7 resultados para Analyte
em Universidade Federal do Rio Grande do Norte(UFRN)
Resumo:
This project describes a methodology optimization that would allow for a more efficient microwave assisted digestion process for petroleum samples. With the possible chance to vary various factors at once to see if any one factor was significant enough in the answers, experimental planning was used. Microwave assisted digestion allows, through the application of potency, an increasing number of collisions between the HNO3 and H2O2 molecules, favoring sample opening for complex matrixes. For this, a 24 factorial experimental planning was used, varying potency, time and the volumes for HNO3 65% and H2O2 30%. To achieve the desired answers, several elements were monitored (C, Cu, Cr, Fe, Ni, Zn and V) through Inductively coupled plasma atomic emission spectroscopy (ICP-OES). With this initial study it was noticed that the HNO3 was not a significant factor for any of the statistical studies for any of the analytes and the other 3 factors and their interactions showed statistical significance. A Box Behnken experimental planning was used taking in consideration 3 factors: H2O2 volume, time (min) and Potency (W), Nitric Acid kept at 4mL for a mass of 0,1g of petroleum. The results were extremely satisfying showing higher efficiency in the digestion process and taking in a responsibility between the answers for each analyte and the carbon monitoring was achieved in the following conditions: 7mL of H2O2, 700 Watts of potency and a reaction time of 7 minutes with 4mL de HNO3 for a mass of 0,1g of petroleum. The optimized digestion process was applied to four different petroleum samples and the analytes determined by ICP-OES
Resumo:
The ethanol is the most overused psychoactive drug over the world; this fact makes it one of the main substances required in toxicological exams nowadays. The development of an analytical method, adaptation or implementation of a method known, involves a process of validation that estimates its efficiency in the laboratory routine and credibility of the method. The stability is defined as the ability of the sample of material to keep the initial value of a quantitative measure for a defined period within specific limits when stored under defined conditions. This study aimed to evaluate the method of Gas chromatography and study the stability of ethanol in blood samples, considering the variables time and temperature of storage, and the presence of preservative and, with that check if the conditions of conservation and storage used in this study maintain the quality of the sample and preserve the originally amount of analyte present. Blood samples were collected from 10 volunteers to evaluate the method and to study the stability of ethanol. For the evaluation of the method, part of the samples was added to known concentrations of ethanol. In the study of stability, the other side of the pool of blood was placed in two containers: one containing the preservative sodium fluoride 1% and the anticoagulant heparin and the other only heparin, was added ethanol at a concentration of 0.6 g/L, fractionated in two bottles, one being stored at 4ºC (refrigerator) and another at -20ºC (freezer), the tests were performed on the same day (time zero) and after 1, 3, 7, 14, 30 and 60 days of storage. The assessment found the difference in results during storage in relation to time zero. It used the technique of headspace associated with gas chromatography with the FID and capillary column with stationary phase of polyethylene. The best analysis of chromatographic conditions were: temperature of 50ºC (column), 150ºC (jet) and 250ºC (detector), with retention time for ethanol from 9.107 ± 0.026 and the tercbutanol (internal standard) of 8.170 ± 0.081 minutes, the ethanol being separated properly from acetaldehyde, acetone, methanol and 2-propanol, which are potential interfering in the determination of ethanol. The technique showed linearity in the concentration range of 0.01 and 3.2 g/L (0.8051 x + y = 0.6196; r2 = 0.999). The calibration curve showed the following equation of the line: y = x 0.7542 + 0.6545, with a linear correlation coefficient equal to 0.996. The average recovery was 100.2%, the coefficients of variation of accuracy and inter intra test showed values of up to 7.3%, the limit of detection and quantification was 0.01 g/L and showed coefficient of variation within the allowed. The analytical method evaluated in this study proved to be fast, efficient and practical, given the objective of this work satisfactorily. The study of stability has less than 20% difference in the response obtained under the conditions of storage and stipulated period, compared with the response obtained at time zero and at the significance level of 5%, no statistical difference in the concentration of ethanol was observed between analysis. The results reinforce the reliability of the method of gas chromatography and blood samples in search of ethanol, either in the toxicological, forensic, social or clinic
Resumo:
Tuberculosis is a serious disease, but curable in practically 100% of new cases, since complied the principles of modern chemotherapy. Isoniazid (ISN), Rifampicin (RIF), Pyrazinamide (PYR) and Chloride Ethambutol (ETA) are considered first line drugs in the treatment of tuberculosis, by combining the highest level of efficiency with acceptable degree of toxicity. Concerning USP 33 - NF28 (2010) the chromatography analysis to 3 of 4 drugs (ISN, PYR and RIF) last in average 15 minutes and 10 minutes more to obtain the 4th drug (ETA) using a column and mobile phase mixture different, becoming its industrial application unfavorable. Thus, many studies have being carried out to minimize this problem. An alternative would use the UFLC, which is based with the same principles of HPLC, however it uses stationary phases with particles smaller than 2 μm. Therefore, this study goals to develop and validate new analytical methods to determine simultaneously the drugs by HPLC/DAD and UFLC/DAD. For this, a analytical screening was carried out, which verified that is necessary a gradient of mobile phase system A (acetate buffer:methanol 94:6 v/v) and B (acetate buffer:acetonitrile 55:45 v/v). Furthermore, to the development and optimization of the method in HPLC and UFLC, with achievement of the values of system suitability into the criteria limits required for both techniques, the validations have began. Standard solutions and tablets test solutions were prepared and injected into HPLC and UFLC, containing 0.008 mg/mL ISN, 0.043 mg/mL PYR, 0.030 mg.mL-1 ETA and 0.016 mg/mL RIF. The validation of analytical methods for HPLC and UFLC was carried out with the determination of specificity/selectivity, analytical curve, linearity, precision, limits of detection and quantification, accuracy and robustness. The methods were adequate for determination of 4 drugs separately without interfered with the others. Precise, due to the fact of the methods demonstrated since with the days variation, besides the repeatability, the values were into the level required by the regular agency. Linear (R> 0,99), once the methods were capable to demonstrate results directly proportional to the concentration of the analyte sample, within of specified range. Accurate, once the methods were capable to present values of variation coefficient and recovery percentage into the required limits (98 to 102%). The methods showed LOD and LOQ very low showing the high sensitivity of the methods for the four drugs. The robustness of the methods were evaluate, facing the temperature and flow changes, where they showed robustness just with the preview conditions established of temperature and flow, abrupt changes may influence with the results of methods
Resumo:
In this work, chitosan was used as a coating of pure perlite in order to increase the accessibility of the groups OH- e NH2+the adsorptionof ions Mn2+ e Zn2+.The characterization results of the expanded perlite classified as microporous and whose surface area 3,176 m2 g-1after the change resulted in 4,664 m2g-1.From the thermogravimetry(TG) it was found that the percentage of coating was34,3%.The infrared analysis can prove the presence of groups Si-OH, Si-O e Al-O-Siresulting from the perlite and C=O, NH2and OH characterization of chitosan. The experiments on experiments on the adsorption of Mn and Zn were performed in the concentration range of10 a 50 mgL-1and the adsorption capacity inpH 5,8 e 5,2 was 19,49 and 23,09 mgg-1to 25 oC,respectively.The adsorption data were best fitted to Langmuir adsorption model to Langmuir adsorption model for both metalionsisindicative of monolayer adsorption. The kinetics of adsorption were calculated from the equation of Lagergren fitting the model pseudo-second-order for all initial concentrations, suggesting that adsorption of ions Mn2+ and Zn2+ follows the kinetics of pseudo-second-order and whose constant Speedk2(g/mg.min) are 0,105 e 3,98 and capacity and maximum removal qe 4,326 e 3,348,respectively.In this study we used a square wave voltammetry cathodic stripping voltammetry to quantify the adsorbed ions, and the working electrode glassy carbon, reference electrode silver / silver chloride and a platinum auxiliary electrode. The attainment of the peaks corresponding to ions Mn2+ and Zn2+ was evaluated in and electrochemical cell with a capacity of 30 mL using a buffer system (Na2HPO4/NaH2PO4)at pH 4 and was adjusted with solutionsH3PO4 0,1molL-1and NaOH 0,1 molL-1and addition of the analyte has been a cathodic peak in- 0,873 Vand detection limit of2,55x10-6molL-1para Zn.The dough used for obtaining the adsorption isotherm was 150 mg and reached in 120 min time of equilibrium for both metal ions.The maximum adsorption for 120 min with Mn concentration 20 mgL-1 and Zn 10 mgL-1,was91, 09 e 94, 34%, respectively
Resumo:
This work aims to detect polycyclic aromatic hydrocarbons (PAHs) through optimized analytical techniques, such as gas chromatography with flame-ionisation detector (CGFID), gas chromatography coupled to mass spectrometry (CGMS), Fluorescence Spectroscopy of Molecular and Purpot of oils and greases (POG). Apply to chemometrics, Factorial Planning 23, in the preparation of samples by liquid-liquid extraction. The sample preparation was used for liquid-liquid extraction and factors in this sample was used for the application of factorial planning 23, such as the use of ultrasound, solvents (dichloromethane, hexane and chloroform) and ratio of solvent / synthetic sample. These factors were assigned two types of levels: positive and negative. It was used to form the cube to better analyze the answers. The responses of the eight combinations were obtained in reading the spectrofluorimetric. The optimization of equipment were used, and they served in the HPA's identification of the samples collected in Rio Potengi. The optimization of the equipment was observed every 16's and PAH in the samples was found that the HPA's came from contamination of the Rio Potengi. The contamination comes through organic household waste, hospital waste, and among other contamination that comes from industries that are installed around the River The factorial design of high validity, it was observed a more effective sample preparation. The factorial design of liquid-liquid extraction showed a way to spend less solvent in less time using an ideal solvent, but also a way to extract more analyte from the matrix itself is water. In planning a smaller form factor extraction was the use of ultrasound, the ratio 1:3 corresponding to a solvent and sample 3 and the best solvent was dichloromethane who presented a viable extraction, not discarding the possibility of using also the hexane. The chloroform and may be toxic not had a good extraction
Resumo:
Soil contamination by pesticides is an environmental problem that needs to be monitored and avoided. However, the lack of fast, accurate and low cost analytical methods for discovering residual pesticide in complex matrices, such as soil, is a problem still unresolved. This problem needs to be solved before we are able to assess the quality of environmental samples. The intensive use of pesticides has increased since the 60s, because the dependence of their use, causing biological imbalances and promoting resistance and recurrence of high populations of pests and pathogens (upwelling). This has contributed to the appearance of new pests that were previously under natural control. To develop analytical methods that are able to quantify residues pesticide in complex environment. It is still a challenge for many laboratories. The integration of two analytical methods one ecotoxicological and another chemical demonstrates the potential for environmental analysis of methamidophos. The aim of this study was to evaluate an ecotoxicological method as "screening" analytical methamidophos in the soil and perform analytical confirmation in the samples of the concentration of the analyte by chemical method LC-MS/MS In this work we tested two soils: a clayey and sandy, both in contact with the kinetic methamidophos model followed pseudo-second order. The clay soil showed higher absorption of methamidophos and followed the Freundlich model, while the sandy, the Langmuir model. The chemical method was validated LC-MS/MS satisfactory, showing all parameters of linearity, range, precision, accuracy, and sensitivity adequate. In chronic ecotoxicological tests with C. dubia, the NOEC was 4.93 and 3.24 for ng L-1 of methamidophos to elutriate assays of sandy and clay soils, respectively. The method for ecotoxicological levels was more sensitive than LC-MS/MS detection of methamidophos, loamy and sandy soils. However, decreasing the concentration of the standard for analytical methamidophos and adjusting for the validation conditions chemical acquires a limit of quantification (LOQ) in ng L-1, consistent with the provisions of ecotoxicological test. The methods described should be used as an analytical tool for methamidophos in soil, and the ecotoxicological analysis can be used as a "screening" and LC-MS/MS as confirmatory analysis of the analyte molecule, confirming the objectives of this work
Resumo:
This project describes a methodology optimization that would allow for a more efficient microwave assisted digestion process for petroleum samples. With the possible chance to vary various factors at once to see if any one factor was significant enough in the answers, experimental planning was used. Microwave assisted digestion allows, through the application of potency, an increasing number of collisions between the HNO3 and H2O2 molecules, favoring sample opening for complex matrixes. For this, a 24 factorial experimental planning was used, varying potency, time and the volumes for HNO3 65% and H2O2 30%. To achieve the desired answers, several elements were monitored (C, Cu, Cr, Fe, Ni, Zn and V) through Inductively coupled plasma atomic emission spectroscopy (ICP-OES). With this initial study it was noticed that the HNO3 was not a significant factor for any of the statistical studies for any of the analytes and the other 3 factors and their interactions showed statistical significance. A Box Behnken experimental planning was used taking in consideration 3 factors: H2O2 volume, time (min) and Potency (W), Nitric Acid kept at 4mL for a mass of 0,1g of petroleum. The results were extremely satisfying showing higher efficiency in the digestion process and taking in a responsibility between the answers for each analyte and the carbon monitoring was achieved in the following conditions: 7mL of H2O2, 700 Watts of potency and a reaction time of 7 minutes with 4mL de HNO3 for a mass of 0,1g of petroleum. The optimized digestion process was applied to four different petroleum samples and the analytes determined by ICP-OES