2 resultados para best estimate method
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
Gene therapy is based on the transfer of exogenous genetic material into cells or tissues in order to correct, supplement or silencing a particular gene. To achieve this goal, efficient vehicles, viral or non-viral, should be developed. The aim of this work was to produce and evaluate a nanoemulsion system as a possible carrier for no-viral gene therapy able to load a plasmid model (pIRES2-EGFP). The nanoemulsion was produced by the sonication method, after been choose in a pseudo-ternary phase diagram build with 5 % of Captex 355®, 1.2 % of Tween 80®, 0.8 % of Span 80®, 0.16% of stearylamine and water (to 100 %). Measurements of droplet size, polydispersity index (PI), zeta potential, pH and conductivity, were performed to characterize the system. Results showed droplets smaller than 200 nm (PI < 0.2) and zeta potential > 30 mV. The formulation pH was near to 7.0 and conductivity was that expected to oil in water systems (70 to 90 μS/s) A scale up study, the stability of the system and the best sterilization method were also evaluated. We found that the system may be scaled up considering the time of sonication according to the volume produced, filtration was the best sterilization process and nanoemulsions were stable by 180 days at 4 ºC. Once developed, the complexation efficiency of the plasmid (pDNA) by the system was tested by agarose gel electrophoresis retardation assay.. The complexation efficiency increases when stearylamine was incorporated into aqueous phase (from 46 to 115 ng/μL); regarding a contact period (nanoemulsion / pDNA) of at least 2 hours in an ice bath, for complete lipoplex formation. The nanoemulsion showed low toxicity in MRC-5 cells at the usual transfection concentration, 81.49 % of survival was found. So, it can be concluded that a nanoemulsion in which a plasmid model was loaded was achieved. However, further studies concerning transfectation efficiency should be performed to confirm the system as non-viral gene carrier
Resumo:
This work intends to analyze the behavior of the gas flow of plunger lift wells producing to well testing separators in offshore production platforms to aim a technical procedure to estimate the gas flow during the slug production period. The motivation for this work appeared from the expectation of some wells equipped with plunger lift method by PETROBRAS in Ubarana sea field located at Rio Grande do Norte State coast where the produced fluids measurement is made in well testing separators at the platform. The oil artificial lift method called plunger lift is used when the available energy of the reservoir is not high enough to overcome all the necessary load losses to lift the oil from the bottom of the well to the surface continuously. This method consists, basically, in one free piston acting as a mechanical interface between the formation gas and the produced liquids, greatly increasing the well s lifting efficiency. A pneumatic control valve is mounted at the flow line to control the cycles. When this valve opens, the plunger starts to move from the bottom to the surface of the well lifting all the oil and gas that are above it until to reach the well test separator where the fluids are measured. The well test separator is used to measure all the volumes produced by the well during a certain period of time called production test. In most cases, the separators are designed to measure stabilized flow, in other words, reasonably constant flow by the use of level and pressure electronic controllers (PLC) and by assumption of a steady pressure inside the separator. With plunger lift wells the liquid and gas flow at the surface are cyclical and unstable what causes the appearance of slugs inside the separator, mainly in the gas phase, because introduce significant errors in the measurement system (e.g.: overrange error). The flow gas analysis proposed in this work is based on two mathematical models used together: i) a plunger lift well model proposed by Baruzzi [1] with later modifications made by Bolonhini [2] to built a plunger lift simulator; ii) a two-phase separator model (gas + liquid) based from a three-phase separator model (gas + oil + water) proposed by Nunes [3]. Based on the models above and with field data collected from the well test separator of PUB-02 platform (Ubarana sea field) it was possible to demonstrate that the output gas flow of the separator can be estimate, with a reasonable precision, from the control signal of the Pressure Control Valve (PCV). Several models of the System Identification Toolbox from MATLAB® were analyzed to evaluate which one better fit to the data collected from the field. For validation of the models, it was used the AIC criterion, as well as a variant of the cross validation criterion. The ARX model performance was the best one to fit to the data and, this way, we decided to evaluate a recursive algorithm (RARX) also with real time data. The results were quite promising that indicating the viability to estimate the output gas flow rate from a plunger lift well producing to a well test separator, with the built-in information of the control signal to the PCV