38 resultados para Carga inmediata

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The eutrofization is a natural process of accumulation of nutrients in aquatic´s body that it has been accelerated for the human´s actives, mainly the related with the activities of camp, industrial and the inadequate disposition of the domestic sewage. The enrichment of the aquatic´s body with nutrients, mainly the nitrogen and the phosphorus, and the consequent proliferation of algae and Cyanobacteria can commit the quality of the water for the public provisioning, for the fish farming and for other ends. The problem becomes more critical when there is a shortage of water naturally as in the semi-arid area of the Brazilian northeast. Before that problem this work had as objective evaluates the trophic state of six reservoirs of the basin of River Seridó of Rio Grande of Norte and also estimate the capacity of load of match of the reservoir and risk probabilities based on the established limits by the resolution Conama 357/05. The results demonstrate that the six reservoirs are eutrofization, with concentration of total phosphorus and cloro a in the water upster to 50 e 12 μg l-1. The results show that space homogeneity exists in the state trophic of the reservoirs, but a significant variation interanual in function of the increase of the concentrations of nutrients and decrease of the transparency of the water with the reduction of the body of water accumulated in the reservoirs.The results of the simulation risk estocastic show that the reservoirs could receive annually from 72 to 216 Kg of P, assuming a risk of 10% of increasing in more than 30 μg l-1 the annual medium concentrations of total match in the water of these reservoirs. This load could be high in until 360 kg of P a year in case the managers assume a risk of 10% of increasing in more than 50 μg l-1 the annual medium concentrations of total phosphorus in the waters of these reservoirs

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The oil companies in the area in general are looking for new technologies that can increase the recovery factor of oil contained in reservoirs. These investments are mainly aimed at reducing the costs of projects which are high. Steam injection is one of these special methods of recovery in which steam is injected into the reservoir in order to reduce the viscosity of the oil and make it more mobile. The process assisted gravity drainage steam (SAGD) using steam injection in its mechanism, as well as two parallel horizontal wells. In this process steam is injected through the horizontal injection well, then a vapor chamber is formed by heating the oil in the reservoir and, by the action of gravitational forces, this oil is drained down to where the production well. This study aims to analyze the influence of pressure drop and heat along the injection well in the SAGD process. Numerical simulations were performed using the thermal simulator STARS of CMG (Computer Modeling Group). The parameters studied were the thermal conductivity of the formation, the flow of steam injection, the inner diameter of the column, the steam quality and temperature. A factorial design was used to verify the influence of the parameters studied in the recovery factor. We also analyzed different injection flow rates for the model with pressure drop and no pressure drop, as well as different maximum flow rates of oil production. Finally, we performed an economic analysis of the two models in order to check the profitability of the projects studied. The results showed that the pressure drop in injection well have a significant influence on the SAGD process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nowadays, most of the hydrocarbon reserves in the world are in the form of heavy oil, ultra - heavy or bitumen. For the extraction and production of this resource is required to implement new technologies. One of the promising processes for the recovery of this oil is the Expanding Solvent Steam Assisted Gravity Drainage (ES-SAGD) which uses two parallel horizontal wells, where the injection well is situated vertically above the production well. The completion of the process occurs upon injection of a hydrocarbon additive at low concentration in conjunction with steam. The steam adds heat to reduce the viscosity of the oil and solvent aids in reducing the interfacial tension between oil/ solvent. The main force acting in this process is the gravitational and the heat transfer takes place by conduction, convection and latent heat of steam. In this study was used the discretized wellbore model, where the well is discretized in the same way that the reservoir and each section of the well treated as a block of grid, with interblock connection with the reservoir. This study aims to analyze the influence of the pressure drop and heat along the injection well in the ES-SAGD process. The model used for the study is a homogeneous reservoir, semi synthetic with characteristics of the Brazilian Northeast and numerical simulations were performed using the STARS thermal simulator from CMG (Computer Modelling Group). The operational parameters analyzed were: percentage of solvent injected, the flow of steam injection, vertical distance between the wells and steam quality. All of them were significant in oil recovery factor positively influencing this. The results showed that, for all cases analyzed, the model considers the pressure drop has cumulative production of oil below its respective model that disregards such loss. This difference is more pronounced the lower the value of the flow of steam injection

