16 resultados para Long term evaluation

em Deakin Research Online - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Framing the Future is a major staff development initiative of the Australian National Training Authority (ANTA), designed to support the implementation of the National Training Framework (NTF). Since 1997 over 20,000 vocational education and training (VET) practitioners have participated in the program. The program was renamed Reframing the Future in 2001.

This study reports on research conducted on the long-term impacts of projects funded by Framing the Future in 1999 and 2000. John Mitchell and Sarah Wood from John Mitchell & Associates conducted the research from May 2000–May 2001.

Using twenty four case studies and the results of interviews and an extensive survey, the report provides evidence of high-skilled VET practitioners and high-performing VET organisations who ensure that their involvement in Framing the Future projects leads to long-term gains, particularly in support of the implementation of the NTF.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A variety of nutrition screening instruments have been developed and implemented for identifying the risk of undernutrition among community and hospitalized older adults. Despite the high prevalence of undernutrition amongst older adults in long-term care, few screening instruments have been developed or evaluated in this setting. This review aims to evaluate the validity, reproducibility and feasibility of nutrition screening instruments developed for use, or described as being used, with older adults in long-term care. Ten publications encompassing nine independent nutrition screening tools were identified using electronic databases and manual searches of reference lists. The Mini Nutritional Assessment-Short Form (MNA-SF) was the most widely evaluated nutrition screening instrument and met the requirements for a valid instrument (sensitivity and specificity >0.9) for use in the long-term care setting. Modified versions of the MNA for use in China and South Africa also demonstrated acceptable levels of sensitivity and specificity. Other nutrition screening instruments were found to have variable levels of sensitivity and specificity and while some demonstrated levels consistent with the MNA-SF, only two were evaluated across more than one study population, Body Mass Index (BMI)+weight loss and BMI+albumin. These same instruments reported the highest levels of inter-rater and test-retest reproducibility, although this was only tested in one other instrument (Chinese Nutrition Screen -modified MNA). In conclusion, it is evident from this review that further work in this area is needed. Based on validity, reproducibility and feasibility it appears that BMI+weight loss is the most suitable nutrition screening instrument for use in the long-term care setting at this time. MNA-SF is promising; however, there is currently no data for inter-rater or test-retest reproducibility in the long-term care setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To clinically evaluate long-term users of two different contact lens care preservative systems and to investigate whether prolonged use is associated with an increase in the prevalence of dry eye.

Methods: Eighty-nine wearers of group IV hydrogel or silicone hydrogel lenses participated in this one-visit, investigator-masked study. Subjects were required to have consistently used a polyhexamethylene biguanide (PHMB) or polyquaternium-1 (PQT) based solution for 2 years. Consistent use was defined as 80% for the past 2 years and 100% for the past year. Clinical assessments included: average and comfortable wear time; overall and end-of-day comfort; signs of dryness, discomfort, burning or stinging, grittiness or scratchiness and visual changes; non-invasive and fluorescein break-up-time; pre-ocular tear film lipids, tear meniscus height, Schirmer and fluorescein clearance tests; limbal and bulbar hyperemia; palpebral roughness; corneal and conjunctival staining; lens front surface wetting; and lens film deposits.

Results: Significantly more grittiness or scratchiness was reported by subjects using a PHMB-containing system (67% vs. 44%; P = 0.02). Palpebral roughness and hyperemia were significantly greater in the PHMB group wearing group IV lenses (P = 0.01 and P = 0.05, respectively). Corneal staining was significantly higher in the PHMB users in all four peripheral sectors (P < 0.01). Nasal and temporal conjunctival staining was also significantly higher for users of PHMB-containing systems (P < 0.05). Front surface lens wettability was significantly better for group IV PQT users compared to PHMB users (P = 0.008), with 84% vs. 72%, respectively, with lenses graded by the investigator as having good or excellent wettability. Significantly higher levels of lens front surface film deposits were noted with PHMB users (P = 0.007), with 58% of group IV lenses treated with PHMB compared with 38% of group IV lenses treated with PQT showing some lens front surface film deposition. No significant differences between the two preservative system groups were noted for the range of dry eye evaluations nor the remaining clinical assessments.

