126 resultados para Ações verticais - Distribuição
Resumo:
The usual programs for load flow calculation were in general developped aiming the simulation of electric energy transmission, subtransmission and distribution systems. However, the mathematical methods and algorithms used by the formulations were based, in majority, just on the characteristics of the transmittion systems, which were the main concern focus of engineers and researchers. Though, the physical characteristics of these systems are quite different from the distribution ones. In the transmission systems, the voltage levels are high and the lines are generally very long. These aspects contribute the capacitive and inductive effects that appear in the system to have a considerable influence in the values of the interest quantities, reason why they should be taken into consideration. Still in the transmission systems, the loads have a macro nature, as for example, cities, neiborhoods, or big industries. These loads are, generally, practically balanced, what reduces the necessity of utilization of three-phase methodology for the load flow calculation. Distribution systems, on the other hand, present different characteristics: the voltage levels are small in comparison to the transmission ones. This almost annul the capacitive effects of the lines. The loads are, in this case, transformers, in whose secondaries are connected small consumers, in a sort of times, mono-phase ones, so that the probability of finding an unbalanced circuit is high. This way, the utilization of three-phase methodologies assumes an important dimension. Besides, equipments like voltage regulators, that use simultaneously the concepts of phase and line voltage in their functioning, need a three-phase methodology, in order to allow the simulation of their real behavior. For the exposed reasons, initially was developped, in the scope of this work, a method for three-phase load flow calculation in order to simulate the steady-state behaviour of distribution systems. Aiming to achieve this goal, the Power Summation Algorithm was used, as a base for developing the three phase method. This algorithm was already widely tested and approved by researchers and engineers in the simulation of radial electric energy distribution systems, mainly for single-phase representation. By our formulation, lines are modeled in three-phase circuits, considering the magnetic coupling between the phases; but the earth effect is considered through the Carson reduction. It s important to point out that, in spite of the loads being normally connected to the transformer s secondaries, was considered the hypothesis of existence of star or delta loads connected to the primary circuit. To perform the simulation of voltage regulators, a new model was utilized, allowing the simulation of various types of configurations, according to their real functioning. Finally, was considered the possibility of representation of switches with current measuring in various points of the feeder. The loads are adjusted during the iteractive process, in order to match the current in each switch, converging to the measured value specified by the input data. In a second stage of the work, sensibility parameters were derived taking as base the described load flow, with the objective of suporting further optimization processes. This parameters are found by calculating of the partial derivatives of a variable in respect to another, in general, voltages, losses and reactive powers. After describing the calculation of the sensibility parameters, the Gradient Method was presented, using these parameters to optimize an objective function, that will be defined for each type of study. The first one refers to the reduction of technical losses in a medium voltage feeder, through the installation of capacitor banks; the second one refers to the problem of correction of voltage profile, through the instalation of capacitor banks or voltage regulators. In case of the losses reduction will be considered, as objective function, the sum of the losses in all the parts of the system. To the correction of the voltage profile, the objective function will be the sum of the square voltage deviations in each node, in respect to the rated voltage. In the end of the work, results of application of the described methods in some feeders are presented, aiming to give insight about their performance and acuity
Resumo:
Most algorithms for state estimation based on the classical model are just adequate for use in transmission networks. Few algorithms were developed specifically for distribution systems, probably because of the little amount of data available in real time. Most overhead feeders possess just current and voltage measurements at the middle voltage bus-bar at the substation. In this way, classical algorithms are of difficult implementation, even considering off-line acquired data as pseudo-measurements. However, the necessity of automating the operation of distribution networks, mainly in regard to the selectivity of protection systems, as well to implement possibilities of load transfer maneuvers, is changing the network planning policy. In this way, some equipments incorporating telemetry and command modules have been installed in order to improve operational features, and so increasing the amount of measurement data available in real-time in the System Operation Center (SOC). This encourages the development of a state estimator model, involving real-time information and pseudo-measurements of loads, that are built from typical power factors and utilization factors (demand factors) of distribution transformers. This work reports about the development of a new state estimation method, specific for radial distribution systems. The main algorithm of the method is based on the power summation load flow. The estimation is carried out piecewise, section by section of the feeder, going from