174 resultados para Programa de tratamento comportamental


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The contamination of water sources of public drinking by waste originated by anthropogenic activities has brought various risks to human health. Among the consequences of such activities can highlight the bloom of microalgae and cyanobacteria, which have the potential to produce toxins dangerous to humans, and the presence of humic substances that are generated by the decomposition of natural organic matter (NOM), such as vegetation. When found in water sources for public supply, present negative aspects conferring high color, odor and taste. The double filtration technology has good efficiency in water with the presence of cyanobacteria and different quality variations. Therefore, this study aimed to evaluate the behavior of the technique of double filtration with pre-oxidation for water purifiers the lagoon of Extremoz-RN, which currently has high concentrations of cyanobacteria. The research is summarized in four phases: the first phase turned to static tests in jarteste equipment in the laboratory and subsequent phases were tested in the Pilot Plant of Double Filtration. For the second and third stage filtration rates were tested filtration rates of 120 and 180 m3 / m2 .day for ascending boulders filters and 160 and 240 m3 / m2 .day in the filters in quick sand descendants. The last phase aimed to evaluate the double filtration with pre-oxidation. The results demonstrated that the system could produce double filtration in all trials of good quality water according to the Decree nº. 2914/11 of the Ministry of Health. The use of preoxidation favored the removal of microcystin and color at the end of the tests, reaching a percentage of color removal around 60%. The analysis of variance in the data, enabled prove that the filtration rates of 180 m3 / m2.d the gravel filter and 240 m3 /m2 .d in rapid filters, were the most significant for the removal of turbidity. The ascending filter of boulder 4 with particle size finer filter layer showed the best performance and the best means of turbidity and apparent color. The rapid filter downward 1 was more efficient in removing turbidity reaching removal about 100%

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective was to understand the process of caring for a center for cancer treatment from the perspective of nurses and patients. This is a qualitative research, xploratory and descriptive, performed in a cancer treatment center in Natal / RN / Brazil. Data collection occurred between August 2013 and February 2014, being effected by means of two techniques: photographic record and projective interviews with nurses and patients. Social actors included in the study were ten professional nursing and ten patients admitted to the surgical department of the institution. The criteria used for inclusion of professionals were: be professional in the field of nursing, being an employee of the hospital, to be inserted in the scale of nurses of the institution at the time of data collection. For the patients were included who had preserved their cognitive abilities and who were hospitalized and at any stage of treatment. We used content analysis proposed by Bardin, for the analysis of material collected during projective interview. The research followed the ethical and legal principles that govern scientific research on human beings, being conducted by the project approval by the Research Ethics Committee of the Northern League Against Cancer Riograndense with 295 673 and look CAAE 16104313.0.0000.5293. Referring to nurses, they demonstrated different views about care, which sprouted from a holistic, multidisciplinary approach and welcoming, as well as linked to the performance of procedures and compliance with the requirements technicality. Furthermore, these subjects also showed that care unfolds through the actions of management in carrying out the records in the humanization of care by meeting the needs of the patient and ambience. Front of patients, it is noteworthy that, for them, care happens through attitudes of caring and professional approach, and by performing procedures, being mentioned as a careless lack of structure of the institution and the discomfort caused by this condition factors. It was evident also that the actors involved in the care, the perception of professionals and patients, are represented by nurses, doctors, psychologists, nutritionists, as well as kitchen assistants and cleaners; beyond family companion, the individual himself as responsible for their care and volunteer caregiver. In this opportunity, it is concluded 9 that an understanding of care from the perspective of nurses and patients involves broad issues ranging from perceptions of care that embraces a dynamic complex elements and attitudes imbued with meanings, in which those involved can assume both the role of carers as care beings, even a carefully tied to prescribed routines and performing procedures. Thus, the findings described refer to reflections on the care provided to cancer patients and whether this, in fact, translates principles of a humane practice

