74 resultados para esgotos domésticos
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
In Natal still dominates the use of individual disposal systems for domestic sewage, once only 29% of the city has a sewarage system. Wastes that are accumulated in these individual treatment systems should be exhausted periodically, service provided by collector entrepreneurs. Some of these companies causing major damage to the environment. In Natal, only two companies have their own septage (RESTI) treatment system, which were designed with parameters from domestic sewage generating strain and inefficient systems. Therefore, the characterization becomes essential as a source of parameters for their design. Thus, this work presents the physical-chemical and microbiological characterization of waste pumped from individual sewage treatment systems. Samples collections were made weekly from 5 different trucks at the reception point on the treatment plant on the point of the preliminary treatment. From each truck it was taken 5 samples during the discharge in order to make a composite sample. Afterwards, samples were carried out to laboratory and analyses for determination of temperature, pH, conductivity, BOD, COD, nitrogen (ammonia e organic), alkalinity, oils, phosphorus, solids, faecal coliforms and helminth egg. The results were treated as a single database, and ranked according to its generating source (multi and single house, lodging, health, services and / or food), area of origin (metropolitan, south and north) and type of system (cesspits, septic tank and / or sink). Through these data it was possible to verify that the type of system adopted by most in Natal and the metropolitan region is cesspit, besides to confirm the difference between the septage of areas with a population have different social and economical characteristics. It was found that the septage have higher concentrations than domestic sewage, except for thermotolerant coliforms that showed concentrations of 1,38E+07. Among the parameters studied, is the median values identified for COD (3,549 mg / L), BOD (973mg / L) and total solids (3.557mg / L). The volatile fraction constitutes about 70% of the total solids of the septage. For helminths has been a median of 7 eggs/L. In general, the characteristics of the waste followed the variability found in the literature reviewed for all variables, showing high amplitudes
Resumo:
The Pirangi beach is located in the eastern coastline of Rio Grande do Norte state, in the municipality of Parnamirim and Nísia Floresta. In it flow into Pirangi Watershed (PW), whose water receives large amounts of pollutants, mainly domestic and industrial sewage from districts where pass the rivers that consist it, compromising, thus, the bathing water quality of the Pirangi beach. Bearing in mind the importance of water sanitary quality to ensure an environment that no present risk to the bathers s health, this work had as main objective to assess the influence of the PW s waters in the bathing water quality of the Pirangi beaches. To that end, were made collections of water in the beaches and in the rivers with the intention of quantify the fecal contamination indicators thermotolerant coliforms and enterococci, to then classify the conditions of bathing water quality according with the CONAMA Resolution number 274 of 2000. For the purposes greater knowledge about the health conditions of the Beaches Pirangi and about the influence the PW s waters exert on it, was done parallely to the study of the water quality, an investigation of the sand sanitary quality. Furthermore, it was made an evaluation of the PW s Water Quality through Water Quality Index (WQI). Starting from the results obtained in the research present was possible to verify, among other aspects, that the entry of the PW s waters in the Pirangi beaches exerts direct influence in the bathing water quality of the same ones, being the North Pirangi beach (point tracking PA-02) the most influenced. There was noticed also a significant reduction in the conditions of bathing water quality of the beaches in the rainy season. However, the precariousness do sewerage system of the Natal metropolitan region and the absence of a right system of treatment an final disposal of domestic sewage and industrial are the main factors responsi le for deterioration of the PW s Water Quality, and as a consequence, compromising the bathing water quality of the Pirangi beaches
Resumo:
The detention and infiltration ponds of urban drainage system has function to protect the population from undesirable effects of floods. In general these ponds are not completly used and it potential is wasted. As it are disseminated at different places at cities it can reduce costs with water transport and permit water preservation of best quality. Some it utilities includes use in green areas irrigation, industrial among than cooling towers and boiler, soil compaction, cleaning urban road, pisciculture and fire fighting system. The quality these water is influenced by anauthorized sewage in the drainage system. This study was performed in six detention and infiltration ponds at drainage system of Natal, which aim was to verify the non-portable use these ponds on urban environment. As indirect aim would to incentive the water utilization these ponds as a water source to another uses in urban environment. These ponds represents the characteristics of detention and infiltration of Natal city and consequently of Brazil. As the water quality, the ponds presents following characteristics: three has apparently good quality, other showed intermediate condition and two had water polluted. Were performed twenty sample in each ponds and the following parameters assessed: pH, temperature, dissolved oxygen, turbidity, electrical conductivity, coliform thermotolerant, ammonia, organic nitrogen, TKN, nitrate, total phosphorus and alkalinity, bicarbonate, chloride, total hardness, calcium and magnesium hardness, total solids, TSS, TDS, COD and SAR°. To utilization on pisciculture we recommend use in ponds which presents the best quality. Only one pond presented higher pollutants and it not being appropriated for use in cooling tower. The content of solids suspension restricted the water use in all ponds in boilers. As water use in soil compaction, cleaning urban road and fire fighting system the water from these ponds are not appropriated. However, the recommended limits from literature are to domestic sewage, due to this, the parameters are restrictive to diminish the sanitary risk that could be offered with it utilization. The infiltration velocity of water these assessed ponds restrict a moderato use, however the effects are potentiated only in soil less sandy, which not occur in Natal. It is recommend the unrestricted irrigation utilization in ponds with best quality of water, and a restricted irrigation to ponds with worst quality of water. As load of pollutants, it is recommended a complementary treatment in those ponds whit higher load to diminish sanitary risks. In only one pond was found one helminth eggs and due to the convention formula of results, it was found for all ponds less than 1 helminth/liter eggs.
