71 resultados para GLASSY-CARBON ELECTRODE

em Deakin Research Online - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

.A novel electrochemical sensing platform was developed based on flower-like gold–zinc oxide core–shell nanoparticles and a graphene nanocomposite-modified glassy carbon electrode. The gold–zinc oxide core–shell nanoflowers were synthesized by seed growth and characterized by high-resolution transmission electron microscopy, energy-dispersive X-ray spectroscopy, and ultraviolet-visible absorption spectroscopy. The modified electrode provided good electrocatalytic properties, rapid response, high stability, and favorable reproducibility for determination of ascorbic acid. The performance of the sensor included a linear dynamic range from 1.0 × 10−7 to 6.0 × 10−4 M, a limit of detection of 3.9 × 10−8 M, and a sensitivity of 24.12 µA/mM. The nanocomposite also provided excellent selectivity and lower potential for the oxidation of ascorbic acid. The sensor was used for the determination of ascorbic acid in tablets with satisfactory results. This device provides rapid, simple, and selective determination of ascorbic acid.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Immobilization of catechol derivatives on GC electrode surfaces can be performed by in situ generation and reduction of nitrocatechol. We present the oxidative nitration of catechol in the presence of nitrous acid followed by electrochemically reduction of the generated nitro aromatic group to the corresponding amine group and its conversion to diazonium cation at the electrode surface to yield a surface covalently modified with catechol. In this manner, some derivatives of catechol can be immobilized on the electrode surface. Whole of the process is carried out in Triethylammonium acetate ionic liquid as an inert and neutral medium (pH∼7.0). Surface coverage can be easily controlled by the applied potential, time and concentration of catechol. After modification, the electrochemical features of modified surface have been studied. Also modified GC electrode exhibited remarkable catalytic activity in the oxidation of NADH. The catalytic currents were proportional to the concentration of NADH over the range 0.01-0.80 mM. This condition can be used for modification of GC surfaces by various aromatic molecules for different application such as design of sensors and biosensors. © 2014 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The tris(2,2′-bipyridyl) complexes of cobalt(II) and (III) ([Co(bpy)3]2+/3+) produce a redox couple of great interest in thermoelectrochemical cells and dye sensitized solar cells including both types of devices based on ionic liquid electrolytes. We present a systematic study of the electrochemistry of [Co(bpy)3]2+ [NTf2]-2 in two ionic liquids (ILs) based on the 1-ethyl-3-methylimidazolium (C2mim) cation and two ILs based on the 1-butyl-1-methylpyrrolidinium cation (C4mpyr), as well as three aprotic molecular solvents. Platinum (Pt) and glassy carbon (GC) working electrodes were compared. In all solvents better electrochemical responses were observed on GC, which yielded higher currents in the cyclic voltammograms and lower rate constants for the redox reaction. The [Co(bpy)3]1+/2+ couple is also readily observed, but this redox reaction is chemically irreversible, possibly because the [Co(bpy)3]1+ complex dissociates. However, the [Co(bpy)3]1+/2+ reaction is chemically reversible in all of the solvents studied, except 3-methoxypropionitrile, if excess of 2,2′-bipyridyl is added to the solution.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, six types of typical bio-wastes are used to prepare activated carbons (ACs) by high-temperature carbonization and activation with KOH. A novel electrochemical sensor for rutin was developed based on a peanut shell-derived activated carbon and gold nanoparticle composite modified glassy carbon electrode (P-AC/AuNPs/GCE). The as-synthesized ACs and composites were characterized by a variety of physicochemical techniques. The proposed sensor exhibits ideal electrochemical behavior for rutin with a wide linear range, low detection limit, and good selectivity. The desirable electrochemical performance enables the biomass-derived ACs and their composites to act as new sources of carbonaceous materials for electrochemical sensors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The high sensitivity that can be attained using a bienzymatic system and mediated by the redox polymer [Os(bpy)2ClPyCH2NHpoly(allylamine)] (Os-PAA), has been verified by on-line interfacing of a rotating bioreactor and continuous-flow/stopped-flow/continuous-flow processing. When the hydrogen peroxide formed by LOx layer reaches the inner layer, the electronic flow between the immobilized peroxidase and the electrode surface produces a current, proportional to lactate concentration. The determination of lactate was possible with a limit of detection of 5 nmol l−1 in the processing of as many as 30 samples per hour. This arrangement allows working in undiluted milk samples with a good stability and reproducibility. Horseradish peroxidase [EC 1.11.1.7] and Os-PAA were covalently immobilized on the glassy carbon electrode surface (upper cell body), lactate oxidase [EC 1.1.3.x] was immobilized on a disk that can be rotated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Graphene is scientifically and commercially