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A história da hanseníase é marcada por preconceito, exclusão social, estigma, abandono e medo, por ter sido conhecida durante muito tempo como incurável e contagiosa. Além dos agravos inerentes às alterações dermatoneurológicas e consequentes incapacidades físicas, são ressaltadas as repercussão emocionais, alterações nos hábitos cotidianos e mudanças na configuração familiar. Atualmente a hanseníase é conhecida como doença negligenciada, com alta incidência e prevalência, considerada como um problema de saúde alvo de incentivos e mobilizações das políticas públicas. Ao estudar a história da hanseníase, parte-se do pressuposto de que pouco se sabe sobre as repercussões da doença do passado na vida dos familiares de ex-doentes tratados em regime asilar, assim como a visão e os sentimentos dos mesmos familiares diante da hanseníase na atualidade. Portanto, objetivou-se narrar a história de familiares de ex-doentes de hanseníase que foram tratados em hospital colônia. Os objetivos específicos são: Identificar se familiares de pacientes com hanseníase tratados em hospitais colônia eram atingidos pelo preconceito, estigma e exclusão que permeava a vida dos portadores da doença; Verificar se o tratamento de ex-doentes de hanseníase em hospitais colônia alterou a efetivação de laços familiares tais indivíduos e os membros de sua família; Averiguar qual a compreensão que familiares de ex-doentes de hanseníase tratados em hospitais colônia têm sobre a hanseníase; Promover, junto aos participantes da pesquisa, atividade de promoção da saúde sobre hanseníase. Adotou-se o estudo exploratório e descritivo, com abordagem qualitativa com suporte na História Oral de Temática como técnica e referencial metodológico. Os 52 familiares de ex-doentes de lepra que foram segregados no Hospital Colônia São Francisco de Assis, cadastrados no MORHAN-Potiguar, constituíram a colônia. A partir do ponto zero houve o recrutamento dos participantes que compuseram a rede, totalizando 10 colaboradores, de ambos os sexos e idade de 44 a 76 anos. Após aprovação pelo Comitê de Ética em Pesquisa - UFRN, sob o protocolo 650.654/2014 e CAAE 25922214.3.0000.5537, realizou-se a coleta de dados por meio de entrevista, utilizando instrumento de identificação da rede e questões abertas. As entrevistas foram gravadas, transcritas, conferidas pelos colaboradores e posteriormente transcriadas. Tratou-se as histórias, narradas pela técnica de Análise Temática de Conteúdo, segundo Bardin, emergindo três eixos temáticos: Impacto nas relações sociais (Estigma e preconceito; Exclusão social); Impacto nas relações familiares (Desagregação familiar; Restrições para visita; Compartilhamento e construção de uma nova família; Consequências familiar geradas pelo isolamento; Reconstrução do vínculo familiar); e Pensamentos frente a lepra e a hanseníase (A história no passado; A história no presente). O fato de ter um familiar doente de hanseníase segregado em hospital colônia gerou empecilhos nas relações sociais vivenciadas pelos colaboradores do estudo, que embora não tivessem a doença, foram vitimados pela exclusão social, estigma e preconceito. O internamento compulsório também gerou modificações na estrutura familiar, com distanciamento, alteração no vínculo e tentativa de reestruturação familiar. Os colaboradores também refletiram sobre política de controle da lepra no passado, assim como a adotada no presente frente à hanseníase.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A major and growing problems faced by modern society is the high production of waste and related effects they produce, such as environmental degradation and pollution of various ecosystems, with direct effects on quality of life. The thermal treatment technologies have been widely used in the treatment of these wastes and thermal plasma is gaining importance in processing blanketing. This work is focused on developing an optimized system of supervision and control applied to a processing plant and petrochemical waste effluents using thermal plasma. The system is basically composed of a inductive plasma torch reactors washing system / exhaust gases and RF power used to generate plasma. The process of supervision and control of the plant is of paramount importance in the development of the ultimate goal. For this reason, various subsidies were created in the search for greater efficiency in the process, generating events, graphics / distribution and storage of data for each subsystem of the plant, process execution, control and 3D visualization of each subsystem of the plant between others. A communication platform between the virtual 3D plant architecture and a real control structure (hardware) was created. The goal is to use the concepts of mixed reality and develop strategies for different types of controls that allow manipulating 3D plant without restrictions and schedules, optimize the actual process. Studies have shown that one of the best ways to implement the control of generation inductively coupled plasma techniques is to use intelligent control, both for their efficiency in the results is low for its implementation, without requiring a specific model. The control strategy using Fuzzy Logic (Fuzzy-PI) was developed and implemented, and the results showed satisfactory condition on response time and viability

