11 resultados para Xenomai, Xbee, control loop, PID, BeagleBone

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents a proposal for a voltage and frequency control system for a wind power induction generator. It has been developed na experimental structure composes basically by a three phase induction machine, a three phase capacitor and a reactive static Power compensator controlled by histeresys. lt has been developed control algorithms using conventional methods (Pl control) and linguistic methods (using concepts of logic and fuzzy control), to compare their performances in the variable speed generator system. The control loop was projected using the ADJDA PCL 818 model board into a Pentium 200 MHz compu ter. The induction generator mathematical model was studied throught Park transformation. It has been realized simulations in the Pspice@ software, to verify the system characteristics in transient and steady-state situations. The real time control program was developed in C language, possibilish verify the algorithm performance in the 2,2kW didatic experimental system

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Methods for compensation of harmonic currents and voltages have been widely used since these methods allow to reduce to acceptable levels the harmonic distortion in the voltages or currents in a power system, and also compensate reactive. The reduction of harmonics and reactive contributes to the reduction of losses in transmission lines and electrical machinery, increasing the power factor, reduce the occurrence of overvoltage and overcurrent. The active power filter is the most efficient method for compensation of harmonic currents and voltages. The active power filter is necessary to use current and voltage controllers loop. Conventionally, the current and voltage control loop of active filter has been done by proportional controllers integrative. This work, investigated the use of a robust adaptive control technique on the shunt active power filter current and voltage control loop to increase robustness and improve the performance of active filter to compensate for harmonics. The proposed control scheme is based on a combination of techniques for adaptive control pole placement and variable structure. The advantages of the proposed method over conventional ones are: lower total harmonic distortion, more flexibility, adaptability and robustness to the system. Moreover, the proposed control scheme improves the performance and improves the transient of active filter. The validation of the proposed technique was verified initially by a simulation program implemented in C++ language and then experimental results were obtained using a prototype three-phase active filter of 1 kVA

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of middleware technology in various types of systems, in order to abstract low-level details related to the distribution of application logic, is increasingly common. Among several systems that can be benefited from using these components, we highlight the distributed systems, where it is necessary to allow communications between software components located on different physical machines. An important issue related to the communication between distributed components is the provision of mechanisms for managing the quality of service. This work presents a metamodel for modeling middlewares based on components in order to provide to an application the abstraction of a communication between components involved in a data stream, regardless their location. Another feature of the metamodel is the possibility of self-adaptation related to the communication mechanism, either by updating the values of its configuration parameters, or by its replacement by another mechanism, in case of the restrictions of quality of service specified are not being guaranteed. In this respect, it is planned the monitoring of the communication state (application of techniques like feedback control loop), analyzing performance metrics related. The paradigm of Model Driven Development was used to generate the implementation of a middleware that will serve as proof of concept of the metamodel, and the configuration and reconfiguration policies related to the dynamic adaptation processes. In this sense was defined the metamodel associated to the process of a communication configuration. The MDD application also corresponds to the definition of the following transformations: the architectural model of the middleware in Java code, and the configuration model to XML

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Synchronous machines, widely used in energy generation systems, require constant voltage and frequency to obtain good quality of energy. However, for large load variati- ons, it is difficult to maintain outputs on nominal values due to parametric uncertainties, nonlinearities and coupling among variables. Then, we propose to apply the Dual Mode Adaptive Robust Controller (DMARC) in the field flux control loop, replacing the tradi- tional PI controller. The DMARC links a Model Reference Adaptive Controller (MRAC) and a Variable Structure Model Reference Adaptive Controller (VS-MRAC), incorpora- ting transient performance advantages from VS-MRAC and steady state properties from MRAC. Moreover, simulation results are included to corroborate the theoretical studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multi-Cloud Applications are composed of services offered by multiple cloud platforms where the user/developer has full knowledge of the use of such platforms. The use of multiple cloud platforms avoids the following problems: (i) vendor lock-in, which is dependency on the application of a certain cloud platform, which is prejudicial in the case of degradation or failure of platform services, or even price increasing on service usage; (ii) degradation or failure of the application due to fluctuations in quality of service (QoS) provided by some cloud platform, or even due to a failure of any service. In multi-cloud scenario is possible to change a service in failure or with QoS problems for an equivalent of another cloud platform. So that an application can adopt the perspective multi-cloud is necessary to create mechanisms that are able to select which cloud services/platforms should be used in accordance with the requirements determined by the programmer/user. In this context, the major challenges in terms of development of such applications include questions such as: (i) the choice of which underlying services and cloud computing platforms should be used based on the defined user requirements in terms of functionality and quality (ii) the need to continually monitor the dynamic information (such as response time, availability, price, availability), related to cloud services, in addition to the wide variety of services, and (iii) the need to adapt the application if QoS violations affect user defined requirements. This PhD thesis proposes an approach for dynamic adaptation of multi-cloud applications to be applied when a service is unavailable or when the requirements set by the user/developer point out that other available multi-cloud configuration meets more efficiently. Thus, this work proposes a strategy composed of two phases. The first phase consists of the application modeling, exploring the similarities representation capacity and variability proposals in the context of the paradigm of Software Product Lines (SPL). In this phase it is used an extended feature model to specify the cloud service configuration to be used by the application (similarities) and the different possible providers for each service (variability). Furthermore, the non-functional requirements associated with cloud services are specified by properties in this model by describing dynamic information about these services. The second phase consists of an autonomic process based on MAPE-K control loop, which is responsible for selecting, optimally, a multicloud configuration that meets the established requirements, and perform the adaptation. The adaptation strategy proposed is independent of the used programming technique for performing the adaptation. In this work we implement the adaptation strategy using various programming techniques such as aspect-oriented programming, context-oriented programming and components and services oriented programming. Based on the proposed steps, we tried to assess the following: (i) the process of modeling and the specification of non-functional requirements can ensure effective monitoring of user satisfaction; (ii) if the optimal selection process presents significant gains compared to sequential approach; and (iii) which techniques have the best trade-off when compared efforts to development/modularity and performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