important because of its unique molecular structure which is monoatomic in thickness, rigorously two-dimensional and highly conjugated. Consequently, graphene exhibits exceptional electrical, optical, thermal and mechanical properties. Herein, we critically discuss the surface modification of graphene, the specific advantages that graphene-based materials can provide over other materials in sensor research and their related chemical and electrochemical properties. Furthermore, we describe the latest developments in the use of these materials for sensing technology, including chemical sensors and biosensors and their applications in security, environmental safety and diseases detection and diagnosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A sensitive electrochemical acetylcholinesterase (AChE) biosensor based on a reduced graphene oxide (rGO) and silver nanocluster (AgNC) modified glassy carbon electrode (GCE) was developed. rGO and AgNC nanomaterials with excellent conductivity, catalytic activity and biocompatibility offered an extremely hydrophilic surface, which facilitated the immobilization of AChE to fabricate the organophosphorus pesticide biosensor. Carboxylic chitosan (CChit) was used as a cross-linker to immobilize AChE on a rGO and AgNC modified GCE. The AChE biosensor showed favorable affinity to acetylthiocholine chloride (ATCl) and could catalyze the hydrolysis of ATCl. Based on the inhibition effect of organophosphorus pesticides on the AChE activity, using phoxim as a model compound, the inhibition effect of phoxim was proportional to its concentration ranging from 0.2 to 250 nM with a detection limit of 81 pM estimated at a signal-to-noise ratio of 3. The developed biosensor exhibited good sensitivity, stability and reproducibility, thus providing a promising tool for analysis of enzyme inhibitors and direct analysis of practical samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The one-electron reduction of [α2-FeIII(OH2)P2W17O61]7- at a glassy carbon electrode was investigated using cyclic and rotating-disk-electrode voltammetry in buffered and unbuffered aqueous solutions over the pH range 3.45−7.50 with an ionic strength of approximately 0.6 M maintained. The behavior is well-described by a square-scheme mechanism P + e- ↔ Q (E10/ = −0.275 V, k10/ = 0.008 cm s-1, and α1 = 1/2), PH+ + e- ↔ QH+ (E20/ = −0.036 V, k20/ = 0.014 cm s-1, and α2 = 1/2), PH+ ↔ P + H+ (KP = 3.02 × 10-6 M), and QH+ ↔ Q + H+ (KQ = 2.35 × 10-10 M), where P, Q, PH+, and QH+ correspond to [α2-FeIII(OH)P2W17O61]8-, [α2-FeII(OH)P2W17O61]9-, [α2-FeIII(OH2)P2W17O61]7-, and [α2-FeII(OH2)P2W17O61]8-, respectively; E10‘ and E20‘ are the formal potentials, k10‘ and k20‘ are the formal (standard) rate constants, and KP and KQ are the acid dissociation constants for the relevant reactions. The analysis for the buffered media is based on the approach of Laviron who demonstrated that a square scheme with fully reversible protonations, reversible or quasi reversible electron transfers with the assumption that α1 = α2, can be well-described by the behavior of a simple redox couple, ox + e- ↔ red, whose formal potential, Eapp0‘, and standard rate constant, kapp0‘, are straightforwardly derived functions of pH, as are the values of E10‘, k10‘, E20‘, k20‘, and KP (only three of the four thermodynamic parameters in a square scheme can be specified). It was assumed that αapp = 1/2, and the simulation program DigiSim was used to determine the values of Eapp0‘ and kapp0‘, which are required to describe the cyclic voltammograms obtained in buffered media in the pH range from 3.45 to 7.52 (buffer-related reactions which effect general acid−base catalysis are included in the simulations). DigiSim simulations of cyclic voltammograms obtained in unbuffered media yielded the values of E10‘ and k10‘; KQ was then directly computed from thermodynamic constraints. These simulations included additional reactions between the redox species and H2O. The value of the diffusion coefficient of the [α2-FeIII(OH2)P2W17O61]7-, 2.92 × 10-6 cm2 s-1, was determined using DigiSim simulations of voltammograms at a rotating disk electrode in buffered and unbuffered media at pH 3.45. The diffusion coefficients of all redox species were assumed to be identical. When the pH is greater than 6, instability of P (i.e., [α2-FeIII(OH)P2W17O61]8-) led to the loss of the reactant and precluded lengthy experimentation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel electrochemical sensor for highly sensitive and selective detection of dopamine (DA) was developed based on a graphene quantum dots (GQDs) and Nafion composite modified glassy carbon electrode (GCE). GQDs were synthesized by a hydrothermal approach for cutting graphene sheets into GQDs and characterized by TEM, UV-vis, photoluminescence, and FT-IR spectra. The GQDs had carboxyl groups with a negative charge, which not only provided good stability, but also enabled interaction with amine functional groups in DA through electrostatic interaction to enhance the specificity of DA. The interaction and electron communication between GQDs and DA can be further strengthened via π-π stacking force. Nafion was used as an anchoring agent to increase the robustness of GQDs on the electrode surface and sensor stability and reproducibility. The GQDs-Nafion composite exhibits a good linear range of 5 nM to 100 μM and a limit of detection as low as 0.45 nM in the detection of DA. The proposed electrochemical sensor also displays good selectivity and high stability and could be used for the determination of DA in real samples with satisfactory results. The present study provides a powerful avenue for the design of an ultrasensitive detection method for clinical application.