4 resultados para Soil-pile Interaction
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
An experimental study has been conducted to investigate the behavior of continuous flight auger (cfa) bored piles and metalic driven H-section piles under lateral loading in cohesionless soils. The piles were tested in two different areas at the same site. Both areas consisted of a 3-m thick compacted superficial fill of pure fine sand, underlain by layers of naturally occurring pure fine-thick sand. Fills are differentiated by the relative densities which were compressed, 45% e 70%, respectively. Each area received one identical pair of cfa piles and two identical pairs of H-piles. A static lateral loading test was performed in each pair of piles. In this work, the pile load test results are reported and interpreted. The horizontal coefficient of subgrade reaction was determined from the results of the loading tests and compared with values determined by correlations based on penetration resistance index of SPT tests (NSPT). p-y formulations describing the static behavior of the piles were applied to the problem under evaluation. Back Analyses were made through theoretical and experimental p-y curves for obtaining input parameters for the analytic models, among which the coefficient of horizontal reaction. The soil pile system horizontal loading at rupture was determined by the theoretical methods and the results were compared with the experimental results, checking its validity
Resumo:
The study that resulted in this dissertation was developed at OU RNCE PETROBRAS, in Natal, which implemented a project of rational use and reuse of water, including use of wastewater from a Sewage Treatment Plant (STP) already in place, diluted with water from own wells for irrigation of green area of the building complex corporate enterprise. Establish a methodology that can serve as guidelines for future projects controlled reuse of water like this was the objective of this research. Been proposed, implemented and evaluated three instruments of sanitary and environmental control: 1) adaptation of sewage treatment plant and quality control of the treated effluent 2) analysis of soil-nutrient interaction in the irrigated area, 3) knowledge of the local hydrogeology, especially with regard to the direction of flow of the aquifer and location of collection wells of Companhia de Águas e Esgotos do Rio Grande do Norte (CAERN) situated in the surroundings. These instruments have proven sufficient and appropriate to ensure the levels of sanitary and environmental control proposed and studied, which were: a) control of water quality off the STP and the output of the irrigation reservoir, b) control of water quality sub surface soil and assessment of progress on soil composition, c) assessment of water quality in the aquifer. For this, we must: 1) establishing the monitoring plan of the STP and its effluent quality sampling points and defining the parameters of analysis, improve the functioning of that identifying the adequacy of flow and screening as the main factors of operational control, and increase the efficiency of the station to a relatively low cost, using additional filters, 2) propose, implement and adapt simple collectors to assess the quality of water percolating into the soil of the irrigated area, 3) determine the direction of groundwater flow in the area study and select the wells for monitoring of the aquifer.
Resumo:
The piles are one of the most important types of solution adopted for the foundation of buildings. They are responsible for transmitting to the soil in deepe r and resistant layers loads from structures. The interaction of the foundation element with the soil is a very important variable, making indispensable your domain in order to determine the strength of the assembly and establish design criteria for each c ase of application of the pile. In this research analyzes were performed f rom experiments load tests for precast concrete piles and inve stigations of soil of type SPT, a study was performed for obtaining the ultimate load capacity of the foundation through methods extrapolation of load - settlement curve , semi - empirical and theoretic . After that, were realized comparisons between the different methods used for two types of soil a granular behavior and other cohesive. For obtaining soil paramet ers to be used i n the methods were established empirical correlations with the standard penetration number (NSPT). The charge - settlement curves of the piles are also analyzed. In the face of established comparisons was indicated the most reliable semiempirical method Déco urt - Quaresma as the most reliable for estimating the tensile strength for granular and cohesive soils. Meanwhile, among the methods studied extrapolation is recommended method of Van der Veen as the most appropriate for predicting the tensile strength.
Resumo:
Retaining walls design involves factors such as plastification, loading and unloading, pre-stressing, excessive displacements and earth and water thrust. Furthermore, the interaction between the retained soil and the structure is rather complex and hard to predict. Despite the advances in numerical simulation techniques and monitoring of forces and displacements with field instrumentation, design projects are still based on classical methods, whose simplifying assumptions may overestimate structural elements of the retaining wall. This dissertation involves a three-dimensional numerical study on the behavior of a retaining wall using the finite element method (FEM). The retaining wall structure is a contiguous bored pile wall with tie-back anchors. The numerical results were compared to data obtained from field instrumentation. The influence of the position of one or two layers of anchors and the effects of the construction of a slab bounded at the top of the retaining wall was evaluated. Furthermore, this study aimed at investigating the phenomenon of arching in the soil behind the wall. Arching was evaluated by analyzing the effects of pile spacing on horizontal stresses and displacements. Parametric analysis with one layers of anchors showed that the smallest horizontal displacements of the structure were achieved for between 0.3 and 0.5 times the excavation depth. Parametric analyses with two anchor layers showed that the smallest horizontal displacements were achieve for anchors positioned in depths of 0.4H and 0.7H. The construction of a slab at the top of the retaining wall decreased the horizontal displacements by 0.14% times the excavation depth as compared to analyses without the slab. With regard to the arching , analyzes showed an optimal range of spacing between the faces of the piles between 0.4 and 0.6 times the diameter of the pile