50 resultados para controle de fluxo de potência


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents a description of models development at DigSILENT PowerFactoryTM program for the transient stability study in power systems with wind turbine. The main goal is to make available means to use a dynamic simulation program in power systems, widely published, and utilize it as a tool that helps in programs results evaluations used for this intent. The process of simulations and analyses results starts after the models setting description phase. The results obtained by the DigSILENT PowerFactoryTM and ATP, program chosen to the validation also international recognized, are compared during this phase. The main tools and guide lines of PowerFactoryTM program use are presented here, directing these elements to the solution of the approached problem. For the simulation it is used a real system which it will be connected a wind farm. Two different technologies of wind turbines were implemented: doubly-fed induction generator with frequency converter, connecting the rotor to the stator and to the grid, and synchronous wind generator with frequency converter, interconnecting the generator to the grid. Besides presenting the basic conceptions of dynamic simulation, it is described the implemented control strategies and models of turbine and converters. The stability of the wind turbine interconnected to grid is analyzed in many operational conditions, resultant of diverse kinds of disturbances

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The stability of synchronous generators connected to power grid has been the object of study and research for years. The interest in this matter is justified by the fact that much of the electricity produced worldwide is obtained with the use of synchronous generators. In this respect, studies have been proposed using conventional and unconventional control techniques such as fuzzy logic, neural networks, and adaptive controllers to increase the stabilitymargin of the systemduring sudden failures and transient disturbances. Thismaster thesis presents a robust unconventional control strategy for maintaining the stability of power systems and regulation of output voltage of synchronous generators connected to the grid. The proposed control strategy comprises the integration of a sliding surface with a linear controller. This control structure is designed to prevent the power system losing synchronism after a sudden failure and regulation of the terminal voltage of the generator after the fault. The feasibility of the proposed control strategy was experimentally tested in a salient pole synchronous generator of 5 kVA in a laboratory structure

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Este projeto propõe desenvolver e implementar um controlador para o sistema de refrigeração da tocha indutiva a plasma térmico. Este processo é feito a partir da medição da temperatura através de um sensor do sistema de refrigeração. O sinal produzido será enviado para uma entrada analógica do microcontrolador da família PIC, que utilizando os conceitos de lógica fuzzy, controla a velocidade de um motor bomba. Este é responsável por diminuir ou aumentar o fluxo circulante de água que passa pela bobina, pelo corpo da tocha e pelo flange de fixação, deixando-os na temperatura desejada. A velocidade desta bomba será controlada por um inversor de frequência. O microcontrolador, também, acionará um ventilador caso exceda a temperatura de referência. A proposta inicial foi o desenvolvimento do controle da temperatura da bobina de uma tocha indutiva a plasma, mas com algumas adequações, foi possível também aplicar no corpo da tocha. Essa tocha será utilizada em uma planta de tratamento de resíduos industriais e efluentes petroquímicos. O controle proposto visa garantir as condições físicas necessárias para tocha de plasma, mantendo a temperatura da água em um determinado nível que permita o resfriamento sem comprometer, no entanto, o rendimento do sistema. No projeto será utilizada uma tocha de plasma com acoplamento indutivo (ICPT), por ter a vantagem de não possuir eletrodos metálicos internos sendo erodidos pelo jato de plasma, evitando uma possível contaminação, e também devido à possibilidade do reaproveitamento energético através da cogeração de energia. O desenvolvimento da tecnologia a plasma na indústria de tratamento de resíduos vem obtendo bons resultados. Aplicações com essa tecnologia têm se tornado cada vez mais importantes por reduzir, em muitos casos, a produção de resíduos e o consumo de energia em vários processos industriais

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The scarcity of natural resources and the search for alternative energy sources promote a rapid change in the energy world. Among the renewable energy sources, solar energy is the most promising, presenting technology of greatest growth rate nowadays. Researchers around the world are seeking ways to facilitate their progress, developing technologies with higher efficiency and lower cost. As a contribution to global progress, this master thesis proposes the development of a strategy of maximum power tracking based on perturbation and observation method for photovoltaic systems. The proposed control strategy is based on active power balance of the system, with a reduced number of sensors. It also allows the PV system to act as a regulator of the power quality at the point of commom coupling (PCC), compensating the harmonic distortion and power factor of the current netw