Resumo:
Stabilization pond system consisting in more sewage treatment used in Rio Grande do Norte (RN), Brazil, representing about 90% of all systems. Fecal bacteria are removed mainly facultative ponds and in maturation ponds. Many factors influence bacterial decay, such as the levels of pH and DO, temperature, light intensity, HDT and nutrient availability. The bacterial decay rate (Kb) is calculated considering many variables, but the hydraulic regime is a significant influence for microorganisms removal, and the dispersed flow which best characterizes a stabilization pond. However, some authors developed equations for the Kb accordant plug flow and complete mixing. This research study aimed to evaluate the bacterial decay of fecal coliform and Enterococcus sp. in stabilization ponds designed to treat domestic sewage, full-scale, in RN. All systems have assessed pretreatment, a facultative pond (LF) followed by two maturation (LM1 and LM2). The parameters availed were: temperature, pH, DO, BOD5, COD, fecal coliform, Enterococcus sp., Chlorophyll a, total suspended solids, fixed and volatile. In general, there were not significant differences for pH, DO and temperature in the ponds, except for the new systems, since they have low flow and hydraulic loads. The removal of organic matter in the ponds was low, about 70%, and nearly all are overloaded organic and operational problems. The bacterial removals were low, with average 96% for LF for fecal coliform, and 98% for Enterococcus sp.; LM1 were in itself a removal for fecal coliform about 71%, and 81% for Enterococcus sp.; LM2 have efficiency of 69% for fecal coliform, and 68% for Enterococcus sp. The equation proposed by Von Sperling (1999), according to the dispersed flow regime, generated empirical values of Kb more approximate to calculated values of Kb. On average, the calculated Kb to coliforms in the LF was 0.31 d-1, and for both maturation ponds were 0.35 d-1. For Enterococcus sp. the average was 0.40 d-1 for LF, 0.55 d-1 for LM1, and 0.58 d-1 for LM2. These results also showed that the Kb obtained in full-scale systems are smaller than those found in pilot-scale ponds. Moreover, one can say that the equation proposed by Marais (1974), according to the complete-mix regime, overestimates Kb. Actual results of Kb indicated that fecal coliforms are more resistant to adverse conditions present in stabilization ponds than Enterococcus sp., therefore, an indicator of microbiological safety and efficiency. The factors significant interventions in the rate of bacterial decay were concentrations of COD, the organic loading and HDT. The few Kb relationship between pH, DO and temperature were not significant. Finally, we conclude that it s essential to correct operation and maintenance, for not performing these activities is one of the main factors contributing to low rates of bacterial decay.
