60 resultados para Ventilação Não Invasiva


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Experiments were performed to study the effect of surface properties of a vertical channel heated by a source of thermal radiation to induce air flow through convection. Two channels (solar chimney prototype) were built with glass plates, forming a structure of truncated pyramidal geometry. We considered two surface finishes: transparent and opaque. Each stack was mounted on a base of thermal energy absorber with a central opening for passage of air, and subjected to heating by a radiant source comprises a bank of incandescent bulbs and were performed field tests. Thermocouples were fixed on the bases and on the walls of chimneys and then connected to a data acquisition system in computer. The air flow within the chimney, the speed and temperature were measured using a hot wire anemometer. Five experiments were performed for each stack in which convective flows were recorded with values ranging from 17 m³ / h and 22 m³ / h and air flow velocities ranging from 0.38 m / s and 0.56 m / s for the laboratory tests and air velocities between 0.6 m/s and 1.1m/s and convective airflows between 650 m³/h and 1150 m³/h for the field tests. The test data were compared to those obtained by semi-empirical equations, which are valid for air flow induced into channels and simulated data from 1st Thermodynamics equation. It was found that the chimney with transparent walls induced more intense convective flows than the chimney with matte finish. Based on the results obtained can be proposed for the implementation of prototype to exhaust fumes, mists, gases, vapors, mists and dusts in industrial environments, to help promote ventilation and air renewal in built environments and for drying materials, fruits and seeds

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Obesity impairment to the pulmonary function related to the magnitude of adiposity and is associated with excessive daytime sleepiness (EDS) and snoring, among others symptoms of respiratory disorders related to sleep. It is possible that obese individuals with excessive daytime sleepiness may make changes in lung function on spirometry monitored during the day as a consequence of fragmented sleep or episodes of nocturnal hypoventilation that cause respiratory and changes that can persist throughout the day. The combination of these findings alone sleepiness observed by subjective scales with pulmonary function in obese patients is unknown. Objective: To assess the influence of EDS and snoring on pulmonary function in morbidly obese and distinguish between different anthropometric markers, the snoring and sleepiness which the best predictors of spirometric function and respiratory muscle strength and endurance of these patients. Methods: We evaluated 40 morbidly obese markers on the anthropometric, spirometric respiratory variables, maximal inspiratory and expiratory pressures (MIP and MEP) and maximal voluntary ventilation (MVV) and the measured excessive daytime sleepiness (the Epworth sleepiness scale) and snoring (snoring scale of Stanford). The data were treated when the differences between the groups of obese patients with and without sleepiness, whereas the anthropometric variables, respiratory and snoring. Pearson's correlation was performed, and multiple regression analysis assessed the predictors of pulmonary function. For this we used the software SPSS 15.0 for windows and p <0.05. Results: 39 obese patients were included (28 women), age 36.92+11.97y, body mass index (BMI) 49.3+5.1kg/m², waist-hip ratio (WHR) 0.96+0.07 and neck circumference (NC) 44.1+4.2 cm. Spirometric values and respiratory pressures were up 80% of predicted values, except for endurance (MVV <80%). Obese with EDS have lower tidal volume. Positive correlation was observed between BMI and EDS, EDS and NC and between snoring and BMI, and negative correlation between EDS and tidal volume (TV), and between snoring and snoring FVC and FEV1. In linear regression the best predictor of pulmonary function was snoring, followed by NC. NC has more obese with higher strength (MEP, p = 0.031) and endurance (MVV p = 0.018) respiratory muscle. Conclusion: Obese with EDS tend to have lower TV. In addition, snoring and NC can better predict pulmonary function in obese when compared with other anthropometric markers or EDS. Obese patients with higher NC tend to have greater capacity for overall strength of respiratory muscles, but may have low muscle endurance