Conclusions: Differences in both ocular and lens characteristic were observed between long-term users of two preservative systems used in many contact lens multi-purpose solutions. The findings from this study did not support the hypothesis that prolonged use of PHMB-containing solutions leads to dry eye. Additional studies including a larger sample size and perhaps longer use of the systems could help to further elucidate differences in clinical performance between systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Long-term care settings provide care to a large proportion of predominantly older, highly disabled adults across the United States and Canada. Managing and improving quality of care is challenging, in part because staffing is highly dependent on relatively non-professional health care aides and resources are limited. Feedback interventions in these settings are relatively rare, and there has been little published information about the process of feedback intervention. Our objectives were to describe the key components of uptake of the feedback reports, as well as other indicators of participant response to the intervention. METHODS: We conducted this project in nine long-term care units in four facilities in Edmonton, Canada. We used mixed methods, including observations during a 13-month feedback report intervention with nine post-feedback survey cycles, to conduct a process evaluation of a feedback report intervention in these units. We included all facility-based direct care providers (staff) in the feedback report distribution and survey administration. We conducted descriptive analyses of the data from observations and surveys, presenting this in tabular and graphic form. We constructed a short scale to measure uptake of the feedback reports. Our analysis evaluated feedback report uptake by provider type over the 13 months of the intervention. RESULTS: We received a total of 1,080 survey responses over the period of the intervention, which varied by type of provider, facility, and survey month. Total number of reports distributed ranged from 103 in cycle 12 to 229 in cycle 3, although the method of delivery varied widely across the period, from 12% to 65% delivered directly to individuals and 15% to 84% left for later distribution. The key elements of feedback uptake, including receiving, reading, understanding, discussing, and reporting a perception that the reports were useful, varied by survey cycle and provider type, as well as by facility. Uptake, as we measured it, was consistently high overall, but varied widely by provider type and time period. CONCLUSIONS: We report detailed process data describing the aspects of uptake of a feedback report during an intensive, longitudinal feedback intervention in long-term care facilities. Uptake is a complex process for which we used multiple measures. We demonstrate the feasibility of conducting a complex longitudinal feedback intervention in relatively resource-poor long-term care facilities to a wider range of provider types than have been included in prior feedback interventions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although it is important for prospective studies, the reliability of quantitative measures of cervical muscle size on magnetic resonance imaging is not well established. The aim of the current work was to assess the long-term reliability of measurements of cervical muscle size. In addition, we examined the utility of selecting specific sub-regions of muscles at each vertebral level, averaging between sides of the body, and pooling muscles into larger groups. Axial scans from the base of skull to the third thoracic vertebra were performed in 20 healthy male subjects at baseline and 1.5 years later. We evaluated the semi-spinalis capitis, splenius capitis, spinalis cervicis, longus capitis, longus colli, levator scapulae, sternocleidomastoid, anterior scalenes and middle with posterior scalenes. Bland-Altman analysis showed all measurements to be repeatable between testing-days. Reliability was typically best when entire muscle volume was measured (co-efficients of variation (CVs): 3.3-8.1% depending on muscle). However, when the size of the muscle was assessed at specific vertebral levels, similar measurement precision was achieved (CVs: 2.7-7.6%). A median of 4-6 images were measured at the specific vertebral levels versus 18-37 images for entire muscle volume. This would represent considerable time saving. Based on the findings we also recommend measuring both sides of the body and calculating an average value. Pooling specific muscles into the deep neck flexors (CV: 3.5%) and neck extensors (CV: 2.7%) can serve to reduce variability further. The results of the current study help to establish outcome measures for interventional studies and for sample size estimation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Establishing the long-term repeatability of quantitative measures of lumbar intervertebral disc and spinal morphology is important for planning interventional studies. We aimed to examine this issue and to determine to what extent a smaller number of measurements per disc or vertebral level could be used to save operator time without compromising measurement precision. Twenty-one healthy male subjects were scanned at baseline and 1.5 years later. On sagittal MR-scans intervertebral disc cross-sectional area, anterior disc height, posterior disc height, intervertebral angle and intervertebral length were measured. The repeatability of the average value from all sagittal images or from 1, 3, 5 or 7 images centred at the spinous process was evaluated. Bland-Altman analysis showed all measurements to be repeatable between testing days. Intervertebral length was the most precise measurement (coefficients of variation [CVs] between 1.2% and 1.5%), followed by disc cross-sectional area (CVs between 2.9% and 3.6%). Variance component analysis showed that using 7 images, but not 1, 3 or 5 images, resulted in a similar level of measurement error as when measurements from all images were included.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent advancement in wearable technologies, particularly smart watches embedded with powerful processors, memory subsystems with various built-in sensors such as ac-celerometer, gyroscope and optical sensor in one single package has opened a whole new application space. One of the main applications of interest is the monitoring of movement patterns, heart rate, ECG and PPG particularly for longer duration's in natural environments. In this study, we conducted a performance evaluation on the optical heart rate sensor of the smartwatch with respect to the commonly used ECG and PPG devices. Results have shown that the heart rate acquired from the smartwatch is reasonably accurate with a high degree of correlation. Further, we conducted a preliminary exerise to evaluate sleep quality using the heart rate readings and accelerometer readings captured from the smartwatch and compared with a commercially available and clinically used non-contact sleep sensor, RESMED S+.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: This study assesses the long-term cost-effectiveness of a comprehensive model of mental health care for first-episode psychosis. The study is an extension of a previous economic evaluation of the Early Psychosis Prevention and Intervention Centre (EPPIC) that assessed the first-year costs and outcomes of treatment.