MEDEIROS, Adelardo A. D.A survey of control architectures for autonomous mobile robots. J. Braz. Comp. Soc., Campinas, v. 4, n. 3, abr. 1998 .Disponível em: Acesso: 27 set. 2010.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

On this paper, it is made a comparative analysis among a controller fuzzy coupled to a PID neural adjusted by an AGwith several traditional control techniques, all of them applied in a system of tanks (I model of 2nd order non lineal). With the objective of making possible the techniques involved in the comparative analysis and to validate the control to be compared, simulations were accomplished of some control techniques (conventional PID adjusted by GA, Neural PID (PIDN) adjusted by GA, Fuzzy PI, two Fuzzy attached to a PID Neural adjusted by GA and Fuzzy MISO (3 inputs) attached to a PIDN adjusted by GA) to have some comparative effects with the considered controller. After doing, all the tests, some control structures were elected from all the tested techniques on the simulating stage (conventional PID adjusted by GA, Fuzzy PI, two Fuzzy attached to a PIDN adjusted by GA and Fuzzy MISO (3 inputs) attached to a PIDN adjusted by GA), to be implemented at the real system of tanks. These two kinds of operation, both the simulated and the real, were very important to achieve a solid basement in order to establish the comparisons and the possible validations show by the results

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The main objective of work is to show procedures to implement intelligent control strategies. This strategies are based on fuzzy scheduling of PID controllers, by using only standard function blocks of this technology. Then, the standardization of Foundation Fieldbus is kept. It was developed an environment to do the necessary tests, it validates the propose. This environment is hybrid, it has a real module (the fieldbus) and a simulated module (the process), although the control signals and measurement are real. Then, it is possible to develop controllers projects. In this work, a fuzzy supervisor was developed to schedule a network of PID controller for a non-linear plant. Analyzing its performance results to the control and regulation problem

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The area of research and development involving the PID tune of controllers is an active area in the academic and industrial sectors yet. All this due to the wide use of PID controllers in the industry (96% of all controllers in the industry is still PID). Controllers well tuned and tools to monitor their performance over time with the possibility of selftuning, become an item almost obligatory to maintain processes with high productivity and low cost. In a globalized world, it is essential for their self survival. Although there are several new tools and techniques that make PID tune, in this paper will explore the PID tune using the relay method, due its good acceptance in the industrial environment. In addition, we will discuss some techniques for evaluation of control loops, as IAE, ISE, Goodhart, the variation of the control signal and index Harris, which are necessary to propose new tuning for control loops that have a low performance. Will be proposed in this paper a tool for tuning and self tuning PID. Will be proposed in this paper a PID auto-tuning software using a relay method. In particular, will be highlighted the relay method with hysteresis. This method has shown tunings with satisfactory performance when applied to the didactic, simulated and real plants

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The treatment of wastewaters contaminated with oil is of great practical interest and it is fundamental in environmental issues. A relevant process, which has been studied on continuous treatment of contaminated water with oil, is the equipment denominated MDIF® (a mixer-settler based on phase inversion). An important variable during the operation of MDIF® is the water-solvent interface level in the separation section. The control of this level is essential both to avoid the dragging of the solvent during the water removal and improve the extraction efficiency of the oil by the solvent. The measurement of oil-water interface level (in line) is still a hard task. There are few sensors able to measure oil-water interface level in a reliable way. In the case of lab scale systems, there are no interface sensors with compatible dimensions. The objective of this work was to implement a level control system to the organic solvent/water interface level on the equipment MDIF®. The detection of the interface level is based on the acquisition and treatment of images obtained dynamically through a standard camera (webcam). The control strategy was developed to operate in feedback mode, where the level measure obtained by image detection is compared to the desired level and an action is taken on a control valve according to an implemented PID law. A control and data acquisition program was developed in Fortran to accomplish the following tasks: image acquisition; water-solvent interface identification; to perform decisions and send control signals; and to record data in files. Some experimental runs in open-loop were carried out using the MDIF® and random pulse disturbances were applied on the input variable (water outlet flow). The responses of interface level permitted the process identification by transfer models. From these models, the parameters for a PID controller were tuned by direct synthesis and tests in closed-loop were performed. Preliminary results for the feedback loop demonstrated that the sensor and the control strategy developed in this work were suitable for the control of organic solvent-water interface level

Relevância:

30.00% 30.00%

Publicador:

Resumo:

MEDEIROS, Adelardo A. D.A survey of control architectures for autonomous mobile robots. J. Braz. Comp. Soc., Campinas, v. 4, n. 3, abr. 1998 .Disponível em: Acesso: 27 set. 2010.