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The strength of respiratory muscle are frequently assessed by maximal inspiratory and expiratory pressure, however, the maneuvers to assess PImax and PEmax are difficult for many patients. The sniff nasal inspiratory pressure (SNIP) is a simple and noninvasive technique use to assess inspiratory muscles strength. Reference values have been previous established for SNIP in adults but no previous studies have provided reference values for SNIP in adult Brazilian population. The main objective of this study were propose reference values of SNIP for Brazilian population through establishment of relationship between anthropometric measurements, physical activity profile and SNIP and at the same time compare the values obtained with reference values previously published. We studied 117 subjects (59 male and 58 female) distributed in different age grouped 20-80 years old. The results showed on significant positive relationship between SNIP and height and negative correlation with age (p<0.05). In the multiple linear regression analysis only age continued to have an independent predictive role for the two dependent variables that correlated with SNIP. The values of SNIP found in Brazilian population were higher when compared with predict values of previous studies. The results of this study provide reference equations of SNIP for health Brazilian population from 20 to 80 years old

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Obesity may affect the respiratory system, causing changes in respiratory function and in the pulmonary volumes and flows. Objectives: To evaluate the influence of obesity in the movement of thoracoabdominal complex at rest and during maximal voluntary ventilation (MVV), and the contribution between the different compartments of this complex and the volume changes of chest wall between obese and non-obese patients. Materials and Methods: We studied 16 patients divided into two groups: the obese group (n = 8) and group non-obese (n = 8). The two groups were homogeneous in terms of spirometric characteristics (FVC mean: 4.97 ± 0.6 L - 92.91 ± 10.17% predicted, and 4.52 ± 0.6 L - 93.59 ± 8.05%), age 25.6 ± 5.0 and 26.8 ± 4.9 years, in non-obese and obese respectively. BMI was 24.93 ± 3.0 and 39.18 ± 4.3 kg/m2 in the groups investigated. All subjects performed breathing calm and slow and maneuver MVV, during registration for optoelectronic plethysmography. Statistical analysis: we used the unpaired t test and Mann-Whitney. Results: Obese individuals had a lower percentage contribution of the rib cage abdominal (RCa) during breathing at rest and VVM. The variation of end expiratory (EELV) and end inspiratory (EILV) lung volumes were lower in obese subjects. It has been found asynchrony and higher distortion between compartments of thoracoabdominal complex in obese subjects when compared to non-obese. Conclusions: Central obesity impairs the ventilation lung, reducing to adaptation efforts and increasing the ventilatory work

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O Acidente Vascular Cerebral (AVC) é uma síndrome clínica caracterizada por uma perturbação focal da função cerebral. Geralmente ocasiona quadro de disfunção motora acompanhada de prejuízo da função respiratória. Tendo em vista tal quadro e suas possíveis repercussões, a fisioterapia respiratória tem sido amplamente requisitada com o intuito reverter ou minimizar as complicações. Dentre os recursos utilizados para este fim, os espirômetros de incentivo são utilizados com o objetivo de restaurar os volumes pulmonares, modificando o padrão respiratório e de ventilação pulmonar, prevenindo a incidência das complicações pulmonares. O objetivo do presente estudo foi comparar o desempenho na realização da espirometria de incentivo volume-orientada (EI) e seus efeitos agudos sobre os volumes pulmonares em pacientes após AVC e sujeitos saudáveis. Foram selecionados 40 voluntários, de ambos os gêneros, divididos em grupo experimental (GE), composto por 20 pacientes após AVC e grupo controle (GC) composto por 20 sujeitos saudáveis, pareados quanto à idade, gênero e Índice de Massa Corpórea (IMC). A coleta dos dados foi realizada em duas etapas: (1) Avaliação cognitiva e neurofuncional (Mini Exame do Estado Mental, National Institute Stroke Scale, Medida de Independência Funcional, teste de desempenho da aprendizagem) (2) Avaliação Respiratória (espirometria, manovacuometria e cinemática tóraco-abdominal, através da Pletismografia Opto-eletrônica). A análise estatística foi realizada através do software Graphpad Prism 4.0, em que foram utilizados os testes t Student e ANOVA two-way para comparação intergrupos e adotado nível de significância de 5%. Os resultados mostraram que os pacientes apresentam desempenho inferior na aprendizagem da espirometria de incentivo, com uma média de erros maior 2,95 ± 1,39, quando comparados aos sujeitos saudáveis, 1,15 ± 0,98. Em relação à prática observacional utilizada não foi encontrada diferença entre a aprendizagem através do vídeo ou do terapeuta. Em relação aos efeitos agudos da espirometria de incentivo volume-orientada, os pacientes após AVC apresentaram valores de volume corrente 24,7%, 18% e 14,7% inferiores quando comparados aos sujeitos saudáveis nos momentos pré-EI, EI e pós-EI, porém a espirometria de incentivo induziu incrementos de volume similares em ambos os grupos estudados, com 75, 3% para os pacientes e 73,3% para os sujeitos saudáveis. A espirometria de incentivo promove ganhos significativos no volume corrente da parede torácica, tanto em pacientes acometidos por AVC como em sujeitos saudáveis, no entanto o desempenho da aprendizagem é inferior para os pacientes, para ambas as práticas com vídeo ou terapeuta