Resumo:
Stabilization pond is the main technology used for treatment wastewater, in northeast Brazil, due to lower cost of deployment, operation and maintenance compared to other technologies. Most systems of stabilization ponds has been in operation for some time, on average 10 years of operation, receiving high organic loads and do not have good removal efficiencies of the main parameters for which have been designed. Therefore it is necessary to work to quantify the efficiency of current systems. This study evaluated the biodegradability of organic matter in raw sewage, the removal of organic matter in reactors and determination of the kinetic constant removal of organic matter (k), both in reactors and in raw sewage, based on the analysis made in the laboratory and through mathematical methods proposed in the literature, in nine systems stabilization ponds, located in Rio Grande do Norte. In relation the degradation kinetics in stabilization ponds, it was observed that many papers published in the literature were obtained in pilot-scale systems, which often, due to the action of external factors such as wind and temperature, these can t be considered as a reference in the analysis of the kinetic constant K, so the need for more research into systems of scale. This study had three distinct phases and simultaneous, routine monitoring, study of the daily cycle and the determination of kinetic constant of degradation of organic matter (K). The monitoring showed that the removal efficiencies of organic matter on most systems were lower than suggested by the literature, the best efficiencies of around 76% (BOD) and 72% (COD) and the worst of the order of 48% (BOD) and 55% (COD). The calculation of K in raw sewage (Ke) was within the range of variation expected in the literature (0.35 to 0.60 days-1). Already for the results obtained for K in the reactors (Kr), there were well below the values recommended in the literature (0.25 to 0.40 d-1 for complete mix and from 0.13 to 0.17 d-1 for flow dispersed), in line with the overloads that organic systems are subject
Resumo:
In Natal/RN, 68% of the population uses some kind of individual system for their domestic sewers treatment, being that the most used it is septic tank, followed by sumidouro. Every treatment system of sewers, usually used, generates a by-product denominated sludge. That residue presents some components, in its constitution, undesirable under the environmental and sanitary point of view. In such case, to assure that the system treatment has satisfactory results, it is necessary to do the adjusted disposition of the sludge sewage. Several countries are looking for technical alternatives for the use and disposition of residues. Under technical and environmental conditions appropriate, these materials can be used, decreasing the consumption of the natural resources and the treatment need, storage or elimination of the wastes, what decrease the risks created. Some of the alternatives of recycling of the sludge sewage are: the application in the agriculture, in the production of energy and as raw material in the civil construction. This study evaluated asphalt mixtures behavior that partially substituted conventional aggregates by septic tank sludge. The septic tank sludge gave origin to two raw materials called raw sludge and sludge ash. The raw sludge was put as a small aggregate and the sludge ash as filler. In the first experiment it was made a comparison between the mixture with conventional aggregates and the mixtures that replaced sand by raw sludge in the proportions from 5% to 40%. In the second experiment, it was made comparison between mixtures with 1%, 2% and 3% of sludge ash and cement. The stages developed along the study were: physical characterization of the conventional materials; physical, chemistry, thermal, mineralogical characterizations and analysis of environmental risk of the raw sludge; physical characterization and analysis of environmental risk of the sludge ash; analysis of the mixtures performance through its volumetric and mechanical characteristics; forecast of the mixtures susceptibility in the moisture presence. For the grain size composition used and with the percentage asphalt adopted, the mixtures with up to 7,5% of raw sludge in his composition attend to the National Department of Transports Infrastructure (DNIT) specifications. However, in agreement with the mixtures susceptibility in the moisture presence, the mixtures with addition of raw sludge don't present satisfactory acting. In such case, they could be used in arid and semi-arid areas. The raw sludge application in mixtures increased their voids volume and their stability. However, it damaged mixtures adhesiveness. Mixtures with sludge ash and with cement presented similar behavior. However, mixtures with sludge ash presented a better performance than mixtures with cement as for their stability and their tensile strength ratio. The mixture with 1% of sludge ash is better. The wastes studied don't represent environmental risk
Resumo:
This study is an environmental diagnosis of the Jundiaí-Potengi/RN estuarine system waters, using calculations of pollution indicator indices such as the Water Quality Index (WQI) and the Toxicity Index (TI). The samples were collected at twelve points on the estuary, at high and low tide, between August and November 2007, over four campaigns. The study area, located in a high impact region, has various activities on its banks such as: discharge of untreated or undertreated domestic and industrial sewage, shrimp farming, immunizer stabilization lakes, riverside communities, etc. All the parameters analyzed were compared to the limits of CONAMA Resolution No. 357 of 2005 for healthy and saline Class 1 waters. The results found prove the impact caused by various activities, mainly the parameters related to the presence of organic material, such as DQO, DBO, COT and thermotolerant colliforms. The IQA for most of the collection points was of medium quality. For the metals, although values above the Resolution limits were found, most of them were lower than the detection limits of ICP-OES used, indicating that they tend to be transported by the dynamic of the tides or rainfall and are deposited in bottom sediments, resulting in a TI of 1.0 in this water, when they are absent, which occurs in most cases, or 0.0, when heavy metals are found in these waters
