7 resultados para Cortinas de estacas

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experimental study has been conducted to investigate the behavior of continuous flight auger (cfa) bored piles and metalic driven H-section piles under lateral loading in cohesionless soils. The piles were tested in two different areas at the same site. Both areas consisted of a 3-m thick compacted superficial fill of pure fine sand, underlain by layers of naturally occurring pure fine-thick sand. Fills are differentiated by the relative densities which were compressed, 45% e 70%, respectively. Each area received one identical pair of cfa piles and two identical pairs of H-piles. A static lateral loading test was performed in each pair of piles. In this work, the pile load test results are reported and interpreted. The horizontal coefficient of subgrade reaction was determined from the results of the loading tests and compared with values determined by correlations based on penetration resistance index of SPT tests (NSPT). p-y formulations describing the static behavior of the piles were applied to the problem under evaluation. Back Analyses were made through theoretical and experimental p-y curves for obtaining input parameters for the analytic models, among which the coefficient of horizontal reaction. The soil pile system horizontal loading at rupture was determined by the theoretical methods and the results were compared with the experimental results, checking its validity

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is presented the analysis of a retaining wall designed for the basement of a residential building, located in Natal/RN, which consists in a spaced pile wall, anchored by tiebacks, in sand. This structure was instrumented in order to measure the wall s horizontal movements and the load distribution throughout the anchor fixed length. The horizontal movements were measured with an inclinometer, and the loads in the anchors were measured with strain gages, installed in three places throughout the anchor fixed length. Measurements for displacement were done right after the implementation of each stage of the building and right after the conclusion of the building, and the measurements for loads in the anchors were done during the performance test, at the moment of the locking off and, also, right after the conclusion of the building. From the data of displacement were obtained velocity and acceleration data of wall. It was found that the time elapsed on braced installation was decisive in the magnitude of the displacements. The maximum horizontal displacement of wall ranged between 0,18 and 0,66% of the final depth of excavation. The loads in the anchors strongly reduced to approximately half the anchor fixed length, followed an exponential distribution. Furthermore, it was found that there was a loss of load in the anchors over time, reaching 50% loss in one of them

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The piles are one of the most important types of solution adopted for the foundation of buildings. They are responsible for transmitting to the soil in deepe r and resistant layers loads from structures. The interaction of the foundation element with the soil is a very important variable, making indispensable your domain in order to determine the strength of the assembly and establish design criteria for each c ase of application of the pile. In this research analyzes were performed f rom experiments load tests for precast concrete piles and inve stigations of soil of type SPT, a study was performed for obtaining the ultimate load capacity of the foundation through methods extrapolation of load - settlement curve , semi - empirical and theoretic . After that, were realized comparisons between the different methods used for two types of soil a granular behavior and other cohesive. For obtaining soil paramet ers to be used i n the methods were established empirical correlations with the standard penetration number (NSPT). The charge - settlement curves of the piles are also analyzed. In the face of established comparisons was indicated the most reliable semiempirical method Déco urt - Quaresma as the most reliable for estimating the tensile strength for granular and cohesive soils. Meanwhile, among the methods studied extrapolation is recommended method of Van der Veen as the most appropriate for predicting the tensile strength.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Retaining walls design involves factors such as plastification, loading and unloading, pre-stressing, excessive displacements and earth and water thrust. Furthermore, the interaction between the retained soil and the structure is rather complex and hard to predict. Despite the advances in numerical simulation techniques and monitoring of forces and displacements with field instrumentation, design projects are still based on classical methods, whose simplifying assumptions may overestimate structural elements of the retaining wall. This dissertation involves a three-dimensional numerical study on the behavior of a retaining wall using the finite element method (FEM). The retaining wall structure is a contiguous bored pile wall with tie-back anchors. The numerical results were compared to data obtained from field instrumentation. The influence of the position of one or two layers of anchors and the effects of the construction of a slab bounded at the top of the retaining wall was evaluated. Furthermore, this study aimed at investigating the phenomenon of arching in the soil behind the wall. Arching was evaluated by analyzing the effects of pile spacing on horizontal stresses and displacements. Parametric analysis with one layers of anchors showed that the smallest horizontal displacements of the structure were achieved for between 0.3 and 0.5 times the excavation depth. Parametric analyses with two anchor layers showed that the smallest horizontal displacements were achieve for anchors positioned in depths of 0.4H and 0.7H. The construction of a slab at the top of the retaining wall decreased the horizontal displacements by 0.14% times the excavation depth as compared to analyses without the slab. With regard to the arching , analyzes showed an optimal range of spacing between the faces of the piles between 0.4 and 0.6 times the diameter of the pile

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PEDRINI, Aldomar; SZOKOLAY, Steven. Recomendações para o desenvolvimento de uma ferramenta de suporte às primeiras decisões projetuais visando ao desempenho energético de edificações de escritório em clima quente. Ambiente Construído, Porto Alegre, v. 5, n. 1, p.39-54, jan./mar. 2005. Trimestral. Disponível em: . Acesso em: 04 out. 2010.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work the use of coconut fiber (coir) and bamboo shafts as reinforcement of soil-cement was studied, in order to obtain an alternative material to make stakes for fences in rural properties. The main objective was to study the effect of the addition of reinforcement to the soil-cement matrix. The effect of humidity on the mechanical properties was also analyzed. The soil-cement mortar was composed by a mixture, in equal parts, of soil and river sand, 14% in weight of cement and 10 % in weight of water. As reinforcement, different combinations of (a) coconut fiber with 15 mm mean length (0,3 %, 0,6 % and 1,2 % in weight) and (b) bamboo shafts, also in crescent quantities (2, 4 and 8 shafts per specimen) were used. For each combination 6 specimens were made and these were submitted to three point flexural test after 28 days of cure. In order to evaluate the effect of humidity, 1 specimen from each of the coconut fiber reinforced combination was immersed in water 24 hours prior to flexural test. The results of the tests carried out indicated that the addition of the reinforcement affected negatively the mechanical resistance and, on the other hand, increased the tenacity and the ductility of the material.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PEDRINI, Aldomar; SZOKOLAY, Steven. Recomendações para o desenvolvimento de uma ferramenta de suporte às primeiras decisões projetuais visando ao desempenho energético de edificações de escritório em clima quente. Ambiente Construído, Porto Alegre, v. 5, n. 1, p.39-54, jan./mar. 2005. Trimestral. Disponível em: . Acesso em: 04 out. 2010.