Relevância:

10.00% 10.00%

Publicador:

Resumo:

obesity affects rightly functional capacity diminishing the cardiovascular system efficiency and oxygen uptake (VO2). Field tests, such as, Incremental Shuttle Walking Test (ISWT) and Six Minute Walk Test (6MWT) has been employed as alternative of Cardiopulmonary Exercise Test (CPX), to functional assessing for conditions which transport of oxygen to peripheral is diminished. Nevertheless, the knowing about metabolic variables response in real time and it comparing among different maximal and submaximal tests in obese is absent. Aim: to compare cardiopulmonary, metabolic response during CPX, ISWT and 6MWT and to analyse it influence of adiposity markers in obese. Material e Method: crosssectional, prospective study. Obese included if: (BMI>30Kg/m2; FVC>80%), were assessed as clinical, anthropometric (BMI, body adiposity index-BAI, waist-WC, hip- HC and neck-NC circumferences) and spirometry (forced vital capacity-FVC, Forced expiratory volume-1°second-FEV1, maximal voluntary ventilation-MVV) variables. Obese performed the sequence of tests: CPX, ISWT and 6MWT. Throughout tests was assessed breath-by-breath by telemetry system (Cortex-Biophysik-Metamax3B) variables; oxygen uptake on peak of activity (VO2peak); carbon dioxide production (VCO2); Volume Expiratory (VE); ventilatory equivalents for VO2 (VE/VO2) and CO2 (VE/VCO2); respiratory exchange rate (RER) and perceived effort-Borg6-20). Results: 15 obese (10women) 39.4+10.1years, normal spirometry (%CVF=93.7+9.7) finished all test. They have BMI (43.5+6.6kg/m2) and different as %adiposity (BAI=50.0+10.5% and 48.8+16.9% respectively women and men). Difference of VO2ml/kg/min and %VO2 were finding between CPX (18.6+4.0) and 6MWT (13.2+2.5) but not between ISWT (15.4+2.9). Agreement was found for ISWT and CPX on VO2Peak (3.2ml/kg/min; 95%; IC-3.0 9.4) and %VO2 (16.4%). VCO2(l/min) confirms similarity in production for CPX (2.3+1.0) and ISWT (1.7+0.7) and difference for 6MWT (1.4+0.6). WC explains more the response of CPX and ISWT than other adiposity markers. Adiposity diminishes 3.2% duration of CPX. Conclusion: ISWT promotes similar metabolic and cardiovascular response than CPX in obese. It suggesting that ISWT could be useful and reliable to assess oxygen uptake and functional capacity in obese

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dental caries consists in a multifactorial and dynamic process. The knowledge of the ionic interactions among dental tissues and dental biofilm make possible its understanding as a process that can be stopped. Recently, the use of sealants have lost its function as preventive agent and passed to be argued as a possible therapeutical agent. This happens by hindering the substratum flow to the lesion inner and, therefore, controls the advance of the process. This study aimed to evaluate glass ionomer cement as a not invasive technique of treatment in occlusal caries without clinical cavitation, but with dentinal involvement. The research was accomplished using a controlled clinical trial with two groups (experimental and control) in 38 subjects (8-18 years) with 51 molars. The teeth of the experimental group were sealed with glass ionomer cement (Vidrion-R, S.S.White, Juiz de Fora, Brazil) and the molars control did not suffer intervention. The experimental group was followed by a year and the control by 8 months due the progression of the carious injury. Both groups were reevaluated to each 4 months with the use of clinical, radiographic and laser fluorescence (DIAGNOdent®) examination. The analysis of the clinical evaluation did not observe a significant difference between experimental and control groups. However, analysis with radiographic and laser fluorescence (DIAGNOdent®) examination observed a significant difference (p> 0,05) between groups, demonstrating a wors condition to the group without intervention. The results suggest that glass ionomer cement as sealant can be efficient to paralyze dentinal caries without clinical cavitation

