7 resultados para Sand-quartzous soils

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

XIMENES, Maria de Fátima Freire de Melo; SOUZA, Maria de Fátima de; CASTELLON, Eloy Guilhermo. Density of sand flies (Diptera: Psychodidae) in domestic and wild animal shelters in an area of visceral Leishmaniasis in the State of Rio Grande do Norte, Brazil. Memorias do Instituto Oswaldo Cruz, Rio de Janeiro, v.94, n.4, p.427-432, jul./ago. 1999. Disponivel em: Acesso em: 4 out. 2010.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Today a major responsibility for the contamination of soil and groundwater and surface water are establishments known as gas stations of fuel which has attracted increasing attention from both the general population as the state agencies of environmental control due to leaks in storage tanks and mainly to disruption of pipe corrosion of tanks and pumping. Other services, like oil changes and car wash are also causes for concern in this type of establishment. These leaks can cause or waste produced, and the contamination of aquifers, serious health problems and public safety, since most of these stations located in urban areas. Based on this, the work was to evaluate soil contamination of a particular service station and fuel sales in the city of Natal, through the quantification of heavy metals like Cd, Cu, Cr, Ni, Pb, Zn of total organic carbon (TOC) and organic matter using different techniques such as optical emission spectrometry with inductively coupled plasma source (ICP OES), Total Organic Carbon analyzer and gravimetric analysis respectively. And also to characterize the soil through particle size analysis. Samples were taken in 21 georeferenced points and collected in the same period. The soils sampled in sampling stations P3, P5, P6, P10, P11, P12, P13, P14, P15, P17, P18 and P20 showed the smallest size fractions ranging from fine sand to medium sand. The other study sites ranged from fine sand to medium sand, except the point P8 showed that only the type size medium sand and P19, indicating a particle size of the coarse type. The small correlation of organic matter with the elements studied in this work suggests that these are not of anthropogenic origin but geochemical support

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents results of field and laboratory tests using a Dynamic Cone Penetrometer, DCP. The tests were performed in order to evaluate the use of the equipment in sand for the control of bearing capacity of shallow foundations and fill compaction. For shallow foundations, the laboratory tests were conducted on sand placed in a metallic mould by the method of sand pluviation. Although the results show the inability to reproduce field conditions in the laboratory it was possible to verify the ability of the DCP to identify less resistant soil layers. The DCP tests for the analysis of compaction control were performed in a strong box with inside dimensions of 1,40 m x 1,40 m and 0,70 m in height. The soil layers were compacted with different densities though the use of a vibrating plate in order to obtain correlations between penetration index, DPI, and soil relative density. Other tests were also conducted to assess the influence of soil moisture on tests results. Among other findings, the results showed the great potential for the use of DCP to control the compaction of sand fills

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Soil improved with the addition of cement have been utilized as an alternative to the construction of various types of geotechnical works, almost always present economic and environmental advantages. This paper presents a study on the usage of cement in the improvement of mechanical properties of sandy soils, characteristic of the region of Natal, collected from its dunes. This research was made in order to analyze the influence of cement content, voids, and also including water immersion and confining pressure. Samples molded from cement-soil mixtures were tested for unconfined compression tests and triaxial tests. The samples had the percentage of cement mixed in 2.5%, 5% and 10% by weight. The cement agent used was the Portland Cement of High Early strength(CPV-ARI), which promoted agility to the experimental procedure for presenting a rapid gain in strenght. The void ratio used ranged from 0.7 (more compact), 0,9 and 1,1(softer). The soil under study can be considered as pure sand. In general, it can be stated that the larger the amount of cement added to the sand studied is, the greater ultimate strength will be. Likewise, as more compact the soil is, the less void ratio and more resistant it will be present. The confining pressure tends to increase the resistance of the specimens. The cementing adopted grades showed that the use of different criteria for failure did not significantly alter the stress-strain parameters for the sand studied. The angle of friction values were found within the typical range of medium and compact sands. Cementing acted in the sand providing an intercepted cohesion which increased enhancing the potential cementation. In triaxial compression tests, the sand with void ratio is equal to 0.7 and showed the expected behavior for a compact sand while the stress-strain behavior of the same sand with the void ratio of 0.9 tended to be expected for the soft sand as well