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work proposes the use of the behavioral model of the hysteresis loop of the ferroelectrics capacitor as a new alternative to the usually costly techniques in the computation of nonlinear functions in artificial neurons implemented on reconfigurable hardware platform, in this case, a FPGA device. Initially the proposal has been validated by the implementation of the boolean logic through the digital models of two artificial neurons: the Perceptron and a variation of the model Integrate and Fire Spiking Neuron, both using the model also digital of the hysteresis loop of the ferroelectric capacitor as it’s basic nonlinear unit for the calculations of the neurons outputs. Finally, it has been used the analog model of the ferroelectric capacitor with the goal of verifying it’s effectiveness and possibly the reduction of the number of necessary logic elements in the case of implementing the artificial neurons on integrated circuit. The implementations has been carried out by Simulink models and the synthesizing has been done through the DSP Builder software from Altera Corporation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The water supply and treatment is considered as a great benefit considering that, if done efficiently, provides public health. However, considering the WTP (Water Treatment Plant) is an industry, with its inputs and waste generation, they must be constantly evaluated and monitored to verify the best and most appropriate way to process and dispose their waste, minimizing therefore the potential impacts to the environment. By volume, the most significant waste is the rapid filter backwash water. It is very common the disposal of this waste without treatment in water sources, which are used, for the most part, as a water supply source of a downstream population. This study evaluated quantitative and qualitative parameters in filter backwash water in three WTP - Itaitinga, Maranguape and Pacatuba, located in Ceará State, northeast of Brazil. It was found that the Maranguape WTP, in terms of treatment capacity, is the larger. The Itaitinga WTP is the one that consumes more water during filters washing. The Pacatuba WTP exhibited higher concentration of total suspended and settleable solids, COD and aluminum in the filters backwash water. It is noteworthy that the settleable solids and total suspended solids in all three WTP are above the effluent discharge standard recommended by Resolution 154/2002 of SEMACE (State Superintendent of Environment of Ceará). It was concluded that the filter backwash water from the study WTP exceeded the allowed values for legislation to be disposed directly into surface water bodies. It is suggested as an alternative to treat and recycle the filter backwashing water the construction of sludge settling ponds.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work the degradation of real and synthetic wastewater was studied using electrochemical processes such as oxidation via hydroxyl radicals, mediated oxidation via active chlorine and electrocoagulation. The real effluent used was collected in the decanter tank of the Federal University of Rio Grande do Norte (ETE-UFRN) of Effluent Treatment Plant and the other a textile effluent dye Ácido Blue 113 (AB 113) was synthesized in the laboratory. In the electrochemical process, the effects of anode material, current density, the presence and concentration of chloride as well as the active chlorine species on site generated were evaluated. Electrodes of different compositions, Ti/Pt, Ti/Ru0,3Ti0,7O2, BDD, Pb/PbO2 and Ti/TiO2-nanotubes/PbO2 were used as anodes. These electrodes were subjected to electroanalytical analysis with the goal of checking how happen the anodic and cathodic processes across the concentrations of NaCl and supporting electrolyte used. The potential of oxygen evolution reaction were also checked. The effect of active chlorine species formed under the process efficiency was evaluated by removing the organic matter in the effluent-ETE UFRN. The wastewater treatment ETE-UFRN using Ti/Pt, DDB and Ti/Ru0,3Ti0,7O2 electrodes was evaluated, obtaining good performances. The electrochemical degradation of effluent-UFRN was able to promote the reduction of the concentration of TOC and COD in all tested anodes. However, Ti/Ru0,3Ti0,7O2 showed a considerable degradation due to active chlorine species generated on site. The results obtained from the electrochemical process in the presence of chloride were more satisfactory than those obtained in the absence. The addition of 0.021 M NaCl resulted in a faster removal of organic matter. Secondly, was prepared and characterized the electrode Ti/TiO2-nanotubes/PbO2 according to what the literature reports, however their preparation was to disk (10 cm diameter) with surface area and higher than that described by the same authors, aiming at application to textile effluent AB 113 dye. SEM images were taken to observe the growth of TiO2 nanotubes and confirm the electrodeposition of PbO2. Atomic Force Microscope was also used to confirm the formation of these nanotubes. Furthermore, was tested and found a high electrochemical stability of the electrode Ti/TiO2-nanotubes/PbO2 for applications such as long-term indicating a good electrocatalytic material. The electrochemical oxidation of AB 113 using Ti/Pt, Pb/PbO2 and Ti/TiO2-nanotubes/PbO2 and Al/Al (electrocoagulation) was also studied. However, the best color removal and COD decay were obtained when Ti/TiO2-nanotubes/PbO2 was used as the anode, removing up to 98% of color and 92,5% of COD decay. Analysis of GC/MS were performed in order to identify possible intermediates formed in the degradation of AB 113.