10 resultados para Bang-bang Pll
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
Analysis of the northeastern sugar economy insertion on the modernization process of these economy based on the José Lins do Rego literary Discourse. In order to do so, there were used the literary works Fogo Morto, Menino de Engenho, Bangüê and Usina as study objects. Throughout the prosecution of a exploratory and documental bibliographic research it was identified that, in the cited literary works, there are three specialties corresponding to the main scenarios of the plots, the Santa Fé and Santa Rosa mills and the Bom Jesus mill factory. We have conceived the mills as main charachters, since all stories deployment corresponds to the other charachters reactions to the many forms that the specialties are, or not, affected by the modernization. Therefore, the narratives in Fogo Morto, Menino de Engenho, Bangüê and Usina reaffirm the viability of the literary discourse application as a source for the construction of the sociological interpretation of the northeastern sugar economy process of modernization in the end of 19th century and beginning of the 20th century
Resumo:
In this work, we present a theoretical study of the propagation of electromagnetic waves in multilayer structures called Photonic Crystals. For this purpose, we investigate the phonon-polariton band gaps in periodic and quasi-periodic (Fibonacci-type) multilayers made up of both positive and negative refractive index materials in the terahertz (THz) region. The behavior of the polaritonic band gaps as a function of the multilayer period is investigated systematically. We use a theoretical model based on the formalism of transfer matrix in order to simplify the algebra involved in obtaining the dispersion relation of phonon-polaritons (bulk and surface modes). We also present a quantitative analysis of the results, pointing out the distribution of the allowed polaritonic bandwidths for high Fibonacci generations, which gives good insight about their localization and power laws. We calculate the emittance spectrum of the electromagnetic radiation, in THZ frequency, normally and obliquely incident (s and p polarized modes) on a one-dimensional multilayer structure composed of positive and negative refractive index materials organized periodically and quasi-periodically. We model the negative refractive index material by a effective medium whose electric permittivity is characterized by a phonon-polariton frequency dependent dielectric function, while for the magnetic permeability we have a Drude like frequency-dependent function. Similarity to the one-dimensional photonic crystal, this layered effective medium, called polaritonic Crystals, allow us the control of the electromagnetic propagation, generating regions named polaritonic bandgap. The emittance spectra are determined by means of a well known theoretical model based on Kirchoff s second law, together with a transfer matrix formalism. Our results shows that the omnidirectional band gaps will appear in the THz regime, in a well defined interval, that are independent of polarization in periodic case as well as in quasiperiodic case
Resumo:
Lithium (Li) is a chemical element with atomic number 3 and it is among the lightest known elements in the universe. In general, the Lithium is found in the nature under the form of two stable isotopes, the 6Li and 7Li. This last one is the most dominant and responds for about 93% of the Li found in the Universe. Due to its fragileness this element is largely used in the astrophysics, especially in what refers to the understanding of the physical process that has occurred since the Big Bang going through the evolution of the galaxies and stars. In the primordial nucleosynthesis in the Big Bang moment (BBN), the theoretical calculation forecasts a Li production along with all the light elements such as Deuterium and Beryllium. To the Li the BNB theory reviews a primordial abundance of Log log ǫ(Li) =2.72 dex in a logarithmic scale related to the H. The abundance of Li found on the poor metal stars, or pop II stars type, is called as being the abundance of Li primordial and is the measure as being log ǫ(Li) =2.27 dex. In the ISM (Interstellar medium), that reflects the current value, the abundance of Lithium is log ǫ(Li) = 3.2 dex. This value has great importance for our comprehension on the chemical evolution of the galaxy. The process responsible for the increasing of the primordial value present in the Li is not clearly understood until nowadays. In fact there is a real contribution of Li from the giant stars of little mass and this contribution needs to be well streamed if we want to understand our galaxy. The main objection in this logical sequence is the appearing of some giant stars with little mass of G and K spectral types which atmosphere is highly enriched with Li. Such elevated values are exactly the opposite of what could happen with the typical abundance of giant low mass stars, where convective envelops pass through a mass deepening in which all the Li should be diluted and present abundances around log ǫ(Li) ∼1.4 dex following the model of stellar evolution. In the Literature three suggestions are found that try to reconcile the values of the abundance of Li theoretical and observed in these rich in Li giants, but any of them bring conclusive answers. In the present work, we propose a qualitative study of the evolutionary state of the rich in Li stars in the literature along with the recent discovery of the first star rich in Li observed by the Kepler Satellite. The main objective of this work is to promote a solid discussion about the evolutionary state based on the characteristic obtained from the seismic analysis of the object observed by Kepler. We used evolutionary traces and simulation done with the population synthesis code TRILEGAL intending to evaluate as precisely as possible the evolutionary state of the internal structure of these groups of stars. The results indicate a very short characteristic time when compared to the evolutionary scale related to the enrichment of these stars
