17 resultados para BLOQUEO NEUROMUSCULAR-METODOS

em Universidade Federal do Rio Grande do Norte(UFRN)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Changes introduced by cardiopulmonar and neuromuscular training on basal serum insulin-like grow factor-1 (IGF-1) and cortisol levels, functional autonomy and quality of life in elderly women The aim of this study was to compare the effects of strength and aerobic training on basal serum IGF-1 and Cortisol levels, functional autonomy (FA) and quality of life (QoL) in elderly women after 12 weeks of training. The subjects were submitted the strength training (75-85% 1-RM) with weight exercises (SG; n=12; age=66.08 ± 3,37 years; BMI=26,77 ± 3,72 kg/m2), aerobic training with aquatic exercises (AG; n=13; age=68,69 ± 4,70 years; BMI=29,19 ± 2,96 kg/m2) and control group (CG; n=10; age=68,80 ± 5,41 years; BMI=29,70 ± 2,82 kg/m2). Fasting blood was analyzed to measure basal IGF-1 and cortisol levels by chemiluminescence method. The t-Student test showed increased IGF-1 in the SG (p<0.05) for intragroup comparison. The Repeated-measure ANOVA presented increased IGF-1 (p<0.05) in the SG compared to the other two groups. There were no differences in cortisol levels. All the FA tests (GDLAM autonomy protocol) presented decreased significant in the time marked in seconds to the SG. The same results were found in the AG, except in the rise from a sitting position test. The autonomy index presented significant improvements (p<0.05) in the SG related to the AG and CG and in the AG to the CG. The SG showed increased QoL (p<0.05) (by WHOQOL-Old questionnaire) in the facet 1 (sensorial functioning) and facet 5 (death and dying). Thus, the SG obtained positive changes on IGF-1 and FA levels when compared to the AG. This suggests that strength training can indicated to decrease the effects of ageing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A laserterapia de baixa potência (LBP) tem demonstrado recentemente ser capaz de aumentar a resistência à fadiga, bem como potencializar o desempenho neuromuscular através de seus efeitos metabólicos e fotoquímicos. Estudos anteriores mostraram que o LBP reduziu o estresse oxidativo do exercício, promovendo um retardo da fadiga muscular e minimizando seus efeitos deletérios. O objetivo desse estudo foi avaliar se a aplicação do LBP antes de um protocolo de fadiga teria efeito sobre o desempenho neuromuscular nas variáveis eletromiográficas e dinamométricas do músculo sóleo em sujeitos saudáveis. Esta pesquisa caracterizou-se como um estudo experimental do tipo ensaio clínico controlado, randomizado e cego, no qual participaram 60 voluntários de ambos os sexos, com faixa etária entre 18 e 28 anos e fisicamente ativos, segundo o questionário internacional para a prática de atividade física (IPAQ). Os sujeitos foram alocados randomicamente em três grupos: Controle (G1), Placebo (G2) e Laser (G3) e todos os voluntários foram submetidos a uma avaliação inicial (AV-1), um Protocolo de Fadiga e uma avaliação final (AV-2), compostas por contrações isocinéticas para flexão plantar a uma velocidade de 90°/s. Os resultados encontrados nesse estudo mostraram que não houve diferença estatística entre os três grupos da pesquisa nas variáveis eletromiográficas de RMS e Frequência Mediana, contudo, em relação à dinamometria, o grupo que recebeu a aplicação do Laser obteve um índice de fadiga significativamente menor (p=0,04) quando comparado aos grupos Controle e Placebo. Além disso, a aplicação do laser pré-exercício também resultou em um aumento nas variáveis de desempenho potência e trabalho. Com isso, pode-se concluir que o LBP foi capaz de melhorar o desempenho do sóleo em sujeitos saudáveis, justificado pelo aumento da resistência à fadiga