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To aureus α-HL channel, we used the cysteine-scanning mutagenesis technique. Twenty-four mutants were produced from the substitution of a single aminoacid of the primary structure of the α-HL pro this yzed after the incorporation of a mutant channel in planar lipid bilayer membranes. The modified proteins were studied in the absence and presence of watersoluble specific sulphydryl-specific reagents, in order to introduce a strong positive or negative harge at positions of substitution. The introduction of a negative charge in the stem region onverted the selectivity of the channel from weak anionic to more cationic. However, the troduction of a positive charge increased its selectivity to the anion. The degree of these alterations was inversely dependent on the channel radius at the position of the introduced harge (selectivity). As to the asymmetry of the conductance-voltage, the influence of the harge was more complex. The introduction of the negative charge in the stem region (the trans art of the pore) provoked a decrease. The intensity of these alterations depended on the radius, and on the type of free charge at the pore entrance. These results suggest that the free charge at surrounds the pore wall is responsible for the cation-anion selectivity of the channel. The istribution of the charges between the entrances is crucial for determining the asymmetry of e conductance-voltage curves. We hope that these results serve as a model for studies with other nanometric channels, in biological or planar lipid bilayer membranes or in iotechnological applications

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent decades, the search for quality care has been widely discussed by the institutions and health professionals. In this context, it is the nurse coordinator of the process of providing nursing staff, reflecting the commitment to quality of care. In this process, it is the appearance of Infections Related to health care and its potential association with the workload in nursing as a valuable indicator of quality of care. Thus, this research contributes to studies to characterize the demand of nursing work to promote a safe healthcare practice. This study aimed to identify the association of nursing workload with the number of cases of Ventilator-Associated Pneumonia, urinary tract infection and central venous catheter infection in the intensive care unit. This is a quantitative research approach, descriptive, cross-sectional and prospective, held at Unimed Hospital in Natal-RN. The study population consisted of all patients treated in the Intensive Care Unit, Hospital for a period of 90 consecutive days in 2011. The convenience sample was compostapelos patients admitted to the ICU during the period of data collection, a total sample of 286 patients. To perform the data analysis software were used: Statistica 6.0, SPPS (Statistical Package for Social Sciences) version 17.0 (2004) and Excel 2007. In the descriptive analysis, we used Measures of Central Tendency and Measures of Dispersion or Variability and the use of nonparametric tests. Of the 286 patients, 88 were from the ICU and 198 ICU II II. Males predominated in the ICU I (51.1%) and female ICU II (57.6%) patients in the ICU I were aged 61-80 years (39.8%) followed by greater than 80 years (39.8%). In the ICU II, most of the patients were aged 61-80 years (38.9%) and then from 41 to 60 years (24.2%). In relation to the class of TISS inlet predominant class II in the two ICUs (59.1%), followed by Class III also in the two units (34.6%). Most patients (70.6%) out of the ICUs belonging to class II TISS. In the ICU I, the average number of forms of the TISS 28 was 6, has in ICU II this value drops to 3.2 forms. The overall mean was 19.9 TISS points in ICU patients I and ICU II.the 17 points in the average hours required to provide adequate nursing care to patients in the ICU I found that is 10 , 7 hours, and the ICU II 9.2 hours. It was found that the time provided by the nursing staff were higher in ICU II, with an average of 19 hours available for nurses in this sector. In the ICU I, which showed higher need of available hours, it was found that the mean value of 12.7 available hours. It was found that only 2.4% of patients had these units Ventilator-Associated Pneumonia, 1.0% were infected central venous catheter and 1.4% of patients had urinary tract infection. Infection associated with health care occurs, on average, on the tenth day of hospitalization. In the ICU II, this average value extends to the twelfth day with an excess of 2.7 hours of nursing care while in ICU I value decays to the ninth day of hospitalization with a deficiency of 12-hour assistance. It is concluded that patients generally showed a need for classification of semi-intensive care and has been assisted in their need to load. As for his association with the Related Infections Health will assist this analysis could not be performed due to the small number of notifications in this period. It is suggested further study how other factors related to infections me a longer period of analysis

