3 resultados para Control program
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
The objective of this work - which is characterized analyze the search for symptomatic tuberculosis in practice and perspective of the Community Health Agent (ACS) in the districts of Natal. Methods: This is a cross-sectional study. The study population was 646 professionals, and conducted a probabilistic random sampling, stratified by districts. The data were collected from one instrument to collect data based on Primary Care Assesment Toll (PCAT) and analyzed by descriptive statistics. The sample consisted of ACS was 87% female. Among the study participants 58% completed high school and 120 months of exercise training (95% CI 111.9 to 129.5) on average. 90% were USF. The average follow-up of cases found were 2 cases of TB since the beginning of the career of the ACS and the last three years the average is presented in a case accompanied. The ACS received satisfactory ratings on the bond of trust with the user, so as access to homes in the community. The ACS reported for denying the fear of being positive result was the biggest reason for not performing the sputum. All units have a professional that responds to the Tuberculosis Control Program. Regarding the structural capacity of primary care settings for the diagnosis of TB, we observed satisfactory levels in different districts of pots for sputum collection, however, a point that deserves attention from managers is lack of materials for packaging sputum. Fear of positive result was one of the reasons for the refusal of sputum collection, followed by alcoholism. With regard to TB suspects, all responded that ACS always suspect when the user has TB coughs, but in all districts were noticed at low delivery of requests for applications for smear. BSR in TB control, is characterized in practice as a complex action goes beyond technical expertise and contact with the family that breaks with the Cartesian. The BSR is part of the ACS can perform them from the daily visits. We conclude that the ACS is difficult to achieve. This practice should not be the privilege of this actor, but the entire team of primary care. We must rethink the practices of TB care, seeing the health surveillance while aegis of the working process of primary care teams for early diagnosis and thereby reduce TB in communities
Resumo:
This work presents a proposal for a voltage and frequency control system for a wind power induction generator. It has been developed na experimental structure composes basically by a three phase induction machine, a three phase capacitor and a reactive static Power compensator controlled by histeresys. lt has been developed control algorithms using conventional methods (Pl control) and linguistic methods (using concepts of logic and fuzzy control), to compare their performances in the variable speed generator system. The control loop was projected using the ADJDA PCL 818 model board into a Pentium 200 MHz compu ter. The induction generator mathematical model was studied throught Park transformation. It has been realized simulations in the Pspice@ software, to verify the system characteristics in transient and steady-state situations. The real time control program was developed in C language, possibilish verify the algorithm performance in the 2,2kW didatic experimental system
Resumo:
Relevant researches have been growing on electric machine without mancal or bearing and that is generally named bearingless motor or specifically, mancal motor. In this paper it is made an introductory presentation about bearingless motor and its peripherical devices with focus on the design and implementation of sensors and interfaces needed to control rotor radial positioning and rotation of the machine. The signals from the machine are conditioned in analogic inputs of DSP TMS320F2812 and used in the control program. This work has a purpose to elaborate and build a system with sensors and interfaces suitable to the input and output of DSP TMS320F2812 to control a mancal motor, bearing in mind the modularity, simplicity of circuits, low number of power used, good noise imunity and good response frequency over 10 kHz. The system is tested at a modified ordinary induction motor of 3,7 kVA to be used with a bearingless motor with divided coil