the substation to the terminal nodes. For each section, a measurement model is built, resulting in a nonlinear overdetermined equations set, whose solution is achieved by the Gaussian normal equation. The estimated variables of a section are used as pseudo-measurements for the next section. In general, a measurement set for a generic section consists of pseudo-measurements of power flows and nodal voltages obtained from the previous section or measurements in real-time, if they exist -, besides pseudomeasurements of injected powers for the power summations, whose functions are the load flow equations, assuming that the network can be represented by its single-phase equivalent. The great advantage of the algorithm is its simplicity and low computational effort. Moreover, the algorithm is very efficient, in regard to the accuracy of the estimated values. Besides the power summation state estimator, this work shows how other algorithms could be adapted to provide state estimation of middle voltage substations and networks, namely Schweppes method and an algorithm based on current proportionality, that is usually adopted for network planning tasks. Both estimators were implemented not only as alternatives for the proposed method, but also looking for getting results that give support for its validation. Once in most cases no power measurement is performed at beginning of the feeder and this is required for implementing the power summation estimations method, a new algorithm for estimating the network variables at the middle voltage bus-bar was also developed
Resumo:
The usual programs for load flow calculation were in general developped aiming the simulation of electric energy transmission, subtransmission and distribution systems. However, the mathematical methods and algorithms used by the formulations were based, in majority, just on the characteristics of the transmittion systems, which were the main concern focus of engineers and researchers. Though, the physical characteristics of these systems are quite different from the distribution ones. In the transmission systems, the voltage levels are high and the lines are generally very long. These aspects contribute the capacitive and inductive effects that appear in the system to have a considerable influence in the values of the interest quantities, reason why they should be taken into consideration. Still in the transmission systems, the loads have a macro nature, as for example, cities, neiborhoods, or big industries. These loads are, generally, practically balanced, what reduces the necessity of utilization of three-phase methodology for the load flow calculation. Distribution systems, on the other hand, present different characteristics: the voltage levels are small in comparison to the transmission ones. This almost annul the capacitive effects of the lines. The loads are, in this case, transformers, in whose secondaries are connected small consumers, in a sort of times, mono-phase ones, so that the probability of finding an unbalanced circuit is high. This way, the utilization of three-phase methodologies assumes an important dimension. Besides, equipments like voltage regulators, that use simultaneously the concepts of phase and line voltage in their functioning, need a three-phase methodology, in order to allow the simulation of their real behavior. For the exposed reasons, initially was developped, in the scope of this work, a method for three-phase load flow calculation in order to simulate the steady-state behaviour of distribution systems. Aiming to achieve this goal, the Power Summation Algorithm was used, as a base for developping the three phase method. This algorithm was already widely tested and approved by researchers and engineers in the simulation of radial electric energy distribution systems, mainly for single-phase representation. By our formulation, lines are modeled in three-phase circuits, considering the magnetic coupling between the phases; but the earth effect is considered through the Carson reduction. Its important to point out that, in spite of the loads being normally connected to the transformers secondaries, was considered the hypothesis of existence of star or delta loads connected to the primary circuit. To perform the simulation of voltage regulators, a new model was utilized, allowing the simulation of various types of configurations, according to their real functioning. Finally, was considered the possibility of representation of switches with current measuring in various points of the feeder. The loads are adjusted during the iteractive process, in order to match the current in each switch, converging to the measured value specified by the input data. In a second stage of the work, sensibility parameters were derived taking as base the described load flow, with the objective of suporting further optimization processes. This parameters are found by calculating of the partial derivatives of a variable in respect to another, in general, voltages, losses and reactive powers. After describing the calculation of the sensibility parameters, the Gradient Method was presented, using these parameters to optimize an objective function, that will be defined for each type of study. The first one refers to the reduction of technical losses in a medium voltage feeder, through the installation of capacitor banks; the second one refers to the problem of correction of voltage profile, through the instalation of capacitor banks or voltage regulators. In case of the losses reduction will be considered, as objective function, the sum of the losses in all the parts of the system. To the correction of the voltage profile, the objective function will be the sum of the square voltage deviations in each node, in respect to the rated voltage. In the end of the work, results of application of the described methods in some feeders are presented, aiming to give insight about their performance and acuity
