25 resultados para Stationary-phase

em Deakin Research Online - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mixed mode stationary phases utilize secondary retention mechanisms to add a dimensionality to the surface of high performance liquid chromatography (HPLC) adsorbents. This approach was used by several authors to improve the separation performance of single dimension separations. We explored the magnitude of these secondary interactions by performing an off-line two-dimensional (2D)-HPLC separation with a Scherzo SM-C18 column of a β-lactoglobulin tryptic digest with a mobile phase pH of 7 in the first dimension and 2 in the second. Mechanism divergence was determined using the peak capacity and a geometric approach to factor analysis, to measure the correlation. This separation was repeated with a C18 stationary phase as a control. It was found that the C18 column had a correlation coefficient of 0.784, smaller than the mixed mode column, 0.884. This indicated that the retention mechanisms of the C18 column were more divergent under these two pH environments than the mixed mode column. However, the SM-C18 still provided alternative selectivity of the peptides to that of the C18 and could be considered as a good alternative for further 2D-HPLC separations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The synthesis and chromatographic behavior of an analytical size mixed-mode bonded silica monolith was investigated. The monolith was functionalized by an in situ modification process of a bare silica rod with chloro(3-cyanopropyl)dimethyl silane and chlorodimethyl propyl phenyl silane solutions. These ligands were selected in order to combine both resonance and nonresonance π-type bonding within a single separation environment. Selectivity studies were undertaken using n-alkyl benzenes and polycyclic aromatic hydrocarbons in aqueous methanol and acetonitrile mobile phases to assess the methylene and aromatic selectivities of the column. The results fit with the linear solvent strength theory suggesting excellent selectivity of the column was achieved. Comparison studies were performed on monolithic columns that were functionalized separately with cyano and phenyl ligands, suggesting highly conjugated molecules were able to successfully exploit both of the π-type selectivities afforded by the two different ligands on the mixed-mode column.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundamental improvements to the experimental protocol of two-dimensional high performance liquid chromatography were developed to accomplish truly quantitative analyses of complex natural products. This included developing novel measurement techniques to elucidate the retention behaviour of monolithic columns. Approaches to streamline chromatographic method development were also explored.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The retention characteristics of phenyl type stationary phases for reversed phase high performance liquid chromatography are still largely unknown. This paper explores the retention process of these types of stationary phases by examining the retention behaviour of linear PAHs and n-alkylbenzenes on a series of propyl phenyl stationary phases that have changes in their ligand density (1.23, 1.31, 1.97, 2.50 μmol m−2). The aromatic and methylene selectivities increased with increasing ligand density until a point where a plateau was observed, overall the propyl phenyl phases had a higher degree of aromatic selectivity than methylene selectivity indicating that these columns are suitable for separations involving aromatic compounds. Also, retention characteristics relating to the size of the solute molecule were observed to be influenced by the ligand density. It is likely that the changing retention characteristics are caused by the different topologies of the stationary phases at different ligand densities. At high ligand densities, the partition coefficient became constant.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Phenyl type stationary phases of increasing spacer chain length (phenyl, methyl phenyl, ethyl phenyl, propyl phenyl and butyl phenyl, with 0–4 carbon atoms in the spacer chain, respectively) were synthesised and packed in house to determine the impact that the spacer chain length has on the retention process. Two trends in the aromatic selectivity, qaromatic, were observed, depending on whether the number of carbon atoms in the spacer chain is even or odd. Linear log k′ vs ϕ plots were obtained for each stationary phase and the S coefficient was determined from the gradient of these plots. For the phenyl type phases, the S vs nc plots of the retention factors of linear polycyclic aromatic hydrocarbons vs the number of rings exhibit a distinct discontinuity that between 3 and 4 rings, which increases with increasing spacer chain length for even phases but decreases for odd phases. Accordingly, we suggest that the retention factors depend differently on the number of carbon atoms in the spacer chain depending on whether this number is even or odd and that this effect is caused by different orientations of the aromatic ring relative to the silica surface.