Resumo:
Heavy metals can cause problems of human poisoning by ingestion of contaminated food, and the environment, a negative impact on the aquatic fauna and flora. And for the presence of these metals have been used for aquatic animals biomonitoramento environment. This research was done in order to assess the environmental impact of industrial and domestic sewage dumped in estuaries potiguares, from measures of heavy metals in mullet. The methods used for these determinations are those in the literature for analysis of food and water. Collections were 20 samples of mullet in several municipality of the state of Rio Grande do Norte, from the estuaries potiguares. Were analyzed the content of humidity, ash and heavy metals. The data were subjected to two methods of exploratory analysis: analysis of the main components (PCA), which provided a multivariate interpretation, showing that the samples are grouped according to similarities in the levels of metals and analysis of hierarchical groupings (HCA), producing similar results. These tests have proved useful for the treatment of the data producing information that would hardly viewed directly in the matrix of data. The analysis of the results shows the high levels of metallic species in samples Mugil brasiliensis collected in Estuaries /Potengi, Piranhas/Açu, Guaraíra / Papeba / Arês and Curimataú
Resumo:
Several studies have been developed regarding health risks associated with the recreational use of beaches contaminated with domestic sewage. These wastes contain various microorganisms, including Candida tropicalis, etiologic agent of both superficial infections such as systemic, as well as indicator of fecal contamination for the environment. In this context, the objective of this study was to characterize C. tropicalis isolates from the sandy beach of Ponta Negra, Natal, Rio Grande do Norte, Brazil, regarding the expression of in vitro virulence factors, adaptation to osmotic stress and susceptibility to antifungal drugs. We analyzed 62 environmental isolates of C. tropicalis and observed a great variation between them for the various virulence factors evaluated. In general, environmental isolates were more adherent to CEBH than C. tropicalis ATCC13803 reference strain, besides the fact they were also highly biofilm producers. In relation to morphogenesis, most isolates presented wrinkled phenotype in Spider medium (34 isolates, 54.8 %). When assessing enzyme activity, most isolates had higher proteinase production than C. tropicalis ATCC13803 reference strain. In addition, 35 isolates (56.4 %) had high hemolytic activity (hemolysis index > 55). With regard to C. tropicalis resistance to osmotic stress, 85.4% of the isolates were able to grow in a liquid medium containing 15% sodium chloride, corroborating to high survival capacity described for this yeast at marine environment. Finally, with regard to sensitivity to antifungal drugs, it was observed high resistance to the azoles tested, with the occurrence of the "Low-high" phenomenon and similar effect to the paradoxical growth which occurs to the echinocandins. For the three azoles tested we verified that 15 strains were resistant (24.2 %). Some strains were also resistant to amphotericin B (14 isolates, 22.6 %), while all of them were sensitive for the echinocandins tested. Therefore, our results demonstrate that C. tropicalis isolated from the sand of northeast of Brazil can fully express virulence attributes and showed a high persistence capacity on the coastal environment, in addition of being significantly resistant to most applied antifungals in current clinical practice. This constitutes a potential health risk to visitors of this environment, especially immunocompromised individuals and those with extreme age range.
Resumo:
This paper evaluate the performance of a Wastewater Treatment Plant (WWTP) in sequential batch activated sludge modality with tertiary treatment step, located in high temperature region. It also presents the analysis of organic matter’s removal and the evaluation of sludge sedimentation conditions through reactors in bench scale, fed with different substrate’s and biomass’ concentrations, from the WWTP in study. The results showed high efficiency and stability of the treatment process using Sequential Batch Reactors for domestic sewage, even with sudden changes of organic and hydraulic load, reaching more than 90% of efficiency in the removal of biodegradable organic matter. The removal of organic matter and sedimentation tests in bench reactors showed the good performance in respect of the organic matter’s removal, however, the high concentration of micro-organism results in a lower sludge sedimentation rate, which can compromise the quality of the final effluent. The relation Food/Microorganism in the conditions of the WWTP’s current operation showed a value of 0.06 gCOD/gVSS.d. and zonal sedimentation velocity of 0.59 m/h, the great ratio of the concentration of the substrate by biomass concentration, which obtained the maximum operational efficiency, showed a value of 0.09 gCOD/gVSS.d. and zonal sedimentation velocity of 1.4 m/h.
