Resumo:

 This research revealed the differences that occur when two forms of corrosion occur simultaneously in comparison to the individual corrosions, crevice and galvanic. It was shown that two forms of corrosion can actually reduce the amount of damage caused in selected conditions.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Compositional and structural changes within an electrolyte solution above an electrochemically active metal surface have been visualised using magnetic resonance imaging (MRI) for the first time. In these proof-of-concept experiments, zinc metal was galvanically corroded in a saturated lithium chloride solution. Magnetic resonance relaxation maps were taken during the corrosion process and spatial variations in both T1 and T2 relaxation times were observed to change with time. These changes were attributed to changes in the speciation of zinc ions in the electrolyte.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The alloying effect of a small amount of nickel on low alloy steel for application to flue gas desulfurization(FGD) systems was studied. The structural characteristics of the rust layer were investigated by scanning electron microscopy(SEM). The electrochemical properties were examined by means of potentiostatic polarization test, potentiodynamic polarization test, and electrochemical impedance spectroscopy(EIS) in a modified green death solution of 16.9 vol.% H2SO4+0.35 vol.% HC1 at 60°C and an acid rain solution of 6.25 X 10-5 M H2S04+5.5 X 10-3 M NaCl at room temperature. It was found that as the amount of nickel increased, the corrosion rate increased in the modified green death solution, which seemed to result from micro-galvanic corrosion between NiS and alloy matrix. In acid rain solution, the corrosion rate decreased as the amount of nickel increased due to the repulsive force of NiFe204 rust against Cl-ions by electronegativity.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

An electrochemically integrated multi-electrode array namely the wire beam electrode (WBE) has been used to characterize the behavior of cerium chloride (CeCl3) and lanthanum chloride (LaCl3) in inhibiting localized corrosion of AA2024-T3 and AA1100. CeCl3 has been found to inhibit AA2024-T3 corrosion in 0.005 M sodium chloride (NaCl) solution by suppressing galvanic corrosion activities and by creating a large number of insignificant anodes. It has also been shown to inhibit localized corrosion of AA1100 in 0.5 M NaCl solution by promoting the random distribution of minor anodes. LaCl3 has been found to inhibit localized corrosion of AA2024-T3 at 1000 ppm, although its efficiency dropped significantly when its concentration decreased to 500 ppm. The addition of CeCl3 and LaCl3 to corrosion testing cells at later stages was unable to effectively suppress existing corrosion anodes.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Electrochemical parameters including maximum anodic current density, total anodic current density, the number of anodic sites and the localised corrosion intensity index have been extracted from galvanic current distribution maps that were acquired using an electrochemically integrated multielectrode array, namely, the wire beam electrode. Experiments have been carried out to demonstrate the application of these new electrochemical parameters for characterising localised corrosion inhibition of metals. A typical corrosion inhibitor, potassium dichromate, was found to affect localised corrosion processes in various ways, for instance in sodium chloride solutions, it was found to inhibit localised corrosion of aluminium alloy AA 2024-T3 by suppressing galvanic corrosion activities occurring over the alloy surface, whereas it was found to control localised corrosion of AA 1100 by creating a large number of minor anodes distributing randomly over the metal surface.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The machined chips of 5083 Al alloy were recycled by hot extrusion at 723 K with an extrusion ratio of 44:1 in air. Corrosion and mechanical properties of the recycled specimens have been compared with those of a virgin extrusion which was processed from the ingot block. As a result of salt immersion tests, mass loss of the recycled specimen was not less than twice of that of the virgin extrusion. The deterioration in corrosion properties for the recycled specimen was attributed to the excessive contamination of Fe which promoted galvanic corrosion. As a result of tensile tests, the recycled specimen exhibited a good combination of high strength and high elongation to failure at room temperature. The excellent mechanical properties for the recycled specimen were attributed to the refined microstructure. However, the elongation to failure of the recycled specimen at elevated temperatures more than 573 K was lower than that of the virgin extrusion. The contamination of oxide particles is likely to be responsible for the lower elongation in the solid recycled specimen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose - The objective of this work was to develop practical experimental techniques for monitoring corrosion in "difficult-to-test" conditions such as corrosion under insulation (CUI).

Design/methodology/approach - An electrochemically integrated multi-electrode array namely the wire beam electrode (WBE) method has been used in combination with noise signature analysis for the first time to monitor the penetration of corrosive species under simulated corrosion-under-insulation conditions. Corrosion of aluminium exposed under insulation materials such as rock wool, glass wool, cotton wool and tissue paper has been successfully monitored.

Findings - A typical potential noise signature of a major potential jump from AA1100 WBE was observed which corresponded to the corrosive species reaching the WBE surface in WBE current distribution map. A good correlation between the galvanic current maps and the corroded surface was also observed.