Method: The current study used a matched, historical control group design with a follow-up of approximately 8 years. Complete follow-up data were available for 65 of the original 102 participants. Direct public mental health service costs incurred subsequent to the first year of treatment and symptomatic and functional outcomes of 32 participants initially treated for up to 2 years at EPPIC were compared with a matched cohort of 33 participants initially treated by generic mental health services. Treatment-related resource use was measured and valued using Australian published prices.

Results: Almost 8 years after initial treatment, EPPIC subjects displayed lower levels of positive psychotic symptoms (P = .007), were more likely to be in remission (P = .008), and had a more favorable course of illness (P = .011) than the controls. Fifty-six percent of the EPPIC cohort were in paid employment over the last 2 years compared with 33% of controls (P = .083). Each EPPIC patient costs on average A$3445 per annum to treat compared with controls, who each costs A$9503 per annum.

Conclusions: Specialized early psychosis programs can deliver a higher recovery rate at one-third the cost of standard public mental health services. Residual methodological limitations and limited sample size indicate that further research is required to verify this finding.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Creatine monohydrate (CrM) supplementation appears to be relatively safe based on data from short-term and intermediate-term human studies and results from several therapeutic trials. The purpose of the current study was to characterize pathological changes after intermediate-term and long-term CrM supplementation in mice [healthy control and SOD1 (G93A) transgenic] and rats (prednisolone and nonprednisolone treated). Histological assessment (18-20 organs/tissues) was performed on G93A mice after 159 days, and in Sprague-Dawley rats after 365 days, of CrM supplementation (2% wt/wt) compared with control feed. Liver histology was also evaluated in CD-1 mice after 300 days of low-dose CrM supplementation (0.025 and 0.05 g · kg-1 · day-1) and in Sprague-Dawley rats after 52 days of CrM supplementation (2% wt/wt) with and without prednisolone. Areas of hepatitis were observed in the livers of the CrM-supplemented G93A mice (P < 0.05), with no significant inflammatory lesions in any of the other 18-20 tissues/organs that were evaluated. The CD-1 mice also showed significant hepatic inflammatory lesions (P < 0.05), yet there was no negative effect of CrM on liver histology in the Sprague-Dawley rats after intermediate-term or long-term supplementation nor was inflammation seen in any other tissues/organs (P = not significant). Dietary CrM supplementation can induce inflammatory changes in the liver of mice, but not rats. The observed inflammatory changes in the murine liver must be considered in the evaluation of hepatic metabolism in CrM-supplemented mice. Species differences must be considered in the evaluation of toxicological and physiological studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: The purpose of this study was to identify, compare, and explore advice nurses give to community-dwelling long-term indwelling catheter users on the use of sterile or clean urinary drainage bags, and to obtain information that would inform the design of a larger-scale international survey.