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Slugging is a well-known slugging phenomenon in multiphase flow, which may cause problems such as vibration in pipeline and high liquid level in the separator. It can be classified according to the place of its occurrence. The most severe, known as slugging in the riser, occurs in the vertical pipe which feeds the platform. Also known as severe slugging, it is capable of causing severe pressure fluctuations in the flow of the process, excessive vibration, flooding in separator tanks, limited production, nonscheduled stop of production, among other negative aspects that motivated the production of this work . A feasible solution to deal with this problem would be to design an effective method for the removal or reduction of the system, a controller. According to the literature, a conventional PID controller did not produce good results due to the high degree of nonlinearity of the process, fueling the development of advanced control techniques. Among these, the model predictive controller (MPC), where the control action results from the solution of an optimization problem, it is robust, can incorporate physical and /or security constraints. The objective of this work is to apply a non-conventional non-linear model predictive control technique to severe slugging, where the amount of liquid mass in the riser is controlled by the production valve and, indirectly, the oscillation of flow and pressure is suppressed, while looking for environmental and economic benefits. The proposed strategy is based on the use of the model linear approximations and repeatedly solving of a quadratic optimization problem, providing solutions that improve at each iteration. In the event where the convergence of this algorithm is satisfied, the predicted values of the process variables are the same as to those obtained by the original nonlinear model, ensuring that the constraints are satisfied for them along the prediction horizon. A mathematical model recently published in the literature, capable of representing characteristics of severe slugging in a real oil well, is used both for simulation and for the project of the proposed controller, whose performance is compared to a linear MPC

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of Field Programmable Gate Array (FPGA) for development of digital control strategies for power electronics applications has aroused a growing interest of many researchers. This interest is due to the great advantages offered by FPGA, which include: lower design effort, high performance and highly flexible prototyping. This work proposes the development and implementation of an unified one-cycle controller for boost CFP rectifier based on FPGA. This controller can be applied to a total of twelve converters, six inverters and six rectifiers defined by four single phase VSI topologies and three voltage modulation types. The topologies considered in this work are: full-bridge, interleaved full-bridge, half-bridge and interleaved half-bridge. While modulations are classified in bipolar voltage modulation (BVM), unipolar voltage modulation (UVM) and clamped voltage modulation (CVM). The proposed project is developed and prototyped using tools Matlab/Simulink® together with the DSP Builder library provided by Altera®. The proposed controller was validated with simulation and experimental results

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The continuous gas lift method is the main artificial lifting method used in the oil industry for submarine wells, due to its robustness and the large range of flow rate that the well might operate. Nowadays, there is a huge amount of wells producing under this mechanism. This method of elevation has a slow dynamics due to the transients and a correlation between the injected gas rate and the of produced oil rate. Electronics controllers have been used to adjust many parameters of the oil wells and also to improve the efficiency of the gas lift injection system. This paper presents a intelligent control system applied to continuous gas injection in wells, based in production s rules, that has the target of keeping the wells producing during the maximum period of time, in its best operational condition, and doing automatically all necessary adjustments when occurs some disturbance in the system. The author also describes the application of the intelligent control system as a tool to control the flow pressure in the botton of the well (Pwf). In this case, the control system actuates in the surface control valve