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents results of field and laboratory tests using a Dynamic Cone Penetrometer, DCP. The tests were performed in order to evaluate the use of the equipment in sand for the control of bearing capacity of shallow foundations and fill compaction. For shallow foundations, the laboratory tests were conducted on sand placed in a metallic mould by the method of sand pluviation. Although the results show the inability to reproduce field conditions in the laboratory it was possible to verify the ability of the DCP to identify less resistant soil layers. The DCP tests for the analysis of compaction control were performed in a strong box with inside dimensions of 1,40 m x 1,40 m and 0,70 m in height. The soil layers were compacted with different densities though the use of a vibrating plate in order to obtain correlations between penetration index, DPI, and soil relative density. Other tests were also conducted to assess the influence of soil moisture on tests results. Among other findings, the results showed the great potential for the use of DCP to control the compaction of sand fills

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experimental study has been conducted to investigate the behavior of continuous flight auger (cfa) bored piles and metalic driven H-section piles under lateral loading in cohesionless soils. The piles were tested in two different areas at the same site. Both areas consisted of a 3-m thick compacted superficial fill of pure fine sand, underlain by layers of naturally occurring pure fine-thick sand. Fills are differentiated by the relative densities which were compressed, 45% e 70%, respectively. Each area received one identical pair of cfa piles and two identical pairs of H-piles. A static lateral loading test was performed in each pair of piles. In this work, the pile load test results are reported and interpreted. The horizontal coefficient of subgrade reaction was determined from the results of the loading tests and compared with values determined by correlations based on penetration resistance index of SPT tests (NSPT). p-y formulations describing the static behavior of the piles were applied to the problem under evaluation. Back Analyses were made through theoretical and experimental p-y curves for obtaining input parameters for the analytic models, among which the coefficient of horizontal reaction. The soil pile system horizontal loading at rupture was determined by the theoretical methods and the results were compared with the experimental results, checking its validity

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present work is develop a model to simulate electrical energy networks in transient and stead states, using the software ATP (Alternative Transient Program), able to be a way to join two distinct themes, present in classical methodology planning networks: short circuit analysis and load flow theory. Beyond that, using a tool for relay simulation, this paper intend to use the new developed model to investigate the influence of transient phenomenon in operation of protection relays, and calibrate the enterprise's protections relays. For testing the model, some relays, actually, installed at COSERN were used

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work has as main objective to show all the particularities regarding the Three-phase Power Summation Method, used for load flow calculation, in what it says respect to the influence of the magnetic coupling among the phases, as well as to the losses presented in all the existent transformers in the feeder to be analyzed. Besides, its application is detailed in the study of the short-circuits, that happen in the presence of high impedance values, which possess a problem, that is its difficult detection and consequent elimination on the part of common devices of protection. That happens due to the characteristic presented by the current of short¬ circuit, in being generally of the same order of greatness that the load currents. Results of simulations accomplished in several situations will be shown, objectifying a complete analysis of the behavior of the proposed method in several types of short-circuits. Confront of the results obtained by the method with results of another works will be presented to verify its effectiveness

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study were conducted experimental procedures for determination of variation of the expandability of rigid polyurethane foam (PUR) from a natural oil polyol (NOP), specifically the Castor oil plant, Ricinus communis, pure and additions of the vermiculite in phase dispersed in different percentage within a range from 0% to 20%, mass replacement. From the information acquired, were defined the parameters for production of bodies of test, plates obtained through controlled expansion, with the final volume fixed. Initially, the plates were subjected to thermal performance tests and evaluated the temperature profiles, to later be extracted samples duly prepared in accordance with the conditions required for each test. Was proceeded then the measurement of the coefficient of thermal conductivity, volumetric capacity heat and thermal diffusivity. The findings values were compared with the results obtained in the tests of thermal performance, contributing to validation of the same. Ultimately, it was investigated the influence that changes in physical-chemical structure of the material had exerted on the variation of thermophysical quantities through gas pycnometry, scanning electron microscopy (SEM) combined with energy dispersive X-ray fluorescence spectroscopy (EDXRF), infrared spectroscopy using Fourier transform (FTIR), thermogravimetric analysis (TGA) and differential thermal analysis (DTA). Based on the results obtained was possible to demonstrate that all load percentage analyzed promoted an increase in the potential expansion (PE) of the resin. In production of the plates, the composites with density near at the free expansion presented high contraction during the cure, being the of higher density adopted as definitive standard. In the thermal performance tests, the heating and cooling curves of the different composites had presented symmetry and values very close for lines of the temperature. The results obtained for the thermophysical properties of composites, showed little difference in respect of pure foam. The percentage of open pores and irregularities in the morphology of the composites were proportionate to the increment of vermiculite. In the interaction between the matrix and dispersed phase, there were no chemical transformations in the region of interface and new compounds were not generated. The composites of PUR-NOP and vermiculite presented thermal insulating properties near the foam pure and percentage significantly less plastic in its composition, to the formulation with 10% of load

