8 resultados para Teste cardiopulmonary exercise testing
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
Introduction: Chagas Disease is a serious public health problem, with 5 million infected individuals in Brazil. Of these, approximately 30% develop chronic Chagas cardiomyopathy (CCC), where the main symptoms are fatigue and dyspnea. Objective: To correlate maximal exercise capacity with pulmonary function, inspiratory muscle strength and quality of life in patients with CCC. Methodology: Twelve individuals suffering from CCC were evaluated (7 men), with a mean age of 54.91± 8.60 years and the following inclusion criteria: functional class II and III according to the New York Heart Association (NYHA); left ventricle ejection fraction below 45%; clinical stability (> 3 months); symptom duration > 1 year, body mass index (BMI) < 35Kg/m2 and non-smokers or ex-smokers with a history of smoking <10 packs/day. All subjects were submitted to spirometry, manometer testing, maximal cardiopulmonary exercise testing (CPX) and a quality of life questionnaire (Minnesota). Results: A negative correlation was observed between VO2máx and MLHFQ scores (r=-0.626; p=0.03) and a positive association with MIP (r=0.713; p=0.009). Positive correlations were also recorded between MIP and spirometric variables [FEV1(r=0.825;p=0.001 ), FVC(r=0.66;p=0.01 and FEF25-75%(r=0.639;p=0.02)]. Conclusion: The present study demonstrated that in patients with CCC: VO2MAX is directly related to inspiratory muscle strength and quality of life, while deteriorating lung function is directly associated with respiratory muscle weakness
Resumo:
obesity affects rightly functional capacity diminishing the cardiovascular system efficiency and oxygen uptake (VO2). Field tests, such as, Incremental Shuttle Walking Test (ISWT) and Six Minute Walk Test (6MWT) has been employed as alternative of Cardiopulmonary Exercise Test (CPX), to functional assessing for conditions which transport of oxygen to peripheral is diminished. Nevertheless, the knowing about metabolic variables response in real time and it comparing among different maximal and submaximal tests in obese is absent. Aim: to compare cardiopulmonary, metabolic response during CPX, ISWT and 6MWT and to analyse it influence of adiposity markers in obese. Material e Method: crosssectional, prospective study. Obese included if: (BMI>30Kg/m2; FVC>80%), were assessed as clinical, anthropometric (BMI, body adiposity index-BAI, waist-WC, hip- HC and neck-NC circumferences) and spirometry (forced vital capacity-FVC, Forced expiratory volume-1°second-FEV1, maximal voluntary ventilation-MVV) variables. Obese performed the sequence of tests: CPX, ISWT and 6MWT. Throughout tests was assessed breath-by-breath by telemetry system (Cortex-Biophysik-Metamax3B) variables; oxygen uptake on peak of activity (VO2peak); carbon dioxide production (VCO2); Volume Expiratory (VE); ventilatory equivalents for VO2 (VE/VO2) and CO2 (VE/VCO2); respiratory exchange rate (RER) and perceived effort-Borg6-20). Results: 15 obese (10women) 39.4+10.1years, normal spirometry (%CVF=93.7+9.7) finished all test. They have BMI (43.5+6.6kg/m2) and different as %adiposity (BAI=50.0+10.5% and 48.8+16.9% respectively women and men). Difference of VO2ml/kg/min and %VO2 were finding between CPX (18.6+4.0) and 6MWT (13.2+2.5) but not between ISWT (15.4+2.9). Agreement was found for ISWT and CPX on VO2Peak (3.2ml/kg/min; 95%; IC-3.0 9.4) and %VO2 (16.4%). VCO2(l/min) confirms similarity in production for CPX (2.3+1.0) and ISWT (1.7+0.7) and difference for 6MWT (1.4+0.6). WC explains more the response of CPX and ISWT than other adiposity markers. Adiposity diminishes 3.2% duration of CPX. Conclusion: ISWT promotes similar metabolic and cardiovascular response than CPX in obese. It suggesting that ISWT could be useful and reliable to assess oxygen uptake and functional capacity in obese
Resumo:
With the increasing complexity of software systems, there is also an increased concern about its faults. These faults can cause financial losses and even loss of life. Therefore, we propose in this paper the minimization of faults in software by using formally specified tests. The combination of testing and formal specifications is gaining strength in searches mainly through the MBT (Model-Based Testing). The development of software from formal specifications, when the whole process of refinement is done rigorously, ensures that what is specified in the application will be implemented. Thus, the implementation generated from these specifications would accurately depict what was specified. But not always the specification is refined to the level of implementation and code generation, and in these cases the tests generated from the specification tend to find fault. Additionally, the generation of so-called "invalid tests", ie tests that exercise the application scenarios that were not addressed in the specification, complements more significantly the formal development process. Therefore, this paper proposes a method for generating tests from B formal specifications. This method was structured in pseudo-code. The method is based on the systematization of the techniques of black box testing of boundary value analysis, equivalence partitioning, as well as the technique of orthogonal pairs. The method was applied to a B specification and B test machines that generate test cases independent of implementation language were generated. Aiming to validate the method, test cases were transformed manually in JUnit test cases and the application, created from the B specification and developed in Java, was tested. Faults were found with the execution of the JUnit test cases
