41 resultados para Implantes de ancoragem
Resumo:
The tricalcium phosphate ceramics has been widely investigated in the last years due its bioresorbable behavior. The limiting factor of the application of these materials as temporary implants is its low strength resistance. The tricalcium phosphate presents an allotropic transformation β→α around 1250 ºC that degrades its resistance. Some studies have been developed in order to densify this material at this temperature range. The objective of this work is to study the influence of the addition of magnesium oxide (MgO) in the sintering of β-TCP. The processing route was uniaxial hot pressing and its objective was to obtain dense samples. The samples were physically characterized through density and porosity measurements. The thermal behavior was studied through dilatometric, thermal differential and thermogravimetric analysis. The mechanical properties were characterized by three point flexure test and Vickers microhardness measurements, analyzed of the microstructure. The addition of magnesium oxide doesn t cause an improvement of the mechanical strength in relation to material without additive.
Resumo:
The calcium phosphate ceramics have been very investigated as material for bone implants. The tricalcium phosphate (β-TCP) had a great potential for application in temporary implants like a resorbable bioceramic. This material presents a limitation in its sintering temperature due to occurrence of the allotropic transformation β → α at temperatures around 1200°C, not allowing the attainment of dense ceramic bodies. This transformation also causes cracks, what diminishes the mechanical strength, limiting its use to applications of low mechanical requests. This work studies the influence of the addition of manganese oxide in the sintering of β-TCP. Two processing routes were investigated. The first was the powder metallurgy conventional process. The test bodies (samples) were pressed and sintering at temperatures of 1200 and 1250°C. The second route was uniaxial hot pressing and its objective was to obtain samples with high relative density. The samples were physically characterized through density and porosity measurements. The thermal behavior was studied through dilatometric, thermal differential and thermogravimetric analysis. The mechanical properties were characterized by three point flexure test and Vickers microhardness measurements. The microstructure was analyzed by scanning electron microscopy. The addition of manganese oxide caused an improvement of the mechanical strength in relation to the material without additive and promoting the stabilization of β-TCP to greater temperatures
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Resumo:
The move to include students with special needs (NEE) in the schools presents a paradigm that raises continual discussion about how to implement this proposal. Considering that learning is built from the weaving of socially constructed knowledge and the field of knowledge concerning subjectivity, this research explores the difficulties that occur with the later in the process of inclusion in the schools. Admittedly, the promise implicit in the school does not guarantee that the student learn, but the envisioning of this learning, when the student s educator discredits him, is such that the person is then not taken on as an actual student, being excluded from the transmission of knowledge, even within the school. The project implemented at the Instituto Educacional Casa Escola IECE, for the last three years, shows us that the possibility and sustainability of this envisioning is intimately linked to the subjectivity of the educator, as well as how one relates to the institutional culture. We question then, how this perspective is formed in the educator this perspective capable of denying the offer of a place as student, allowing him to advance while learning. With this in mind, we explore the paradoxical elements present in the paradigm of inclusion, as well as analyzing theoretically, through the body of conceptual psychoanalysis, the process of subjective constitution. We intend to bring to light how this process coincides with the construction of the educator s perspective of exemption from teaching the special needs students. We question, through the formative functions of subjective structuring (The Mirror Stage and the Oedipus Complex), how to form a perspective capable of promoting inclusion of special needs students in educators. Finally, we show how it is possible to bring to light, with the concepts of the I ideal and the ideal I, the subjective difficulties in the practicing instructor