Resumo:
The reconfiguration of a distribution network is a change in its topology, aiming to provide specific operation conditions of the network, by changing the status of its switches. It can be performed regardless of any system anomaly. The service restoration is a particular case of reconfiguration and should be performed whenever there is a network failure or whenever one or more sections of a feeder have been taken out of service for maintenance. In such cases, loads that are supplied through lines sections that are downstream of portions removed for maintenance may be supplied by the closing of switches to the others feeders. By classical methods of reconfiguration, several switches may be required beyond those used to perform the restoration service. This includes switching feeders in the same substation or for substations that do not have any direct connection to the faulted feeder. These operations can cause discomfort, losses and dissatisfaction among consumers, as well as a negative reputation for the energy company. The purpose of this thesis is to develop a heuristic for reconfiguration of a distribution network, upon the occurrence of a failure in this network, making the switching only for feeders directly involved in this specific failed segment, considering that the switching applied is related exclusively to the isolation of failed sections and bars, as well as to supply electricity to the islands generated by the condition, with significant reduction in the number of applications of load flows, due to the use of sensitivity parameters for determining voltages and currents estimated on bars and lines of the feeders directly involved with that failed segment. A comparison between this process and classical methods is performed for different test networks from the literature about networks reconfiguration
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico
Resumo:
This works presents a proposal to make automatic the identification of energy thefts in the meter systems through Fuzzy Logic and supervisory like SCADA. The solution we find by to collect datas from meters at customers units: voltage, current, power demand, angles conditions of phasors diagrams of voltages and currents, and taking these datas by fuzzy logic with expert knowledge into a fuzzy system. The parameters collected are computed by fuzzy logic, in engineering alghorithm, and the output shows to user if the customer researched may be consuming electrical energy without to pay for it, and these feedbacks have its own membership grades. The value of this solution is a need for reduce the losses that already sets more than twenty per cent. In such a way that it is an expert system that looks for decision make with assertivity, and it looks forward to find which problems there are on site and then it wont happen problems of relationship among the utility and the customer unit. The database of an electrical company was utilized and the datas from it were worked by the fuzzy proposal and algorithm developed and the result was confirmed
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Resumo:
The aim of this approach is to describe the design and construction of a low-cost automated water sampler prototype. In recent years, there is an increasing need on the use of automated equipments for hydro climatic variables to be use in urban and rural environments. Such devices are always used to provide measured information which is of crucial importance on the development of water resources strategies at watershed scale. Actually, many research and water public institutions have been using these kinds of equipments. In most of the cases, automated equipments are expensive and need to be imported, generating a situation of technologic dependency. The prototype is based on an electronic system which controls a peristaltic pump functioning, five solenoid valves and an ultrasonic sensor connected to a datalloger. An interface with the user allows communication with a PC, when the equipment functioning parameters can be provided. The equipment has a hydraulic module composed by a 12V peristaltic pump connected to a distribution circuit composed by five solenoid valves, one of them being used to clean the circuit before each sampling procedure. Samples are collected by four 1.95 polyethylene bottles. The sampler body was made of acrylic material, with a cylindrical shape, and dimensions 0.72 m and 0.38 m height and diameter, respectively. The weight of the equipment without samples is approximately 15 kg, which infers to its portability. The prototype development total cost budget was approximately US$ 1,560.00. Laboratory tests aimed to evaluate the equipment performance and functioning demonstrated satisfactory results
Resumo:
This research study deals with the production and distribution of drinking water with quality and safety in order to meet the needs of the Man. Points out the limitations of the methodology for assessing water quality in use today. Approaches the recommendations of the World Health Organization (WHO) for adoption, by the companies responsible for producing and distributing water, of assessment methodologies and risk management (HACCP), in order to ensure the quality and safety of water drinking. Suggests strategies for implementing the plan for water safety plan. Uses the process of water production, composed by Maxaranguape river basin, the water treatment plant and distribution system, which is part of the Plan for Expansion of the Supply System of Natal, as case study. The results, it was possible to devise strategies for implementation of the Water Safety Plan (WSP), which comprises the following steps: a) a preliminary stage. b) assessment system. c) process monitoring. d) management plan and e) validation and verification of the PSA. At each stage are included actions for its implementation. The implementation of the PSA shows a new type of water production, in which the fountain as a whole (watershed and point of capture), the Water Treatment Plant (WTP) and distribution, shall compose the production process, over which to build quality and safety of the final product (drinking water)
