3 resultados para concurrent validity

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introdução: The scales of cognitive screening are important tools for early detection of dementia, creating the possibility of developing measures to slow this process and assist in the management of the disease. Objective: To validate the Leganés Cognitive Test (Prueba Cognitive de Leganés) (PCL) for cognitive screening in low educated elderly Brazilians. Methods: The study sample was composed of 59 elderly residents from the city of Santa Cruz, Brazil with low schooling levels. Reliability was analyzed with a 2-day interval between assessments, and concurrent validity was assessed using the Mini Mental State Examination (MMSE). Results: According to the PCL, the prevalence of dementia was 11.8%. The scale items showed a moderate to strong correlation between domains (p <0.01), and inter-rater reliability exhibited ICC = 0.81, 95% CI (0.72-0.88). Factor analysis resulted in two factors: memory and orientation. Interscale agreement was considered poor (k = - 0.02), supporting the hypothesis of an educational impact on final MMSE scores. Conclusion: The results suggest that PCL has acceptable levels of reliability for use in low educated elderly Brazilians

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives: to translate and assess the psychometric properties of the Brazilian short-form of the Mobility Assessment Tool (MAT-sf) in Brazilians community elderly. Methds: the 12 items MAT-sf went through the process of translation and back translation into Portuguese of the Brazil, considering the semantic and cultural adaptation. In a sample of 150 aged 65-74 years living in the community, the instrument's psychometric properties were evaluated by analysis of convergent and construct validity and test-retest reliability. The main outcomes measures used for validation included in the battery of tests of physical ability, self-repor measures of functional limitations, health, depression, cognitive and sex. The test-retest reliability of the instrument was assessed using the intra-class correlation coefficient (ICC), 40 subjects were reassessed after an interval of 14 days of assessment. Results: the concurrent validity for the MAT-sf was evidenced by significant correlations with SPPB (r = 0,53), number of functional limitations (r = -0,62) and depressive symptoms (r = -0,45). The construct validity of the instrument was measured by gradual and significant increase of the MAT-sf scores with high levels of physical performance and with positive self-reported health, also found that MAT-sf scores were statistically differents according to sex. The variation in MAT-sf scores (R2 = 0,41) was explained by SPPB, number of limitations for activities of daily life and depressive symptoms. High values for test-retest reliability was evidencend by ICC = 0,94, 95% CI = 0,90 0,97. Conclusions: the Brazilian version of the short-form of the Mobility Assessment Tool has values of validity and reliability to ensure its use in elderly populations living in communities

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Physical activity is one of the main components of a healthy lifestyle, responsible for many health benefits. Despite being considered important for both disease prevention and health promotion there is high prevalence of sedentary behavior in the elderly population. Questionnaires are practical and feasible instruments for assessing levels of physical activity. However, they may have limitations in older age ranges. Accelerometers, movement sensors that make physical activity data more objective, emerge as reliable measuring devices. Aim: Determine the validity of the International Physical Activity Questionnaire (IPAQ) adapted for elderly with accelerometry in elderly women. Methods: 57 elderly women, with mean age of 66.05 ± 5.98 years who took part in hypertension control and physical activity incentive programs were assessed in relation to objective and subjective measures of physical activity. The accelerometer was used for 07 consecutive days, 24 hours per day before the IPAQ was applied. Data were analyzed using measures of central tendency and dispersion to characterize the sample according to variables collected. To check the validity of the data we used the Spearman correlation test, considering a significance level of p <0.05. Results: With respect to the categories of physical activity obtained by IPAQ, 46.4% developed moderate physical activity, followed by a high (30.3%) and low level (23.2%). There was a negative correlation only between self-reported time spent sitting and time spent on light activities as measured by accelerometry (r = - 0.408; p = 0.003) and mean activity level (counts/min) with physical activity levels evaluated by IPAQ (r = 0.297; p = 0.036). Conclusion: The IPAQ used in elderly women shows moderate to low validity levels according to accelerometry measures. Assessment of sedentary activities exhibited acceptable levels compared to accelerometry; however, moderate (r = 0.096; p > 0.05) to vigorous (r = 0.098; p > 0.05) activities were not correlated, demonstrating the inability of IPAQ to evaluate this type of activity in elderly women