Resumo:
A introdução dos implantes dentários osseointegrados como uma ferramenta na reabilitação oral de pacientes edêntulos e parcialmente edêntulos é uma realidade no cotidiano do cirurgião-dentista. Estudos reportam uma alta taxa de sucesso da utilização de implantes no tratamento reabilitador. Entretanto, outras investigações têm mostrado a perda desses implantes devido a infecções peri-implantares, como a mucosite e a peri-implantite. O objetivo deste trabalho foi avaliar a frequência das doenças peri-implantares e seus fatores associados em pacientes com implantes dentais em função reabilitados no serviço odontológico da Faculdade de Odontologia da UFRN. Foram examinados 155 indivíduos portadores de 523 implantes e 2718 dentes. Dentes e implantes foram avaliados por meio de sondagem periodontal, observando-se a profundidade de sondagem, retração gengival, bem como foram avaliados índices de placa visível (IPV) e sangramento gengival (ISG) e presença de supuração. Os dados foram armazenados em fichas clínicas e avaliados estatisticamente por meio da estatística descritiva e inferencial. A idade média dos pacientes foi de 54,05 (± 12,61) anos, sendo 79,4% do sexo feminino. As frequências da mucosite, peri-implantite e periodontite em indivíduos foram 54%, 28% e 50%, respectivamente. Dos 523 implantes avaliados, 43% tinham mucosite, 14% peri-implantite e 43% saúde. Os testes Qui-quadrado de Pearson e Exato de Fisher mostraram que as doenças peri-implantares estão associadas as doenças periodontais, uso de medicação, alterações sistêmicas número de implantes, IPV, ISG, ao tempo de função das próteses, região do implante, número de roscas expostas e faixa de mucosa queratinizada (p<0,05). A análise de regressão múltipla, através da regressão binária logística, constatou que indivíduos que faziam uso de medicação (OR = 1,784), com um ISG > 10% (OR = 1,742), com implantes instalados na maxila (OR = 2,654), onde a prótese sobre o implante tinham mais de 2 anos em função (OR = 3,144) e que radiograficamente apresentavam uma perda óssea atingindo a terceira rosca do implante (OR = 4,701) mostram uma associação positiva com as doenças peri-implantares de maneira que esses indivíduos têm mais chances de ter essas doenças. Os resultados sugerem que a frequência das doenças peri-implantares na população em estudo foi de 82% dos pacientes e que estas doenças estão associadas a fatores relacionados aos indivíduos como: a presença da doença periodontal, piores IPV e IS, alterações sistêmicas, uso de medicação e maior número de implantes; e a fatores locais relacionados aos implantes como: ausência ou faixa de mucosa menor que 2mm, implantes na maxila e na região anterior, perda óssea atingindo a terceira rosca do implante e a um tempo de reabilitação prótetica maior que 2 anos
Resumo:
The aim of this study was to compare the misfit vertical, horizontal and passivity of zirconia and cobalt-chromium frameworks fabricated for CAD / CAM technology and conventional method of casting. Sixteen frameworks in one-piece, were obtained from a metallic matrix containing three Brånemark compatible implants with regular platform (Titamax Cortical Ti, Neodent). Eight frameworks were fabricated by CAD / CAM system (NeoShape, Neodent): four in zirconia (ZirCAD) and four cobalt-chromium (CoCrcad). Eight other frameworks were obtained by conventional casting method: four cobalt-chromium with UCLA abutment premachined Co-Cr (CoCrUCci) and four cobalt-chromium with UCLA abutment castable (CoCrUCc). The fit vertical, horizontal and passivity by one-screw test were measured using scanning electron microscopy with magnification of 250x. Initially evaluated the passivity by one-screw test and subsequently to assess the vertical and horizontal misfit, tightened all the screws with a torque of 20 Ncm. Mean, standard deviation, minimum and maximum values were calculated for each group. Measurements of horizontal misfit were transformed into cumulative frequency for categorization of the variable and the group later comparison groups. To evaluate the existence of quantitative differences between the groups tested for vertical misfit and passivity, we used the Kruskal-Wallis test. The Mann-Whitney test was used to compare group to group statistical differences (p <0.05). Were observed the respective