Resumo:
The state of Rio Grande do Norte, possessor of an extremely irregular regime of rains, has the necessity of enlarge and specify the researches about its own hydro-climatic conditions, to achieve trustworthy results that are able to minimize the adversities imposed by these conditions and make possible the implementation of a better planning in the economic activities and of subsistence that somehow utilize of the multiple uses of hydro resources of the State. This way, the daily values observed from the pluviometric series of 166 posts, with 45 years uninterrupted of historic data, were adjusted to the incomplete gamma function to the determination of the probability of rain in the 36 period of ten days in which the year was divided. To the attainment of the α and β parameters of this function it was applied the method of the maximum verisimilitude allowing, in the end, to analyze the temporal and spatial distribution of the rain in the level of 75% of probability. The values of potential evapo-transpiration were calculated by the Linacre method that, through the SURFER software, were confronted with the dependant rain, obtaining, in this way, the spatialization of the potential hydro availability, which the values can be known to any period of ten days of the year, city and/or region of the state of Rio Grande do Norte. With the identification of the main meteorological systems that act in the State, we sought to better comprehend how this systems interfere, in the irregular regime of rain, in the situations of several clime in the major part of Rio Grande do Norte and in the hydro regional balance. And, finally, with these data in hand and with the generated maps, we verified that space-temporal distribution of the rain and of the potential hydro availability were heterogeneous in the whole State, mainly in the West and Central regions, inserted in potiguar s semi-arid, which, after the period of the rains station, suffers with dry season and length drought during the rest of the year
Resumo:
With the need to deploy management and monitoring systems of natural resources in areas susceptible to environmental degradation, as is the case of semiarid regions, several works have been developed in order to find effective models and technically and economically viable. Therefore, this study aimed to estimate the daily actual evapotranspiration (ETr) through the application of the Surface Energy Balance Algorithm for Land (SEBAL), from remote sensing products, in a semiarid region, Seridó of the Rio Grande do Norte, and do the validation of these estimates using ETr values obtained by the Penman-Monteith (standard method of the Food and Agriculture Organization-FAO). The SEBAL is based on energy balance method, which allows obtaining the vertical latent heat flux (LE) with orbital images and, consequently, of the evapotranspiration through the difference of flows, also vertical, of heat in the soil (G), sensitive heat (H) and radiation balance (Rn). The study area includes the surrounding areas of the Dourado reservoir, located in the Currais Novos/RN city. For the implementation of the algorithm were used five images TM/Landsat-5. The work was divided in three chapters in order to facilitate a better discussion of each part of the SEBAL processing, distributed as follows: first chapter addressing the spatio-temporal variability of the biophysical variables; second chapter dealing with spatio-temporal distribution of instant and daily radiation balance; and the third chapter discussing the heart of the work, the daily actual evapotranspiration estimation and the validation than to the study area
Resumo:
The aim of this study is to characterize and evaluate the Macro System of Regional Water Distribution Natal North (RNN) and Southern Regional Natal (RNS), covering 35% and 65% respectively of the Natal-RN City. The terms of the quality and quantity of water (surface and groundwater) were also evaluated in order to adjust the parameters that contribute to proper distribution and control in water reserves. The methodology of the work took place from collecting volumetric data of production capacity and distribution of the two treatment plants for Regional as well as the flow rates of wells. Yet the quantitative capacity of reservation, distribution and consumption of the main reservoirs, population numbers and consumption of members neighborhoods were collected. Data were tabulated and used in computational simulator EPANET to diagnose possible through the water balance, the offers and demands on the water supply system in the neighborhoods of the capital, linking them to specific distribution points. We also evaluated the wells in the levels of nitrate in water consumed. As a result it was found that some neighborhoods in the South Regional Natal, was ranked as critical supply situation: City of Hope, Lagoa Nova and Nova Descoberta, where demand exceeds supply. While in most Northern Regional Natal present deficiency in the supply system as: Lagoa Azul, the Parque dos Coqueiros, igapó, Amarante and Salinas. The rates of nitrate in the city were significant, but manageable with corrective and preventive measures. The averages were 12 mg /l-N in Candelária, 10 mg/l-N in Lagoa Nova, 9 mg/l-N in Satelite, 20 mg/l-N in Gramore and 15 mg/l-N in N. Sra. Apresentação. Therefore proper distribution of water abstracted and implementation of quality control ensures the supply required by the system, associated with preservation of Water Resources of the Metropolitan Region of Natal
Resumo:
This dissertation presents a methodology to the optimization of a predial system of cold water distribution. It s about a study of a case applied to the Tropical Buzios Residential Condominium, located in the Búzio s Beach, Nísia Floresta city, the east coast of the Rio Grande do Norte state, twenty kilometers far from Natal. The design of cold water distribution networks according to Norm NBR 5626 of the ABNT - Brazilian Association of Techniques Norms, does not guarantee that the joined solution is the optimal solution of less cost. It s necessary the use of an optimization methodology, that supplies us, between all the possible solutions, the minimum cost solution. In the optimization process of the predial system of water distribution of the Tropical Búzios Condominium, is used Method Granados, that is an iterative algorithm of optimization, based on the Dynamic Programming, that supplies the minimum cost s network, in function of the piezometric quota of the reservoir. For the application of this Method in ramifies networks, is used a program of computer in C language. This process is divided in two stages: attainment of the previous solution and reduction of the piezometric quota of headboard. In the attainment of the previous solution, the minors possible diameters are used that guarantee the limit of maximum speed and the requirements of minimum pressures. The piezometric quota of headboard is raised to guarantee these requirements. In the second stage of the Granados Method, an iterative process is used and it objective is to reduce the quota of headboard gradually, considering the substitution of stretches of the network pipes for the subsequent diameters, considering a minimum addition of the network cost. The diameter change is made in the optimal stretch that presents the lesser Exchange Gradient. The process is locked up when the headboard quota of desired is reached. The optimized network s material costs are calculated, and is made the analysis of the same ones, through the comparison with the conventional network s costs
Resumo:
In recent decades, humanity has become increasingly concerned with environmental problems. Proofs of this are increasing initiatives in civil society organizations, private institutions and government actions, either local, state or national actions to promote environmental protection. The goal of this research is to contribute to the formation of citizens more aware of their responsibilities to sustainable development issues, simultaneously to their learning of physics in the secondary school. Thus, we have designed a research project that aims to evaluate the effectiveness of the adoption of the concept of sustainable development as a central theme in physics classes in high school. From this goal, we designed, implemented and evaluate lesson plans that aim not only to construct and apply the concept of energy, but also to understand their transformations and conservation law, as well as their processes of production, distribution and consume in the context of physical laws in which it is involved. Then, it was deliberately provided to students, during classes, to read, interpret and produce texts, by this way being able to think and start to have a critical view of the world around him, as well as absorb the energy concept and understand his occurrence in phenomena of nature and in technologies. The approach used for this was that constraining science, technology, society and environment - STSE. This teaching methodology has been applied in the IFRN Ipanguaçu campus, for students of two classes of first year of high school integrated course in agroecology and in technical computing. The survey results show the effectiveness of both methods with respect to the viewpoints of students in relation to the guidelines of sustainable development and the learning of physics content proposed. It is hoped with this dissertation to contribute to the formation of future men and women as citizens environmentally friendly, but also as a source of inspiration for teachers who wish to foster in its students such a critical position about civic education, from their classes
Resumo:
Youngsters and teenagers are still a very vulnerable group of DST/AIDS. In order to combat this vulnerability the community intervention project being developed in Mãe Luiza neighborhood in the city of Natal-RN, entitled Strengthening Community Action Network for Prevention in HIV/AIDS: knowledge and Intervene emerged, popularly known as Project Viva Mãe Luiza. The project develops workshops of educomunication whose approach involves the DST/AIDS subject with the following media: video, photography, and theater playbook. This research integrates the activities of the project and has as main objective to investigate how strategies and practices of media communication developed in Project Viva Mãe Luiza through workshops of educomunication, assisted learning for the prevention of DST/AIDS and contributed to the reduction of vulnerability to DST/AIDS among adolescents and young participants of the project residents of Mãe Luiza community. The methodological basis was based on intervention research, with the technique of gathering daily field data, literature and documentary, in-depth interviews and ethnographic observation. The qualitative analysis was based on the monitoring of video workshops, photography, theater and primer, respectively, crossed by transverse to the prevention of DST/AIDS, conducted between June 2012 and December 2013 issues. Interviews with eight multipliers, aiming to understand their perceptions of vulnerability, prevention, multiplication and use of media that were part of the project were conducted. The analyzes show that learning workshops educomunication community health repercussions both in the development of individual skills in communication as changing perceptions about the vulnerabilities to which they are exposed, the awareness about prevention at the individual and differentiated actions multiplication in the community