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experimental study has been conducted to investigate the behavior of continuous flight auger (cfa) bored piles and metalic driven H-section piles under lateral loading in cohesionless soils. The piles were tested in two different areas at the same site. Both areas consisted of a 3-m thick compacted superficial fill of pure fine sand, underlain by layers of naturally occurring pure fine-thick sand. Fills are differentiated by the relative densities which were compressed, 45% e 70%, respectively. Each area received one identical pair of cfa piles and two identical pairs of H-piles. A static lateral loading test was performed in each pair of piles. In this work, the pile load test results are reported and interpreted. The horizontal coefficient of subgrade reaction was determined from the results of the loading tests and compared with values determined by correlations based on penetration resistance index of SPT tests (NSPT). p-y formulations describing the static behavior of the piles were applied to the problem under evaluation. Back Analyses were made through theoretical and experimental p-y curves for obtaining input parameters for the analytic models, among which the coefficient of horizontal reaction. The soil pile system horizontal loading at rupture was determined by the theoretical methods and the results were compared with the experimental results, checking its validity

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work embraces the application of Landsat 5-TM digital images, comprising August 2 1989 and September 22 1998, for temporal mapping and geoenvironmental analysis of the dynamic of Piranhas-Açu river mouth, situated in the Macau (RN) region. After treatment using several digital processing techniques (e.g. colour composition in RGB, ratio of bands, principal component analysis, index methods, among others), it was possible to generate several image products and multitemporal maps of the coastal morphodynamics of the studied area. Using the image products it was possible the identification and characterization of the principal elements of interest (vegetation, soil, geology and water) in the surface of the studied area, associating the spectral characteristics of these elements to that presented by the image products resulting of the digital processing. Thus, it was possible to define different types of soils: Amd, AQd6, SK1 and LVe4; vegetation grouping: open arboreal-shrubby caatinga, closed arborealshrubby caatinga, closed arboreal caatinga, mangrove vegetation, dune vegetation and areas predominately constituted by juremas; geological units: quaternary units beach sediments, sand banks, dune flats, barrier island, mobile dunes, fixed dunes, alluvium, tidal and inundation flats, and sandy facies of the Potengi Formation; tertiary-quaternary units Barreiras Formation grouped to the clayey facies of the Potengi Formation, Macau Formation grouped to the sediments of the Tibau Formation; Cretaceous units Jandaíra Formation; moreover it was to identify the sea/land limit, shallow submersed areas and suspended sediments. The multitemporal maps of the coastal morphodynamics allowed the identification and a semi-quantitative evoluation of regions which were submitted to erosive and constructive processes in the last decade. This semi-quantitative evoluation in association with an geoenvironmental characterization of the studied area are important data to the elaboration of actions that may minimize the possible/probable impacts caused by the implantation of the Polo Gas/Sal and to the monitoring of areas explorated by the petroleum and salt industries

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Because the penetration depth of Ground Penetrating Radar (GPR) signals is very limited in high conductive soils, the usefullness of this method in tropical regions is not yet completly known. The main objective of this researh is to test the usefullness of the method in Brazil. Two typical problems where GPR has been used in Europe and North American were choosed for this test: the first one is to characterize the internal structures of a sand body and the second problem is the localization of old buried pipes lines. The first test was done near the city of São Bento do Norte, in the northern coast of Rio Grande do Norte state, NE Brazil. In this region, there is a sand dune that is migrating very fast in the direction of adjacent settling areas. To characterize the internal structure of the dune and its relationship to the prevailing wind direction, as a preliminary step to understand the dune migration, GPR profiles using the 400 MHz frequency were performed in E-W, N-S, NE-SW, and SE-NW directions over the sand dune intersecting at the top of the dune. The practical resolution of the GPR data is around 30 cm; this was sufficient to distinguish individual foresets inside the dune. After applying the elevation correction to the data, we identified that dips of bedding structures are smallest for the N-S profile, which is perpendicular to the dominant wind direction, largest for the E-W profile, and intermediate for the SW-NE and SE-NW profiles. Foresets in the E-W profile dip with angles varying from 2 to 6 degrees. In the E-W profile, the water table and a horizontal truncation interface separating two generations of dunes were identified, as well as an abrupt directional change in the foreset patterns associated to a lateral contact between two dune generations, the older one extending to the west. The used high frequency of 400 Mhz does not allow a penetration deep enough to map completely these internal contacts. The second test was done near Estreito, a small town near Carnaúbais city, also in Rio Grande do Norte state. In this locality, there are several old pipe lines buried in area covered by plantations where digging should be minimized. Several GPR profiles using the 400 and 200 MHz frequency were performed trying to intercept perpendicularly the possible pipe lines. Because of the high conductivity of the soil, the raw original data can hardly be use to identify the pipe lines. However, after an adequate processing over the 200 MHz profiles, six pipe lines were identified. As a global result of the tests, GPR can be very usefull if the conductivity of the ground is low or, in the case of medium conductivities of the soils, if adequate processing is performed