mean and standard deviation for vertical misfit and passivity in micrometers: ZirCAD (5.9 ± 3.6, 107.2 ± 36), CoCrcad (1.2 ± 2.2, 107.5 ± 26 ), CoCrUCci (11.8 ± 9.8, 124.7 ± 74), CoCrUCc (12.9 ± 11.0, 108.8 ± 85). There were statistical differences in measures of vertical misfit (p = 0.000). The Mann-Whitney test revealed statistical differences (p <0.05) between all groups except between CoCrUCci and CoCrUCc (p = 0.619). No statistical difference was observed for the passivity. In relation to the horizontal misfit groups ZirCAD and CoCrcad did not show best values in relation to CoCrUCci and CoCrUCc. Based on the results it can be concluded that frameworks fabricated by CAD / CAM technology had better values of vertical fit than those manufactured by the casting method, nevertheless, the passivity was not influenced by manufacturing technique and material used. The horizontal fit obtained by frameworks manufactured by CAD / CAM was not superior to those manufactured by casting. A lower variability in vertical adjustment and passivity was observed when frameworks were fabricated by CAD / CAM technology
Resumo:
Edentulous patients with complaint about mandibular conventional denture might experience poor masticatory function and negative impact of oral health on quality of life. The aim of this controlled clinical trial was to evaluate the effect of mandibular overdenture on oral health-related quality of life and masticatory efficacy in patients wearing mandibular complete dentures. The edentulous patients (n=16) were rehabilitated with new maxillary and mandibular complete dentures and, after 3 months, mandibular overdentures retained by 2 implants (bar-clip system) were fabricated. The Brazilian version of OHIP-Edent questionnaire was used to assess the oral healthrelated quality of life. Masticatory efficacy was evaluated through a colorimetric method with chewing capsules. The mean OHIP-Edent score was 8.5 with conventional dentures and 2.0 with mandibular overdenture, which means a positive impact of oral health on quality of life with overdentures (p=0.001). The mean absorbance for masticatory efficacy was 0.025 for conventional dentures and 0.073 for overdentures. There was statistically significant difference for masticatory efficacy before and after implants rehabilitation (p=0.003). However, there was no correlation between masticatory efficacy and OHIP (p>0.05). So, mandibular overdenture retained by 2 implants improved the quality of life and masticatory efficacy of edentulous patients with complaint about mandibular conventional complete dentures
Resumo:
It has been shown that the development of peri-implant mucositis is associated with biofilm accumulation. It is believed that the therapeutic approaches used in periodontal disease may have a positive effect in the cases of peri-implant disease. The aim of this study was to evaluate the effectiveness of non-surgical treatment of peri-implant mucositis, with or without the use of chlorhexidine 0,12% in subjects rehabilitated with osseointegrated implants. Thus, patients were randomly divided into test group (chlorhexidine surgical therapy) and control (non-surgical treatment). This therapy consisted of an adaptation of the (Full Mouth scalling and Root Planing) nonoperative protocol FMSRP, but without the use of ultrasound. The visible plaque index (VPI), gingival bleeding index (GBI), probing depth (PD), bleeding on probing (BOP) and keratinized mucosa clinical parameters were evaluated at baseline and at different times after treatment. The data were not normally distributed and the implant was considered the sampling unit. Data were analyzed using Fri edman and Wilcoxon chi-square (=5%), tests using the Statistical Package for Social Sciences 17.0 (SPSS). Thus, 119 implants were evaluated, 61 in the test group and 58 in the control group. The results showed statistically significant differences for the variables: average BTI implants in both groups (p<0,001), mean ISG implants both in the test group (p<0,001), and control (p= 0,006) of implants; PS for the test group (p< 0,001) and control (p = 0,015) and SS (p<0,001) in the two treatment groups. However, there was no statistically significant difference when the groups were compared. The PS and SS variables showed no statistically significant difference in any of independent interest to the study (age, sex, smoking, treatment group, keratinized mucosa at different times, peri-implant biotype, average VPI implants and GBI). Thus, it can be concluded that both the mechanical treatment isolated as its association with chlorhexidine mouthwash 0.12% can be used for the treatment of peri-implant mucositis. Moreover, the condition of oral h ygiene has improved between baseline and six months and the depth and bleeding on probing decreased after three and six months