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, the treatment of wastewater from the textile industry, containing dyes as Yellow Novacron (YN), Red Remazol BR (RRB) and Blue Novacron CD (NB), and also, the treatment of wastewater from petrochemical industry (produced water) were investigated by anodic oxidation (OA) with platinum anodes supported on titanium (Ti/Pt) and boron-doped diamond (DDB). Definitely, one of the main parameters of this kind of treatment is the type of electrocatalytic material used, since the mechanisms and products of some anodic reactions depend on it. The OA of synthetic effluents containing with RRB, NB and YN were investigated in order to find the best conditions for the removal of color and organic content of the dye. According to the experimental results, the process of OA is suitable for decolorization of wastewaters containing these textile dyes due to electrocatalytic properties of DDB and Pt anodes. Removal of the organic load was more efficient at DDB, in all cases; where the dyes were degraded to aliphatic carboxylic acids at the end of the electrolysis. Energy requirements for the removal of color during OA of solutions of RRB, NB and YN depends mainly on the operating conditions, for example, RRB passes of 3.30 kWh m-3 at 20 mA cm-2 for 4.28 kWh m-3 at 60 mA cm-2 (pH = 1); 15.23 kWh m-3 at 20 mA cm-2 to 24.75 kWh m-3 at 60 mA cm-2 (pH 4.5); 10.80 kWh m-3 at 20 mA cm-2 to 31.5 kWh m-3 at 60 mA cm-2 (pH = 8) (estimated data for volume of treated effluent). On the other hand, in the study of OA of produced water effluent generated by petrochemical industry, galvanostatic electrolysis using DDB led to the complete removal of COD (98%), due to large amounts of hydroxyl radicals and peroxodisulphates generated from the oxidation of water and sulfates in solution, respectively. Thus, the rate of COD removal increases with increasing applied current density (15-60 mAcm-2 ). Moreover, at Pt electrode, approximately 50% removal of the organic load was achieved by applying from 15 to 30 mAcm-2 while 80% of COD removal was achieved for 60 mAcm-2 . Thus, the results obtained in the application of this technology were satisfactory depending on the electrocatalytic materials and operating conditions used for removal of organic load (petrochemical and textile effluents) as well as for the removal of color (in the case of textile effluents). Therefore, the applicability of electrochemical treatment can be considered as a new alternative like pretreatment or treatment of effluents derived from textiles and petrochemical industries.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study consists in the structure elaboration and the ePoste project communicationprotocol, which is a system of monitoring by wireless communication with the aim tosensor and act with one or many public lighting points, and also the treatment of data todetect the activity in the sensors located on the posts. Previously the communication withsensors were made in locus and when data collect was necessary or the performance inthe devices, the operator had to move until the net place. Accordingly, the purpose has theconcern to increase the system dynamic, achieving the possible integrations with the systemsalready available to the lighting management. The same technology of communicationbetween the sensors are considerate, using the ZigBee protocol running on the meshnet, the communication with this net is made be internet through a gateway by GPRS,device with two basics functionalities, which bypass for data and the firmware update inthe sensor. This functionality test of data management is being tested; integrate way withlocal net of sensors and the internet data server operates. The protocol developed, besidesincorporating the ZigBee, that it is formation of framework in lower level, where definesbeginning, size and errors check, as well as the communication of sensor with the concentrator,which it is encapsulated in ZigBee; also the protocol of upper level, where thatit is the names, it was developed a platform of service to meet GET and POST requestsbeneath HTTP protocol, this service is implemented in the data server, which availablethe communication with the clients systems, in case, lighting management systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High dependability, availability and fault-tolerance are open problems in Service-Oriented Architecture (SOA). The possibility of generating software applications by integrating services from heterogeneous domains, in a reliable way, makes worthwhile to face the challenges inherent to this paradigm. In order to ensure quality in service compositions, some research efforts propose the adoption of verification techniques to identify and correct errors. In this context, exception handling is a powerful mechanism to increase SOA quality. Several research works are concerned with mechanisms for exception propagation on web services, implemented in many languages and frameworks. However, to the extent of our knowledge, no