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the execution of civil engineering works, either by wasting during the coating of wall or demolition of gypsum walls, the generation of the gypsum waste involves serious environmental concerns. These concerns are increased by the high demand of this raw material in the sector and by the difficulties of proper disposal byproduct generated. In the search for alternatives to minimize this problem, many research works are being conducted, giving emphasis in using gypsum waste as fillers in composites materials in order to improve the acoustic, thermal and mechanical performances. Through empirical testing, it was observed that the crystallization water contained in the residue (CaSO4.2H2O) could act like primary agent in the expanding of the polyurethane foam. Considering that polyurethane produced from vegetable oils are biodegradable synthetic polymers and that are admittedly to represent an alternative to petrochemical synthetic polyurethane, this research consist an analysis of the thermal behavior of a composite whose matrix obtained from a resin derived from the expansive castor oil seed, with loads of 4%, 8%, 12% and 16% of gypsum waste replacing to the polyol prepolymer blend. Contributors to this analysis: a characterization of the raw material through analysis of spectroscopy by Fourier transform infrared (FTIR), chemical analysis by X-Ray Fluorescence (XRF) and mineralogical analysis by X Ray Diffraction (XRD), complemented by thermo gravimetric analysis (TGA). In order to evaluate the thermo physical properties and thermal behavior of the composites manufactured in die closed with expansion contained, were also carried tests to determine the percentage of open pore volume using a gas pycnometer, scanning electronic microscopy (SEM), in addition to testing of flammability and the resistance to contact with hot surfaces. Through the analysis of the results, it appears that it is possible to produce a new material, which few changes in their thermo physical properties and thermal performance, promotes significant changes and attractive to the environment

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The standardization of the bovine skin thickness in the leather industry generates a residue known as wet-blue . At the end of twentieth century, the brazilian industry discarded about 131 thousand tons of this residue in nature, provoking a great environmental liability. In this paper is presented the analyses of the termophysical properties, thermal and volumetric expansion performance of a composite of vegetable resin of castor oil plant (Ricinus communis) with load of industrial residue of leather "wet-blue", for application as thermal isolation material of warm surfaces. There were considered four percentile levels of residue load in the proportions in mass of 0%, 5%, 10% and 15%, added to the expansible resin of castor oil plant in two configurations: sawed leather and crushed leather in a smaller particle (powder) by grinding in a mill of balls. Twenty-one proof bodies were produced for termophysical properties analysis (three for each configuration) and four proof bodies for rehearsals of thermal acting. Analyses of thermal acting were done in test cameras. The results of the rehearsals were compared to those obtained considering the castor oil plant foam without residue addition. A small reduction of the thermal conductivity of the composite was observed in the proportion of 10% of leather residue in both configurations. Regarding thermal conductivity, calorific capacity and diffusivity, it was verified that the proposed composite showed very close values to the commercial insulating materials (glass wool, rock wool, EPS). It was still demonstrated the technical viability of the use of composite as insulating thermal for systems of low potency. The composite presented larger volumetric expansion with 15% of sawed residue of leather.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of composite materials and alternative is being increased every day, as it becomes more widespread awareness that the use of renewable and not harmful to the environment is part of a new environmentally friendly model. Since its waste (primarily fiberglass) can not be easily recycled by the difficulty that still exists in this process, since they have two phases mixed, a polymeric matrix thermoset difficult to recycle because it is infusible and phase of fiber reinforcements. Thermoset matrix composites like Polyester + fiberglass pose a threat due to excessive discharge. Aiming to minimize this problem, aimed to reuse the composite Polyester + fiber glass, through the wastes obtained by the grinding of knifes and balls. These residues were incorporated into the new composite Polyester/Fiberglass for hot compression mold and compared tribological to composites with filler CaCO3, generally used as filler, targeting a partial replacement of CaCO3 by such waste. The composites were characterized by thermal analysis (TGA, DSC and DMA), by the surface integrity (roughness determination, contact angle and surface energy), mechanical properties (hardness) and tribological tests (wear and coefficient of dynamic friction) in order to evaluate the effect of loads and characterize these materials for applications that can take, in the tribological point of view since waste Polyester + fiberglass has great potential for replacement of CaCO3