Resumo:
The objective of this research was to evaluate the passivity and strain induced in infrastructures screwed on abutments, made by CAD/CAM technology, and to compare these samples with parts manufactured by conventional casting. Using CAD/CAM technology, 4 samples were made from zirconia (Zircad) and 4 samples were manufactured from cobaltchrome (CoCrcad). The control groups were 4 specimens of cobalt-chrome, made by onepiece casting (CoCrci), for a total of 12 infrastructures. To evaluate the passivity, the infraestructures were installed on the abutments. One end was tightened and the vertical gap between the infrastructure and the prosthetic abutment was measured with scanning electron microscopy (250×). The mean strain in these infrastructures was analyzed via the photoelasticity test. A significant difference (p = 0.000) in passivity was observed between the control (CoCrci) and sample groups (CoCrcad and CoCrci). CoCrcad exhibited the best value of passivity (48.76 ± 13.45 μm) and CoCrci the worst (187.55 ± 103.63 μm), Zircad presented an intermediate value (103.81 ± 43.15 μm). When compared to the other groups, CoCrci showed the highest mean strain around the implants (17.19 ± 7.22 kPa). It was concluded that the zirconia infrastructure made by CAD / CAM showed a higher vertical marginal misfit than those made in cobalt-chromium alloy with the same methodology, however, the tension generated in the implants was similar. The CAD/CAM technology is more accurate for passivity and mean strain of infrastructure screwed on abutments than conventional manufacturing techniques
Resumo:
Theta rhythm consists of an electrophysiological hippocampal oscillation present in mammalian species (4-12 Hz with variations across species). This oscillation is present during active waking and is also prevalent in local field potentials (LFP) during rapid eye movement sleep (REM sleep). Several studies have shown that theta rhythm is important in cognitive tasks and that the medial septum is a key region for its occurrence. The septum sends cholinergic, GABAergic and glutamatergic projections to the hippocampus, which in turn projects axons to the septum. Besides the septum, other regions are involved in regulating theta rhythm, forming a complex network of interactions among brain areas that result in theta rhythm. Optogenetics is a recently developed method that has been widely used in various research areas. It allows us to manipulate the electrical activity of neurons through light stimulation. One of the existing techniques consists in using a viral vector to induce the neuronal expression of ion channels associated with the light-sensitive molecule rhodopsin (e.g. ChR2). Once infected, the neurons become sensitive to light of a particular wavelength. The present M. Sc. research aimed to perform luminous stimulation of the brain in anesthetized and freely behaving animals using chronically implanted electrodes and optical fibers in animals infected with a viral vector for ChR2 expression. Surgical viral injections were performed in the medial septum; histological results confirmed the expression of ChR2 by way of the presence of the eYFP reporter protein in the septum and also in hippocampal processes. Moreover, we performed acute experiments with luminous stimulation of the medial septum and LFP recordings of the septum and hippocampus of anesthetized animals. Action potentials were recorded in the septum. In these experiments we observed a significant increase in the firing rates of septal neurons during luminous stimulation (n = 300 trials). Furthermore, we found an early light-evoked response in the hippocampal LFP. Chronic experiments with luminous stimulation of the medial septum and hippocampus in freely behaving animals were also performed in combination with LFP recordings. We found that the luminous stimulation of the septum is able to induce theta rhythm in the hippocampus. Together, the results demonstrate that the luminous stimulation of the medial septum in optogenetically-modified animals causes relevant electrophysiological changes in the septum and the hippocampus.
