4 resultados para functioning profile

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Scent-marking behavior is associated with different behavioral contexts in callitrichids, including signalizing a territory, location of feeding resources, and social rank. In marmosets and tamarins it is also associated with intersexual communication. Though it appears very important for the daily routine of the individuals, very few researchers have investigated distribution through the 24-h cycle. In a preliminary report, we described a preferential incidence of this behavior 2 h before nocturnal rest in families of common marmosets. We expand the data using 8 family groups (28 subjects), 8 fathers, 6 mothers, 8 nonreproductive adults (4 sons and 4 daughters), and 6 juvenile (3 sons and 3 daughters) offspring that we kept in outdoor cages under natural environmental conditions. We recorded the frequency of anogenital scent marking for each group during the light phase, twice a wk, for 4 consecutive wks, from March 1998 to September 1999. Cosinor test detected 24- and 8-h variations in 89.3% and 85.7% of the subjects, respectively, regardless of sex or reproductive status. The 8-h component is a consequence of the 2 peaks for the behavior, at the beginning and end of the light phase. Daily distribution of scent marking is similar to that others described previously for motor activity in marmosets. The coincident rhythmical patterns for both behaviors seem to be associated with feeding behavior, as described for callitrichids in free-ranging conditions, involving an increase in foraging activities early in the morning and shortly before nocturnal rest

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study had as objective to identify to the perception of mothers and professionals of health on the attention to the health of HIV-Positive children/adolescents in the city of Natal-RN. It is a descriptive-exploratory study with quantitative and qualitative approach, carried through in the Giselda Trigueiro Hospital and in the State and Municipal Health Councils in Natal - RN, from march to december of 2005. The sample was composed by 56 participants, 33 mothers of children who use specialized assistance and 23 professionals. Data collection occurred with the application of a half-structuralized interview. Quantitative data were analyzed through descriptive statistics and qualitative data were submitted to content analysis. Prevailing categories in relation to the cartography of the attention to seropositive children and adolescents in Natal were: Organization and dynamics of the attention; Institutional management and human development; Control and prevention; other contexts of attention; relationship/communication team-patient and organization and functioning of the services. The profile epidemiologist of the children, adolescents and of the people/mothers, who take care of them with HIV/Aids, followed the evolution of the epidemic in the country and the world. It was verified that mothers need care and information; however they make a positive evaluation of the attendance they receive. It was also observed many gaps in the services of assistance, in which the researched group was attended, beyond imperfections in the communication between health professionals and users. The professionals recognize the advances that the politics represent for the assistance of people with Aids; however feel themselves limited by the precariousness of the system and the partner-economic conditions of the people. According to these data, it can be verified great challenges to go through in the context of integrality of the assistance to HIV positive children and adolescents in the city of Natal and in the improvement of the communication in the institution of reference

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The usual programs for load flow calculation were in general developped aiming the simulation of electric energy transmission, subtransmission and distribution systems. However, the mathematical methods and algorithms used by the formulations were based, in majority, just on the characteristics of the transmittion systems, which were the main concern focus of engineers and researchers. Though, the physical characteristics of these systems are quite different from the distribution ones. In the transmission systems, the voltage levels are high and the lines are generally very long. These aspects contribute the capacitive and inductive effects that appear in the system to have a considerable influence in the values of the interest quantities, reason why they should be taken into consideration. Still in the transmission systems, the loads have a macro nature, as for example, cities, neiborhoods, or big industries. These loads are, generally, practically balanced, what reduces the necessity of utilization of three-phase methodology for the load flow calculation. Distribution systems, on the other hand, present different characteristics: the voltage levels are small in comparison to the transmission ones. This almost annul the capacitive effects of the lines. The loads are, in this case, transformers, in whose secondaries are connected small consumers, in a sort of times, mono-phase ones, so that the probability of finding an unbalanced circuit is high. This way, the utilization of three-phase methodologies assumes an important dimension. Besides, equipments like voltage regulators, that use simultaneously the concepts of phase and line voltage in their functioning, need a three-phase methodology, in order to allow the simulation of their real behavior. For the exposed reasons, initially was developped, in the scope of this work, a method for three-phase load flow calculation in order to simulate the steady-state behaviour of distribution systems. Aiming to achieve this goal, the Power Summation Algorithm was used, as a base for developing the three phase method. This algorithm was already widely tested and approved by researchers and engineers in the simulation of radial electric energy distribution systems, mainly for single-phase representation. By our formulation, lines are modeled in three-phase circuits, considering the magnetic coupling between the phases; but the earth effect is considered through the Carson reduction. It s important to point out that, in spite of the loads being normally connected to the transformer s secondaries, was considered the hypothesis of existence of star or delta loads connected to the primary circuit. To perform the simulation of voltage regulators, a new model was utilized, allowing the simulation of various types of configurations, according to their real functioning. Finally, was considered the possibility of representation of switches with current measuring in various points of the feeder. The loads are adjusted during the iteractive process, in order to match the current in each switch, converging to the measured value specified by the input data. In a second stage of the work, sensibility parameters were derived taking as base the described load flow, with the objective of suporting further optimization processes. This parameters are found by calculating of the partial derivatives of a variable in respect to another, in general, voltages, losses and reactive powers. After describing the calculation of the sensibility parameters, the Gradient Method was presented, using these parameters to optimize an objective function, that will be defined for each type of study. The first one refers to the reduction of technical losses in a medium voltage feeder, through the installation of capacitor banks; the second one refers to the problem of correction of voltage profile, through the instalation of capacitor banks or voltage regulators. In case of the losses reduction will be considered, as objective function, the sum of the losses in all the parts of the system. To the correction of the voltage profile, the objective function will be the sum of the square voltage deviations in each node, in respect to the rated voltage. In the end of the work, results of application of the described methods in some feeders are presented, aiming to give insight about their performance and acuity