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Polystyrene behaviour in reversed phase high performance liquid chromatography was influenced mainly by the solvent system, but secondary affects were observed depending on the stationary phase. A variety of reversed phase columns were investigated using mobile phase combinations of dichlorom ethane-methanol, dichloromethane-acetonitrile, ethyl acetate-methanol and ethyl acetate-acetonitrile. Several different modes of behaviour were observed depending on the polymer solubility in the solvent system. In the dichloromethane-methanol solvent system, polymer-stationary phase interactions only occurred when the molecules had pore access. Retention of excluded polystyrene depended on the kinetics of precipitation and redissolution of the polymer. Peak splitting and band broadening occurred when the kinetics were slow and molecular weight separations were limited !o oligomers and polystyrenes lower than 5-10(4) dalton. Excellent molecular weight separations of polystyrenes were obtained using gradient elution reversed phase chromatography with a dichloromethane-acetonitrile mobile phase on C18 columns. The retention was based on polymer-stationary phase interactions regardless of the column pore size. Separations were obtained on large diameter pellicular adsorbents that were almost as good as those obtained on porous adsorbents, showing that pore access was not essential for the retention of high molecular weight polystyrenes. In the best example, the separation ranged from the monomer to 10(6) dalton in a single analysis. Very little adsorption of excluded polymers was observed on C8 or phenyl columns. Polystyrene molecular weight separations to 7-10(5) dalton were obtained in an ethyl acetate-acetonitrile solvent system on C18 columns. Adsorption was responsible for retention. When an ethyl acetate-methanol solvent system was used, no molecular weight separations were obtained because of complex peak splitting. Reversed phase chromatography was compared to size exclusion chromatography for the analysis of polydisperse polystyrenes. Similar results were obtained using both methods. However, the reversed phase method was less sensitive to concentration effects and gave better resolution.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The multidimensional high-performance liquid chromatography separations of the complex sample matrix found in café espresso coffee were completed on the propyl phenyl and butyl phenyl columns that contain 3 and 4 carbon atoms in the spacer chain, respectively. Phenyl type stationary phases are able to undergo unique π–π interactions with aromatic compounds. Previous works have found that there are differences in retention characteristics between these chain lengths and this was explored further here. It was found that when analysing the separations by quadrants, using a geometric approach to factor analysis and by measuring the normalised mean radius, subtle differences in the separations were observed and the butyl phenyl phase was more selective for the high to medium polarity species. However, there was very little difference in separation behaviour for the hydrophobic components within the coffee sample. Overall, the analysis of the entire separation showed very little difference.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

C1 and phenyl-type stationary phases were assessed in terms of their environmental impact on separations using as test solutes polycyclic aromatic hydrocarbons. Methanol (MeOH) and acetonitrile (ACN) mobile-phase gradients were employed. These stationary phases were examined to determine if different physical and chemical properties possessed by these surfaces decreased the organic solvent consumption, and yet maintained peak capacity. The cumulative energy demand (CED) was used to gauge the environmental impact of the separations. The separation of the polycyclic aromatic hydrocarbon test mixture using current methodologies (i.e. a C18/ACN combination) had a CED of 1.13 MJ-eq, and a peak capacity of 27 peaks (resolving 7 of 12 peak pairs with Rs>1). In comparison, a butyl phenyl stationary phase with a methanol mobile phase had a peak capacity of 26, but with a CED of 0.670 MJ-eq. Monolithic columns containing C18 and C1 phases were also tested. A monolithic C18 column with MeOH had the lowest CED at 0.675 MJ-eq, a peak capacity of 28 peaks and good resolving power (resolving ten peak pairs with Rs>1), suggesting that this is a viable option with respect to reducing environmental impact for these types of analyses.