Resumo:
This work intends to analyze the behavior of the gas flow of plunger lift wells producing to well testing separators in offshore production platforms to aim a technical procedure to estimate the gas flow during the slug production period. The motivation for this work appeared from the expectation of some wells equipped with plunger lift method by PETROBRAS in Ubarana sea field located at Rio Grande do Norte State coast where the produced fluids measurement is made in well testing separators at the platform. The oil artificial lift method called plunger lift is used when the available energy of the reservoir is not high enough to overcome all the necessary load losses to lift the oil from the bottom of the well to the surface continuously. This method consists, basically, in one free piston acting as a mechanical interface between the formation gas and the produced liquids, greatly increasing the well s lifting efficiency. A pneumatic control valve is mounted at the flow line to control the cycles. When this valve opens, the plunger starts to move from the bottom to the surface of the well lifting all the oil and gas that are above it until to reach the well test separator where the fluids are measured. The well test separator is used to measure all the volumes produced by the well during a certain period of time called production test. In most cases, the separators are designed to measure stabilized flow, in other words, reasonably constant flow by the use of level and pressure electronic controllers (PLC) and by assumption of a steady pressure inside the separator. With plunger lift wells the liquid and gas flow at the surface are cyclical and unstable what causes the appearance of slugs inside the separator, mainly in the gas phase, because introduce significant errors in the measurement system (e.g.: overrange error). The flow gas analysis proposed in this work is based on two mathematical models used together: i) a plunger lift well model proposed by Baruzzi [1] with later modifications made by Bolonhini [2] to built a plunger lift simulator; ii) a two-phase separator model (gas + liquid) based from a three-phase separator model (gas + oil + water) proposed by Nunes [3]. Based on the models above and with field data collected from the well test separator of PUB-02 platform (Ubarana sea field) it was possible to demonstrate that the output gas flow of the separator can be estimate, with a reasonable precision, from the control signal of the Pressure Control Valve (PCV). Several models of the System Identification Toolbox from MATLAB® were analyzed to evaluate which one better fit to the data collected from the field. For validation of the models, it was used the AIC criterion, as well as a variant of the cross validation criterion. The ARX model performance was the best one to fit to the data and, this way, we decided to evaluate a recursive algorithm (RARX) also with real time data. The results were quite promising that indicating the viability to estimate the output gas flow rate from a plunger lift well producing to a well test separator, with the built-in information of the control signal to the PCV
Resumo:
The technique of ion nitriding, despite being fully consolidated in the industry, has great limitations when applied to the treatment of small parts. This is because effects that occur due to non-uniformity of the electric field, generate localized heating in parts, damaging the uniformity of nitrided layer. In addition, because the samples are treated static parts thereof are untreated. To expand the use of plasma nitriding, this work presents the development, assembly and testing of a prototype plasma reactor with rotatory cathodic cage [patent pending], able to meet these needs, giving the material a uniform treatment and opening doors to industrial scale production. The samples tested with hexagonal nuts are 6.0 mm in diameter, made of stainless steel AISI 304 nitrided at a pressure of 1 mbar in an atmosphere of 20% H2 + 80% N2 for 1 h. After treatment, testing visual inspection, optical microscopy and microhardness were carried out to check the effectiveness of the process for uniformity and hardness of the parts. All samples exhibited uniform color, and matte brownish, unlike the untreated samples, silver color and gloss. The hardness of the surface (top and sides) was 65% and even higher than the original hardness. The nitrided layer showed great uniformity in microstructure and thickness. It is concluded, therefore, that the unit was effective constructed for the purposes for which it was designed
