42 resultados para Iluminação elétrica


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study consists in the structure elaboration and the ePoste project communicationprotocol, which is a system of monitoring by wireless communication with the aim tosensor and act with one or many public lighting points, and also the treatment of data todetect the activity in the sensors located on the posts. Previously the communication withsensors were made in locus and when data collect was necessary or the performance inthe devices, the operator had to move until the net place. Accordingly, the purpose has theconcern to increase the system dynamic, achieving the possible integrations with the systemsalready available to the lighting management. The same technology of communicationbetween the sensors are considerate, using the ZigBee protocol running on the meshnet, the communication with this net is made be internet through a gateway by GPRS,device with two basics functionalities, which bypass for data and the firmware update inthe sensor. This functionality test of data management is being tested; integrate way withlocal net of sensors and the internet data server operates. The protocol developed, besidesincorporating the ZigBee, that it is formation of framework in lower level, where definesbeginning, size and errors check, as well as the communication of sensor with the concentrator,which it is encapsulated in ZigBee; also the protocol of upper level, where thatit is the names, it was developed a platform of service to meet GET and POST requestsbeneath HTTP protocol, this service is implemented in the data server, which availablethe communication with the clients systems, in case, lighting management systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work deals with the specification and the implementation of a protocol for controlling communication between two programmable interface microcontrollers (PIC), using power line communication (PLC), making communication more secure and economically viable. The Protocol was implemented in C language, with reference to some protocols developed for automotive use. A circuit to test the communication between the PLC and the Protocol was also implemented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Synchronous machines, widely used in energy generation systems, require constant voltage and frequency to obtain good quality of energy. However, for large load variati- ons, it is difficult to maintain outputs on nominal values due to parametric uncertainties, nonlinearities and coupling among variables. Then, we propose to apply the Dual Mode Adaptive Robust Controller (DMARC) in the field flux control loop, replacing the tradi- tional PI controller. The DMARC links a Model Reference Adaptive Controller (MRAC) and a Variable Structure Model Reference Adaptive Controller (VS-MRAC), incorpora- ting transient performance advantages from VS-MRAC and steady state properties from MRAC. Moreover, simulation results are included to corroborate the theoretical studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Brazil, the National Agency of Electric Energy (ANEEL) represents the energy regulator. The rates review have been one of its main tasks, which establish a pricing practice at a level to cover the efficient operating costs and also the appropriate return of the distributors investments. The changes in the procedures to redefine the efficient costs and the several studies on the methodologies employed to regulate this segment denote the challenge faced by regulators about the best methodological strategy to be employed. In this context, this research aims to propose a benchmarking evaluation applied to the national regulation system in the establishment of efficient operating costs of electricity distribution utilities. The model is formulated to promote the electricity market development, partnering with government policies ant to society benefit. To conduct this research, an integration of Data Envelopment Analysis (DEA) with the Stochastic Frontier Analysis (SFA) is adopted in a three stages procedure to correct the efficiency in terms of environmental effects: (i) evaluation by means of DEA to measure operating costs slacks of the utilities, in which environmental variables are omitted; (ii) The slacks calculated in the first stage are regressed on a set of environmental variables by means of SFA and operating costs are adjusted to account the environmental impact and statistical noise effects; and, (iii) reassess the performance of the electric power distribution utilities by means of DEA. Based on this methodology it is possible to obtain a performance evaluation exclusively expressed in terms of management efficiency, in which the operating environment and statistical noise effects are controlled.