Resumo:
This paper evaluate the performance of a Wastewater Treatment Plant (WWTP) in sequential batch activated sludge modality with tertiary treatment step, located in high temperature region. It also presents the analysis of organic matter’s removal and the evaluation of sludge sedimentation conditions through reactors in bench scale, fed with different substrate’s and biomass’ concentrations, from the WWTP in study. The results showed high efficiency and stability of the treatment process using Sequential Batch Reactors for domestic sewage, even with sudden changes of organic and hydraulic load, reaching more than 90% of efficiency in the removal of biodegradable organic matter. The removal of organic matter and sedimentation tests in bench reactors showed the good performance in respect of the organic matter’s removal, however, the high concentration of micro-organism results in a lower sludge sedimentation rate, which can compromise the quality of the final effluent. The relation Food/Microorganism in the conditions of the WWTP’s current operation showed a value of 0.06 gCOD/gVSS.d. and zonal sedimentation velocity of 0.59 m/h, the great ratio of the concentration of the substrate by biomass concentration, which obtained the maximum operational efficiency, showed a value of 0.09 gCOD/gVSS.d. and zonal sedimentation velocity of 1.4 m/h.
Resumo:
The Pitimbu River is located at the oriental portion of the State of Rio Grande do Norte, including three importants cities named Macaíba, Parnamirim e Natal. Although its high importance as a water source, which supplys great part of the South Zone of the Natal city, this river receives a large quantity of domestic and industrial waste water without treatment. The Pitimbu River headhas its river-head located in the city of Macaiba, goes through Parnamirim, then it flowing into at the Jiqui Lake in Natal. The aim of this study was to evaluate, qualitatively and quantitatively, the environmental quality of the Pitimbu River by genotoxicity bio-assays, which are important tools for genetics toxicological evaluation. In this work, five samples sites, distributed along the river, were used to collect water samples. Another point site, located near Jiqui lake, was used to collect drinkable water, which was treated by CAERN, the water treatment entreprise of Rio Grande do Norte. The following assays where used to evaluate the quality of these samples: Allium cepa assay; Comet assay; Micronuclei (MN) assay; and Ames test. For the Allium cepa assay, sixteen specimes where used for each water sample from the sample sites. In this assay both microscopic, like cytogenetic damage, and macroscopic aspects, as morphological variation were evaluated. Red blood cells from periferical blood of the Crenicichla menezesi native specie were used not only for the MN assay, but also for the Comet assay. These fishes were collected at different points on the Pitimbu River and the negative control was developed using fishes of the same species that were bring to the laboratory and maintained for 100 days in the optimal experimental conditions. For the Ames test, TA100, YG1042, TA98 and YG1041 strains were used in the directed method without metabolic activation. The results found by the Allium cepa assay showed that two water sample sites induced increase of mitotic index (IM). Additionally, compared to the control, all the water samples increased the chromossomal aberrations frequency and/or micronucleus. Among the sample sites, two also showed an abnormal growth rate in its root and two samples induced morphological alteration. With the MN test in red blood cells, a high frequence of MN was observed in tree sample. By comparing all the results obtained on the water sample points and with the negative control, a significant variation on the MN frequency was observed. Positive results were also observed for the same sample to water test by the Comet assay. These results allow concluding that the proposed specie Crenicichla menezesi has a good profile as a bio-indicator for the evaluation of environmental water quality and the MN and comet test can be usuful for in situ evaluation. By the Ames test, it was possible to detect the mutagenic activity on the waters from the Pitimbu River in different levels of mutagenicity. This result suggests that this river has several substances that induced changes directly to the DNA. The mechanisms involved to this phenomenon could be by both processes, by changing of the reading frame and by nucleotide substitution. These data set indicate the presence of mutagenic agents, which can represent in risk to biot and human beens
Resumo:
Sludge of Wastewater Treatment Plants (WTPs) disposal is a problem for any municipality, for this reason the amount of sludge production is now a key issue in selecting treatment methods. It is necessary to investigate new applications for this waste type, due to the restrictions imposed by the environmental organs. The raw materials used in the Red Ceramic, are generally very heterogeneous, for this reason, such materials can tolerate the presence of different types of wastes. In Rio Grande do Norte, the roof tiles production corresponds to 60,61% from the total of ceramic units produced. Due to the importance of the ceramic industry of roof tiles for the state, allied to the environmental problem of the sludge disposal, this work had for objective to verify the possibility of the incorporation of sewage sludge in ceramic body used for production of roof tiles. In the research, sludge originating from drying beds of WTP of the Central Campus from UFRN and clays originating from a ceramic industry from Goianinha/RN were used. The raw materials were characterized by techniques of: analysis of particles distribution by