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The frontal analysis method was used to measure the adsorption isotherms of phenol, 4-chlorophenol, p-cresol, 4-methoxyphenol and caffeine on a series of columns packed with home-made alkyl-phenyl bonded silica particles. These ligands consist of a phenyl ring tethered to the silica support via a carbon chain of length ranging from 0 to 4 atoms. The adsorption isotherm models that fit best to the data account for solute–solute interactions that are likely caused by π–π interactions occurring between aromatic compounds and the phenyl group of the ligand. These interactions are the dominant factor responsible for the separation of low molecular weight aromatic compounds on these phenyl-type stationary phases. The saturation capacities depend on whether the spacer of the ligands have an even or an odd number of carbon atoms, with the even alkyl chain lengths having a greater saturation capacity than the odd alkyl chain lengths. The trends in the adsorption equilibrium constant are also significantly different for the even and the odd chain length ligands.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Phenyl‐type stationary phase surfaces are useful for the separation of highly aromatic compounds because of the extensive intermolecular forces between the π‐electron systems. For this reason, we studied the retention behaviour and selectivity of polycyclic aromatic hydrocarbons (PAHs) on Synergi polar‐RP and Cosmosil 5PBB chromatography columns using methanol/water, acetonitrile/water, benzene spiked (0.5%) methanol/water, and benzene spiked (0.5%) acetonitrile/water mobile phases. These four solvent systems were employed because π‐π. interactions between the aromatic solute (i.e., PAH) and the aromatic stationary phase should be inhibited in mobile phases that are also π electron rich, and hence a competitor for the analyte. Our results showed that the acetonitrile mobile phases were substantially stronger eluents than the methanol mobile phases, which was consistent with the premise that retention of aromatic compounds is sensitive to π‐π. interactions. Aside from changes in absolute retention, selectivity of the PAHs was also generally greater in methanol rather than acetonitrile mobile phases because the methanol did not attenuate the π‐π. bonding interactions between the PAH and the stationary phase; but, despite this, the retention behaviour of the Synergi polar‐RP column was similar to that observed on C18 columns. The excessive retention times of the Cosmosil 5PBB column were decreased dramatically when acetonitrile was used as the mobile phase; however, selectivity between structural isomers was lost.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Highly polar metabolites, such as sugars and most amino acids are not retained by conventional RP LC columns. Without sufficient retention low concentration compounds are not detected due ion suppression and structural isomers are not resolved. In contrast, hydrophilic interaction chromatography (HILIC) and aqueous normal phase chromatography (ANP) retain compounds based on their hydrophilicity and therefore provides a means of separating highly polar compounds. Here, an ANP method based on the diamond hydride stationary phase is presented for profiling biological small molecules by LC. A rapid separation system based upon a fast gradient that delivers reproducible chromatography is presented. Approximately 1000 compounds were reproducibly detected in human urine samples and clear differences between these samples were identified. This chromatography was also applied to xylem fluid from soyabean (Glycine max) plants to which 400 compounds were detected. This method greatly increases the metabolite coverage over RP-only metabolite profiling in biological samples. We show that both forms of chromatography are necessary for untargeted comprehensive metabolite profiling and that the diamond hydride stationary phase provides a good option for polar metabolite analysis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The chromatographic capacity factors (log k‘) for 32 structurally diverse drugs were determined by high performance liquid chromatography (HPLC) on a stationary phase composed of phospholipids, the so-called immobilized artificial membrane (IAM). In addition, quantitative structure-retention relationships (QSRR) were developed in order to explain the dependence of retention on the chemical structure of the neutral, acidic, and basic drugs considered in this study. The obtained retention data were modeled by means of multiple regression analysis (MLR) and partial least squares (PLS) techniques. The structures of the compounds under study were characterized by means of calculated physicochemical properties and several nonempirical descriptors. For the carboxylic compounds included in the analysis, the obtained results suggest that the IAM-retention is governed by hydrophobicity factors followed by electronic effects due to polarizability in second place. Further, from the analysis of the results obtained of two developed quantitative structure-permeability studies for 20 miscellaneous carboxylic