Resumo:
Many astronomical observations in the last few years are strongly suggesting that the current Universe is spatially flat and dominated by an exotic form of energy. This unknown energy density accelerates the universe expansion and corresponds to around 70% of its total density being usually called Dark Energy or Quintessence. One of the candidates to dark energy is the so-called cosmological constant (Λ) which is usually interpreted as the vacuum energy density. However, in order to remove the discrepancy between the expected and observed values for the vacuum energy density some current models assume that the vacuum energy is continuously decaying due to its possible coupling with the others matter fields existing in the Cosmos. In this dissertation, starting from concepts and basis of General Relativity Theory, we study the Cosmic Microwave Background Radiation with emphasis on the anisotropies or temperature fluctuations which are one of the oldest relic of the observed Universe. The anisotropies are deduced by integrating the Boltzmann equation in order to explain qualitatively the generation and c1assification of the fluctuations. In the following we construct explicitly the angular power spectrum of anisotropies for cosmologies with cosmological constant (ΛCDM) and a decaying vacuum energy density (Λ(t)CDM). Finally, with basis on the quadrupole moment measured by the WMAP experiment, we estimate the decaying rates of the vacuum energy density in matter and in radiation for a smoothly and non-smoothly decaying vacuum
Resumo:
Chronic lymphoproliferative disorders (DLPC) are lymphoid system diseases characterized by the abnormal proliferation of mature lymphocytes that affect B cells, T lymphocytes and NK cells. The aim of the study was to demonstrate the relevance of immunophenotyping by flow cytometry in patients with prolonged lymphocytosis and / or cytomorphological changes compatible with lymphoproliferative diseases. In this study 460 patients (244 men and 216 women) with DLPC were evaluated. Were analyzed by flow cytometry with a panel of monoclonal antibodies consisting of CD3, CD4, CD5, CD8, CD10, CD19, CD22, CD23, CD25, CD38, CD45, CD16/CD56, and HLADR heavy and light chains of immunoglobulins. It also examines information regarding age, gender of patients and laboratory data as leucocytes, cytomorphological analysis, platelet count and hemoglobin determination. The results showed 398 cases of chronic lymphoproliferative disorders and 62 of DLPC B cell lymphoproliferative diseases T. B showed the following distribution : 253 cases of chronic lymphocytic leukemia (CLL), 42 cases of multiple myeloma ( MM ), 37 cases of lymphoma non - Hodgkin lymphoma in leukemic phase (NHL) , 17 cases of pro- B lymphocytic leukemia ( B -PLL), 15 cases of mantle cell lymphoma (MCL ), 12 cases of plasma cell leukemia ( PCL), 9 cases of lymphoma Burkitt (Linf B), 8 cases of leukemia villous cells ( LCV), 3 cases of splenic lymphoma with villous cells (LECV), a case of follicular lymphoma (LF) and a Waldenströn macroglobulinemia ( MW). The diseases source NK / T were 23 cases of peripheral T cell lymphoma (LCTP), 14 cases of T prolymphocytic leukemia (T -PLL), 10 cases of leukemia T of large granular lymphocytes (LGL -T) 9 cases of leukemia cells of adult T (LCTA), 5 cases of Sezary syndrome (SS) and a case of large granular NK leukemia (LGL -NK) lymphocytes. In conclusion, the combined use of the monoclonal antibody panel careful cytomorphological analysis was shown to be essential in immune diagnosis and classification of chronic lymphoproliferative disorders. This study was approved by the IRB - HUOL under number 356 / 09
Resumo:
This work describes the study, the analysis, the project methodology and the constructive details of a high frequency DC/AC resonant series converter using sequential commutation techniques for the excitation of an inductive coupled thermal plasma torch. The aim of this thesis is to show the new modulation technique potentialities and to present a technological option for the high-frequency electronic power converters development. The resonant converter operates at 50 kW output power under a 400 kHz frequency and it is constituted by inverter cells using ultra-fast IGBT devices. In order to minimize the turn-off losses, the inverter cells operates in a ZVS mode referred by a modified PLL loop that maintains this condition stable, despite the load variations. The sequential pulse gating command strategy used it allows to operate the IGBT devices on its maximum power limits using the derating and destressing current scheme, as well as it propitiates a frequency multiplication of the inverters set. The output converter is connected to a series resonant circuit constituted by the applicator ICTP torch, a compensation capacitor and an impedance matching RF transformer. At the final, are presented the experimental results and the many tests achieved in laboratory as form to validate the proposed new technique
Resumo:
Conventional control strategies used in shunt active power filters (SAPF) employs real-time instantaneous harmonic detection schemes which is usually implements with digital filters. This increase the number of current sensors on the filter structure which results in high costs. Furthermore, these detection schemes introduce time delays which can deteriorate the harmonic compensation performance. Differently from the conventional control schemes, this paper proposes a non-standard control strategy which indirectly regulates the phase currents of the power mains. The reference currents of system are generated by the dc-link voltage controller and is based on the active power balance of SAPF system. The reference currents are aligned to the phase angle of the power mains voltage vector which is obtained by using a dq phase locked loop (PLL) system. The current control strategy is implemented by an adaptive pole placement control strategy integrated to a variable structure control scheme (VS-APPC). In the VS-APPC, the internal model principle (IMP) of reference currents is used for achieving the zero steady state tracking error of the power system currents. This forces the phase current of the system mains to be sinusoidal with low harmonics content. Moreover, the current controllers are implemented on the stationary reference frame to avoid transformations to the mains voltage vector reference coordinates. This proposed current control strategy enhance the performance of SAPF with fast transient response and robustness to parametric uncertainties. Experimental results are showing for determining the effectiveness of SAPF proposed control system
