10 resultados para Reparative and reactive fibrosis
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
Chronic weight loss in marmosets is often associated with wasting marmoset syndrome (WMS), an important disease that occurs in callitrichid colonies around the world. Even though its etiology is very difficult to determine, particular variables, such as weight loss, diarrhea and alopecia, associated or not with infestation in the pancreatic ducts with Trichospirura leptossoma (Nematoda: Thelazioidea), seem to be linked with the syndrome. This study investigated the histopathology of the lungs, duodenum, liver, gallbladder, extrahepatic bile ducts and pancreatic ducts of six common marmosets (Callithrix jacchus) suffering from severe non-diarrheic weight loss. Three individuals died naturally and the other three were euthanized. Microscopic findings showed the presence of adult flukes (Platynosomum) in the liver. These flukes, which provoke common infection in cats, were also observed inside the gallbladder as well as in the intra and extrahepatic bile ducts in common marmosets. Portal fibrosis was observed in two animals, which developed chronic fibrosing hepatopathy (biliary pattern, grade 3). The disease progresses without diarrhea and without pancreatic lesions or infestation. With the rogression, the animals presented with ascending cholangitis, cholestasis and portal fibrosis, sometimes culminating in secondary biliary cirrhosis. Therefore, this nfirmity, associated with chronic weight loss in common marmosets, could be another tiological factor linked with WMS
Resumo:
American visceral leishmaniasis (AVL), caused by Leishmania infantum chagasi (L.i.chagasi), stands as a public health problem in Brazil, with human and canine cases related in all states..Lipid metabolism can be modified in several status of infection. For example, experimental studies show that the cholesterol is necessary to internalization and replication of L.i.chagasi in macrophages through caveolar domains. Patients with AVL present low levels of cholesterol and a visible triglycerides increase. This work aimed to evaluate the lipid metabolism in several post-infection status by L.i.chagasi, including individuals with symptomatic infection (AVL), and asymptomatic. The levels of cholesterol, triglycerides, HDL and reactive C protein, were measured. Individuals with AVL were compared with individuals with assymptomatic infection and presented low levels of total cholesterol (128 ± 6.180 mg/dL vs. 158 ±5.733 mg/dL, p=0.0001), HDL (29 ± 1.746 mg/dL vs. 37 ± 1.647 mg/dL, p=0.0001), increased levels of triglycerides (149.5 mg/dL ± 12.72 vs. 78.00 ± 10.43 mg/dL, p=0.0095) and higher levels of reactive C protein (1.750± 0.4939 mg/dL vs. 0.40 ± 0.1707 mg/dL; p=0.0001). The expression of genes related to lipid metabolism, such as LXR-a, LXR-b, PPAR-a, PPAR-d, PPAR-g and APOE was evaluated by real time PCR. A reduction in the expression of those genes was found in the group of AVL patients corroborating the serum levels of the metabolites earlier quantified. Our findings suggest a modulation of metabolism of lipids, in the chronic phase of AVL, this could facilitate the survival of leishmania, due to the known reduction on the ability of macrophages in presenting antigens efficiently to the T cells due to the reduction in the cholesterol available, it results in a subversion of the host immunity.
Resumo:
The usual programs for load flow calculation were in general developped aiming the simulation of electric energy transmission, subtransmission and distribution systems. However, the mathematical methods and algorithms used by the formulations were based, in majority, just on the characteristics of the transmittion systems, which were the main concern focus of engineers and researchers. Though, the physical characteristics of these systems are quite different from the distribution ones. In the transmission systems, the voltage levels are high and the lines are generally very long. These aspects contribute the capacitive and inductive effects that appear in the system to have a considerable influence in the values of the interest quantities, reason why they should be taken into consideration. Still in the transmission systems, the loads have a macro nature, as for example, cities, neiborhoods, or big industries. These loads are, generally, practically balanced, what reduces the necessity of utilization of three-phase methodology for the load flow calculation. Distribution systems, on the other hand, present different characteristics: the voltage levels are small in comparison to the transmission ones. This almost annul the capacitive effects of the lines. The loads are, in this case, transformers, in whose secondaries are connected small consumers, in a sort of times, mono-phase ones, so that the probability of finding an unbalanced circuit is high. This way, the utilization of three-phase methodologies assumes an important dimension. Besides, equipments like voltage regulators, that use simultaneously the concepts of phase and line voltage in their functioning, need a three-phase methodology, in order to allow the simulation of their real behavior. For the exposed reasons, initially was developped, in the scope of this work, a method for three-phase load flow calculation in order to simulate the steady-state behaviour of distribution systems. Aiming to achieve this goal, the Power Summation Algorithm was used, as a base for developing the three phase method. This algorithm was already widely tested and approved by researchers and engineers in the simulation of radial electric energy distribution systems, mainly for single-phase representation. By our formulation, lines are modeled in three-phase circuits, considering the magnetic coupling between the phases; but the earth effect is considered through the Carson reduction. It s important to point out that, in spite of the loads being normally connected to the transformer s secondaries, was considered the hypothesis of existence of star or delta loads connected to the