83 resultados para Correntes induzidas
Resumo:
The object of the present dissertation is to analyze the behavior of the public finances of the districts of the state of Rio Grande do Norte (RN), taking as reference a period fundamentally previous to the implementation of the Fiscal Responsibility Law LRF, comparatively to the first years, immediately after the advent of the mentioned institutional milestone. The central hypothesis of this study proposes that, from the institutions' viewpoint, the LRF sets securely consistent rules, in the orchestration of the behavior of the municipal revenues and expenses. These regulations, on the other hand, might be effective and reach the districts of the RN indiscriminately, apart from stabilizing tendencies and which are sustainable in the long run. In spite of this, the indicators calculated reveal that the districts researched show, during all the period under analysis, a diminished capacity of self-tax collection , and consequently, a high participation of the intergovernmental transfers in the composition of the current revenues. This behavior indicates that the goal of strengthening the municipal public finances, forecast in the LRF, tends to be only partially accomplished, due to the fiscal decentralism. The analysis and interpretation of the data are conducted from the literature of institutionalist orientation and in descriptive statistical tools applied to the municipal strata of the state of Rio Grande do Norte. Further on, it's used the econometrical method Pooled OLS, which demands the elimination of the municipal strata in order to allow the use of the model, in the attempt to strengthen and/or ratify the results of the research. Finally, the evidence reached in the dissertation show that the LRF brings better conditions to the potiguar municipal public finances, predominantly to the economically stronger districts; whereas the less dynamic municipal entities show rather divergent evidence, that is, their economies seem to be more oriented to a more pronounced state participation; therefore, it generates in the state of RN a certain antithesis in the results reached in the dissertation
Resumo:
This study - Biologist s formative speech about death. Nuances and metaphors from knowing that the subject of do not want to know - shows a marginal cognitive construction in scientific education from biologist - death. It considered as obvious that death is a theme that covers both the scientific education from biologist and the division of the subject, and concerns the splitting of the double life-death and the principles of inclusion and exclusion of the subject. Part of sensitive question: What is the epistemological weave who supports biologist's speech about death? It is constituted an object of study of the biologist s speech on death. It is advocated the thesis that: Death is an epistemological obstacle announcing for something always aims to escape from the perspective of knowledge, especially of scientific knowledge because, since it is understood as cognitive learning about the disruption of biological phenomenon life which is involved on weave of imaginary and symbolic constructions about the finiteness of life; it has constituted a metaphorical knowing - encouraged by the noisy silence - which does not allow to know in full, mobilizing hence subject in searching for transitional truths that reduce the ontological being-mortal anguish centered in subjective dimension involved in the act of knowing. From this movement of search that the object mental life after death wins a symbolic value that requires a real-looking multi-referential for the study of biology - life - and its implications: the finiteness of life, especially by moving the omnipotence of scientific objectivity expressed by signs and symbols that seek say the completeness of scientific knowledge-, signaling thus the existence of the dynamics of incompleteness implicit in subjectivity that supports knowledge relating to the double, life and death, and to the temporality of the existence of Homo sapiens sapiens, with the axis guiding the desire of the subject, do not want to know about death, implicit in the mechanisms objective-subjective founded by non-said of death is the epistemology of the existence of objective-subjective subject, whose core is the negation of death. The theoretical methodological knowing web is anchored in the multi-reference which favors a transit by theoretical current, as the Psychoanalysis, bachelardian philosophy, the epistemology of complexity, the Thanatology, the Social Psychology, and Etnocenology, and Understanding Interview. The unveiling of the study object from the analysis of oral speech of eleven biologists who serve in high school, from three main guiding: Death in the history of life,Death in biologist s academic education and, Conceptions about concepts
Resumo:
The purpose of this dissertation is to analyze the actual nature of the Scientific Journalism, studying the historical facts from these informations segment, their matters production and the news industries that work with these specific niche of the contemporary journalism. It is taken into account the educational potential of the specialized journalism and it is considered the communication as a transdiciplinary science. To get into this point it was elected as an analyze category the Reception it Mediation Studies specially the north-americans theories besides the utilization also of the reportage concept to identify how to establish the epistemological relations between Communication and Education. Among the objectives of this dissertation are the investigation of the scientific character of the journalism; the analysis of the theoretical currents of Pedagogy that are based on the theory of Social Communication, as for example the Total Language and the analysis of the industrial and technological characteristics of the most important scientific and cultural magazines of Brazil, Northeast and Natal