Resumo:
Conventional control strategies used in shunt active power filters (SAPF) employs real-time instantaneous harmonic detection schemes which is usually implements with digital filters. This increase the number of current sensors on the filter structure which results in high costs. Furthermore, these detection schemes introduce time delays which can deteriorate the harmonic compensation performance. Differently from the conventional control schemes, this paper proposes a non-standard control strategy which indirectly regulates the phase currents of the power mains. The reference currents of system are generated by the dc-link voltage controller and is based on the active power balance of SAPF system. The reference currents are aligned to the phase angle of the power mains voltage vector which is obtained by using a dq phase locked loop (PLL) system. The current control strategy is implemented by an adaptive pole placement control strategy integrated to a variable structure control scheme (VS¡APPC). In the VS¡APPC, the internal model principle (IMP) of reference currents is used for achieving the zero steady state tracking error of the power system currents. This forces the phase current of the system mains to be sinusoidal with low harmonics content. Moreover, the current controllers are implemented on the stationary reference frame to avoid transformations to the mains voltage vector reference coordinates. This proposed current control strategy enhance the performance of SAPF with fast transient response and robustness to parametric uncertainties. Experimental results are showing for determining the effectiveness of SAPF proposed control system
Resumo:
Atualmente há uma grande preocupação em relação a substituição das fontes não renováveis pelas fontes renováveis na geração de energia elétrica. Isto ocorre devido a limitação do modelo tradicional e da crescente demanda. Com o desenvolvimento dos conversores de potência e a eficácia dos esquemas de controle, as fontes renováveis têm sido interligadas na rede elétrica, em um modelo de geração distribuída. Neste sentido, este trabalho apresenta uma estratégia de controle não convencional, com a utilização de um controlador robusto, para a interconexão de sistemas fotovoltaicos com à rede elétrica trifásica. A compensação da qualidade de energia no ponto de acoplamento comum (PAC) é realizada pela estratégia proposta. As técnicas tradicionais utilizam detecção de harmônicos, já neste trabalho o controle das correntes é feita de uma forma indireta sem a necessidade desta detecção. Na estratégia indireta é de grande importância que o controle da tensão do barramento CC seja efetuado de uma forma que não haja grandes flutuações, e que a banda passante do controlador em regime permanente seja baixa para que as correntes da rede não tenham um alto THD. Por este motivo é utilizado um controlador em modo dual DSM-PI, que durante o transitório se comporta como um controlador em modo deslizante SM-PI, e em regime se comporta como um PI convencional. A corrente é alinhada ao ângulo de fase do vetor tensão da rede elétrica, obtido a partir do uso de um PLL. Esta aproximação permite regular o fluxo de potência ativa, juntamente com a compensação dos harmônicos e também promover a correção do fator de potência no ponto de acoplamento comum. Para o controle das correntes é usado um controlador dupla sequencia, que utiliza o princípio do modelo interno. Resultados de simulação são apresentados para demonstrar a eficácia do sistema de controle proposto
Resumo:
Generation systems, using renewable sources, are becoming increasingly popular due to the need for increased use of electricity. Currently, renewables sources have a role to cooperate with conventional generation, due to the system limitation in delivering the required power, the need for reduction of unwanted effects from sources that use fossil fuels (pollution) and the difficulty of building new transmission and/or distribution lines. This cooperation takes place through distributed generation. Therefore, this work proposes a control strategy for the interconnection of a PV (Photovoltaic) system generation distributed with a three-phase power grid through a connection filter the type LCL. The compensation of power quality at point of common coupling (PCC) is performed ensuring that the mains supply or consume only active power and that his currents have low distorcion. Unlike traditional techniques which require schemes for harmonic detection, the technique performs the harmonic compensation without the use of this schemes, controlling the output currents of the system in an indirect way. So that there is effective control of the DC (Direct Current) bus voltage is used the robust controller mode dual DSMPI (Dual-Sliding Mode-Proportional Integral), that behaves as a sliding mode controller SM-PI (Sliding Mode-Proportional Integral) during the transition and like a conventional PI (Proportional Integral) in the steady-state. For control of current is used to repetitive control strategy, which are used double sequence controllers (DSC) tuned to the fundamental component, the fifth and seventh harmonic. The output phase current are aligned with the phase angle of the utility voltage vector obtained from the use of a SRF-PLL (Synchronous Reference Frame Phase-Locked-Loop). In order to obtain the maximum power from the PV array is used a MPPT (Maximum Power Point Tracking) algorithm without the need for adding sensors. Experimental results are presented to demonstrate the effectiveness of the proposed control system.