primary circuit. To perform the simulation of voltage regulators, a new model was utilized, allowing the simulation of various types of configurations, according to their real functioning. Finally, was considered the possibility of representation of switches with current measuring in various points of the feeder. The loads are adjusted during the iteractive process, in order to match the current in each switch, converging to the measured value specified by the input data. In a second stage of the work, sensibility parameters were derived taking as base the described load flow, with the objective of suporting further optimization processes. This parameters are found by calculating of the partial derivatives of a variable in respect to another, in general, voltages, losses and reactive powers. After describing the calculation of the sensibility parameters, the Gradient Method was presented, using these parameters to optimize an objective function, that will be defined for each type of study. The first one refers to the reduction of technical losses in a medium voltage feeder, through the installation of capacitor banks; the second one refers to the problem of correction of voltage profile, through the instalation of capacitor banks or voltage regulators. In case of the losses reduction will be considered, as objective function, the sum of the losses in all the parts of the system. To the correction of the voltage profile, the objective function will be the sum of the square voltage deviations in each node, in respect to the rated voltage. In the end of the work, results of application of the described methods in some feeders are presented, aiming to give insight about their performance and acuity
Resumo:
The usual programs for load flow calculation were in general developped aiming the simulation of electric energy transmission, subtransmission and distribution systems. However, the mathematical methods and algorithms used by the formulations were based, in majority, just on the characteristics of the transmittion systems, which were the main concern focus of engineers and researchers. Though, the physical characteristics of these systems are quite different from the distribution ones. In the transmission systems, the voltage levels are high and the lines are generally very long. These aspects contribute the capacitive and inductive effects that appear in the system to have a considerable influence in the values of the interest quantities, reason why they should be taken into consideration. Still in the transmission systems, the loads have a macro nature, as for example, cities, neiborhoods, or big industries. These loads are, generally, practically balanced, what reduces the necessity of utilization of three-phase methodology for the load flow calculation. Distribution systems, on the other hand, present different characteristics: the voltage levels are small in comparison to the transmission ones. This almost annul the capacitive effects of the lines. The loads are, in this case, transformers, in whose secondaries are connected small consumers, in a sort of times, mono-phase ones, so that the probability of finding an unbalanced circuit is high. This way, the utilization of three-phase methodologies assumes an important dimension. Besides, equipments like voltage regulators, that use simultaneously the concepts of phase and line voltage in their functioning, need a three-phase methodology, in order to allow the simulation of their real behavior. For the exposed reasons, initially was developped, in the scope of this work, a method for three-phase load flow calculation in order to simulate the steady-state behaviour of distribution systems. Aiming to achieve this goal, the Power Summation Algorithm was used, as a base for developping the three phase method. This algorithm was already widely tested and approved by researchers and engineers in the simulation of radial electric energy distribution systems, mainly for single-phase representation. By our formulation, lines are modeled in three-phase circuits, considering the magnetic coupling between the phases; but the earth effect is considered through the Carson reduction. Its important to point out that, in spite of the loads being normally connected to the transformers secondaries, was considered the hypothesis of existence of star or delta loads connected to the primary circuit. To perform the simulation of voltage regulators, a new model was utilized, allowing the simulation of various types of configurations, according to their real functioning. Finally, was considered the possibility of representation of switches with current measuring in various points of the feeder. The loads are adjusted during the iteractive process, in order to match the current in each switch, converging to the measured value specified by the input data. In a second stage of the work, sensibility parameters were derived taking as base the described load flow, with the objective of suporting further optimization processes. This parameters are found by calculating of the partial derivatives of a variable in respect to another, in general, voltages, losses and reactive powers. After describing the calculation of the sensibility parameters, the Gradient Method was presented, using these parameters to optimize an objective function, that will be defined for each type of study. The first one refers to the reduction of technical losses in a medium voltage feeder, through the installation of capacitor banks; the second one refers to the problem of correction of voltage profile, through the instalation of capacitor banks or voltage regulators. In case of the losses reduction will be considered, as objective function, the sum of the losses in all the parts of the system. To the correction of the voltage profile, the objective function will be the sum of the square voltage deviations in each node, in respect to the rated voltage. In the end of the work, results of application of the described methods in some feeders are presented, aiming to give insight about their performance and acuity