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work we used chemometric tools to classify and quantify the protein content in samples of milk powder. We applied the NIR diffuse reflectance spectroscopy combined with multivariate techniques. First, we carried out an exploratory method of samples by principal component analysis (PCA), then the classification of independent modeling of class analogy (SIMCA). Thus it became possible to classify the samples that were grouped by similarities in their composition. Finally, the techniques of partial least squares regression (PLS) and principal components regression (PCR) allowed the quantification of protein content in samples of milk powder, compared with the Kjeldahl reference method. A total of 53 samples of milk powder sold in the metropolitan areas of Natal, Salvador and Rio de Janeiro were acquired for analysis, in which after pre-treatment data, there were four models, which were employed for classification and quantification of samples. The methods employed after being assessed and validated showed good performance, good accuracy and reliability of the results, showing that the NIR technique can be a non invasive technique, since it produces no waste and saves time in analyzing the samples

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The World Wide Web has been consolidated over the last years as a standard platform to provide software systems in the Internet. Nowadays, a great variety of user applications are available on the Web, varying from corporate applications to the banking domain, or from electronic commerce to the governmental domain. Given the quantity of information available and the quantity of users dealing with their services, many Web systems have sought to present recommendations of use as part of their functionalities, in order to let the users to have a better usage of the services available, based on their profile, history navigation and system use. In this context, this dissertation proposes the development of an agent-based framework that offers recommendations for users of Web systems. It involves the conception, design and implementation of an object-oriented framework. The framework agents can be plugged or unplugged in a non-invasive way in existing Web applications using aspect-oriented techniques. The framework is evaluated through its instantiation to three different Web systems

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Because the penetration depth of Ground Penetrating Radar (GPR) signals is very limited in high conductive soils, the usefullness of this method in tropical regions is not yet completly known. The main objective of this researh is to test the usefullness of the method in Brazil. Two typical problems where GPR has been used in Europe and North American were choosed for this test: the first one is to characterize the internal structures of a sand body and the second problem is the localization of old buried pipes lines. The first test was done near the city of São Bento do Norte, in the northern coast of Rio Grande do Norte state, NE Brazil. In this region, there is a sand dune that is migrating very fast in the direction of adjacent settling areas. To characterize the internal structure of the dune and its relationship to the prevailing wind direction, as a preliminary step to understand the dune migration, GPR profiles using the 400 MHz frequency were performed in E-W, N-S, NE-SW, and SE-NW directions over the sand dune intersecting at the top of the dune. The practical resolution of the GPR data is around 30 cm; this was sufficient to distinguish individual foresets inside the dune. After applying the elevation correction to the data, we identified that dips of bedding structures are smallest for the N-S profile, which is perpendicular to the dominant wind direction, largest for the E-W profile, and intermediate for the SW-NE and SE-NW profiles. Foresets in the E-W profile dip with angles varying from 2 to 6 degrees. In the E-W profile, the water table and a horizontal truncation interface separating two generations of dunes were identified, as well as an abrupt directional change in the foreset patterns associated to a lateral contact between two dune generations, the older one extending to the west. The used high frequency of 400 Mhz does not allow a penetration deep enough to map completely these internal contacts. The second test was done near Estreito, a small town near Carnaúbais city, also in Rio Grande do Norte state. In this locality, there are several old pipe lines buried in area covered by plantations where digging should be minimized. Several GPR profiles using the 400 and 200 MHz frequency were performed trying to intercept perpendicularly the possible pipe lines. Because of the high conductivity of the soil, the raw original data can hardly be use to identify the pipe lines. However, after an adequate processing over the 200 MHz profiles, six pipe lines were identified. As a global result of the tests, GPR can be very usefull if the conductivity of the ground is low or, in the case of medium conductivities of the soils, if adequate processing is performed