works found evaluates these mechanisms in SOA with regard to the .NET framework. The main contribution of this paper is to evaluate and to propose exception propagation mechanisms in SOA to applications developed within the .NET framework. In this direction, this work: (i)extends a previous study, showing the need to propose a solution to the exception propagation in SOA to applications developed in .NET, and (ii) show a solution, based in model obtained from the results found in (i) and that will be applied in real cases through of faults injections and AOP techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposed the study of the treatment of a synthetic wastewater contaminated with BTX by electro-oxidation batch with the anode of Ti/PbO2, and the adsorption of BTX using expanded perlite as adsorbent material, and to evaluate the best operating conditions both methods in order to perform a sequential treatment (adsorption and electro-oxidation) and achieve greater efficiency in the removal of the compounds. The operating conditions were measured: temperature, current density and applied amount of the adsorbent material, by UV-VIS analysis and Demand Chemical oxygen demand (COD). According to the experimental results, the electro-oxidative treatment was efficient in the degradation of the compounds BTX (benzene, toluene and xylenes) in synthetic sewage due to the electrochemical properties of the anode of Ti/PbO2. The applied current density and temperature promoted increased efficiency of COD removal, reaching obtain percentages greater than 70%. In the adsorption process, the temperature increase was not a factor in the removal of organic matter, while the increase in the amount of adsorbent material led to an increase in the percentage removal, obtaining 66.30% using 2 g of adsorbent. The selected operating conditions of both treatments performed separately take into account the removal efficiency of organic matter, and the low energy consumption and operating costs, so the sequential treatment were satisfactory reaching 87.26% of COD removal using adsorption as a pretreatment. Quantification of BTX through the analysis of gas chromatography at the end of the treatments also confirmed the removal efficiency of organic compounds, giving outstanding advantages to sequential treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The produce of waste and the amount of the water produced coming from activities of petroleum production and extraction has been a biggest challenge for oil companies with respect to environmental compliance due to toxicity. The discard or the reuse this effluent containing organic compounds as BTEX (benzene, toluene, ethylbenzene and xylene) can cause serious environmental and human health problems. Thus, the objective this paper was study the performance of two process (separately and sequential) in one synthetic effluent for the benzene, toluene and xylene removal (volatile hydrocarbons presents in the produced water) through of electrochemical treatment using Ti/Pt electrode and exchange resin ionic used in the adsorption process. The synthetic solution of BTX was prepared with concentration of 22,8 mg L-1, 9,7 mg L-1 e 9,0 mg L-1, respectively, in Na2SO4 0,1 mol L-1. The experiments was developed in batch with 0.3 L of solution at 25ºC. The electrochemical oxidation process was accomplished with a Ti/Pt electrode with different current density (J = 10, 20 e 30 mA.cm-2). In the adsorption process, we used an ionic exchange resin (Purolite MB 478), using different amounts of mass (2,5, 5 and 10 g). To verify the process of technics in the sequential treatment, was fixed the current density at 10 mA cm-2 and the resin weight was 2.5 g. Analysis of UV-VIS spectrophotometry, chemical oxygen demand (COD) and gas chromatography with selective photoionization detector (PID) and flame ionization (FID), confirmed the high efficiency in the removal of organic compounds after treatment. It was found that the electrochemical process (separate and sequential) is more efficient than absorption, reaching values of COD removal exceeding 70%, confirmed by the study of the cyclic voltammetry and polarization curves. While the adsorption (separately), the COD removal did not exceed 25,8%, due to interactions resin. However, the sequential process (electrochemical oxidation and adsorption) proved to be a suitable alternative, efficient and cost-effectiveness for the treatment of effluents petrochemical.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Textile industry has been a cause of environmental pollution, mainly due to the generation of large volumes of waste containing high organic loading and intense color. In this context, this study evaluated the electrochemical degradation of synthetic effluents from textile industry containing Methylene Blue (AM) dye, using Ti/IrO2-Ta2O5 and Ti/Pt anodes, by direct and indirect (active chlorine) electrooxidation. We evaluated the influence of applied current density (20, 40 and 60 mA/cm2 ), and the presence of different concentrations of electrolyte (NaCl and Na2SO4), as well as the neutral and alkaline pH media. The electrochemical treatment was conducted in a continuous flow reactor, in which the electrolysis time of the AM 100 ppm was 6 hours. The performance of electrochemical process