relevance The XDK combination was a useful anesthetic technique for typhlectomy in roosters. Nevertheless this drug combination should be used with caution and cardiopulmonary parameters monitored carefully. Under the conditions of this experiment it was associated with a decreased cloacal temperature and prolonged recoveries.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective-To compare the ability of a sidestream capnograph and a mainstream capnograph to measure end-tidal CO2 (ETCO2) and provide accurate estimates of Paco(2) in mechanically ventilated dogs.Design-Randomized, double Latin square.Animals-6 healthy adult dogs.Procedure-Anesthesia was induced and neuromuscular blockade achieved by IV administration of pancuronium bromide. Mechanical ventilation was used to induce conditions of standard ventilation, hyperventilation, and hypoventilation. While tidal volume was held constant, changes in minute volume ventilation and Paco(2) were made by changing the respiratory rate. Arterial blood gas analysis was performed and ETCO2 measurements were obtained by use of either a mainstream or a sidestream capnographic analyzer.Results-A linear regression model and bias analysis were used to compare Paco(2) and ETCO2 measurements; ETCO2 measurements obtained by both capnographs correlated well with Paco(2). Compared with Paco(2), mainstream ETCO2 values differed by 3.15 +/- 4.89 mm Hg (mean bias +/- SD), whereas the bias observed with the sidestream ETCO2 system was significantly higher (5.65 +/- 5.57 mm Hg). Regardless of the device used to measure ETCO2, bias increased as Paco(2) exceeded 60 mm Hg.Conclusions and Clinical Relevance-Although the mainstream capnograph was slightly more accurate, both methods of ETCO2 measurement correlated well with Paco(2) and reflected changes in the ventilatory status. However, ETCO2 values > 45 mm Hg may inaccurately reflect the severity of hypoventilation as Paco(2) may be underestimated during conditions of hypercapnia (Paco(2) > 60 mm Hg).
Resumo:
Objective To compare the cardiorespiratory changes induced by equipotent concentrations of halothane (HAL), isoflurane (ISO) and sevollurane (SEVO) before and after hemorrhage.Study design. Prospective, randomized clinical trial.Animals. Twenty-four healthy adult dogs weighing 15.4 +/- 3.4 kg (mean +/- SD).Methods. Animals were randomly allocated to one of three groups (n = 8 per group). In each group, anesthesia was maintained with 1.5 minimum alveolar concentration of HAL (1.3%), ISO (1.9%,) and SEVO (3.5%) in oxygen. Controlled ventilation was performed to maintain eucapnia. Cardiorespiratory variables were evaluated at baseline (between 60 and 90 minutes after induction), immediately after and 30 minutes after the withdrawal of 32 mL kg(-1) of blood (400% of the estimated blood volume) over a 30-minute period.Results. During baseline conditions, ISO and SEVO resulted in higher cardiac index (CI) than HAL. Heart rates were higher with SEVO at baseline. while mean arterial pressure (MAP) and mean pulmonary arterial pressure did not differ between groups. Although heart rate values were higher for ISO and SEVO after hemorrhage, only ISO resulted in a higher CI when compared with HAL. In ISO-anesthetized dogs, MAP was higher immediately after hemorrhage, and this was related to better maintenance of CI and to an increase in systemic vascular resistance index from baseline.Conclusions. Although the hemodynamic responses of ISO and SEVO are similar in normovolaemic dogs, ISO results in better maintenance of circulatory function during the early period following a massive blood loss. Clinical relevance Inhaled anesthetics should be used judiciously in animals presented with blood loss. However, if an inhalational agent is to be used under these circumstances, ISO may provide better hemodynamic stability than SEVO or HAL.