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The current paper aims to check the environmental population perception of the two east side districts of Natal / RN (Rocas and Petrópolis) on its afforestation. The issues related to the environmental perception and afforestation of cities are gaining prominence in the many different areas of knowledge. However, the approaches and methodologies that are following an analytical perspective that by the rule aimed an policy of spatial planning not always responds to the aspirations and needs of the urban population. The research has been consisted of a preliminary survey, collecting data through the representative population of the neighborhoods in Petrópolis and Rocas, which were applied 210 forms (with the households), 130 in the neighborhood of Rocas and 80 in Petrópolis, which corresponds to 5% of the total households of the two districts, using as indicators, among many others, the income, the level of education and the environmental characteristics of the neighborhood. Through analysis sample was possible to verify that Petrópolis neighborhood that, 68% of interviewee believes their lives in the neighborhood where good and only 2% consider bad, in Rocas neighborhood, 57% considered life in his neighborhood good and only 5% consider bad. When asked about the main characteristics that remind the neighborhood Petrópolis, 90% of residents mentioned that one of its main advantages are the means of transport available, followed by 82% who quoted the ventilation as one of the main benefits of the neighborhood. In Rocas neighborhood, items mentioned by residents, were the ventilation with 47% of all interviewee and 32% said that peace is one of the most positive point of the neighborhood. From the description of some of the environmental needs of the neighborhoods Petrópolis and Rocas, it is possible to infer that environmental issues in general, and afforestation are always present in the speech of the residents, even indirect way, it shows that regardless of the education degree or the income, environmental quality is present as one of the basic needs of urban areas with implications both in the personal and social life as of its inhabitants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução: a avaliação da pressão inspiratória nasal (SNIP) é considerada uma manobra complementar da Pressão Inspiratória Máxima estática (PImax) em várias condições clínicas, porém não há relatos na obesidade. Por outro lado, a obesidade tem um importante impacto nos músculos respiratórios especialmente com maiores gordura abdominal o que provavelmente pode ser detectado na avaliação da SNIP que mensura mais precisamente a pressão diafragmática. Objetivo: analisar em obesos a relação entre SNIP e variáveis respiratórias e marcadores de adiposidade. Material e Método: num estudo transversal um total de 92 obesos (38.3±10.2 anos) sem história de doença respiratória ou cardíaca diagnosticada. Foram avaliados na espirometria (capacidade vital forçada-CVF; volume expiratório forçado no primeiro segundo-VEF1; volume de reserva expiratório-VRE) e pressões respiratórias estática (PImax, PEmax e SNIP) e dinâmica (ventilação voluntária máxima-VVM). Sendo considerados os marcadores de adiposidade: índice de adiposidade corporal-IAC; índice de massa corporal-IMC e circunferências do quadril (CQ), cintura (CC) e pescoço (CP). Resultados: 65 obesos mórbidos (IMC=50.8±8.1Kg/m2) e 27 obesos não mórbidos (IMC=35.6±2.7Kg/m2) foram homogêneos (p>0.05) na SNIP (99.1±24.5cmH2O, 87% do predito) e PImax (107.3±26.4cmH2O, 109% do predito). Existe correlação (r=0.5) entre SNIP e PImax somente no grupo de obesos mórbidos. De acordo com as correlações houve associação entre variáveis respiratórias (CVF r=0.48; VEF1 r=0.54; e VVM r=0.54), valores antropométricos (idade r=-0.44) e SNIP somente para os obesos mórbidos. Esses achados foram certificados quando também comparados a quantidade de gordura ao redor do pescoço (CP≥43cm). O modelo de regressão linear stepwise mostrou que a VVM parece ser o melhor preditor para explicar a SNIP nos obesos mórbidos. Nestes obesos a SNIP foi levemente mais baixa (87%predito) que os valores esperados para indivíduos brasileiros saudáveis. Conclusão: em obesos mórbidos a SNIP é moderadamente relacionada a PImax. A SNIP parece ser mais relacionada a VVM que à marcadores de adiposidade.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the intention of studying and developing the design process based on a specific methodology, the object of this work is to present the design of a gated condominium community in Natal based on the application of principles of shape grammar, used in their design process. The shape grammar is a design method developed in the 1970s by George Stiny and James Gips. It is used for the analysis of the project as well as for its synthesis, with the goal of creating a "formal vocabulary" through mathematical and/or geometrical operations. Here, the methodology was used in the synthesis of the design process, through the relationship between formal subtractions and the houses’ architectural planning. As a result, five dwellings configurations were proposed, each one different from the other with respect to their shape and architectural programming, distributed in three twin groups, which are repeated until the final total of nine architectural volumes. In addition to studies of the condominium’s ventilation and the buildings’ shading simulations, studies of spatial flexibility and acoustic performance were also performed. The mapping of the design process, one of the specific objectives of the dissertation, was composed not only by the record of formal constraints (the preparation and application of rules), but also by physical, environmental, legal and sustainability aspects in relation to, on one hand, the optimization of the shading and passive ventilation for hot and humid climates, and, on the other hand, the modulation and rationalization of the construction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study addresses the environmental quality in therapeutic spaces for children's rehabilitation. The assumption that space is active and interfere in interpersonal relationships, highlights the importance of natural light to the hospital architecture, to foster the creation of environments that encourage and assist in the recovery of patients in the rehabilitation process. Therefore, interferes with health humanization through positive actions in the physiological and emotional effects of natural light, as facilitators of the health recovery process. In Brazil hospital openings systems projects are built exclusively to follow requirements of the local construction code which do not consider the landscape, but only ventilation and heat stroke; and the luminance levels are treated just as recommendations for artificial lighting. The National Policy for Healthcare Humanization presents the environmental comfort as a priority. However, it does not guidelines for achieving it. In this context this research aims to evaluate the lighting comfort in infant therapeutic areas from the professional satisfaction, in order to identify human preferences on the variables: technical and constructive aspects, relationship with the exterior, internal visual interface and quality elements. With this purpose it was adopted as research strategy the Post-Occupancy Evaluation (Technical Functional) through a multi method approach, which included a case study in the rehabilitation gym of Children Rehabilitation Center, at Natal, Rio Grande do Norte, and a reference study at SARAH Rehabilitation Center, Fortaleza Unit at Ceará, both in Brazil northeast. The results indicate that the definition of openings systems should consider external and internal factors to the building, as the natural landscape, the immediate surroundings and activities to be performed. The POE found out the preference of the professional visual privacy in detriment to other analyzed aspects. Thus, it is expected that this study can contribute to the discussion of luminous quality and generate inputs for future projects or renovations in the Children's Rehabilitation Centers, which should not be projected as hospitals