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To meet the urgent requirement of determining trace Pb2+ and Cd2+ in seawater on site, herein we developed a simple but novel electrochemical method, named as double stripping voltammetry, using only a portable heavy metal analyzer. The proposed method consisted of three steps: First, the targeted heavy metal ions in bulk solution were concentrated onto an ionic liquid-graphite-based paste working electrode (ILGPE), which exhibits a dramatic ability of accumulation, by electrodeposition in the presence of Bi3+. Second, the three-electrode arrangement, including the ILGPE loaded with the reduced products, was transferred into 1.0mL acetate buffer solution, followed by a stripping procedure. Third, the measurement was performed with the other stripping voltammetry procedure by using a glassy carbon electrode as working electrode. Under optimum conditions, the linear range values for Pb2+ and Cd2+ in seawater were 0.2-3.2 μg/L and 0.1-3.2 μg/L, respectively. The concentrations of Pb2+ and Cd2+ in five real samples collected from coastal sites of Qingdao City were determined on site, and the results were in good agreement with that obtained with the atomic absorption spectroscopy method. In addition, the analytical performance of working electrode modified with Bi film by in situ mode was investigated in comparison with that by ex situ mode. The results showed that the in situ mode was much better than the ex situ one.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The modification of glassy carbon electrodes with random dispersions of nanotubes is currently the most popular approach to the preparation of carbon nanotube modified electrodes. The performance of glassy carbon electrodes modified with a random dispersion of bamboo type carbon nanotubes was compared with single walled carbon nanotubes modified glassy carbon electrodes and bare glassy carbon electrodes. The electrochemical performance of all three types for electrode were compared by investigating the electrochemistry with solution species and the oxidation of guanine and adenine bases of surface adsorbed DNA. The presence of edge planes of graphene at regular intervals along the walls of the bamboo nanotubes resulted in superior electrochemical performance relative to SWNT modified electrodes from two aspects. Firstly, with solution species the peak separation of the oxidation and reduction waves were smaller indicating more rapid rates of electron transfer. Secondly, a greater number of electroactive sites along the walls of the bamboo-carbon nanotubes (BCNTs) resulted in larger current signals and a broader dynamic range for the oxidation of DNA bases.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Electrochemical studies on the Fc + e− Fc+ (Fc = ferrocene) process have been undertaken via the oxidation of Fc and reduction of Fc+ as the hexafluorophosphate (PF6−) or tetrafluoroborate (BF4−) salts and their mixtures in three ionic liquids (ILs) (1-butyl-1-methylpyrrolidinium bis[(trifluoromethyl)sulfonyl]imide, 1-butyl-3-methylimidazolium tetrafluoroborate, and 1-butyl-3-methylimidazolium hexafluorophosphate). Data obtained at macro- and microdisk electrodes using conventional dc and Fourier-transformed large-amplitude ac (FT-ac) voltammetry reveal that diffusion coefficients for Fc and Fc+ differ significantly and are a function of the Fc and Fc+ concentration, in contrast to findings in molecular solvents with 0.1 M added supporting electrolyte media. Thus, the Faradaic currents associated with the oxidation of Fc (Fc0/+) and reduction of FcPF6 or FcBF4 (Fc+/0) when both Fc and Fc+ are simultaneously present in the ILs differ from values obtained when individual Fc and Fc+ solutions are used. The voltammetry for both the Fc0/+ and Fc+/0 processes exhibited near-Nernstian behavior at a glassy carbon macrodisk electrode and a platinum microdisk electrode, when each process was studied individually in the ILs. As expected, the reversible formal potentials (E°′) and diffusion coefficients (D) at 23 ± 1 °C were independent of the electrode material and concentration. However, when Fc and FcPF6 or FcBF4 were both present, alterations to the mass transport process occurred and apparent D values calculated for Fc and Fc+ were found to be about 25−39% and 32−42% larger, respectively, than those determined from individual solutions. The apparent value of the double layer capacitance determined by FT-ac voltammetry from individual and mixed Fc and Fc+ conditions at the GC electrode was also a function of concentration. Double layer capacitance values increased significantly with the concentration of Fc and FcPF6 or FcBF4 when species were studied individually or simultaneously, but had a larger magnitude under conditions where both species were present. Variation in the structure of the ILs and hence mobilities of the ionic species, when Fc and FcPF6 or FcBF4 are simultaneously present, is considered to be the origin of the nonadditivity of the Faradaic currents and variation in capacitance.