Resumo:
The Methods for compensation of harmonic currents and voltages have been widely used since these methods allow to reduce to acceptable levels the harmonic distortion in the voltages or currents in a power system, and also compensate reactive. The reduction of harmonics and reactive contributes to the reduction of losses in transmission lines and electrical machinery, increasing the power factor, reduce the occurrence of overvoltage and overcurrent. The active power filter is the most efficient method for compensation of harmonic currents and voltages. The active power filter is necessary to use current and voltage controllers loop. Conventionally, the current and voltage control loop of active filter has been done by proportional controllers integrative. This work, investigated the use of a robust adaptive control technique on the shunt active power filter current and voltage control loop to increase robustness and improve the performance of active filter to compensate for harmonics. The proposed control scheme is based on a combination of techniques for adaptive control pole placement and variable structure. The advantages of the proposed method over conventional ones are: lower total harmonic distortion, more flexibility, adaptability and robustness to the system. Moreover, the proposed control scheme improves the performance and improves the transient of active filter. The validation of the proposed technique was verified initially by a simulation program implemented in C++ language and then experimental results were obtained using a prototype three-phase active filter of 1 kVA
Resumo:
The giant cell fibroma is a benign neoplasm characterized by the presence of mono, bi or multinucleate cells, which can have a connection to the presence of mast cells. This research aims to analyze, descriptively and comparatively, the immunohystochemistry expression of the tryptase in mast cells of the giant cell f ibroma, f ibrous hyperplasia and samples of the normal oral mucosa. Thirty cases of giant cell fibroma, ten cases of fibrous hyperplasia and ten cases of normal oral mucosa were selected for the analysis of the immunohistochemistry expression, determination of the number of present mast cells, as well as their location and shape. It could be stated that there was a statistically signif icant difference (p<0,001) in relation to the quantity of mast cells among other samples analyzed where the giant cell f ibroma presented lesser quantity of mast cell and the hyperplasia showed higher concentration of this cellular type. Although the oral mucosa has presented a higher quantity of mast cells when compared to the giant cells fibroma, these were found in usual locations in the connective tissue in normal tissues. There could be noticed a statistically significant difference in relation to the number of non-granulated mast cells (p<0,001). On the areas of fibrosis, we could observe a statistically signif icant difference (p<0,006) among the samples. In relation to the present mast cells in perivascular location, no statistically signif icant difference was found. On the morphological analysis there was a predominance of oval mast cells. It was concluded that despite of the fact there was a lesser quantity of mast cells present in cases of giant cell f ibroma, they appeared to have a stronger relation to the present giant fibroblasts in this lesions, around 59,62%, being also evidenced a strong relation between these cells and the fibrosis areas in both cases of giant cell f ibroma and f ibrous hyperplasias and samples of normal oral mucosa, used as control group in our study, confirming, this way, the role of the mast cells as fibrinogenous inductor
Resumo:
The humanity reached a time of unprecedented technological development. Science has achieved and continues to achieve technologies that allowed increasingly to understand the universe and the laws which govern it, and also try to coexist without destroying the planet we live on. One of the main challenges of the XXI century is to seek and increase new sources of clean energy, renewable and able to sustain our growth and lifestyle. It is the duty of every researcher engage and contribute in this race of energy. In this context, wind power presents itself as one of the great promises for the future of electricity generation . Despite being a bit older than other sources of renewable energy, wind power still presents a wide field for improvement. The development of new techniques for control of the generator along with the development of research laboratories specializing in wind generation are one of the key points to improve the performance, efficiency and reliability of the system. Appropriate control of back-to-back converter scheme allows wind turbines based on the doubly-fed induction generator to operate in the variable-speed mode, whose benefits include maximum power extraction, reactive power injection and mechanical stress reduction. The generator-side converter provides control of active and reactive power injected into the grid, whereas the grid-side converter provides control of the DC link voltage and bi-directional power flow. The conventional control structure uses PI controllers with feed-forward compensation of cross-coupling dq terms. This control technique is sensitive to model uncertainties and the compensation of dynamic dq terms results on a competing control strategy. Therefore, to overcome these problems, it is proposed in this thesis a robust internal model based state-feedback control structure in order to eliminate the cross-coupling terms and thereby improve the generator drive as well as its dynamic behavior during sudden changes in wind speed. It is compared the conventional control approach with the proposed control technique for DFIG wind turbine control under both steady and gust wind conditions. Moreover, it is also proposed in this thesis an wind turbine emulator, which was developed to recreate in laboratory a realistic condition and to submit the generator to several wind speed conditions.