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patellofemoral pain syndrome (PFPS) is described as anterior or retropatellar pain knee in the absence of other pathologies and is frequently associated with dysfunction of the vastus medialis oblique (VMO). However, several studies have demonstrated the inability to selectively activate this muscle through exercise. To evaluate the effect of Neuromuscular Electrical Stimulation (NMES) selective VMO in women with syndrome. We evaluated thirty-eight women: twenty in the control group (24.15 ± 2.60 years) and eighteen diagnosed with PFPS (25.56 ± 3.55 years). Both groups were evaluated before and after a protocol of electro stimulation. To measure for comparing groups before and after treatment, we assessed the extensor torque concentric and eccentric knee through an isokinetic dynamometer, the intensity (Root Mean Square - RMS) and the onset of activation (onset) of VMO compared to the vastus lateralis (VL) in two types of exercise: open and closed kinetic chain. . Statistical analysis was performed using SPSS 15.0, with a significance level of 5%. Results: Our data showed an increase in the intensity of activation (RMS) of the VMO muscle after NMES in both study groups. During concentric contraction the RMS of the VMO before the NMES was 105.69 ± 32.26 μV and after a single intervention was 122.10 ± 39.62 μV (p = 0.048) for the control group. In the group with PPS, we found a similar behavior, with RMS of the VMO before NMES of 96.25 ± 18.83 μV and 139.80 ± 65.88 μV after the intervention (p = 0.0001). However, there was no evidence in the RMS value of VL muscle. The onset was calculated by subtracting the onset of VL by the onset of VMO. For the group with PFPS, the onset before the intervention was -0.007 ± 0.14 ms, indicating a delay of the VMO relative to VL, and after NMES was 0.074 ± 0.09 ms (p = 0.016), showing an activation previous VMO to VL. The same occurred for the control group. We also observed that NMES increased knee extensor power during the concentric contraction in both groups. Before the intervention the mean power was 28.97 ± 9.01 W for the PPS group and after NMES was 34.38 ± 7.61 W (p = 0.0001). Conclusion: We observed an increase in electromyographic activity of the VMO and also an anticipatory effect of this muscle

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Muscle fatigue is a phenomenon that promotes physiological and biomechanical disorders and their changes in healthy subjects have been widely studied and have significant importance for care in preventing injuries, but we do not have many information about its effects in patients after ACL reconstruction. Thus, this study is to analyze the effects of fatigue on neuromuscular behavior of quadriceps after ACL reconstruction. To reach this objective, participants were forty men, twenty healthy (26,90 ± 6,29 years) and twenty after ACL reconstruction (29,75 ± 7,01 years) with a graft of semitendinosus and gracilis tendons, between four to six months after surgery. At first, there was an assessment of joint position sense (JPS) at the isokinetic dynamometer at a speed of 5°/s and target angle of 45° to analyze the absolute error of JPS. Next, we applied the a muscle fatigue protocol, running 100 repetitions of isokinetic knee flexion-extension at 90°/s. Concurrently with this protocol, there was the assessment of muscle performance, as the peak torque (PT) and fatigue index, and electromyographic activity (RMS and median frequency). Finally, we repeated the assessment of JPS. The statistical analysis showed that patients after ACL reconstruction have, even under normal conditions, the amended JPS compared with healthy subjects and that after fatigue, both have disturbances in the JPS, but this alteration is significantly exacerbated in patients after ACL reconstruction. About muscle performance, we could notice that these patients have a lower PT, although there are no differences between the dynamometric and EMG fatigue index. These findings show the necessity about the cares of pacients with ACL reconstruction in respect of the risks of articulate instability and overload in ligamentar graft

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare the effects of the treadmill training with partial body-weight support (TPBWS) and Proprioceptive Neuromuscular Facilitation (PNF) method on gait of subjects with chronic stroke. Design: Quasi-experimental study. Setting: Laboratorial research. Participants: Twenty-three subjects (13 men and 10 women), with a mean age of 56,7 ± 8,0 years and a mean time since the onset of the stroke of 27,7 ± 20,3 months, and able to walk with personal assistance or assistive devices. Interventions: Two experimental groups underwent gait training based on PNF method (PNF group, n=11) or using the TPBWS - Gait Trainer System 2, Biodex, USA (TPBWS group, n=12), for three weekly sessions, during four weeks. Measures: Evaluation of motor function - using the Stroke Rehabilitation Assessment of Movement (STREAM) and the motor subscale of the Functional Independence Measure (motor FIM) -, and kinematic gait analyze with the Qualisys System (Qualisys Medical AB, Gothenburg, Sweden) were carried out before and after the interventions. Results: Increases in the STREAM scores (F=49.189, P<0.001) and in motor FIM scores (F=7.093, P=0.016), as well as improvement in symmetry ratio (F=7.729, P=0.012) were observed for both groups. Speed, stride length and double-support time showed no change after training. Differences between groups were observed only for the maximum ankle dorsiflexion over the swing phase (F=6.046, P=0.024), which showed an increase for the PNF group. Other angular parameters remain unchanged. Conclusion: Improvement in motor function and in gait symmetry was observed for both groups, suggesting similarity of interventions. The cost-effectiveness of each treatment should be considered for your choice

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective:To analyze the immediate effects of the Kinesio Taping® application on the quadriceps neuromuscular performance, postural balance and lower limb function in healthy subjects. Materials andmethods:This is a randomized, controlled, blinded clinical trial. Sixtyfemale volunteers(age: 23.3±2.5 years old, BMI: 22.2±2.1kg/m2)wererandomly assigned intothreegroups with20memberseach,and performedone of these threeprotocols: control -10 minutesof rest,experimental 1- patch application ontherectusfemoris (RF), vastuslateralis(VL) and vastusmedialis(VM) and experimental 2-KT application on the same muscles. Allunderwent an evaluationfor singleand triple hop distance, postural balance (baropodometry), joint position sense(JPS), peak torque (concentric and eccentricevaluation at 60°/s)and electromyographic activityof VL,before andafter intervention.Results: There wasasignificant increasein the jump distanceof thethreestudied groups,with no differencebetween groups.There were nosignificant changesin postural balance,JPS, concentricpeak torqueand RMSof the VLin none of the groups. There was a reduction ineccentricpeak torquein all groups, without differencesbetween groups.Conclusion:The KT application on the RF, VL and VMmusclesis not able tosignificantly improvelower limbfunction and postural balance, as well as the kneeextensor peaktorque, JPSand the VL muscleactivation amplitudeof healthy women.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the effect of different resting periods, after induced muscle fatigue, in the quadriceps femoris neuromuscular performance, in healthy subjects. Methods: Sixty-four volunteers, of both genders, with an average of 21,8 ± 1,7 years and mean body mass index of 24,2 ± 3,7 Kg/m2 were randomly assigned into 4 groups: control group (was not induced fatigue); Experimental Group 1 (Exp. 1 1 minute of rest after fatigue); Experimental Group 3 (Exp. 3 3 minutes of rest after fatigue) and Experimental Group 5 (Exp. 5 5 minutes of rest after fatigue). The subjects were evaluated to the knee´s joint position sense (JPS), followed by 5 flexion-extension knee concentric isokinetic contractions at 60°/s, with concomitant recording of median frequency (Fmed) of rectus femoris (RF), vastus lateralis (VL) and vastus medialis (VM). Then they underwent a muscle fatigue protocol (30 flexion-extension knee concentric contractions at 60°/s) and were reevaluated on the isokinetic performance, Fmed and JPS. Blood lactate levels were measured before initial assessment, immediately after the fatigue protocol and 5 minutes after the end of the rest period. Results: The adoption of 3 minutes of rest was sufficient to restore the initial conditions for the peak torque normalized by body weight and the VL and VM Fmed. The joint position sense returned to its initial values with 1 minute rest. The lactate concentration remained high regardless of the adopted rest period. Conclusion: The use of 3-minute rest period is sufficient for the reestablishment of the neuromuscular parameters to the pre fatigue values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate the immediate effects of laser therapy on neuromuscular performance in healthy subjects after a muscle fatigue. This is a clinical trial, controlled, randomized, blinded, attended by 80 volunteers of both genders, healthy, with ages