A novel approach to producing improved bio-interfaces by combining continuous wave (CW) and pulsed plasma polymerization (PP) modes is reported. This approach has enabled the generation of stable interfaces with a higher density of primary amine functionality on metal, ceramic and semiconductor surfaces. Heptylamine (HA) was used as the amine-precursor. In this new design, a thin CW PPHA layer is introduced to provide strong cross-linking and attachment to the metal or semiconductor surfaces and to provide a good foundation for better bonding a pulsed PPHA layer with high retention of functional groups. The combined mode provides the pulsed mode advantage of a 3-fold higher density of primary amines, while retaining much of the markedly higher stability in aqueous solutions of the continuous mode.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a novel concept to determine the velocity and the location information of multiple mobile agents using Doppler radar has been introduced. Also, an expression for the minimum number of inline sensors needed to guarantee this estimation for n number of mobile agents has been obtained. Current methods use the time derivative of the displacement of adjacent position measurements to find the velocities of agents. This method is error prone, particularly, if the agents are accelerating. In our approach we incorporate direction-of-arrival (DOA) radar which tracks the location and the velocity of each and every agent in each measurement step.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

3-alkylpyrrole to the fabric surface. Direct applications of a conductive paint to the textile surface eliminate the exposure of the substrate to damaging oxidizing agents which allow the coating of more sensitive and delicate substrates. All textiles produced are tested for abrasion resistance and conductivity. For alkyl polypyrrole coated fabrics, the optimum carbon chain lengths are between n=10 and n=14, which result in optimum values of conductivity and solubility. The darkness of the tone is inversely related to the surface resistivity of the resulting conductive fabric. Therefore, deep black coatings have low resistivity whereas light gray coatings on a white fabric surface have higher surface resistivity. Longer alkyl chains result in higher surface resistivity in fabrics. The conductive coating of poly(3-decanylpyrrole) on the textile surface has a better abrasion resistance compared to that of an unsubstituted polypyrrole coating.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper investigates the location and velocity estimation problem involving multiple targets using the phase difference and frequency shift of the returned Doppler modulated signal. The minimal receiver configuration that addresses the data association and missing information problem is presented for the case of linear arrays. Non-linearly modeled Doppler radar measurements are used to obtain an accurate estimate of the target dynamics progressively in a linear framework utilizing a recently developed robust state estimation approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Microwave Doppler radar has received considerable attention as a non-contact form of measuring human respiration; in particular for long term monitoring. One of the main challenges in converting this into a viable application is to suppress or separate the artefacts and other interfering signals from the desired respiration signal using a less complex and practically feasible design for regular and potentially real time use. Existing systems either require complex experimental setups or multiple Doppler radar modules to achieve this. In this paper, we propose an approach based on EMD-ICA and approximate entropy ideas to systematically separate received Doppler shifted signal into distinct components and reconstruct the desired respiration pattern pertaining to respective physiological activity. Indeed this allows suppression of the undesirable artefacts and interference from other competing signals. Practical experiments confirmed comparable performance of the proposed method to the measurements obtained through chest straps which are widely used clinically for monitoring respiration.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose. The Menifocal Z is an alternating vision, concentric, bifocal gas-permeable (GP) contact lens; center distance is connected to near periphery by a smooth transition zone. The lens is produced using tisilfocon A (Menicon Z material), which is approved for up to 30 days of continuous wear (CW). The aim of this study was to evaluate the clinical performance of the Menifocal Z when worn for up to 30 days of CW for 6 months.

Methods. Thirty-five existing GP lens wearers were enrolled in the study. Subjects were fitted with Menifocal Z lenses and follow-up visits were conducted after 2 weeks of daily wear and 1 day, 1 week, 6 weeks, 3 and 6 months of CW. A range of objective and subjective clinical performance measures were assessed, including distance and near visual acuity, the physiological response to CW, and subjective evaluation of vision and comfort.

