95 resultados para High Performance

em Deakin Research Online - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study explores the applicability of the personal and organizational value clusters identified by Abbott, White & Charles, (2005) employing the McDonald & Gandz (1991) list of values to university settings. It examines the personal values of business students in two universities, their perception ofthe organizational values important to their university, and measures the extent to which the personal and organizational values are consistent with 'High Performance Work Systems '. Results provide support for individual and organizational values factors similar to those found by Finegan, (2000) and Abbott et al. (2005) and consistent with Schwartz s (1992) an-cultural values hierarchy. While usiness/commerce students rated their personal values as consistent with HPWS and the major pan-cultural values, this did not match their perception of the organizations' values. The implications of personal-organizational value incongruence on motivation, satisfaction, organizational commitment and effectiveness are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports an investigation into the temporal stability of aqueous solutions of psilocin and psilocybin reference drug standards over a period of fourteen days. This study was performed using high performance liquid chromatography utilising a (955% vlv) methanol: 10 mM ammonium formate,
pH 3.5 mobile phase and absorption detection at 269 nm. It was found that the exclusion of light significantly prolonged the useful life of standards, with aqueous solutions of both psilocin and psilocybin being stable over a period of seven days.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The era of legislation and creditable methods towards producing sustainable buildings is upon us. Yet, a major barrier to achieving environmental responsive design is in the lack of available information at the programming or pre-design phases of a project. The review and evaluation of climate as well as energy-efficient strategies could be difficult to consider at these preliminary stages. Until recently, introducing energy simulation tools at the design stage has been difficult and perhaps next to impossible at a pre-design or programming stage. However, analysis of this sort is essential to ‘green building rating’ or performance assessment schemes such as LEED (Leadership in Energy and Environmental Design) and BREEAM (Building Research Establishment Environment Assessment Method). This paper discusses the implementation of a particular tool, ENERGY-10, where ‘basecase’ building defaults are compared to a low-energy case which has applied multiple energy-efficient strategies automatically. An annual hour-by-hour simulation provides a daylighting calculation with a subsequent thermal evaluation. Calculation results provide energy consumption, peak load equipment sizing, a RANK feature of the energy-efficient strategies, reporting of CO2, SO2 and NOx reduction, optimum glazing type as well as excellent graphic output. Consideration is given as to the approach of how such information can be introduced into the building project brief enforcing a low-energy
performance target.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study examines the extent to which the values consistent with the new organizational paradigm of High Performance Work Systems (HPWS) are perceived to be important to a range of professionals and the extent to which they are perceived to be important to organizations. Findings reveal there are contrasts between the hierarchies of individual and organisational values. There is stronger support by individuals than their organisations for the values underpinning the HPWS paradigm. These levels of individual - organisational value incongruence have implications for individual job satisfaction and motivation and for organizational effectiveness and in bridging the gap between the rhetoric of espoused values and reality of values in action.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple and sensitive HPLC method was developed to simultaneously determine CPT-11 and its major metabolite SN-38 in culture media and cell lysates. Camptothecin (CPT) was used as internal standard (I.S.). Compounds were eluted with acetonitrile–50 mM disodium hydrogen phosphate buffer containing 10 mM sodium 1-heptane-sulfonate, with the pH adjusted to 3.0 using 85% (w/v) orthophosphoric acid (27/73, v/v) by a Hyperclon ODS (C18) column (200 mm × 4.6 mm i.d.), with detection at excitation and emission wavelengths of 380 and 540 nm, respectively. The average extraction efficiencies were 96.9–108.3% for CPT-11 in culture media and 94.3–107.2% for CPT-11 in cell lysates; and 87.7–106.8% for SN-38 in culture media and 90.1–105.6% for SN-38 in cell lysates. Within- and between-day precision and accuracy varied from 0.1 to 10.3%. The limit of quantitation (precision and accuracy <20%) was 5.0 and 2.0 ng/ml for CPT-11 and 1.0 and 0.5 ng/ml for SN-38 in culture media and cell lysates, respectively. This method was successfully applied to quantitate the cellular accumulation and metabolism of CPT-11 and SN-38 in H4-II-E, a rat hepatoma cell line.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have combined high-performance liquid chromatography (HPLC) separations using a monolithic column with acidic potassium permanganate and tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence detection in a rapid and highly sensitive method to monitor the process of extracting opiate alkaloids from Papaver somniferum. Due to the high flow rates allowed with the monolithic column and the inherent selectivity of the chemiluminescence reactions, the four predominant alkaloids – morphine, codeine, oripavine and thebaine – were determined in less than 2 min. The results obtained with numerous process samples compared favourable with those of the standard HPLC methodology. Limits of detection were 1 × 10−10 M, 5 × 10−10 M, 5 × 10−10 M and 1 × 10−9 M, for morphine, codeine, oripavine and thebaine, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Adrenergic amines found in extracts of Citrus aurantium (bitter orange) evoke analytically useful chemiluminescence with acidic potassium permanganate in the presence of polyphosphates. From corrected chemiluminescence spectra, the wavelength of maximum intensity for these reactions was 680 ± 5 nm and, using flow injection analysis methodology, limits of detection for synephrine, octopamine, tyramine and hordenine were found to be between 1 × 10−9 and 1 × 10−8 M. We have applied this method of detection to the rapid determination of synephrine in dietary supplements using monolithic column chromatography.