4 resultados para Space Climatology
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
In recent years, the DFA introduced by Peng, was established as an important tool capable of detecting long-range autocorrelation in time series with non-stationary. This technique has been successfully applied to various areas such as: Econophysics, Biophysics, Medicine, Physics and Climatology. In this study, we used the DFA technique to obtain the Hurst exponent (H) of the profile of electric density profile (RHOB) of 53 wells resulting from the Field School of Namorados. In this work we want to know if we can or not use H to spatially characterize the spatial data field. Two cases arise: In the first a set of H reflects the local geology, with wells that are geographically closer showing similar H, and then one can use H in geostatistical procedures. In the second case each well has its proper H and the information of the well are uncorrelated, the profiles show only random fluctuations in H that do not show any spatial structure. Cluster analysis is a method widely used in carrying out statistical analysis. In this work we use the non-hierarchy method of k-means. In order to verify whether a set of data generated by the k-means method shows spatial patterns, we create the parameter Ω (index of neighborhood). High Ω shows more aggregated data, low Ω indicates dispersed or data without spatial correlation. With help of this index and the method of Monte Carlo. Using Ω index we verify that random cluster data shows a distribution of Ω that is lower than actual cluster Ω. Thus we conclude that the data of H obtained in 53 wells are grouped and can be used to characterize space patterns. The analysis of curves level confirmed the results of the k-means
Resumo:
The ethanol is the most overused psychoactive drug over the world; this fact makes it one of the main substances required in toxicological exams nowadays. The development of an analytical method, adaptation or implementation of a method known, involves a process of validation that estimates its efficiency in the laboratory routine and credibility of the method. The stability is defined as the ability of the sample of material to keep the initial value of a quantitative measure for a defined period within specific limits when stored under defined conditions. This study aimed to evaluate the method of Gas chromatography and study the stability of ethanol in blood samples, considering the variables time and temperature of storage, and the presence of preservative and, with that check if the conditions of conservation and storage used in this study maintain the quality of the sample and preserve the originally amount of analyte present. Blood samples were collected from 10 volunteers to evaluate the method and to study the stability of ethanol. For the evaluation of the method, part of the samples was added to known concentrations of ethanol. In the study of stability, the other side of the pool of blood was placed in two containers: one containing the preservative sodium fluoride 1% and the anticoagulant heparin and the other only heparin, was added ethanol at a concentration of 0.6 g/L, fractionated in two bottles, one being stored at 4ºC (refrigerator) and another at -20ºC (freezer), the tests were performed on the same day (time zero) and after 1, 3, 7, 14, 30 and 60 days of storage. The assessment found the difference in results during storage in relation to time zero. It used the technique of headspace associated with gas chromatography with the FID and capillary column with stationary phase of polyethylene. The best analysis of chromatographic conditions were: temperature of 50ºC (column), 150ºC (jet) and 250ºC (detector), with retention time for ethanol from 9.107 ± 0.026 and the tercbutanol (internal standard) of 8.170 ± 0.081 minutes, the ethanol being separated properly from acetaldehyde, acetone, methanol and 2-propanol, which are potential interfering in the determination of ethanol. The technique showed linearity in the concentration range of 0.01 and 3.2 g/L (0.8051 x + y = 0.6196; r2 = 0.999). The calibration curve showed the following equation of the line: y = x 0.7542 + 0.6545, with a linear correlation coefficient equal to 0.996. The average recovery was 100.2%, the coefficients of variation of accuracy and inter intra test showed values of up to 7.3%, the limit of detection and quantification was 0.01 g/L and showed coefficient of variation within the allowed. The analytical method evaluated in this study proved to be fast, efficient and practical, given the objective of this work satisfactorily. The study of stability has less than 20% difference in the response obtained under the conditions of storage and stipulated period, compared with the response obtained at time zero and at the significance level of 5%, no statistical difference in the concentration of ethanol was observed between analysis. The results reinforce the reliability of the method of gas chromatography and blood samples in search of ethanol, either in the toxicological, forensic, social or clinic
Resumo:
Alcohol is one of the few psychotropic drugs that their consumption has admitted legally and sometimes encouraged by the society. Studies show alcohol as the highest consumption of drugs among young people and society in general, probably because of its availability and easy access. The abuse causes public health problems, which was closely related to the violence, socioeconomic problems and the high number of automobile accidents. Transit is one of the main sectors affected by the effects of alcohol, observing a high incidence in the studies. About half of automobile accidents occurs after the consumption of alcoholic beverage, and the vast majority of cases related to high concentrations of alcohol in the bloodstream. The relationship of drunk with traffic accidents is in fact evident everywhere in the world, including Brazil, where studies have shown a high relationship between alcohol consumption and traffic accidents. This study determined the alcohol in fatal victims of traffic accidents in the state of Rio Grande do Norte and established the profile of this population compared with those found in Brazil and other countries. Samples of blood of ethanol added to fulfillment of the standardization of chromatographic conditions and procedures for the analysis, being employed in the determination of alcohol in blood samples of 277 victims of traffic accidents, collected at the Institute of Scientific Technical Police of Rio Grande do North (ITEP) in the year 2007. The blood alcohol level was determined in these samples correlated with the sex, age and marital status of the victim and the location, day of week and month when the accident occurred, is doing a statistical analysis and outlining a profile of the victims of an accident at transit in the state of Rio Grande do Norte. The parameters of standardization studied ensured the quality of the analytical method and, consequently, to obtain reliable laboratory results. Being given the best temperature for injector (150 ºC), detector (250 ºC) and column (50 ºC) with a flow of gas in the column of 2mL/minutos and analysis of time of 12 minutes. The method was linear in the range of 0.01 to 3.2 g / L (r2 = 0.9989) with average recovery of 100.2% and precision with coefficient of variation less than 15%. The analysis carried out on victims of fatal road traffic accidents, ethanol detected in the blood in 66.43% of the victims and these, 96% showed concentration ≥ 0.2 g / L, 87.73% of victims were male, while 12.27% female. The younger age group (1535 years) was the most involved (52,35%) and most single (55.60%). The accidents occurred with greater prevalence in the day on Monday (27%) followed by Sunday (24,19%) and Saturday (15,52%) and it was found that the prevalence of injuries varied between the different months of the year, and in February (14.4%) and April (10.47%) the months that had a higher number of accidents, however this oscillation showed no statistically significant difference. Also no significant difference was observed between the tracks of concentration found in men and women. The standardized method showed to be efficient, given satisfactorily to the goals of this work, and the high levels of alcohol found in victims of fatal road traffic accidents are consistent with several studies of literature, and the profile of the victim also supported by presenting in its most young adults, male and single
Resumo:
The oil industry, experiencing a great economic and environmental impact, has increasingly invested in researches aiming a more satisfactory treatment of its largest effluent, i.e., produced water. These are mostly discarded at sea, without reuse and after a basic treatment. Such effluent contains a range of organic compounds with high toxicity and are difficult to remove, such as polycyclic aromatic hydrocarbons, salts, heavy metals, etc.. The main objective of this work was to study the solar distillation of produced water pre-treated to remove salts and other contaminants trough of a hybrid system with a pre-heater. This developed apparatus was called solar system, which consists of a solar heater and a conventional distillation solar still. The first device consisted of a water tank, a solar flat plate collector and a thermal reservoir. The solar distillator is of simple effect, with 1m2 of flat area and 20° of inclination. This dissertation was divided in five steps: measurements in the solar system, i.e. temperatures and distillate flow rate and weather data; modeling and simulation of the system; study of vapor-liquid equilibrium of the synthetic wastewater by the aqueous solution of p-xylene; physical and chemical analyses of samples of the feed, distillate and residue, as well as climatology pertinent variables of Natal-RN. The solar system was tested separately, with the supply water, aqueous NaCl and synthetic oil produced water. Temperature measurements were taken every minute of the thermal reservoir, water tank and distillator (liquid and vapor phases). Data of solar radiation and rainfall were obtained from INPE (National Institute for Space Research). The solar pre-heater demonstrated to be effective for the liquid systems tested. The reservoir fluid had an average temperature of 58°C, which enabled the feed to be pre-heated in the distillator. The temperature profile in the solar distillator showed a similar behavior to daily solar radiation, with temperatures near 70°C. The distillation had an average yield of 2.4 L /day, i.e., an efficiency of 27.2%. Mathematical modeling aided the identification of the most important variables and parameters in the solar system. The study of the vapor-liquid equilibrium from Total Organic Carbon (TOC) analysis indicated heteroazeotropia and the vapor phase resulted more concentrated in p-xylene. The physical-chemical analysis of pH, conductivity, Total Dissolved Solids (TDS), chlorides, cations (including heavy metals) and anions, the effluent distillate showed satisfactory results, which presents a potential for reuse. The climatological study indicates the region of Natal-RN as favorable to the operation of solar systems, but the use of auxiliary heating during periods of higher rainfall and cloud cover is also recommended