SUBJECTS AND SETTINGS: A survey was targeted to nurse members of the International Continence Society (n = 130). Respondents (n = 28; 21.5%) included nurses from Australia, Canada, Belgium, Switzerland, the United Kingdom, and the United States, who specialized in managing incontinence.


METHODS: The project was conducted as a descriptive, exploratory pilot study. Respondents completed an online anonymous survey that was distributed by the International Continence Society. The survey instrument was designed by the investigators and comprised 14 questions with both fixed and open-ended response options.


RESULTS: Most respondents in this survey advised indwelling catheter users to reuse their catheter bags (n = 15; 68%). Factors that influenced advice included concerns about the cost of catheter bags, an evaluation of the individual's infection risk, local and national policies, evidence-based guidelines, users' living arrangements, and their ability to clean the bags. Advice on decontamination methods varied; however, the most commonly recommended cleaning agent was water and vinegar, followed by a sterilizing or bleach solution or dishwashing detergent.


CONCLUSION:
Nurses play a key role in educating and supporting indwelling catheter users. Results of this study highlight variability in the advice nurses give to community-dwelling long-term indwelling catheter users about sterile or clean urinary drainage bags. This variability requires further investigation and affirms the need for a larger-scale study that draws on a broader sample of nurses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We assessed long-term trends in ethylene oxide (EtO) worker exposures for the purposes of exposure surveillance and evaluation of the impacts of the Occupational Safety and Health Administration (OSHA) 1984 and 1988 EtO standards. We obtained exposure data from a large commercial vendor and processor of EtO passive dosimeters. Personal samples (87 582 workshift [8-hr] and 46 097 short-term [15-min] samples) from 2265 US hospitals were analyzed for time trends from 1984 through 2001 and compared with OSHA enforcement data. Exposures declined steadily for the first several years after the OSHA standards were set. Workshift exposures continued to taper off and have remained low and constant through 2001. However, since 1996, the probability of exceeding the short-term excursion limit has increased. This trend coincides with a decline in enforcement of the EtO standard. Results indicate the need for renewed intervention efforts to preserve gains made following the passage and implementation of the 1984 and 1988 EtO standards.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This retrospective observational cohort study compared glycaemic control and long-term outcomes following transition from a modified intensive insulin therapy (mIIT) regimen to conventional glycaemic control (CGC) in adult patients admitted to a tertiary adult general intensive care unit, during two 24-month periods, before and after the publication of the Normoglycemia in Intensive Care Evaluation and Surviving Using Glucose Algorithm Regulation (NICE-SUGAR) trial. The before NICE-SUGAR cohort received mIIT (target glycaemic ranges 4.4 to 7.0 mmol/l), while the after NICE-SUGAR cohort received CGC (target glycaemic range 7.1 to 9.0 mmol/l). A total of 5202 patients were included in the study. With transition from mIIT to CGC, the mean time-weighted glucose increased from 6.94 mmol/l to 8.2 mmol/l (P <0.0001). A similar increase was observed in other glycaemic indices (mean, highest and lowest glucose values, P <0.0001 for all). The adjusted 90-day odds ratio for mortality decreased by 47% with transition from mIIT to CGC (odds ratio 1.47 (95% confidence interval, 1.22 to 1.78) (P <0.0001). The rate of severe and moderate hypoglycaemia also decreased from 1.2 to 0.4% (P=0.004) and from 23.3 to 5.9% (P <0.0001), respectively. mIIT was associated with an increased risk of moderate and severe hypoglycaemia compared to CGC (odds ratio 3.1 (1.51 to 6.39) (P=0.002), 6.29 (5.1 to 7.75) (P <0.0001)). Changes in recommended glycaemic control were translated into practice, with increased glycaemic indices and decreased rates of severe and moderate hypoglycaemia after the introduction of CGC. The associated decrease in 90-day mortality suggests mIIT was not superior to CGC, despite a lower hypoglycaemia rate than in previous IIT trials. Our findings support the continued use of CGC.