Resumo:
This study has investigated texts written by students from two high school- 3 rd grade classrooms, a public school in Natal- RN, and their teachers in order to reveal the nature and relevance of the knowledge that has oriented the teacher in the process of evaluation of argumentative text, set in the genre, opinion article, produced in the school setting. The corpus analyzed is compound with a total of sixteen texts, four of them corresponding to the production of two teachers (two productions per teacher) and twelve on the production of six students (two productions per student, with three students per class). All material on the production of these subjects was collected throughout the 2008 school year, with special attention for students’ productions, which were collected only after being subjected to teacher evaluation. Working knowledge of text linguistics, discourse analysis, the theory of enunciation and the aesthetics of reception, we proceeded to the analysis of production, which in according to the methodological proposal, it was held in two stages: at first, the student and faculty productions were analyzed, separately, in order to verify what knowledge about the object these subjects revealed to have already assimilated. Secondly, two sets were compared (each teacher's texts with the texts of their students). The intention was to unravel the existence (or not) of a connection between the underlying knowledge to the textual production of these teachers and their knowledge manifested in the evaluative act when the interventions made on the productions of the learner. It was found that there is a close correlation between the knowledge revealed in this action and those evidenced in their written productions, which constitutes a strong argument to validate the thesis that teachers also have been shown little proficient in performing their role as producers and evaluators of texts.
Resumo:
The Textual Analysis of Discourse has its origin in Text Linguistics and it aims at studying the co(n)text meaning production based on the analysis of concrete texts by offering elements to the understanding of the text as a discourse practice throughout the plans or levels of linguistic analysis. In this perspective, we intend to investigate the enunciative responsibility phenomenon in the sentencing court judgment. To do so, we review the theoretical contributions of Textual Analysis of Discourse (ADAM, 2011) and the Enunciative Linguistics from various authors, among them, Rabatel (1998, 2003, 2004, 2005, 2008, 2009, 2010), Nølke (2001, 2005, 2009, 2013), Nølke, Fløttum and Norén (2004), Guentchéva (1994, 1996) and Guentchéva et al. (1994). In this direction, we investigate the enunciative responsibility through a range that comprises the phenomenon from four gradations, each one with a kind of point of view (PoV) and with links that may mark the assumption or the distance from the point of view. Regarding the legal approach of the thesis, our theoretical anchoring follows several authors, among them, Petri (1994), Soto (2001), Alvarez (2002), Alves (2003), Cornu (2005), Albi (2007), Bittar (2010), Asensio and Polanco (2011), López Samaniego (2006), López Montolío and Samaniego (2008), Montolío (2002, 2010, 2011, 2012, 2013), Sterling (2010), Prieto (2013), Lawrence and Rodrigues (2013) and Rodrigues, Passeggi and Silva Neto (2014). Our corpus is composed of 13 sentences from criminal cases arising from the district of Currais Novos-RN, completed in 2012. The results reveal how the judge, from various enunciative instances, builds the court decision, which allowed us to understand the configuration of (non) assumption of enunciative responsibility in the sentencing court judgment discourse genre. In conclusion, we perceive that the discourse units are envisaged or through the assumption, or the non assumption of PoV by the enunciative instances, what guides the producer organization argumentative text and his (her) communicative purposes. With that, the judge creates and/or modifies values and beliefs, induces and/or guides his (her) interlocutor by being able to demonstrate objectivity and/or preventing his (her) face through the mediated constructions or engage through the assumption of the enunciative responsibility of the propositional content of an utterance. In short, we reaffirm our belief that the (non) assumption of the enunciative responsibility configures as an argumentative mechanism strongly marked by the producer of the text with a view to their communicative purposes. The sentence, therefore, is constructed in this game of taking and/or not taking of statements according to argumentative orientation and the objectives of the text producer.