between 18 to 28 years. Initially the volunteers performed an initial evaluation (EV1) using electromyography in the biceps muscle, associated with assessment in isokinetic dynamometry with 5 concentric contractions (60 °/s) for elbow flexion. The subjects were randomly allocated into 4 groups: G1 (control, n = 20), G2 (placebo, n = 20), G3 (pre-fatigue laser, n = 20), and G4 (post fatigue laser, n = 20). The muscular fatigue protocol had 30 concentric isokinetic contractions (120 °/s). We used a 808 nm laser, power of 100 mW, applied at the belly of the biceps muscle. After the speeches the volunteers performed a final evaluation (EV2). Test was applied to two-way ANOVA with post hoc Turkey, with a significance level of 5%. There was no significant difference in electromyographic evaluation. In dynamometric evaluation showed a drop in peak torque, peak torque normalized to body weight (p <0.001) and average power (p <0, 05) between the initial and final evaluations in control. Among the groups there was a significant difference between the control and the other groups in relation to peak torque (p <0.05), peak torque to body weight (p <0.001) and average power (p <0.05). Therefore, the low intensity laser therapy does not alter the immediate neuromuscular performance after fatigue

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivo: Investigar os efeitos imediatos do Kinesio Taping® no desempenho neuromuscular do Quadríceps Femoral (QF) de indivíduos submetidos à reconstrução do Ligamento Cruzado Anterior (LCA). Metodologia: trata-se de um ensaio clínico e randomizado composto por 45 indivíduos do sexo masculino que se encontravam entre 12ª e 17ª semanas após reconstrução do LCA. Todos foram submetidos a uma avaliação inicial composta pela análise do equilíbrio postural, através da baropodometria; determinação do Senso de Posição Articular (SPA), seguidas das avaliações isocinéticas excêntricas e concêntricas a 600/s, concomitante com a captação do sinal eletromiográfico do músculo Vasto Lateral (VL). Posteriormente foram alocados de forma aleatória em Grupo Controle (GC), Grupo Placebo (GP) e Grupo Experimental (GE). Os indivíduos do GE foram submetidos ao protocolo sugerido (aplicação do Kinesio Taping® no QF do membro acometido), enquanto os do GP utilizaram a aplicação do Kinesio Taping® sem as recomendações propostas pelo método. Já os indivíduos do GC permaneceram em repouso por dez minutos, sendo todos os indivíduos submetidos a uma reavaliação de forma idêntica à primeira. Foram analisadas as seguintes variáveis: pico de torque médio, pico de torque/peso corporal, potência muscular e erro absoluto do SPA para a dinamometria; amplitude ântero-posterior e médio-lateral para a baropodometria; e a amplitude de ativação muscular (Root Means Square - RMS) por meio da eletromiografia de superfície. Resultados: Nenhuma das variáveis analisadas apresentou diferenças intergrupo ou intragrupo. Conclusão: O Kinesio Taping® não altera o desempenho neuromuscular do quadríceps femoral de indivíduos submetidos à reconstrução do LCA para nenhuma das variáveis analisadas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Kinesio Taping (KT) has been used in healthy people to improve neuromuscular performance, however, few studies have evaluated its chronic effects, despite being suggested. Objective: To analyze the chronic effects of KT on neuromuscular performance of the quadriceps, the oscillation of the center of pressure and lower limb function in healthy women. Methods: blinded, randomized, controlled trial, composed of 60 women (mean age 21.9 ± 3.3 years and BMI 22.3 ± 2.2 kg / m2) submitted to the evaluation of oscillation of the center of pressure through the baropodometry, the lower limb function by the hop test, isokinetic knee performance, the electromyographic activity of the vastus lateralis (VL) and joint position sense of the knee (JPS). Then, participants were randomly divided into three groups of twenty: control - did not apply the KT; placebo - application of KT without tension on the quadriceps; Kinesio Taping - application of KT with tension in the same muscle group. The evaluations were conducted in five moments: prior to application of KT, immediately after the application, 24h, 48h after application and 24 hours after its removal (72h). SPSS 20.0 was used for statistical analysis. The KS test