Results. Twenty-seven subjects (77%) completed the study and eight (23%) discontinued: five (14%) as a result of lens-related problems (four vision, one comfort) and three (9%) as a result of non-lens related reasons. Average CW time achieved by the subjects was 22 ± 2 days. Mean binocular logarithm of the minimum angle of resolution (logMAR) acuities at 6 months were: high contrast distance 0.03 (20/20-), low contrast distance 0.63 (20/80-), and high contrast near 0.26 (20/25, N4). Adverse responses and lens binding were minimal, and there were no significant increases in corneal staining, corneal vascularization, or superior palpebral conjunctival papillae over time (p > 0.05). Problems with night vision (distance and near) with the lenses were the most common difficulties reported by the subjects.

Conclusions. The Menifocal Z appears to be a promising option for presbyopic vision correction, providing successful correction of distance and near vision in a group of experienced GP lens wearers. The hyper Dk tisilfocon A (Menicon Z) material allowed for safe wear of the lenses on a CW basis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tracking mobile agents with a Doppler radar system mounted on a moving vehicle is considered in this paper. Dopplers modulated from mobile agents on the single frequency continuous wave signals are analyzed in order to estimate the positions and velocities of multiple mobile agents. The measurement noise is assumed to be Gaussian and the maximum likelihood estimation is utilized to enhance the localization accuracy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

 Improved methods of functionalizing the surfaces of multi-walled carbon nanotubes (MWCNTs) have been investigated. It is shown that a level of primary amines of 2.3%, higher than previously reported for any nitrogen-containing gas plasma treatment, can be achieved using a mixture of N2 and H2, which is preferable to using NH3. Even higher levels (3.5%) of primary amines can be achieved by coating the MWCNTs with a thin layer of plasma polymerized heptylamine. In both cases, the highest levels were achieved using a combined continuous plus pulsed plasma mode which was superior to either continuous wave or pulsed wave alone. The integrity of the MWCNT structure is maintained by the plasma treatments, and the functionalized surface improves the dispersion of the MWCNTs and their interfacial bonding with epoxy, giving superior nanoindentation performance of the composites.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Combining continuous wave and pulsed plasma modes enables strong interfacial bonding of high levels of desired surface functional groups. The method has been applied to a thin film of multiwalled carbon nanotubes, a nanostructured and relatively inert material, using N2 + H2 plasma. A high density of primary amine groups (~2.6%) was achieved without damaging the tube surface. Contact angle measurements, using different probe liquids, plus model calculations of surface energy agree well with the spectroscopy and electron microscope results, i.e., the polar part shows significant changes while the non-polar part was unchanged. These results indicate that the wettability changes in the thin film of carbon nanotubes by the plasma treatment are due to the changes in surface chemistry. This confirms the effectiveness and practicality of the improved plasma method that should greatly help the use of nanotubes in applications from biomaterials to nanocomposites.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose. Little is known about the contact lens prescribing habits of optometrists in North America. The purpose of this survey was to obtain data on the types of lenses and solutions prescribed by Canadian optometrists.

Methods. One thousand Canadian optometrists were surveyed annually over seven consecutive years (2000 to 2006; n = 7000) on their contact lens prescribing preferences. Each survey requested a range of information about the contact lenses prescribed to the first 10 patients after its receipt.

Results. Over this time period, 1008 (14.4%) of the surveys were returned, providing data on 9383 fits. During the seven-year period, the ratio of male:female fits was 1:2 (3123:6217, 43 not reported), with a mean age of 31.3 ± 13.6 years (range 2 to 82 years). The ratio of new fits to refits was 2:3 (3780:5518, 85 not reported), with 91.3% of all fits being soft contact lenses (SCL). Of the SCL fits, 59.5% were spherical, 28.5% toric, 9.7% multifocal, and 2.3% cosmetic tints. Gas permeable (GP) fits were 46.6% spherical, 18.6% toric, 19.5% multifocal, and 6.6% were for orthokeratology (OK). Over the seven-year period, SCL prescribed for continuous wear (CW) increased from 3.2% to 14.3% between 2000 and 2004 and reduced to 8.1% in 2006, for all fits. The use of mid-water content (MWC) materials decreased from 34.6% to 2.7% and the use of silicone hydrogel (SH) lenses increased from 61.4% to 96.2%, for all CW fits. GP lens continuous wear increased from 0.7% to 30.6% of all GP lens fits by 2006. Daily wear (DW) of SH lenses decreased from 49.6% (2000) to 33.7% (2004) and then increased to 86.1% in 2006, for SH fits. MWC SCL fit on a monthly planned replacement (PR) basis reduced in popularity over the seven-year period (75.0% to 39.9%) and in 2006 more patients were fit overall with SH lenses (42.9%). The use of non-PR SCL declined from 20.5% to 4.5% of all fits. Fitting of low-water content lenses also declined (15.1% to 7.0%). High-water content (5.4% to10.2%) and SH lenses (5.4% to 42.9%) both increased. By 2006, the majority of GP lenses fit were with high Dk (HDK) materials (50.3%).