Resumo:
The present paper analyses matters about the assessment in the context of the school organization in cycles. The complexity that involves the assessment turns it into a difficult subject, since the evidence that the model supported by the traditional approach contributes to foil the fulfillment of new continuous and wide-ranging assessment practices, that are coherent with a view of learning as a process established in the student-teacher-knowledge interaction. This paper has as guidance the following questions: How did the introduction of the teaching organization in cycles happen in Fortaleza/ CE? How far are the teachers prepared to the introduction of the cycles system, specially in the way of thinking and practicing the assessment? What are the teacher s involvements with this project and with the continuous assessment in the cycles? What meanings do the teachers give to the assessment in this project? Therefore, were determined as objectives: to comprehend the meanings attributed to the learning assessment by the teachers in contact with the cycles in Fortaleza/CE; to identify assessment practices that are closer to a less qualifying perspective, more related to the students learning and to the educational intervention in order to improve this process. The methodological orientation chosen was based on the presuppositions of the comprehensible interview, with reference to the studies of the French sociologist Jean Claude Kaufmann, developed with 15 (fifteen) teachers of 15 (fifteen) schools of the state teaching system of Fortaleza/CE. It was considered, in the methodology, the word as a central fact in the consolidation of the object of study, what allows to conceive the teachers as active participants of this research and of the discussions about assessment. The analysis about the speeches in the interviews made possible to glimpse the meanings attributed to the learning assessment that are not related to the traditional paragon, in spite of the dilemma in which the participants of the research faced at the time of the introduction of the cycles in Fortaleza/CE. These meanings were created between the presence and the absence of the teachers knowledge that, in their way, interact with the changes caused by the obligation of the teaching organization in cycles, seeking a strategy of self-organization as a consequence of the search for new knowledge connected with the teaching
Resumo:
Ce projet présente dans son premier chapitre une étude historique-bibliographique basée sur la Pédagogie Freinet en France, ainsi que sa formation républicaine, ses courants politiques et idéologiques qui ont moulés l organisation sociale et éducationnelle de ce pays. Ce travail montre le rôle des courants de gauche dans ce processus, cela se reflète aussi sur le jeune Freinet. Les changements opérés dans la décennie de 1950 dans le système scolaire, dans le propre Mouvement Freinet et les ruptures qui ont eues à l intérieur de ce mouvement. Cela se termine avec les directions prises dans les dernières décennies, son arrivée au Brésil et les perspectives actuelles. Le deuxième chapitre aborde la reconstitution historique du Brésil dont sa phase coloniale et impériale. Les événements historiques de la IIIe, IVe et Ve République sont mis en relief avec ceux du Mouvement Freinet. La phase militaire imposée au Brésil et les luttes pour la reconquête de la démocratie. Il se termine avec les considérations sur la LDBEN 9394/96 et l implantation du Curso Normal Superior; un bref historique de la Pédagogie Freinet au Brésil, des thèmes importants travaillés dans le troisième chapitre. Dans ce chapitre une recherche qualitative est décrite basée dans l Etnographie Critique et Multiréférentiellel et aussi dans la Recherche-Action. Elle est développée auprès d un groupe de cinq professeurs des premières classes de l école primaire au collège, inscrites dans le Curso Normal Superior. Les données ont été obtenues à partir de rencontres régulières avec le groupe la médiation didactique , des entretiens, des questionnaires, des observations dans les salles de classe, du travail final du cours, nommé Mémorial de Formation. À travers l ensemble des données, on recherche les apports et l actualité d une proposition pédagogique historiquement firmée pour le développement de la praxis éducative
Resumo:
This work describes the study and the implementation of the vector speed control for a three-phase Bearingless induction machine with divided winding of 4 poles and 1,1 kW using the neural rotor flux estimation. The vector speed control operates together with the radial positioning controllers and with the winding currents controllers of the stator phases. For the radial positioning, the forces controlled by the internal machine magnetic fields are used. For the radial forces optimization , a special rotor winding with independent circuits which allows a low rotational torque influence was used. The neural flux estimation applied to the vector speed controls has the objective of compensating the parameter dependences of the conventional estimators in relation to the parameter machine s variations due to the temperature increases or due to the rotor magnetic saturation. The implemented control system allows a direct comparison between the respective responses of the speed and radial positioning controllers to the machine oriented by the neural rotor flux estimator in relation to the conventional flux estimator. All the system control is executed by a program developed in the ANSI C language. The DSP resources used by the system are: the Analog/Digital channels converters, the PWM outputs and the parallel and RS-232 serial interfaces, which are responsible, respectively, by the DSP programming and the data capture through the supervisory system
Resumo:
Conventional control strategies used in shunt active power filters (SAPF) employs real-time instantaneous harmonic detection schemes which is usually implements with digital filters. This increase the number of current sensors on the filter structure which results in high costs. Furthermore, these detection schemes introduce time delays which can deteriorate the harmonic compensation performance. Differently from the conventional control schemes, this paper proposes a non-standard control strategy which indirectly regulates the phase currents of the power mains. The reference currents of system are generated by the dc-link voltage controller and is based on the active power balance of SAPF system. The reference currents are aligned to the phase angle of the power mains voltage vector which is obtained by using a dq phase locked loop (PLL) system. The current control strategy is implemented by an adaptive pole placement control strategy integrated to a variable structure control scheme (VS-APPC). In the VS-APPC, the internal model principle (IMP) of reference currents is used for achieving the zero steady state tracking error of the power system currents. This forces the phase current of the system mains to be sinusoidal with low harmonics content. Moreover, the current controllers are implemented on the stationary reference frame to avoid transformations to the mains voltage vector reference coordinates. This proposed current control strategy enhance the performance of SAPF with fast transient response and robustness to parametric uncertainties. Experimental results are showing for determining the effectiveness of SAPF proposed control system
Resumo:
The usual programs for load flow calculation were in general developped aiming the simulation of electric energy transmission, subtransmission and distribution systems. However, the mathematical methods and algorithms used by the formulations were based, in majority, just on the characteristics of the transmittion systems, which were the main concern focus of engineers and researchers. Though, the physical characteristics of these systems are quite different from the distribution ones. In the transmission systems, the voltage levels are high and the lines are generally very long. These aspects contribute the capacitive and inductive effects that appear in the system to have a considerable influence in the values of the interest quantities, reason why they should be taken into consideration. Still in the transmission systems, the loads have a macro nature, as for example, cities, neiborhoods, or big industries. These loads are, generally, practically balanced, what reduces the necessity of utilization of three-phase methodology for the load flow calculation. Distribution systems, on the other hand, present different characteristics: the voltage levels are small in comparison to the transmission ones. This almost annul the capacitive effects of the lines. The loads are, in this case, transformers, in whose secondaries are connected small consumers, in a sort of times, mono-phase ones, so that the probability of finding an unbalanced circuit is high. This way, the utilization of three-phase methodologies assumes an important dimension. Besides, equipments like voltage regulators, that use simultaneously the concepts of phase and line voltage in their functioning, need a three-phase methodology, in order to allow the simulation of their real behavior. For the exposed reasons, initially was developped, in the scope of this work, a method for three-phase load flow calculation in order to simulate the steady-state behaviour of distribution systems. Aiming to achieve this goal, the Power Summation Algorithm was used, as a base for developping the three phase method. This algorithm was already widely tested and approved by researchers and engineers in the simulation of radial electric energy distribution systems, mainly for single-phase representation. By our formulation, lines are modeled in three-phase circuits, considering the magnetic coupling between the phases; but the earth effect is considered through the Carson reduction. Its important to point out that, in spite of the loads being normally connected to the transformers secondaries, was considered the hypothesis of existence of star or delta loads connected to the primary circuit. To perform the simulation of voltage regulators, a new model was utilized, allowing the simulation of various types of configurations, according to their real functioning. Finally, was considered the possibility of representation of switches with current measuring in various points of the feeder. The loads are adjusted during the iteractive process, in order to match the current in each switch, converging to the