10 resultados para Intra-articular injection

em Deakin Research Online - Australia


Relevância:

80.00% 80.00%

Publicador:

Resumo:

We have investigated the role of bone sialoprotein (BSP), a secreted glycoprotein normally found in bone, in breast cancer progression. To explore functions for BSP in human breast cancer invasion and metastasis, the full-length BSP cDNA was transfected into the MDA-MB-231-BAG human breast cancer cell line under the control of the CMV promoter. Clones expressing BSP and vector control clones were isolated. BSP producing clones showed increased monolayer wound healing, a faster rate of stellate outgrowth in Matrigel and increased rate of invasion into a collagen matrix when compared to control clones. Clones were also examined in models of breast cancer growth and metastasis in vivo. BSP transfected clones showed an increased rate of primary tumor growth following mammary fat pad injection of nude mice. BSP transfected clones and vector control clones metastasized to soft organs and bone at a similar rate after intra-cardiac injection as determined by real-time PCR and X-ray analysis. Although these organs were targets for both BSP transfected and non-transfected cells, the size of the metastatic lesion was shown to be significantly larger for BSP expressing clones. This was determined by real-time PCR analysis for soft organs and by X-ray analysis of bone lesions. For bone this was confirmed by intra-tibial injections of cells in nude mice. We conclude that BSP acts to drive primary and secondary tumor growth of breast cancers in vivo.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Micro-robotic cell injection is typically performed manually by a trainedbio-operator, and success rates are often low. To enhance bio-operator performance during real-time cell injection, our earlier work introduced a haptically-enabled micro-robotic cell injection system. The system employed haptic virtual fixtures to provide haptic guidance according to articular performance metrics. This paper extends the work by replicating the system within a virtual reality (VR) environment for bio-operator training. Using the virtual environment, the bio-operator is able to control the virtual injection process in the same way they would with the physical haptic micro-robotic cell injection system, while benefiting from the enhanced visualisation capabilities offered by the 3D VR environment. The system is achieved using cost-effective components offering training at much lower cost than using the physical system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contrary to the expectations of many people, China's recent economic growth has not led to the collapse of the Chinese Communist Party. In fact, the party has recently carried out a peaceful and orderly transition to the so-called fourth generation of leadership, has revitalised itself, and created a new, younger and better trained cadre corps. Despite this successful transformation, there continue to be many problems that the party will need to overcome if it is to remain in power, including pressures for democratisation in both urban and rural areas, widespread corruption, the emergence of new social groups, and increasing dissatisfaction among workers who seem to be losing out in the present transition processs. This book explores the current state of the Chinese Communist Party and the many challenges which it faces.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

LabVIEW®-based software for the automation of a sequential injection analysis instrument for the determination of morphine is presented. Detection was based on its chemiluminescence reaction with acidic potassium permanganate in the presence of sodium polyphosphate. The calibration function approximated linearity (range 5 × 10 -10 to 5 × 10 -6M) with a line of best fit of y = 1.05 x + 8.9164 (R2 = 0.9959), where y is the log10 signal (mV) and x is the log10 morphine concentration (M). Precision, as measured by relative standard deviation, was 0.7% for five replicate analyses of morphine standard (5 × 10-8M). The limit of detection (3 σ) was determined as 5 × 10-11 M morphine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Flow injection methodology is described for the estimation of the total phenolic content of wine using acidic potassium permanganate chemiluminescence detection. Selected simple phenolic compounds including quercetin, rutin, catechin, epicatechin, ferulic acid, caffeic acid, gallic acid, 4-hydroxycinnamic acid and vanillin elicited analytically useful chemiluminescence with detection limits ranging between 4×10−10 and 7×10−7 M. A comparison between the chemiluminescence methodology and other total phenol/antioxidant assays, used by the food and beverage industry, resulted in a good correlation. The chemiluminescence detection was found to be selective with minimal interferences being observed from the non-phenolic components in wine. Analysis of 12 different wines showed that the chemiluminescence method was a rapid way to estimate their antioxidant or total phenolic content.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination of the amino acids proline, histidine, tyrosine, arginine, phenylalanine and tryptophan using flow injection analysis (FIA) with chemiluminescence detection is described. Proline was the only amino acid to exhibit chemiluminescence with the tris(2,2-bipyridyl)ruthenium(III) reaction at pH 10. While, histidine was found to selectively enhance the reaction of luminol with Mn(II) salts in a basic medium. Acidic potassium permanganate chemiluminescence was able to selectively determine tyrosine at pH 6.75. Low pressure separations using a C18 guard column allowed the simultaneous determination of tyrosine and tryptophan or phenylalanine and tryptophan with acidic potassium permanganate and copper(II)–amino acid–hydrogen peroxide chemiluminescence, respectively. Precision for each method was less than 3.9% (R.S.D.) for five replicates of a standard (1×10−5 M) and the detection limits ranged between 4×10−9 and 7×10−6 M. Preliminary investigations revealed that the methodology developed was able to selectively determine the individual amino acids in an equimolar mixture of the 20 naturally occurring amino acids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The measurement of both marketing culture and behaviour provides the opportunity to gain more insight into the overall market focus of organisations. This article seeks to determine the market orientation and marketing culture of all staff within organisations, to ascertain to what extent other members of an organisation support or create barriers to the successful implementation of the marketing concept. This paper will provide a brief overview of the existing literature in the field of market orientation and marketing culture. After detailing the research design and methodology, a summary developed from 11 focus group sessions - consisting of all staff in one public library service in Victoria, Australia - is presented. The findings indicate that while all areas within this organisation are committed to marketing, there are various interpretations of marketing and how it should be implemented. In addition, the research finds a number of factors that could be instrumental in the successful implementation of the marketing concept in public libraries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mono-isopropylamine salt of glyphosate was selectively determined directly in industrial and commercial formulations using flow injection analysis with tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence detection without the need for separation. Glyphosate and its mono-isopropylamine salt furnished detection limits of 7×10−9 and 3.5×10−10 M and relative standard deviations of 0.4% at 1×10−7 M and 0.8% at 5×10−8 M, respectively. The methodology is robust and reliable with samples subjected only to aqueous dilution prior to analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Flow injection methodology is described for the determination of proline in red and white wines using tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence detection. Selective conditions were achieved for proline at pH 10, while other amino acids and wine components did not interfere. The precision of the method was less than 1.00% (R.S.D.) for five replicates of a standard (4 × 10−6 M) and the detection limit was 1 × 10−8 M. The level of proline in white and sparkling wines using the developed methodology was equivalent to those achieved using HPLC-FMOC amino acid analysis. SPE removal of phenolic material was required for red wines to minimize Ru(bipy)33+ consumption and its associated effect on accuracy.