Resumo:
This project describes a methodology optimization that would allow for a more efficient microwave assisted digestion process for petroleum samples. With the possible chance to vary various factors at once to see if any one factor was significant enough in the answers, experimental planning was used. Microwave assisted digestion allows, through the application of potency, an increasing number of collisions between the HNO3 and H2O2 molecules, favoring sample opening for complex matrixes. For this, a 24 factorial experimental planning was used, varying potency, time and the volumes for HNO3 65% and H2O2 30%. To achieve the desired answers, several elements were monitored (C, Cu, Cr, Fe, Ni, Zn and V) through Inductively coupled plasma atomic emission spectroscopy (ICP-OES). With this initial study it was noticed that the HNO3 was not a significant factor for any of the statistical studies for any of the analytes and the other 3 factors and their interactions showed statistical significance. A Box Behnken experimental planning was used taking in consideration 3 factors: H2O2 volume, time (min) and Potency (W), Nitric Acid kept at 4mL for a mass of 0,1g of petroleum. The results were extremely satisfying showing higher efficiency in the digestion process and taking in a responsibility between the answers for each analyte and the carbon monitoring was achieved in the following conditions: 7mL of H2O2, 700 Watts of potency and a reaction time of 7 minutes with 4mL de HNO3 for a mass of 0,1g of petroleum. The optimized digestion process was applied to four different petroleum samples and the analytes determined by ICP-OES
Resumo:
The accelerated growth of urban regions have produced relevant effects on water resources. Urban regions need an adequate institutional structure that can be able to face environmental demands and the adverse effects of land use on water resources. This study aims at analysing land use effects on heavy metals concentration in sediments and water, as well as making a comparative analysis involving water physical-chemical parameters. Applied methodology included both in loco water parameters measurement and water and bed sediment sampling at 8 sections along the fluvial system. Sample analysis was performed in laboratory in order to measure heavy metal concentrations. It was measured metal concentrations of Al, Cu, Pb, Cd, Fe, Ni and Zn. Once the samples were subjected to acid digestion (method 3050B), concentration values were measured by using atomic absorption spectrometry by flame (ICP-FLAA). The analysis results were compared with normative reference, these standards is intended to assess the risks of toxic substances in sediment and water management programs. The normative reference used in this work were: a) Ontario Ministry of the Environment and Energy (OMEE, 1993) b) Normative Netherlands (VROM, 2000); c) Normative Canadian (CCME, 1999); d) United States Environmental Protection Agency (USEPA, 1977), e) CONAMA Resolution No. 344/2004; f) CONAMA Resolution No. 357/2005. The high concentrations of iron (38,750 mg.g-1), Lead (1100 mg.g-1), Nickel (100 μg.g-1) and zinc (180 μg.g-1) detected sediments confirm the state of degradation of the aquatic system. Iron concentrations (1.08 mg.L-1), Aluminum (0.6 mg.L-1) and phosphorus (0.05 mg.L-1) present in the water are outside the established standards for human consumption
Resumo:
The aim of this study was to quantify the presence of major and minor elements in the sediments of the Jundiaí-Potengi estuary, bordering the municipalities of Macaíba, Natal and São Gonçalo do Amarante in the state of Rio Grande do Norte, Brazil, considering the evidence of anthropic activity along this estuary, resulting in pollution by treated and untreated wastewaters as well as those produced by industry and shrimp farming. The assessment of the environmental status of this estuary was based on physical-chemical parameters, such as granulometry, organic matter and the major (Al, Fe, Mn and P) and minor (Cd, Cr, Cu, Ni, Pb and Zn) elements found in sediment samples. Two collections were made at 12 georeferenced points along the channel of the estuary at different times. Granulometric analysis was carried out and the percentage of organic matter was determined. The sediments were microwave digested using acid digestion and quantitative analyses of the elements Al, Fe, Cd, Cr, Cu, Mn, Ni, P, Pb and Zn were performed by inductively coupled plasma optical emission spectrometry. Sediment analysis followed the methodology proposed by US EPA 3051A for total elements analysis. The small correlation between the organic matter and the elements studied here suggests that they are of geochemical rather than anthropic origin. The analytical results obtained from the bottom sediment samples in the study area show that the concentration of elements was below the reference values for standard shales (Turekian & Wedepohl, 1961) at the vast majority of points analyzed, ruling out a possible contamination by metals
Resumo:
Leather tanneries generate effluents with high content of heavy metals, especially chromium, which is used in the mineral tanning process. Microemulsions have been studied in the extraction of heavy metals from aqueous solutions. Considering the problems related with the sediment resulting from the tanning process, due to its high content in chromium, in this work this sediment was characterized and microemulsion systems were applied for chromium removal. The extraction process consists in the removal of heavy metal ions present in an aqueous feeding solution (acid digestion solution) by a microemulsion system. First three different solid sludge digestion methods were evaluated, being chosen the method with higher digestion capacity. For this digestion method, seeking its optimization, was evaluated the influence of granule size, temperature and digestion time. Experimental results showed that the method proposed by USEPA (Method A) was the most efficient one, being obtained 95.77% of sample digestion. Regarding to the evaluated parameters, the best results were achieved at 95°C, 14 Mesh granule size, and 60 minutes digestion time. For chromium removal, three microemulsion extraction methods were evaluated: Method 1, in a Winsor II region, using as aqueous phase the acid digestion solution; Method 2, in a Winsor IV region, being obtained by the addition of the acid digestion solution to a microemulsion phase, whose aqueous phase is distilled water, until the formation of Winsor II system; and Method 3, in a Winsor III region, consisting in the formation of a Winsor III region using as aqueous phase the acid digestion solution, diluted in NaOH 0.01N. Seeking to optimize the extraction process only Method 1 (Systems I, II, and VIII) and Method 2 (System IX) were evaluated, being chosen points inside the interest regions (studied domains) to study the influence of contact time and pH in the extraction percentiles. The studied systems present the following compositions: System I: Surfactant Saponified coconut oil, Cosurfactant 1-Butanol, Oil phase Kerosene, Aqueous phase 2% NaCl solution; System II: Aqueous phase Acid digestion solution with pH adjusted using KOH (pH 3.5); System VIII: Aqueous phase - Acid digestion solution (pH 0.06); and System IX Aqueous phase Distilled water (pH 10.24), the other phases of Systems II, VIII and IX are similar to System I. Method 2 showed to be the more efficient one regarding chromium extraction percentile (up to 96.59% - pH 3.5). Considering that with Method 2 the microemulsion region only appears in the Winsor II region, it was studied Method 3 (System X) for the evaluation and characterization of a triphasic system, seeking to compare with a biphases system. System X is composed by: Surfactant Saponified coconut oil, Cosurfactant 1-Butanol, Oil phase Kerosene, Aqueous phase Acid digestion solution diluted with water and with its pH adjusted using 0.01N NaOH solution. The biphasic and triphasic microemulsion systems were analyzed regarding its viscosity, extraction efficiency and drop effective diameter. The experimental results showed that for viscosity studies the obtained values were low for all studied systems, the diameter of the drop is smaller in the Winsor II region, with 15.5 nm, reaching 46.0 nm in Winsor III region, being this difference attributed to variations in system compositions and micelle geometry. In chromium extraction, these points showed similar results, being achieved 99.76% for Winsor II system and 99.62% for Winsor III system. Winsor III system showed to be more efficient due to the obtaining of a icroemulsion with smaller volume, with the possibility to recover the oil phase in excess, and the use of a smaller proportion of surfactant and cosurfactant (C/S)
Resumo:
This project describes a methodology optimization that would allow for a more efficient microwave assisted digestion process for petroleum samples. With the possible chance to vary various factors at once to see if any one factor was significant enough in the answers, experimental planning was used. Microwave assisted digestion allows, through the application of potency, an increasing number of collisions between the HNO3 and H2O2 molecules, favoring sample opening for complex matrixes. For this, a 24 factorial experimental planning was used, varying potency, time and the volumes for HNO3 65% and H2O2 30%. To achieve the desired answers, several elements were monitored (C, Cu, Cr, Fe, Ni, Zn and V) through Inductively coupled plasma atomic emission spectroscopy (ICP-OES). With this initial study it was noticed that the HNO3 was not a significant factor for any of the statistical studies for any of the analytes and the other 3 factors and their interactions showed statistical significance. A Box Behnken experimental planning was used taking in consideration 3 factors: H2O2 volume, time (min) and Potency (W), Nitric Acid kept at 4mL for a mass of 0,1g of petroleum. The results were extremely satisfying showing higher efficiency in the digestion process and taking in a responsibility between the answers for each analyte and the carbon monitoring was achieved in the following conditions: 7mL of H2O2, 700 Watts of potency and a reaction time of 7 minutes with 4mL de HNO3 for a mass of 0,1g of petroleum. The optimized digestion process was applied to four different petroleum samples and the analytes determined by ICP-OES