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The usual programs for load flow calculation were in general developped aiming the simulation of electric energy transmission, subtransmission and distribution systems. However, the mathematical methods and algorithms used by the formulations were based, in majority, just on the characteristics of the transmittion systems, which were the main concern focus of engineers and researchers. Though, the physical characteristics of these systems are quite different from the distribution ones. In the transmission systems, the voltage levels are high and the lines are generally very long. These aspects contribute the capacitive and inductive effects that appear in the system to have a considerable influence in the values of the interest quantities, reason why they should be taken into consideration. Still in the transmission systems, the loads have a macro nature, as for example, cities, neiborhoods, or big industries. These loads are, generally, practically balanced, what reduces the necessity of utilization of three-phase methodology for the load flow calculation. Distribution systems, on the other hand, present different characteristics: the voltage levels are small in comparison to the transmission ones. This almost annul the capacitive effects of the lines. The loads are, in this case, transformers, in whose secondaries are connected small consumers, in a sort of times, mono-phase ones, so that the probability of finding an unbalanced circuit is high. This way, the utilization of three-phase methodologies assumes an important dimension. Besides, equipments like voltage regulators, that use simultaneously the concepts of phase and line voltage in their functioning, need a three-phase methodology, in order to allow the simulation of their real behavior. For the exposed reasons, initially was developped, in the scope of this work, a method for three-phase load flow calculation in order to simulate the steady-state behaviour of distribution systems. Aiming to achieve this goal, the Power Summation Algorithm was used, as a base for developping the three phase method. This algorithm was already widely tested and approved by researchers and engineers in the simulation of radial electric energy distribution systems, mainly for single-phase representation. By our formulation, lines are modeled in three-phase circuits, considering the magnetic coupling between the phases; but the earth effect is considered through the Carson reduction. Its important to point out that, in spite of the loads being normally connected to the transformers secondaries, was considered the hypothesis of existence of star or delta loads connected to the primary circuit. To perform the simulation of voltage regulators, a new model was utilized, allowing the simulation of various types of configurations, according to their real functioning. Finally, was considered the possibility of representation of switches with current measuring in various points of the feeder. The loads are adjusted during the iteractive process, in order to match the current in each switch, converging to the measured value specified by the input data. In a second stage of the work, sensibility parameters were derived taking as base the described load flow, with the objective of suporting further optimization processes. This parameters are found by calculating of the partial derivatives of a variable in respect to another, in general, voltages, losses and reactive powers. After describing the calculation of the sensibility parameters, the Gradient Method was presented, using these parameters to optimize an objective function, that will be defined for each type of study. The first one refers to the reduction of technical losses in a medium voltage feeder, through the installation of capacitor banks; the second one refers to the problem of correction of voltage profile, through the instalation of capacitor banks or voltage regulators. In case of the losses reduction will be considered, as objective function, the sum of the losses in all the parts of the system. To the correction of the voltage profile, the objective function will be the sum of the square voltage deviations in each node, in respect to the rated voltage. In the end of the work, results of application of the described methods in some feeders are presented, aiming to give insight about their performance and acuity