was used to verify the data normality, the Levene test for homogeneity of variances and a mixed-model ANOVA 3x5 to check intra and inter-group differences. Results: there was no difference in peak torque, the power, nor the electromyographic activity or SPA (p> 0.05) between groups. The displacement speed of center of pressure reduced immediately after the application on kinesio taping group (p <0.001), but with no differences between the groups (p = 0.28). There was a reduction in the time of peak torque among the three groups in the evaluations after KT application (p <0.001) and an increase in single hop in all groups (p <0.001), but with no differences between them. Conclusion: KT can not change, in a chronic way, the lower limb function, the oscillation of the center of pressure, the isokinetic performance, the JPS of the knee and the electromyographic activity of VL muscle in healthy women.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: to investigate the immediate effect of the vibrating platform on the neuromuscular performance of the quadriceps femoris and on the postural oscillation of subjects submitted to Anterior Cruciate Ligament (ACL) reconstruction. Materials and methods: this study is a randomized and blind clinical trial. Forty-four male volunteers (average age of 27,4 ±6,2 IMC of 26,85± 3,8 Kg/m² and post surgery timeframe of 17± 1,4 weeks) were randomized into two groups: OFF platform (n=22, protocol of exercise over the vibrating platform off) and ON platform (n=22 protocol of exercise over the vibrating platform on, 50Hz frequency and 4mm of amplitude). All volunteers were submitted to assessment the isokinetic evaluation of the quadriceps femoris (isometric and isokinetic at 60°/s) and of the electromyography activity of the muscles Vasto Lateralis (VL) and Vasto Medialis (VM), besides the postural oscillation (baropodometry) in two distinct moments: before and immediately after the intervention protocol. The data was analyzed through the SPSS 20.0 software, with a 5% significance level. To verify the homogeneity of the groups it was used an ANOVA one way, and a ANOVA mixed model to compare the intra and inter groups. Results: it was observed differences between the pre and the post, to latero lateral velocity, isometric torque peak and total work in comparison with intragroup. However, it wasn’t verified any difference in comparing the intergroup in the preevaluation and in the post-evaluation protocol over the vibrating platform. Conclusion: the use of the vibrating platform doesn’t change as an immediate manner the isokinetic performance of the quadriceps femoris, the electromyography activity of the VL and the VM, also doesn’t interfere with the postural oscillation of individuals that were submitted to the ACL reconstruction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ideally the smile should expose minimal gingival, therefore patients with gummy smile and passive eruption altered or excessive marginal gingivae, usually excessive gingival display because incomplete anatomical crown exposure is present. If the maxillary incisor show at rest is optimal, active upper incisor intrusion should not be iniciated. To achieve a smile with minimal gingival exposure, the anatomic crown should be fully exposed by surgical crown lengthening. Precise determination of the location of cementoenamel junction prior to surgery, precise placement of incisions and correct establish of biological width are necessary in order to achive this goal. One protocol is decribed and clinical results from 15 brazilian subjects, after three years post surgery are showed

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work is presented a new method for the determination of the orbital period (Porb) of eclipsing binary systems based on the wavelet technique. This method is applied on 18 eclipsing binary systems detected by the CoRoT (Convection Rotation and planetary transits) satellite. The periods obtained by wavelet were compared with those obtained by the conventional methods: box Fitting (EEBLS) for detached and semi-detached eclipsing binaries; and polynomial methods (ANOVA) for contact binary systems. Comparing the phase diagrams obtained by the different techniques the wavelet method determine better Porb compared with EEBLS. In the case of contact binary systems the wavelet method shows