Conclusions. The preferred contact lens modality for Canadian optometrists appears to be DW SCL, which are replaced monthly. The proportion of lenses used for CW peaked in 2004, with SH SCL being the preferred material. The market share for GP lenses remains relatively unchanged, with an increasing proportion used for OK and CW. The launch of DW SH lenses in 2004 resulted in a marked increase in their reported fits, with a similar effect following the launch of a HDK GP lens material for CW.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A three-step plasma treatment, including surface activation with argon, surface functionalization with oxygen and then thin film deposition using a pulsed plasma polymerization of hexamethyldisiloxane (HMDSO), was used in low-pressure plasma to improve the pilling resistance of knitted wool fabric. The pilling propensity of the treated samples was investigated and compared with the pilling propensity of untreated, argon activated and oxygen functionized samples and argon and oxygen plasma-treated samples that were afterwards subject to continuous wave plasma polymerization of HMDSO. With the three-step treatment, a pilling grade of four was achieved for the treated wool fabric, while that of untreated and other plasma-treated was two and three, respectively. For the three-step plasma-treated sample, a uniform HMDSO polymer coating of 300 nm thickness was obtained; X-ray photoelectron spectroscopy (XPS) showed the presence of the silicone element, and Fourier transform infrared (FTIR) spectroscopy confirmed the chemical structure of the coating. No apparent differences were found in the whiteness index between the treated and untreated wool knits, but there was deterioration in the bursting strength and handle of the plasma-treated wool samples.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A three-step plasma treatment—activation, functionalization and polymerization—has been used to deposit a thin plasma polymer with amine groups on carbon fibres (CFs). This plasma polymer has strong adhesion to the CF surface and the amine groups enable strong bonding to a matrix. The CFs were first treated by Ar plasma to activate and clean the surface, followed by O2 plasma to incorporate oxygen-containing functional groups, and finally a heptylamine thin film was deposited using combined continuous wave and pulsed plasma polymerization. Strong adhesion between the plasma polymer and the CF was observed. The fibre strength was not affected by the treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The traditional interpretation of a brand, and the means by which an organisation communicates its brand, might be considered a product of a modernist managerial paradigm, with its focus on consistency, control, and coherence (Brown 1995, 1999; Firat and Shultz 1997). With the emergence of postmodernism, this logic has been challenged by one of flexibility and openness, since consumers are no longer willing to commit or conform to any unified and consistent idea, system, or narrative. In order to explain this change in the management of brands, this paper will examine the Australian cultural brand, Next Wave, as a paradigmatic example. Next Wave offers an innovative brand management model founded on the interaction between the organisation and the content provider, i.e., the artist. Based on both aesthetic and conceptual experimentations, Next Wave is a dynamic brand in which shape and content are continually redefined in an interactive and mutual relationship between the artist and the organisation. Therefore, it can be argued that paradoxically, the organisation does not own its own brand. In fact, the ownership exists only from a legal point of view (as a trademark); the real artificer of the brand is the artist. Since it is not possessed nor controlled at all by the organisation, but is always subject to continuous evolutions and redefinitions, the Next Wave brand can be considered as a postmodern brand that is not strictly tied to marketing rules, but involves the target as an active participant in the brand creation process.