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Generation systems, using renewable sources, are becoming increasingly popular due to the need for increased use of electricity. Currently, renewables sources have a role to cooperate with conventional generation, due to the system limitation in delivering the required power, the need for reduction of unwanted effects from sources that use fossil fuels (pollution) and the difficulty of building new transmission and/or distribution lines. This cooperation takes place through distributed generation. Therefore, this work proposes a control strategy for the interconnection of a PV (Photovoltaic) system generation distributed with a three-phase power grid through a connection filter the type LCL. The compensation of power quality at point of common coupling (PCC) is performed ensuring that the mains supply or consume only active power and that his currents have low distorcion. Unlike traditional techniques which require schemes for harmonic detection, the technique performs the harmonic compensation without the use of this schemes, controlling the output currents of the system in an indirect way. So that there is effective control of the DC (Direct Current) bus voltage is used the robust controller mode dual DSMPI (Dual-Sliding Mode-Proportional Integral), that behaves as a sliding mode controller SM-PI (Sliding Mode-Proportional Integral) during the transition and like a conventional PI (Proportional Integral) in the steady-state. For control of current is used to repetitive control strategy, which are used double sequence controllers (DSC) tuned to the fundamental component, the fifth and seventh harmonic. The output phase current are aligned with the phase angle of the utility voltage vector obtained from the use of a SRF-PLL (Synchronous Reference Frame Phase-Locked-Loop). In order to obtain the maximum power from the PV array is used a MPPT (Maximum Power Point Tracking) algorithm without the need for adding sensors. Experimental results are presented to demonstrate the effectiveness of the proposed control system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The key aspect limiting resolution in crosswell traveltime tomography is illumination, a well known result but not as well exemplified. Resolution in the 2D case is revisited using a simple geometric approach based on the angular aperture distribution and the Radon Transform properties. Analitically it is shown that if an interface has dips contained in the angular aperture limits in all points, it is correctly imaged in the tomogram. By inversion of synthetic data this result is confirmed and it is also evidenced that isolated artifacts might be present when the dip is near the illumination limit. In the inverse sense, however, if an interface is interpretable from a tomogram, even an aproximately horizontal interface, there is no guarantee that it corresponds to a true interface. Similarly, if a body is present in the interwell region it is diffusely imaged in the tomogram, but its interfaces - particularly vertical edges - can not be resolved and additional artifacts might be present. Again, in the inverse sense, there is no guarantee that an isolated anomaly corresponds to a true anomalous body because this anomaly can also be an artifact. Jointly, these results state the dilemma of ill-posed inverse problems: absence of guarantee of correspondence to the true distribution. The limitations due to illumination may not be solved by the use of mathematical constraints. It is shown that crosswell tomograms derived by the use of sparsity constraints, using both Discrete Cosine Transform and Daubechies bases, basically reproduces the same features seen in tomograms obtained with the classic smoothness constraint. Interpretation must be done always taking in consideration the a priori information and the particular limitations due to illumination. An example of interpreting a real data survey in this context is also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The key aspect limiting resolution in crosswell traveltime tomography is illumination, a well known result but not as well exemplified. Resolution in the 2D case is revisited using a simple geometric approach based on the angular aperture distribution and the Radon Transform properties. Analitically it is shown that if an interface has dips contained in the angular aperture limits in all points, it is correctly imaged in the tomogram. By inversion of synthetic data this result is confirmed and it is also evidenced that isolated artifacts might be present when the dip is near the illumination limit. In the inverse sense, however, if an interface is interpretable from a tomogram, even an aproximately horizontal interface, there is no guarantee that it corresponds to a true interface. Similarly, if a body is present in the interwell region it is diffusely imaged in the tomogram, but its interfaces - particularly vertical edges - can not be resolved and additional artifacts might be present. Again, in the inverse sense, there is no guarantee that an isolated anomaly corresponds to a true anomalous body because this anomaly can also be an artifact. Jointly, these results state the dilemma of ill-posed inverse problems: absence of guarantee of correspondence to the true distribution. The limitations due to illumination may not be solved by the use of mathematical constraints. It is shown that crosswell tomograms derived by the use of sparsity constraints, using both Discrete Cosine Transform and Daubechies bases, basically reproduces the same features seen in tomograms obtained with the classic smoothness constraint. Interpretation must be done always taking in consideration the a priori information and the particular limitations due to illumination. An example of interpreting a real data survey in this context is also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PEDRINI, Aldomar; SZOKOLAY, Steven. Recomendações para o desenvolvimento de uma ferramenta de suporte às primeiras decisões projetuais visando ao desempenho energético de edificações de escritório em clima quente. Ambiente Construído, Porto Alegre, v. 5, n. 1, p.39-54, jan./mar. 2005. Trimestral. Disponível em: . Acesso em: 04 out. 2010.