Resumo:
Porous structures are being widely investigated for use in biomedical implants, aiming to mechanically integrate and functionally the implant inside the bone tissue. Moreover, this structure is also important for drugs that can be stored and can induce and accelerate the process of osseointegration. With the purpose to investigate this effect, Ti, Nb and Sn metal powders, were sintered by plasma using a hollow cathode discharge. Sintering was performed in argon plasma set at 4 mbar pressure and temperatures of 500 ° C, 600 ° C and 700 ° C. Samples were also sintered in the electrical resistance furnace at 1200 ° C in order to compare plasma sintering with the conventional method. It was observed that plasma samples sintered with the hollow cathode configuration showed a gradient in porosity, while the samples sintered in the resistive furnace did not. Furthermore, differences in the microstructure of the samples were found, were a surface with higher porosity and ales porous core were obtained at different temperatures. The percolation profile of distilled water and the chemical compositions of the porous layers of the plasma treated samples were the main results obtained. Based on these results, we can conclude that this structure is particularly important for application in the biomedical field such as scaffolds for drug delivery and implants
Resumo:
The purpose of this study was to analyze the behavior of Sell-Side analysts and analysts propose a classification, considering the performance of the price forecasts and recom- mendations (sell-hold-buy) in the Brazilian stock market. For this, the first step was to analyze the consensus of analysts to understand the importance of this collective interven- tion in the market; the second was to analyze the analysts individually to understand how improve their analysis in time. Third was to understand how are the main methods of ranking used in markets. Finally, propose a form of classification that reflects the previous aspects discussed. To investigate the hypotheses proposed in the study were used linear models for panel to capture elements in time. The data of price forecasts and analyst recommendations individually and consensus, in the period 2005-2013 were obtained from Bloomberg R ○ . The main results were: (i) superior performance of consensus recommen- dations, compared with the individual analyzes; (ii) associating the number of analysts issuing recommendations with improved accuracy allows supposing that this number may be associated with increased consensus strength and hence accuracy; (iii) the anchoring effect of the analysts consensus revisions makes his predictions are biased, overvaluating the assets; (iv) analysts need to have greater caution in times of economic turbulence, noting also foreign markets such as the USA. For these may result changes in bias between optimism and pessimism; (v) effects due to changes in bias, as increased pessimism can cause excessive increase in purchase recommendations number. In this case, analysts can should be more cautious in analysis, mainly for consistency between recommendation and the expected price; (vi) the experience of the analyst with the asset economic sector and the asset contributes to the improvement of forecasts, however, the overall experience showed opposite evidence; (vii) the optimism associated with the overall experience, over time, shows a similar behavior to an excess of confidence, which could cause reduction of accuracy; (viii) the conflicting effect of general experience between the accuracy and the observed return shows evidence that, over time, the analyst has effects similar to the endowment bias on assets, which would result in a conflict analysis of recommendations and forecasts ; (ix) despite the focus on fewer sectors contribute to the quality of accuracy, the same does not occur with the focus on assets. So it is possible that analysts may have economies of scale when cover more assets within the same industry; and finally, (x) was possible to develop a proposal for classification analysts to consider both returns and the consistency of these predictions, called Analysis coefficient. This ranking resulted better results, considering the return / standard deviation.
Resumo:
A combinação da Moldagem por Injeção de pós Metálicos (Metal Injection Moulding MIM) e o Método do Retentor Espacial (Space Holder Method - SHM) é uma técnica promissora para fabricação de peças porosas de titânio com porosidade bem definida como implantes biomédicos, uma vez que permite um alto grau de automatização e redução dos custos de produção em larga escala quando comparado a técnica tradicional (SHM e usinagem a verde). Contudo a aplicação desta técnica é limitada pelo fato que há o fechamento parcial da porosidade na superfície das amostras, levando ao deterioramento da fixação do implante ao osso. E além disso, até o presente momento não foi possível atingir condições de processamento estáveis quando a quantidade de retentor espacial excede 50 vol. %. Entretanto, a literatura descreve que a melhor faixa de porosidade para implantes de titânio para coluna vertebral está entre 60 - 65 vol. %. Portanto, no presente estudo, duas abordagens foram conduzidas visando a produção de amostras altamente porosas através da combinação de MIM e SHM com o valor constante de retentor espacial de 70 vol. % e uma porosidade aberta na superfície. Na primeira abordagem, a quantidade ótima de retentor espacial foi investigada, para tal foram melhorados a homogeneização do feedstock e os parâmetros de processo com o propósito de permitir a injeção do feedstock. Na segunda abordagem, tratamento por plasma foi aplicado nas amostras antes da etapa final de sinterização. Ambas rotas resultaram na melhoria da estabilidade dimensional das amostras durante a extração térmica do ligante e sinterização, permitindo a sinterização de amostras de titânio altamente porosas sem deformação da estrutura.