compounds, it may be concluded that the balance between polarizability and hydrophobic effects is not the same toward IAM phases and biological membranes. These results suggest that the IAM phases could not be a suitable model in assessing the acid-membrane interactions. However, it is not possible to generalize this observation, and further work in this area needs to be done to obtain a full understanding of the partitioning of carboxylic compounds in biological membranes. For the non-carboxylic compounds included in the analysis, this work shows that the hydrophobic factors are of prime importance for the IAM-retention of these compounds, while the specific polar interactions, such as electron pair donor−acceptor interactions and electrostatic interactions, are also involved, but they are not dominant.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An algorithm was developed for 2DHPLC that automated the process of peak recognition, measuring their retention times, and then subsequently plotting the information in a two-dimensional retention plane. Following the recognition of peaks, the software then performed a series of statistical assessments of the separation performance, measuring for example, correlation between dimensions, peak capacity and the percentage of usage of the separation space. Peak recognition was achieved by interpreting the first and second derivatives of each respective one-dimensional chromatogram to determine the 1D retention times of each solute and then compiling these retention times for each respective fraction ‘cut’. Due to the nature of comprehensive 2DHPLC adjacent cut fractions may contain peaks common to more than one cut fraction. The algorithm determined which components were common in adjacent cuts and subsequently calculated the peak maximum profile by interpolating the space between adjacent peaks. This algorithm was applied to the analysis of a two-dimensional separation of an apple flesh extract separated in a first dimension comprising a cyano stationary phase and an aqueous/THF mobile phase as the first dimension and a second dimension comprising C18-Hydro with an aqueous/MeOH mobile phase. A total of 187 peaks were detected.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Metabolite profiling, HPLC, LC-QTOF-MS, GC-MS. A workflow will be presented for comprehensive metabolomics using LC- and GC-MS. Metabolomics is an emerging field in the suite of ‘omic’ approaches for Systems Biology. The goal of metabolomics is to detect the presence of all small-molecules in a biological sample. This presents a significant challenge due to the chemical diversity and large concentration range of metabolites. Currently, there is no single method which enables the entire metabolome to be analysed, therefore a suite of analytical approaches are required to increase the coverage of detected metabolites. The routinely used techniques for metabolite profiling are LC- and GC-MS and NMR. Here we present complementary approaches using MS hyphenated to different chromatographic techniques. GC-MS represent the most robust standardised technique for high throughput metabolite profiling however there are still no standard LC-based methods for profiling. Polar compounds represent the most challenging aspect of LC-based metabolomics. A robust chromatographic technique for profiling polar compounds using HILIC chromatography and QTOF-MS will be presented as well as the complimentary reverse phase LC-MS method. The polar separation was carried out using a diamond hydride column. This unique stationary phase provides stable retention times and fast re-equilibration which contrasts to other forms of HILIC stationary phases. These LC-based methods will be compared to the well established GC-MS method as well as NMRbased profiling.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Twomultidimensional HPLC separations of an Australian red wine are presented, >70% of the available separation space was used. A porous graphitic carbon (PGC) stationary phase was used as the first dimension in both separations with both RP core–shell and hydrophilic interaction chromatography fully porous columns used separately in the second dimension. To overcome peak analysis problems caused by signal noise and low detection limits, the data were pre-processed with penalised least-squares smoothing. The PGC × RP combination separated 85 peaks with a spreading angle of 71 and the PGC × hydrophilic interaction chromatography separated 207 peaks with a spreading angle of 80. Both 2D-HPLC steps were completed in 76 min using a comprehensive stop-and-go approach. A smoothing step was added to peak-picking processes and was able to greatly reduce the number of false peaks present due to noise in the chromatograms. The required thresholds were not able to ignore the noise because of the small magnitude of the peaks; 1874 peaks were located in the non-smoothed PGC × RP separation that reduced to 227 peaks after smoothing was included.