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study that resulted in this dissertation was developed at OU RNCE PETROBRAS, in Natal, which implemented a project of rational use and reuse of water, including use of wastewater from a Sewage Treatment Plant (STP) already in place, diluted with water from own wells for irrigation of green area of the building complex corporate enterprise. Establish a methodology that can serve as guidelines for future projects controlled reuse of water like this was the objective of this research. Been proposed, implemented and evaluated three instruments of sanitary and environmental control: 1) adaptation of sewage treatment plant and quality control of the treated effluent 2) analysis of soil-nutrient interaction in the irrigated area, 3) knowledge of the local hydrogeology, especially with regard to the direction of flow of the aquifer and location of collection wells of Companhia de Águas e Esgotos do Rio Grande do Norte (CAERN) situated in the surroundings. These instruments have proven sufficient and appropriate to ensure the levels of sanitary and environmental control proposed and studied, which were: a) control of water quality off the STP and the output of the irrigation reservoir, b) control of water quality sub surface soil and assessment of progress on soil composition, c) assessment of water quality in the aquifer. For this, we must: 1) establishing the monitoring plan of the STP and its effluent quality sampling points and defining the parameters of analysis, improve the functioning of that identifying the adequacy of flow and screening as the main factors of operational control, and increase the efficiency of the station to a relatively low cost, using additional filters, 2) propose, implement and adapt simple collectors to assess the quality of water percolating into the soil of the irrigated area, 3) determine the direction of groundwater flow in the area study and select the wells for monitoring of the aquifer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Northeastern Brazil is mainly formed by crystalline terrains (around 60% in area). Moreover, this region presents a semi-arid climate so that it is periodically subject to drought seasons. Furthermore, ground water quality extracted fromwells usually presents poor quality because of their high salinity contents. Nevertheless, ground water is still a very important source of water for human and animal consumption in this region. Well sitting in hard rocks terrains in Northeastern Brazil offers a mean success index of aboul 60%, given that a successful siting is defined by a well producing at least 0.5 m³/h. This low index reveals lack of knowledga about the true conditions of storage and percolation of ground water in crystalline rocks. Two models for structures storing and producing ground water in crystalline rocks in Northeastem Brazil have been proposed in the literature. The first model,tradnionally used for well sitting since the sixties are controlled by faults or fractures zones. This model is commonly referred, in Brazilian hydrogeological literature, as the "creek-crack" model (riacho-fenda in Portuguese). Sites appearing to present dense drainage network are preferred for water well siting - particularly at points where the drainages cross-cul each other. Field follow up work is usually based only on geological criteria. The second model is the "eluvio-alluvial through" (calha eluvio-aluvionar in Portuguese); it is also described in the literature but it is not yet incorporated in well sitting practice. This model is based on the hypothesis that reclilinear drainages can also be controlled by the folietion of the rock. Eventually, depending upon the degree of weathering, a through-shaped structure filled with sediments (alluvium and regolith) can be developed which can store and water can be produced from. Using severalfield case studies, this Thesis presents a thorough analysis ofthe two above cited models and proposes a new model. The analysis is based on an integrated methodological approach using geophysics and structural geology. Both land (Resitiviy and Ground Penetrating Radar- GPR) and aerogeophysical (magnetics and frequency domain eletromagnetics) surveys were used. Slructural analysis emphasized neolectonic aspects; in general, itwas found that fractures in the E-W direction are relatively open, as compared to fracturas inthe N-S direction, probably because E-W fractures were opened by the neotectonic stress regime in Northeastern Brazil, which is controlled by E-W compression and N-S extension. The riacho-fenda model is valid where drainages are controlled by fractures. The degree of fracturing and associated weathering dictale the hydrogeological potential of the structure. Field work in structural analogues reveals that subvertical fractures show consistent directions both in outcrop and aerophotograph scales. Geophysical surveys reveal subvertical conductive anomalies associated to the fracture network controlling the drainage; one of the borders of the conductive anomaly usually coincide wih the drainage. An aspect of particular importance to the validation of fracture control are the possible presence of relalively deep conductive anomalies wihoul continuation or propagalion to the surface. The conductive nature of lhe anomaly is due to the presence of wealhered rock and sedirnenls (alluvium and/or regolilh) storing ground waler which occur associated to the fracture network. Magnetic surveys are not very sensisnive to these structures.lf soil or covering sedirnents are resislive (> 100 Ohm.m), GPR can ba used to image precisely lhe fracture network. A major limialion of riacho-fenda model, revealed by GPR images, is associated to the fact thal subhorizontal fractures do play a very important role in connecting the fracture network, besides connect shallow recharge zones to relalively deep subvertical frecture zones. Iffractures play just a secondary control on the drainage, however, r/acho-fenda model may have a very limiled validny; in these cases, large portions oflhe drainage do nol coincide wilh frectures and mosl oflhewells localed in lhe drainage surrounding would resull dry. Usually, a secondary conlrol on lhe drainage by Ihefraclure networkcan be revealed only wilh detailed geophysical survey. The calha elClv1o-aluvlonarmodel is valid where drainages are conlrolled by folialion. The degree 01 wealhering 01 lhe lolialion planes dictales lhe hydrogeological polenlial 01 lhe slruclure. Outcrop analysis reveals Ihal lolialion and drainage direclions are parallel and Ihal no Iraclures, orfraclures wilh diflerent directions 01 lhe drainage direclion occur. Geophysical surveys reveal conduclive anomalies in a slab lorm associaled 10 lhe Ihrough 01 lhe wealhered rock and sedimenls (alluvium and/or regolith). Magnelic surveys can ofler a very good conlrol on lolialion direclion. An importanl aspect 10 validale lolialion conlrol are lhe presence 01 conductive anomalies showing shallow and deep portions area which are linked. Illhere is an exlensive soil cover, r/acho-fenda and calha eIClv1o-aluv/onar conlrols can be easily misinlerpreled in lhe absence 01 geophysical conlrol. Certainly, Ihis lacl could explain at leasl a part of lhe failure index in well sitting. The model wealhering sack (bolsllo de Intempertsmo in Portuguese) is proposed to explain cases where a very inlensive wealhering occur over lhe crystalline rock so Ihal a secondary inlerslilial porosity is crealed. The waler is Ihen stored in lhe porous of lhe regolilh in a similar mannerlo sedimentary rocks. A possible example ofthis model was delecled by using land geophysical survey where a relalivelyvery deep isolaled conduclive anomaly, in a slab form, was delected. Iflhis structure does store ground waler, certainly Ihere must be a link 01 lhe deep slructure wilh lhe surface in orderlo provide walerfeeding. This model mighl explain anomalous waler yields as greal as 50 m³/h Ihalsomelimescan occur in crystalline rocks in Northeaslern Brazil