Resumo:
Backgroud: Obesity is a major public health problem and is related to the low physical capacity when obese are compared to no-obese people, however the cause of this limitation is not completely understood. The measurement associated of physiological response to the telemetric 6MWT adds information of metabolic and respiratory system for diagnose of the functional limitation. Objective: Analyze physiological, metabolic and ventilatory responses in women with different body fat during the 6MWT. Methods: 32 women (8 non-obese, 8 Overweight, 8 Obese and 8 morbidly obese) were evaluated for anthropometry, lung function and exercise capacity. Results: Morbidly obese walked the shortest distance (400.2±38.7m), had lower VO2/Kg (12.75±3.20l/Kg/min) and lower R (0.74± 0.11) in the 6MWT compared to other groups. Analyses of metabolic (VO2 and VCO2) and respiratory (VE, VT and BF) during the test did not identify differences between groups. The evaluation of cardiac function (O2 pulse) found higher values in the OM (12.3 ± 4.9ml/bat). Conclusion: The OM had worse performance in the 6MWT compared to other groups. The physical performance may be reduced in this population related to a protocol-dependent response because the speed of 6MWT is self-adjusted allows the individual himself select the intensity of the test, making it set at a speed where there is energy saving
Resumo:
The main goal of Regression Test (RT) is to reuse the test suite of the latest version of a software in its current version, in order to maximize the value of the tests already developed and ensure that old features continue working after the new changes. Even with reuse, it is common that not all tests need to be executed again. Because of that, it is encouraged to use Regression Tests Selection (RTS) techniques, which aims to select from all tests, only those that reveal faults, this reduces costs and makes this an interesting practice for the testing teams. Several recent research works evaluate the quality of the selections performed by RTS techniques, identifying which one presents the best results, measured by metrics such as inclusion and precision. The RTS techniques should seek in the System Under Test (SUT) for tests that reveal faults. However, because this is a problem without a viable solution, they alternatively seek for tests that reveal changes, where faults may occur. Nevertheless, these changes may modify the execution flow of the algorithm itself, leading some tests no longer exercise the same stretch. In this context, this dissertation investigates whether changes performed in a SUT would affect the quality of the selection of tests performed by an RTS, if so, which features the changes present which cause errors, leading the RTS to include or exclude tests wrongly. For this purpose, a tool was developed using the Java language to automate the measurement of inclusion and precision averages achieved by a regression test selection technique for a particular feature of change. In order to validate this tool, an empirical study was conducted to evaluate the RTS technique Pythia, based on textual differencing, on a large web information system, analyzing the feature of types of tasks performed to evolve the SUT
Resumo:
Background: Cardiac Rehabilitation (CR) has effect on mortality in patients with heart failure (HF) chronic, and the exercise of the treatment of this patient. The most common exercise is ongoing training. Recently we have been studying the effects of interval training, but there is no consensus on the optimal dose of exercise. Objective: To evaluate the effects of interval aerobic training are superior to continuous aerobic training in patients with chronic HF. Methods: The clinical trial evaluated patients through cardiopulmonary test (CPX) and quality of life before and after the RC (3 times / 12 weeks). Patients were randomized into Group Interval Training (GTI - 85% of heart rate reserve - FCR), Continuous Training Group (GTC - 60% of HRR) and control group (CG) who received guidelines. Results: 18 patients were evaluated (mean age 44.7 ± 13.2 years and 35.2 ± 8.9% of left ventricular ejection fraction [LVEF]). Both groups were efficient to increase the peak VO2 and 15.1% (P = 0.02) in GTI and 16.1% (P = 0.01) GTC. As for the quality of life the GTI GTC showed improvement compared to the control group (P = 0.006). Hemodynamic mismatch events during the CPX were reduced after training in more GTC (patients 1 to 4) than in the GTI (5 to 3). Cardiac risk also decreased in the GTC (3 patients left the severe risk to take after training). Conclusion: Continuous training becomes more appropriate for improving fitness with little chance of developing cardiac event patients with chronic HF.