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study is to assess the natural light of the classrooms sectors, at Universidade Federal do Rio Grande do Norte. It was applied the Post-Occupation Evaluation technique, by using questionnaires and brightness levels measurements inside the classrooms. In order to check the users satisfaction degree, it was initially done a general approach on the related aspects to natural light: their characteristics, availability, sources, opening systems and evaluating tools. It was also determined the necessary brightness levels for the activities development in the classroom and the Post-Occupation Evaluation technique used in the search analyses. Then, it was made the UFRN Campus` characterization; the models` definition which formed the data collection basis; the detailing of the procedures used in the research, the processing description and the data analysis. Subsequently, the results that clarify the issues raised were shown through quantitative and / or qualitative data analyses. This research notes a high level of satisfaction by the users, despite some problems such as the reflections occurrence on the board, the lack of uniformity and, occasionally, the brightness low levels

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research aims to investigate how the stage lighting can be articulated in the creation of theater actor process. To we reach this reflection, it is necessary to understand the space of the rehearsal room, where the actor works as a place where their function receives influences of other artists who are creating the spectacle.Collaborative processes are analyzed three Cia de Teatro Engenharia Cênica: Irremediável, 2007; Doralinas e Marias , 2009; O Menino Fotógrafo, 2011, aiming to understand the collaborative theater potentializes, the intersection and the exchange of experiences in the rehearsal room, collaborating actively for the training of persons involved in creating the show. The research proposes an investigation of how the creative process of stage lighting is gaining ground in the rehearsal room in the language of theater directing, showing mainly how is your "co-evolutionary" creation with the creative process of the actor

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work deals with the synthesis of materials with perovskite structure with the intention of using them as cathodes in fuel cells SOFC type. The perovskite type materials were obtained by chemical synthesis method, using gelatin as the substituent of citric acid and ethylene glycol, and polymerizing acting as chelating agent. The materials were characterized by X-ray diffraction, thermal analysis, spectroscopy Fourier transform infrared, scanning electron microscopy with EDS, surface area determination by the BET method and Term Reduction Program, TPR. The compounds were also characterized by electrical conductivity for the purpose of observing the possible application of this material as a cathode for fuel cells, solid oxide SOFC. The method using gelatin and polymerizing chelating agent for the preparation of materials with the perovskite structure allows the synthesis of crystalline materials and homogeneous. The results demonstrate that the route adopted to obtain materials were effective. The distorted perovskite structure have obtained the type orthorhombic and rhombohedral; important for fuel cell cathodes. The presentation material properties required of a candidate cathode materials for fuel cells. XRD analysis contacted by the distortion of the structures of the synthesized materials. The analyzes show that the electrical conductivity obtained materials have the potential to act as a cell to the cathode of solid oxide fuel, allowing to infer an order of values for the electrical conductivities of perovskites where LaFeO3 < LaNiO3 < LaNi0,5Fe0,5O3. It can be concluded that the activity of these perovskites is due to the presence of structural defects generated that depend on the method of synthesis and the subsequent heat treatment

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the increasing of demand for natural gas and the consequent growth of the pipeline networks, besides the importance of transport and transfer of oil products by pipeline, and when it comes to product quality and integrity of the pipeline there is an important role regarding to the monitoring internal corrosion of the pipe. This study aims to assess corrosion in three pipeline that operate with different products, using gravimetric techniques and electrical resistance. Chemical analysis of residues originated in the pipeline helps to identify the mechanism corrosive process. The internal monitoring of the corrosion in the pipelines was carried out between 2009 and 2010 using coupon weight loss and electrical resistance probe. Physico-chemical techniques of diffraction and fluorescence X-rays were used to characterize the products of corrosion of the pipelines. The corrosion rate by weight loss was analyzed for every pipeline, only those ones that has revealed corrosive attack were analyzed located corrosion rate. The corrosion potential was classified as low to pipeline gas and ranged from low to severe for oil pipelines and the pipeline derivatives. Corrosion products were identified as iron carbonate, iron oxide and iron sulfide