Resumo:
The conventional control schemes applied to Shunt Active Power Filters (SAPF) are Harmonic extractor-based strategies (HEBSs) because their effectiveness depends on how quickly and accurately the harmonic components of the nonlinear loads are identified. The SAPF can be also implemented without the use of the load harmonic extractors. In this case, the harmonic compensating term is obtained from the system active power balance. These systems can be considered as balanced-energy-based schemes (BEBSs) and their performance depends on how fast the system reaches the equilibrium state. In this case, the phase currents of the power grid are indirectly regulated by double sequence controllers with two degrees of freedom, where the internal model principle is employed to avoid reference frame transformation. Additionally the DSC controller presents robustness when the SAPF is operating under unbalanced conditions. Furthermore, SAPF implemented without harmonic detection schemes compensate simultaneously harmonic distortion and reactive power of the load. Their compensation capabilities, however, are limited by the SAPF power converter rating. Such a restriction can be minimized if the level of the reactive power correction is managed. In this work an estimation scheme for determining the filter currents is introduced to manage the compensation of reactive power. Experimental results are shown for demonstrating the performance of the proposed SAPF system.
Resumo:
Chronic weight loss in marmosets is often associated with wasting marmoset syndrome (WMS), an important disease that occurs in callitrichid colonies around the world. Even though its etiology is very difficult to determine, particular variables, such as weight loss, diarrhea and alopecia, associated or not with infestation in the pancreatic ducts with Trichospirura leptossoma (Nematoda: Thelazioidea), seem to be linked with the syndrome. This study investigated the histopathology of the lungs, duodenum, liver, gallbladder, extrahepatic bile ducts and pancreatic ducts of six common marmosets (Callithrix jacchus) suffering from severe non-diarrheic weight loss. Three individuals died naturally and the other three were euthanized. Microscopic findings showed the presence of adult flukes (Platynosomum) in the liver. These flukes, which provoke common infection in cats, were also observed inside the gallbladder as well as in the intra and extrahepatic bile ducts in common marmosets. Portal fibrosis was observed in two animals, which developed chronic fibrosing hepatopathy (biliary pattern, grade 3). The disease progresses without diarrhea and without pancreatic lesions or infestation. With the rogression, the animals presented with ascending cholangitis, cholestasis and portal fibrosis, sometimes culminating in secondary biliary cirrhosis. Therefore, this nfirmity, associated with chronic weight loss in common marmosets, could be another tiological factor linked with WMS
Resumo:
American visceral leishmaniasis (AVL), caused by Leishmania infantum chagasi (L.i.chagasi), stands as a public health problem in Brazil, with human and canine cases related in all states..Lipid metabolism can be modified in several status of infection. For example, experimental studies show that the cholesterol is necessary to internalization and replication of L.i.chagasi in macrophages through caveolar domains. Patients with AVL present low levels of cholesterol and a visible triglycerides increase. This work aimed to evaluate the lipid metabolism in several post-infection status by L.i.chagasi, including individuals with symptomatic infection (AVL), and asymptomatic. The levels of cholesterol, triglycerides, HDL and reactive C protein, were measured. Individuals with AVL were compared with individuals with assymptomatic infection and presented low levels of total cholesterol (128 ± 6.180 mg/dL vs. 158 ±5.733 mg/dL, p=0.0001), HDL (29 ± 1.746 mg/dL vs. 37 ± 1.647 mg/dL, p=0.0001), increased levels of triglycerides (149.5 mg/dL ± 12.72 vs. 78.00 ± 10.43 mg/dL, p=0.0095) and higher levels of reactive C protein (1.750± 0.4939 mg/dL vs. 0.40 ± 0.1707 mg/dL; p=0.0001). The expression of genes related to lipid metabolism, such as LXR-a, LXR-b, PPAR-a, PPAR-d, PPAR-g and APOE was evaluated by real time PCR. A reduction in the expression of those genes was found in the group of AVL patients corroborating the serum levels of the metabolites earlier quantified. Our findings suggest a modulation of metabolism of lipids, in the chronic phase of AVL, this could facilitate the survival of leishmania, due to the known reduction on the ability of macrophages in presenting antigens efficiently to the T cells due to the reduction in the cholesterol available, it results in a subversion of the host immunity.