Originality/value - The preliminary results suggest that the proposed novel electrochemical method is capable of monitoring CUI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel electrochemically integrated multi-electrode array namely the wire beam electrode(WBE) in combination with noise signatures analysis has been designed to monitor pittingcorrosion of one of the best corrosion resistance ferrous alloys, stainless steel type 316L.From the direct correlation of electrochemical potential noise signatures and galvanic currentdistribution maps during pitting corrosion processes, two characteristic noise patterns wereobserved prior to stable pit formation: (i) the characteristic ‘peak’ of rapid potential transient,towards less negative direction, followed by recovery (termed noise signature I) was found tocorrelate with the disappearance of unstable anode; (ii) the characteristic noise pattern ofquick potential changes towards less negative direction followed by no recovery (termed noisesignature II) was found to correspond with the massive disappearance of minor anodes leadingto formation of highly localized major anodes in the galvanic current distribution maps.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An auto-switch device has been designed, constructed, and tested for multisensor corrosion measurements. The auto-switch is able to connect/disconnect the selected wire beam electrode and/or electrode pairs under computer control. A computer controlled analog switch-array consisting of 100 inputs has been used as an essential part of the switch bank. The switch-bank is an essential component of a corrosion-monitoring instrument that is expected to find wide application in industry. The performance of the switch-bank is discussed and its effect on the signals is illustrated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Parameters extracted from the wire beam electrode (WBE) galvanic current maps have been used in conjunction with electrochemical noise patterns to directly quantify the degree of localised corrosion inhibition provided by inhibitors and to understand the mechanism of localised corrosion inhibition. The behaviour of two traditional localised corrosion inhibitors has been assessed by their effects on the maximum anodic current density (imax), total anodic current density (itot), the number of anodic sites (Na) and the localised corrosion intensity index (LCII). Typical experiments are presented to illustrate the application of these parameters in providing useful information on the efficiency and mechanism of localised corrosion inhibition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Corrosion has significant adverse effects on the durability of reinforced concrete (RC) structures, especially those exposed to a marine environment and subjected to mechanical stress, such as bridges, jetties, piers and wharfs. Previous studies have been carried out to investigate the corrosion behaviour of steel rebar in various concrete structures, however, few studies have focused on the corrosion monitoring of RC structures that are subjected to both mechanical stress and environmental effects. This paper presents an exploratory study on the development of corrosion monitoring and detection techniques for RC structures under the combined effects of external loadings and corrosive media. Four RC beams were tested in 3% NaCl solutions under different levels of point loads. Corrosion processes occurring on steel bars under different loads and under alternative wetting - drying cycle conditions were monitored. Electrochemical and microscopic methods were utilised to measure corrosion potentials of steel bars; to monitor galvanic currents flowing between different steel bars in each beam; and to observe corrosion patterns, respectively. The results indicated that steel corrosion in RC beams was affected by local stress. The point load caused the increase of galvanic currents, corrosion rates and corrosion areas. Pitting corrosion was found to be the main form of corrosion on the surface of the steel bars for most of the beams, probably due to the local concentration of chloride ions. In addition, visual observation of the samples confirmed that the localities of corrosion were related to the locations of steel bars in beams. It was also demonstrated that electrochemical devices are useful for the detection of RC beam corrosion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of the second phase Mg17Sr2 on the biocorrosion behavior of Mg5ZrxSr (x = 0, 2, 5 wt%) alloys before and after solution treatment was investigated. Electrochemical impedance spectroscopy, cathodic polarization and hydrogen evolution were used to evaluate the biocorrosion of Mg5ZrxSr. We found that Mg17Sr2 precipitated on boundary zones and enhanced the galvanic effect, leading to a severer corrosion of the Mg matrix adjacent to Mg17Sr2. The corrosion subsequently spread gradually from the regions adjacent to the Mg17Sr2 to the central Mg matrix. However, a high volume fraction of Mg17Sr2 could also form a continuous network, isolate the Mg matrix and act as a barrier of corrosion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of the heat treatment on the corrosion behaviour of amorphous Al88Ni6La6 made by melt-spun has been investigated by electrochemical measurements. Heat treatment was carried out at 523 K and 673 K for 4 min and 15 min respectively. The evolution of the crystallization process after annealing was identified by differential scanning calorimeter (DSC) as well as X-ray diffraction. The XRD patterns show that the structure of samples heat-treated at higher temperature changes towards a crystal state. The results obtained from the polarization curves reveal that all Al88Ni6La6 alloys exhibit spontaneously passivated behaviour. Furthermore, it is noted that the partially crystallized alloy has the best corrosion resistance in comparison with as-spun amorphous and fully crystallized alloys, while the fully crystallized sample shows deterioration in the corrosion resistance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of crystallization on the corrosion resistance of a  Cu52.5Ti30Zr11.5Ni6 bulk amorphous alloy in 1 mol/L HCl, and 6 mol/L NaOH solutions were studied. The amorphous alloy was identified by  differential thermal analysis(DSC) and by X-ray diffraction(XRD). The partially and fully crystallized alloys were prepared by controlling the annealing  temperatures at 738 and 873 K for 1 and 12 min, respectively, and the corrosion resistances of those annealed alloys were compared with that of the amorphous alloy by immersion test and potentiodynamic measurements in 1 mol/L HCl and 6 mol/L NaOH solutions. The results show that the  partially crystallized alloy exhibits high corrosion resistance, whereas full crystallization results in deteriorated corrosion resistance compared with that of the as-cast amorphous alloy.