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work we have investigated some aspects of the two-dimensional flow of a viscous Newtonian fluid through a disordered porous medium modeled by a random fractal system similar to the Sierpinski carpet. This fractal is formed by obstacles of various sizes, whose distribution function follows a power law. They are randomly disposed in a rectangular channel. The velocity field and other details of fluid dynamics are obtained by solving numerically of the Navier-Stokes and continuity equations at the pore level, where occurs actually the flow of fluids in porous media. The results of numerical simulations allowed us to analyze the distribution of shear stresses developed in the solid-fluid interfaces, and find algebraic relations between the viscous forces or of friction with the geometric parameters of the model, including its fractal dimension. Based on the numerical results, we proposed scaling relations involving the relevant parameters of the phenomenon, allowing quantifying the fractions of these forces with respect to size classes of obstacles. Finally, it was also possible to make inferences about the fluctuations in the form of the distribution of viscous stresses developed on the surface of obstacles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The distribution of diagenetic alterations in Late Cenomanian siliciclastic reservoirs from Potiguar Basin was influenced by the stratigraphic framework and the depositional system. Seismic sections and geophysical logs of two wells drilled in the SW portion of the mentioned basin above register regional stratigraphic surfaces representing maximum floods related to a transgressive event. The sequential analysis of 80 m of drill core (~450 m deep) recognized nine depositional facies with an upwards granodecrescent standard piling that limits cycles with an erosional conglomeratic base (lag) overlain by intercalations of medium to very fine sandstones showing cross bedding (channel, planar and low angled) and horizontal bedding (plane-parallel , wave and flaser). The top of the cycles is marked by the deposition of pelites and the development of paleosoils and lagoons. The correlation of genetically related facies reveals associations of channel fillings, crevasse, and flood plains deposited in a transgressive system. Detailed descriptions of seventy nine thin sections aided by MEV-EBSD/EDS, DRX and stable isotope analyses in sandstones revealed an arcosian composition and complex textural arrays with abundant smectite fringes continuously covering primary components, mechanically infiltrated cuticles and moldic and intragrain pores. K-feldspar epitaxial overgrowth covers microcline and orthoclase grains before any other phase. Abundant pseudomatrix due to the compactation of mud intraclasts concentrate along the stratification planes, locally replaced by macrocristalline calcite and microcrystalline and framboidal pyrite. Kaolinite (booklets and vermicular), microcrystalline smectite, microcrystalline titanium minerals and pyrite replace the primary components. The intergrain porosity prevails over the moldic, intragrain and contraction porosities. The pores are poorly connected due to the presence of intergranular smectite, k-feldspar overgrowth, infiltrated mud and pseudomatrix. The sandstones were subjected to eodiagenetic conditions next to the surface and shallow burial mesodiagenetic conditions. The diagenetic alterations reduced the porosity and the permeability mainly due to the precipitation of smectite fringes, compactation of mud intraclasts onto the pseudomatrix and cementing by poikilotopic calcite characterizing different reservoir petrofacies. These diagenetic products acted as barriers and detours to the flow of fluids thus reducing the quality of the reservoir.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The constant necessity for new sources of renewable energy is increasingly promoting the increase of investments in this area. Among other sources, the wind power has been becoming prominent. It is important to promote the search for the improvement of the technologies involved in the topologies of the wind turbines, seeking for alternatives which enhance the gotten performance, despite the irregularity of the wind speed. This study presents a new system for speed control, in this case applied to the wind turbines - the Electromagnetic Frequency Regulator (EFR). One of the most used devices in some topologies is the mechanical gearboxes which, along with a short service life, often represent sources of noise and defects. The EFR does not need these transmission boxes, representing a