most of the times better results than the ANOVA method but when the number of data per orbital cicle is small ANOVA gives more accurate results. Thus, the wavelet technique seems to be a great tool for the analysis of data with the quality and precision given by CoRoT and the incoming photometric missions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Oil prospecting is one of most complex and important features of oil industry Direct prospecting methods like drilling well logs are very expensive, in consequence indirect methods are preferred. Among the indirect prospecting techniques the seismic imaging is a relevant method. Seismic method is based on artificial seismic waves that are generated, go through the geologic medium suffering diffraction and reflexion and return to the surface where they are recorded and analyzed to construct seismograms. However, the seismogram contains not only actual geologic information, but also noise, and one of the main components of the noise is the ground roll. Noise attenuation is essential for a good geologic interpretation of the seismogram. It is common to study seismograms by using time-frequency transformations that map the seismic signal into a frequency space where it is easier to remove or attenuate noise. After that, data is reconstructed in the original space in such a way that geologic structures are shown in more detail. In addition, the curvelet transform is a new and effective spectral transformation that have been used in the analysis of complex data. In this work, we employ the curvelet transform to represent geologic data using basis functions that are directional in space. This particular basis can represent more effectively two dimensional objects with contours and lines. The curvelet analysis maps real space into frequencies scales and angular sectors in such way that we can distinguish in detail the sub-spaces where is the noise and remove the coefficients corresponding to the undesired data. In this work we develop and apply the denoising analysis to remove the ground roll of seismograms. We apply this technique to a artificial seismogram and to a real one. In both cases we obtain a good noise attenuation

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The myotonic dystrophy (MD) is a multisystem neuromuscular disease that can affect the respiratory muscles and heart function, and cause impairment in quality of life. Objectives: Investigate the changes in respiratory muscle strength, health-related quality of life (HRQoL) and autonomic modulation heart rate (HR) in patients with MD. Methods: Twenty-three patients performed assessment of pulmonary function, sniff nasal inspiratory pressure (SNIP), the maximal inspiratory (MIP) and expiratory (MEP) pressure, and of HRQoL (SF-36 questionnaire). Of these patients, 17 underwent assessment of heart rate variability (HRV) at rest, in the supine and seated positions. Results: The values of respiratory muscle strength were 64, 70 and 80% of predicted for MEP, MIP, and SNIP, respectively. Significant differences were found in the SF-36 domains of physical functioning (58.7 ± 31,4 vs. 84.5 ± 23, p<0.01) and physical problems (43.4 ± 35.2 vs. 81.2 ± 34, p<0.001) when patients were compared with the reference values. Single linear regression analysis demonstrated that MIP explains 29% of the variance in physical functioning, 18% of physical problems and 20% of vitality. The HRV showed that from supine position to seated, HF decreased (0.43 x 0.30), and LF (0.57 x 0.70) and the LF/HF ratio (1.28 x 2.22) increased (p< 0.05). Compared to healthy persons, LF was lower in both male patients (2.68 x 2.99) and women (2.31 x 2.79) (p< 0.05). LF / HF ratio and LF were higher in men (5.52 x 1.5 and 0.8 x 0.6, p <0.05) and AF in women (0.43 x 0.21) (p< 0.05). There was positive correlation between the time of diagnosis and LF / HF ratio (r = 0.7, p <0.01). Conclusions: The expiratory muscle strength was reduced. The HRQoL was more impaired on the physical aspects and partly influenced by changes in inspiratory muscle strength. The HRV showed that may be sympathetic dysfunction in autonomic modulation of HR, although with normal adjustment of autonomic modulation during the change of posture. The parasympathetic modulation is higher in female patients and sympathetic tends to increase in patients with longer diagnosis