diffraction to laser; real density; consistence limits; chemical analysis by X-ray fluorescence; mineralogical analysis by X-ray diffraction; organic matter; and solids content. Five batches of roof tiles were manufactured in the approximate dosages of 2%, 4%, 6%, 8% and 10%. To evaluate the properties of each final product, tests of water absorption, impermeability, bending strength, leachability and solubility were accomplished. The roof tiles manufactured with sludge presented characteristics similar to the roof tiles without sludge in relation to the environmental risk. The results showed that it is possible to use approximately up to 4% of sludge in ceramic bodies for production of roof tiles. However, it is observed that the high amount of organic matter (71%) present in the sludge is shown as factor that limits the sludge incorporation in ceramic bodies, worsening the quality of the roof tiles. It is necessary the use of mixtures of different raw materials under point of view of the granulometry and of the other chemical and mineralogical properties for the obtaining of a satisfactory mass to the production of ceramic roof tiles
Resumo:
The use of membrane filters in the post-treatment of sewage has been increasingly employed to obtain water quality, applicable to various forms of reuse. Despite the advantages presented using the permeate membranes, such as saving water and reducing water pollution, the concentrate generated in the process ends up being an inconvenience to the deployment of this technology due to lack of sustainable solutions for their management. Thus, the main objective of this research was to evaluate the use of membranes for microfiltration, ultrafiltration, nanofiltration and reverse osmosis concentrated in agriculture, using it as liquid fertilizer. The permeated membranes were also assessed in order to identify activities in which they could be reused. Five configurations were established from four types of membranes, so that each configuration represents a different system. The tests were conducted in batch mode, with triplicate for each configuration. The results indicated that permeated the microfiltration and ultrafiltration can be used in urban areas, in non-potable uses. Have the nanofiltration permeate can be reused in the industry, replacement cooling towers, and other non -potable uses required in the manufacturing unit. The permeate obtained in reverse osmosis met the intended uses for nanofiltration as well as the standards required for boiler feed, adding alkalizing being required to raise the pH to the recommended value. Concentrates generated in nanofiltration and reverse osmosis can be availed as liquid fertilizer in agriculture, but they must be diluted in the irrigation water, in order to adjust the salt concentration allowed for the least tolerant crops patterns
Resumo:
The deficit of water and sewerage services is a historic problem in Brazil. The introduction of a new regulatory framework, in 2007, presented ways intending to overcome these deficits, among them, the providers efficiency improvement. This thesis aims to analyze the regulators performance regarding its ability to induce the efficiency of the Brazilian water and sewerage services providers. To this end, an analytical approach based on a sequential explanatory strategy was used, and it consists of three steps. In the first step, the Data Envelopment Analysis ( DEA ) was used to measure the providers efficiency in 2006 and 2011. The results show that the average efficiency may be considered high; however significant inefficiencies among the 29 analyzed providers were detected. The ones in the Southeast region showed better performance level and Northeast had the lowest. The local and the private providers were more efficient on average. In 2006 and 2011 the average performance was higher among non-regulated providers. In 2006 the group regulated by local agencies had the best average performance, in 2011, the best performance was the group regulated by the consortium agencies. To analyse the second step was used the Malmquist Index, it pointed that the productivity between 2006 and 2011 dropped. The analysis through decomposing Malmquist Index showed a shift of technical efficiency frontier to a lower level, however was detected a small provider s advance towards the frontier. Only the Midwest region recorded progress in overall productivity. The deterioration in the total factor productivity was higher among regional providers but the local ones and the private agencies moved quickly to the frontier level. The providers regulated from 2007 showed less decrease on the total productivity and the results of the catch up effect were more meaningful. In the last step, the regulators standardization activity analyses noted that there are agencies that had not issued rules until 2011. The most standards topics discussed in the issued rules were the tariff adjustments and the setting of general conditions for the provision and use of services; in another hand, the least covered topics were new technologies incentive and the introduction of efficiency-inducing regulatory mechanisms and productivity gains for price reviews. Regulators created from 2007 were more active proportionately. Even with the advent of the regulatory framework and the creation of new regulatory bodies, the evidence points to a reality in which the actions of these agencies have not been ensuring that providers of water and sewage, regulated by them, has achieved better performance. The non- achievement of regulatory goals can be explained by the incipient level of performance of the Brazilian regulatory authorities, which should be strengthened because of its potential contribution to the Brazilian basic sanitation department