technological advancement, using for that an adapted induction machine, in which the stator becomes mobile, supportive to the axis of the turbine. In the topology used in this study, the EFR also allows us to leave out the usage of the eletronic converters to establish the coupling between the generator and the electrical grid. It also the reason why it provides the possibility of obtaining the generation in alternating current, with constant voltage and frequency, where there is no electrical grid. Responsable for the mechanical speed control of the generator, the EFR can be useful in other transmission systems in which the mechanical speed control output is the objective. In addition, the EFR operates through the combination of two inputs, a mechanical and other electrical. It multiplies the possibilities of application because it is able to synergistic coupling between different arrays of energy, and, for such reasons, it enables the various sources of energy involved to be uncoupled from the network, being the synchronous generator responsible for the system connection with the electrical grid, simplifying the control strategies on the power injected in it. Experimental and simulation results are presented through this study, about a wind turbine, validating the proposal related to the efficience in the speed control of the system for different wind conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electrical disturbances such as voltage sags, interruptions and voltage unbalances might cause serious problems for the end-user and for the companies of generation and transmission of energy. Few years ago, those companies have been using methods and equipments of protection to avoid the disturbances’ presence or to mitigate their effects on the power system. Disturbances generators are used to analyse the behavior of electrical and electronic equipments affected by disturbances. The analysis of those failures allows the development of appropriated protection equipments. In this paper, the development of a disturbances generator based on power converters is presented. The disturbance generator developed is able to generate some symmetrical disturbances, such as: voltage sags, voltage swells and harmonic distortion. The control strategy used in the disturbance generator is based on discrete and repetitive control. The steps of the design of the control and of the filter used for reducing harmonic in the output, are detailed in the text. Are presented the obtained results on computational simulations and the obtained results on laboratory tests.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Generation systems, using renewable sources, are becoming increasingly popular due to the need for increased use of electricity. Currently, renewables sources have a role to cooperate with conventional generation, due to the system limitation in delivering the required power, the need for reduction of unwanted effects from sources that use fossil fuels (pollution) and the difficulty of building new transmission and/or distribution lines. This cooperation takes place through distributed generation. Therefore, this work proposes a control strategy for the interconnection of a PV (Photovoltaic) system generation distributed with a three-phase power grid through a connection filter the type LCL. The compensation of power quality at point of common coupling (PCC) is performed ensuring that the mains supply or consume only active power and that his currents have low distorcion. Unlike traditional techniques which require schemes for harmonic detection, the technique performs the harmonic compensation without the use of this schemes, controlling the output currents of the system in an indirect way. So that there is effective control of the DC (Direct Current) bus voltage is used the robust controller mode dual DSMPI (Dual-Sliding Mode-Proportional Integral), that behaves as a sliding mode controller SM-PI (Sliding Mode-Proportional Integral) during the transition and like a conventional PI (Proportional Integral) in the steady-state. For control of current is used to repetitive control strategy, which are used double sequence controllers (DSC) tuned to the fundamental component, the fifth and seventh harmonic. The output phase current are aligned with the phase angle of the utility voltage vector obtained from the use of a SRF-PLL (Synchronous Reference Frame Phase-Locked-Loop). In order to obtain the maximum power from the PV array is used a MPPT (Maximum Power Point Tracking) algorithm without the need for adding sensors. Experimental results are presented to demonstrate the effectiveness of the proposed control system.