measured value specified by the input data. In a second stage of the work, sensibility parameters were derived taking as base the described load flow, with the objective of suporting further optimization processes. This parameters are found by calculating of the partial derivatives of a variable in respect to another, in general, voltages, losses and reactive powers. After describing the calculation of the sensibility parameters, the Gradient Method was presented, using these parameters to optimize an objective function, that will be defined for each type of study. The first one refers to the reduction of technical losses in a medium voltage feeder, through the installation of capacitor banks; the second one refers to the problem of correction of voltage profile, through the instalation of capacitor banks or voltage regulators. In case of the losses reduction will be considered, as objective function, the sum of the losses in all the parts of the system. To the correction of the voltage profile, the objective function will be the sum of the square voltage deviations in each node, in respect to the rated voltage. In the end of the work, results of application of the described methods in some feeders are presented, aiming to give insight about their performance and acuity
Resumo:
This work describes the study and the implementation of the speed control for a three-phase induction motor of 1,1 kW and 4 poles using the neural rotor flux estimation. The vector speed control operates together with the winding currents controller of the stator phasis. The neural flux estimation applied to the vector speed controls has the objective of compensating the parameter dependences of the conventional estimators in relation to the parameter machine s variations due to the temperature increases or due to the rotor magnetic saturation. The implemented control system allows a direct comparison between the respective responses of the speed controls to the machine oriented by the neural rotor flux estimator in relation to the conventional flux estimator. All the system control is executed by a program developed in the ANSI C language. The main DSP recources used by the system are, respectively, the Analog/Digital channels converters, the PWM outputs and the parallel and RS-232 serial interfaces, which are responsible, respectively, by the DSP programming and the data capture through the supervisory system
Resumo:
The reconfiguration of a distribution network is a change in its topology, aiming to provide specific operation conditions of the network, by changing the status of its switches. It can be performed regardless of any system anomaly. The service restoration is a particular case of reconfiguration and should be performed whenever there is a network failure or whenever one or more sections of a feeder have been taken out of service for maintenance. In such cases, loads that are supplied through lines sections that are downstream of portions removed for maintenance may be supplied by the closing of switches to the others feeders. By classical methods of reconfiguration, several switches may be required beyond those used to perform the restoration service. This includes switching feeders in the same substation or for substations that do not have any direct connection to the faulted feeder. These operations can cause discomfort, losses and dissatisfaction among consumers, as well as a negative reputation for the energy company. The purpose of this thesis is to develop a heuristic for reconfiguration of a distribution network, upon the occurrence of a failure in this network, making the switching only for feeders directly involved in this specific failed segment, considering that the switching applied is related exclusively to the isolation of failed sections and bars, as well as to supply electricity to the islands generated by the condition, with significant reduction in the number of applications of load flows, due to the use of sensitivity parameters for determining voltages and currents estimated on bars and lines of the feeders directly involved with that failed segment. A comparison between this process and classical methods is performed for different test networks from the literature about networks reconfiguration
Resumo:
This work has as main objective to show all the particularities regarding the Three-phase Power Summation Method, used for load flow calculation, in what it says respect to the influence of the magnetic coupling among the phases, as well as to the losses presented in all the existent transformers in the feeder to be analyzed. Besides, its application is detailed in the study of the short-circuits, that happen in the presence of high impedance values, which possess a problem, that is its difficult detection and consequent elimination on the part of common devices of protection. That happens due to the characteristic presented by the current of short¬ circuit, in being generally of the same order of greatness that the load currents. Results of simulations accomplished in several situations will be shown, objectifying a complete analysis of the behavior of the proposed method in several types of short-circuits. Confront of the results obtained by the method with results of another works will be presented to verify its effectiveness
Resumo:
This work presents a model of bearingless induction machine with divided winding. The main goal is to obtain a machine model to use a simpler control system as used in conventional induction machine and to know its behavior. The same strategies used in conventional machines were used to reach the bearingless induction machine model, which has made possible an easier treatment of the involved parameters. The studied machine is adapted from the conventional induction machine, the stator windings were divided and all terminals had been available. This method does not need an auxiliary stator winding for the radial position control which results in a more compact machine. Another issue about this machine is the variation of inductances array also present in result of the rotor displacement. The changeable air-gap produces variation in magnetic flux and in inductances consequently. The conventional machine model can be used for the bearingless machine when the rotor is centered, but in rotor displacement condition this model is not applicable. The bearingless machine has two sets of motor-bearing, both sets with four poles. It was constructed in horizontal position and this increases difficulty in implementation. The used rotor has peculiar characteristics; it is projected according to the stator to yield the greatest torque and force possible. It is important to observe that the current unbalance generated by the position control does not modify the machine characteristics, this only occurs due the radial rotor displacement. The obtained results validate the work; the data reached by a supervisory system corresponds the foreseen results of simulation which verify the model veracity
Resumo:
This dissertation dea1s with the active magnetic suspension controI system of an induction bearingIess motor configured with split windings. It analyses a dynamic modeI for the radial magnetic forces actuating on the rotor. From that, it proposes a new approach for the composition of the currents imposed to the machine's stator. It shows the tests accomplished with a prototype, proving the usefulness of the new actuating structure for the radial positioning controI. Finnaly, it points out the importance of adapting this structure to well-known rotational controI techniques, continuing this kind of equipment research, which is carried out at Federal University of Rio Grande do Norte since 2000
Resumo:
This work deals with the development of an experimental study on a power supply of high frequency that provides the toch plasmica to be implemented in PLASPETRO project, which consists of two static converters developed by using Insulated Gate Bipolar Transistor (IGBT). The drivers used to control these keys are triggered by Digital Signal Processor (DSP) through optical fibers to reduce problems with electromagnetic interference (EMI). The first stage consists of a pre-regulator in the form of an AC to DC converter with three-phase boost power factor correction which is the main theme of this work, while the second is the source of high frequency itself. A series-resonant inverter consists of four (4) cell inverters operating in a frequency around 115 kHz each one in soft switching mode, alternating itself to supply the load (plasma torch) an alternating current with a frequency of 450 kHz. The first stage has the function of providing the series-resonant inverter a DC voltage, with the value controlled from the power supply provided by the electrical system of the utility, and correct the power factor of the system as a whole. This level of DC bus voltage at the output of the first stage will be used to control the power transferred by the inverter to the load, and it may vary from 550 VDC to a maximum of 800 VDC. To control the voltage level of DC bus driver used a proportional integral (PI) controller and to achieve the unity power factor it was used two other proportional integral currents controllers. Computational simulations were performed to assist in sizing and forecasting performance. All the control and communications needed to stage supervisory were implemented on a DSP
Resumo:
The Methods for compensation of harmonic currents and voltages have been widely used since these methods allow to reduce to acceptable levels the harmonic distortion in the voltages or currents in a power system, and also compensate reactive. The reduction of harmonics and reactive contributes to the reduction of losses in transmission lines and electrical machinery, increasing the power factor, reduce the occurrence of overvoltage and overcurrent. The active power filter is the most efficient method for compensation of harmonic currents and voltages. The active power filter is necessary to use current and voltage controllers loop. Conventionally, the current and voltage control loop of active filter has been done by proportional controllers integrative. This work, investigated the use of a robust adaptive control technique on the shunt active power filter current and voltage control loop to increase robustness and improve the performance of active filter to compensate for harmonics. The proposed control scheme is based on a combination of techniques for adaptive control pole placement and variable structure. The advantages of the proposed method over conventional ones are: lower total harmonic distortion, more flexibility, adaptability and robustness to the system. Moreover, the proposed control scheme improves the performance and improves the transient of active filter. The validation of the proposed technique was verified initially by a simulation program implemented in C++ language and then experimental results were obtained using a prototype three-phase active filter of 1 kVA