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A high-performance liquid chromatography (HPLC) method for the determination of urea that incorporates automated derivatisation with xanthydrol (9H-xanthen-9-ol) is described. Unlike the classic xanthydrol approach for the determination of urea, which involves the precipitation of dixanthylurea (N,N′-di-9H-xanthen-9-ylurea), the derivatisation procedure employed in this method produces N-9H-xanthen-9-ylurea, which remains in solution and can be quantified using fluorescence detection (λex = 213 nm; λem = 308 nm) after chromatographic separation from interferences. The limit of detection for urea was 5 × 10−8 M (0.003 mg L−1). This method was applied to the determination of urea in human and animal urine and in wine.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Irinotecan (CPT-11) and its main metabolite SN-38 are potent anticancer derivatives of camptothecin (CPT), with active lactone and inactive carboxylate forms coexisting. A simple and sensitive HPLC method using the ion-pairing reagent tetrabutylammonium hydrogen sulfate (TBAHS) was developed to simultaneously determine all four analytes in rat plasma samples. Camptothecin (CPT) was used as internal standard. The mobile phase was 0.1 M potassium dihydrogen phosphate containing 0.01 M TBAHS (pH 6.4)–acetonitrile (75:25, v/v). Separation of the compounds was carried out on a Hypersil C18 column, monitored at 540 nm (excitation wavelength at 380 nm). All four compounds gave linear response as a function of concentration over 0.01–10 μM. The limit of quantitation in rat plasma was 0.01, 0.008, 0.005 and 0.005 μM for CPT-11 lactone, CPT-11 carboxylate, SN-38 lactone and SN-38 carboxylate, respectively. The method was successfully used in the study on the effect of coadministered thalidomide on the plasma pharmacokinetics of CPT-11 and SN-38 in rats. Coadministered thalidomide (100 mg/kg body weight by intraperitoneal injection) significantly increased the AUC0–10h values of CPT-11 lactone and CPT-11 carboxylate by 32.6% and 30.3 %, respectively, (P < 0.01), but decreased the values by 19.2% and 32.4% for SN-38 lactone and carboxylate, respectively, (P < 0.05). Accordingly, the value of total body clearance (CL) of CPT-11 lactone was significantly lower in combination group compared to the control (1.329 versus 1.837 L/h/kg, P = 0.0002). Plasma t1/2β values for SN-38 lactone and carboxylate were significantly (P < 0.01) smaller in rats with coadministered thalidomide, as compared to rats receiving CPT-11 alone. Further studies are needed to explore the underlying mechanisms for the observed kinetic interaction between CPT-11 and thalidomide.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A sensitive and simple high performance liquid chromatography (HPLC) method was developed and validated for the determination of thalidomide in rat plasma. Chromatography was accomplished with a reversed-phase Hypersil C18 column. Mobile phase consisted of acetonitrile-10 mM ammonium acetate buffer (pH 5.50) (28:72, v/v), at a flow rate of 0.8 ml/min. Thalidomide was monitored by ultraviolet detector at 220 nm and it gave a linear response as a function of concentration over 0.02–50 μM. The limit of quantitation in rat plasma was 0.50 ng (0.02 μM plasma concentration) with an aliquot of 20 μl. Results from a 3-day validation study indicated that this method allows for simple and rapid quantitation of thalidomide with excellent accuracy and reliability. Using this validated assay, the effect of coadministered irinotecan (CPT-11) on the plasma pharmacokinetics of thalidomide in rats was determined. Coadministration of CPT-11 (intravenously, 60 mg/kg) increased the maximum plasma concentration (Cmax) and area under the plasma concentration–time curve (AUC0–10 h) of thalidomide by 32.29 and 11.66%, respectively, as compared to the control, but none of the effect of CPT-11 was of statistical significance (P > 0.05). Concomitant CPT-11 also caused a 10.04% decrease in plasma clearance (CL) and 14.51% decrease in volume of distribution (Vd) (P > 0.05). These results suggest that coadministered CPT-11 did not significantly alter the plasma pharmacokinetics of thalidomide in rats. Further studies are warranted to explore the pharmacokinetic and pharmacodynamic interactions between CPT-11 and thalidomide.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An accurate kinetics model is essential for understanding the curing mechanism and predicting the end properties of polymer materials. Graphite/epoxy AS4/ 8552 prepreg is a recent high-performance thermosetting composite modified with thermoplastic, which is being used in the manufacture of aircraft and military structures. The isothermal cures of this system along with another thermoplastic toughened high-performance prepreg, the T800H/3900-2 system, were investigated by real-time Fourier transform infrared (FTIR) spectroscopy. The cure rate was quantitatively analyzed based on the concentration profiles of both the epoxy and primary amine groups. Three autocatalytic models were used to determine kinetics parameters for both composite systems. The model which utilizes an empirical term, the final relative conversion (at different isothermal curing temperatures), describes the experimental data of both systems more satisfactorily than the model which applies a diffusion factor. The modeling results suggest that the curing of epoxy within both prepregs can be assumed to be a second order process.