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Obesity shows changes in pulmonary function and respiratory mechanics, however, little is known regarding the prevalence of worsening respiratory function when considering the increase in central or peripheral adiposity or general obesity. Objectives: To analyze the association between anthropometric adiposity and decreased lung function in obese. Materials and Methods: Patients eligible for this study obese individuals (IMC≥30kg/m2) in pre-bariatric surgery and referred for Treatment Clinic of Obesity and Related Diseases, located at the University Hospital Onofre Lopes (HUOL), from October 2005 and July 2014. The evaluation included clinical information and measurement of anthropometric measures (body mass index (BMI), body fat index (BFI) and waist circumference (WC) and neck (NC)) and spirometric. The prevalence and analysis by Poisson regression was performed considering the following outcome variables: forced vital capacity (FVC), forced expiratory volume in one second (FEV1) and Maximum Voluntary Ventilation (MVV) and as predictor variables were considered: BMI, IAC, WC and NC and as control variables: age, gender, smoking history and comorbidities (diabetes mellitus, dyslipidemia and hypertension). Statistical analysis was performed using Statistical Package for Social Sciences software (SPSS - version 20.0). Results: We analyzed 384 individuals, 75% women, mean BMI: 46.6 (± 8.7) kg/m2, IAC: 49.26 (± 9.48)%, WC: 130.84 (± 16.23) cm and NC: 42.3 (± 4.6) cm. The higher prevalence of FVC and FEV1 <80% was observed in individuals with NC above 42 cm, followed those with a BMI above 45 kg/m2. Multivariate analysis using Poisson regression showed as risk factors associated with FVC <80%, the variables: NC above 42 cm (odds ratio (OR) 2.41) and BMI over 45Kg/m2 (OR 1.71 ). As for FEV1 <80% predicted, all predictor variables were associated, with the largest odds presented by the NC (3.40). MVVV was not associated with any studied varaible. Conclusion: Individuals with NC above 42 cm had higher prevalence of reduced lung function and the NC was the measure with the highest association with reduced lung function in obese.