was evaluated by UV-vis spectrophotometry, chemical oxygen demand (COD) and total organic carbon (TOC). The results showed that with increasing current density, it was possible to obtain 100 % of color removal at Ti/IrO2-Ta2O5 and Ti/Pt electrodes. Regarding the color removal efficiency, increasing the concentration of electrolyte promotes a higher percentage of removal using 0,02 M Na2SO4 and 0,017 M NaCl. Concerning to the aqueous medium, the best color removal results were obtained in alkaline medium using Ti/Pt. In terms of organic matter, 86 % was achieved in neutral pH medium for Ti/Pt; while a 30 % in an alkaline medium. To understand the electrochemical behavior due to the oxygen evolution reaction, polarization curves were registered, determining that the presence of NaCl in the solution favored the production of active chlorine species. The best results in energy consumption and cost were obtained by applying lower current density (20 mA/cm2 ) in 6 hours of electrolysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Compared to conventional composites, polymer matrix nanocomposites typically exhibit enhanced properties at a significantly lower filler volume fraction. Studies published in the literature indicate t hat the addition of nanosilicate s can increase the resistance to flame propagation in polymers. In this work, a treatment of montmorillonite (MMT) nano clay and the effect of its ad dition o n flame propagation characteristics of vinyl ester were studied. The resea rch was conducted in two stages. The first stage focused on the purification and activation of the MMT clay collected from a natural deposit to improve compatibility with the polymer matrix . Clay modification with sodium acetate was also studied to improve particle dispersion in the polymer. The second step was focused on the effect of the addition of the treated clay on nanocomposites ’ properties. Nanocomposites with clay con tents of 1, 2, 4 wt. % were processed. T he techniques for the characterization of the clay included X - ray fluorescence (XRF), X - r ay d iffraction (XRD), thermogravimetric a nalysis (TGA), d ifferential scanning c alorimetry (DSC) , s urface area (BET) and Fourier transform infrared spectroscopy (FTIR). For t he characterization of the nanocomposites , the techniques used were thermogravimetric a nalysis (TGA) , differential scanning c alorimetry (DSC), Fourier transform infrared spectroscopy (FTIR) , scanning electron mi croscopy (SEM), transmission electron m icroscopy (TEM), and the determination of tensile strength, modulus of elasticity and resistance to flame propagation. According to the results, the purification and activation treatment with freeze - drying used in thi s work for the montmorillonite clay was efficient to promote compatibility and dispersion in the polymer matrix as evidenced by the characterization of the nanocomposite s . It was also observed that the clay modifica tion using sodium acetate did not produce any significant effect to improve compatibilization of the clay with the polymer. The addition of the treated MMT resulted in a reduction of up to 53% in the polymer flame propagation speed and did not affect the mechanical tensile strength and modulus o f elas ticity of the polymer, indicating compatibility between the clay and polymer. The effectiveness in reducing flame propagation speed peaked for nanocomposites with 2 wt. % clay, indicating that this is the optimum clay concentration for this property. T he clay treatment used in this work enables the production of vinylester matrix nanocomposites with flame - retardancy properties .

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The performance of algorithms for fault location i n transmission lines is directly related to the accuracy of its input data. Thus, fa ctors such as errors in the line parameters, failures in synchronization of oscillographic recor ds and errors in measurements of voltage and current can significantly influence the accurac y of algorithms that use bad data to indicate the fault location. This work presents a new method ology for fault location in transmission lines based on the theory of state estimation in or der to determine the location of faults more accurately by considering realistic systematic erro rs that may be present in measurements of voltage and current. The methodology was implemente d in two stages: pre-fault and post- fault. In the first step, assuming non-synchronized data, the synchronization angle and positive sequence line parameters are estimated, an d in the second, the fault distance is estimated. Besides calculating the most likely faul t distance obtained from measurement errors, the variance associated with the distance f ound is also determined, using the errors theory. This is one of the main contributions of th is work, since, with the proposed algorithm, it is possible to determine a most likely zone of f ault incidence, with approximately 95,45% of confidence. Tests for evaluation and validation of the proposed algorithm were realized from actual records of faults and from simulations of fictitious transmission systems using ATP software. The obtained results are relevant to show that the proposed estimation approach works even adopting realistic variances, c ompatible with real equipments errors.