30 resultados para Electric apparatus and appliances

em Deakin Research Online - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

"In the pages of this booklet we have given you actual quotations from a few of the many letters which we have recived from delighted users of Electric Ranges." -- blurb.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using Actor-Network Theory (ANT), this thesis describes arguments and inducements organisations can offer other organisations to participate in Vertical IS standardisation initiatives. To develop public goods such as Vertical IS standards, a persuasive value proposition is needed to encourage participation. Without social interactions between participants, tensions may hinder the progress of standards developments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a load frequency control scheme using electric vehicles (EVs) to help thermal turbine units to provide the stability fluctuated by load demands. First, a general framework for deriving a state-space model for general power system topologies is given. Then, a detailed model of a four-area power system incorporating a smart and renewable discharged EVs system is presented. The areas within the system are interconnected via a combination of alternating current/high voltage direct current links and thyristor controlled phase shifters. Based on some recent development on functional observers, novel distributed functional observers are designed, one at each local area, to implement any given global state feedback controller. The designed observers are of reduced order and dynamically decoupled from others in contrast to conventional centralized observer (CO)-based controllers. The proposed scheme can cope better against accidental failures than those CO-based controllers. Extensive simulations and comparisons are given to show the effectiveness of the proposed control scheme.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an improved stability criterion for load frequency control (LFC) of time-delay power systems including AC/HVDC transmission links and EVs. By employing a novel refined Jensen-based inequality, an improved stability condition is derived in terms of feasible linear matrix inequalities (LMIs) which allow us to compute the maximal upper bounds of time-delay ensuring stability of the LFC scheme equipped with an embedded controller. Cases studies here are implemented for LFC scheme of a two-area power system, which is interconnected by parallel (AC/HVDC) links, with embedded proportional integral (PI) controller for discharged EVs. The relationships between the parameters of PI controller, supplementary control of HVDC links and delay margins of the LFC scheme are also discussed. As a consequence of facts, the results of delay margins can be used as a guideline to tune PI controller and set-up parameters for HVDC control.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Magnetic force microscopy (MFM) signals have recently been detected from whole pieces of mechanically exfoliated graphene and molybdenum disulfide (MoS2) nanosheets, and magnetism of the two nanomaterials was claimed based on these observations. However, non-magnetic interactions or artefacts are commonly associated with MFM signals, which make the interpretation of MFM signals not straightforward. A systematic investigation has been done to examine possible sources of the MFM signals from graphene and MoS2 nanosheets and whether the MFM signals can be correlated with magnetism. It is found that the MFM signals have significant non-magnetic contributions due to capacitive and electrostatic interactions between the nanosheets and conductive cantilever tip, as demonstrated by electric force microscopy and scanning Kevin probe microscopy analyses. In addition, the MFM signals of graphene and MoS2 nanosheets are not responsive to reversed magnetic field of the magnetic cantilever tip. Therefore, the observed MFM response is mainly from electric artefacts and not compelling enough to correlate with magnetism of graphene and MoS2 nanosheets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We and others have shown that the copper transporters ATP7A and ATP7B play a role in cellular resistance to cisdiaminedichloroplatinum (II) (CDDP).  In this study, we found that ATP7A transfection of Chinese hamster ovary  cells (CHOK1) and fibroblasts isolated from Menkes disease patients  enhanced resistance not only to CDDP but also to various anticancer drugs, such as vincristine, paclitaxel, 7-ethyl-10- hydroxy-camptothecin (SN-38),  etoposide, doxorubicin, mitoxantron, and 7-ethyl-10-[4-(1-piperidino)-1-piperidino] carbonyloxycamptothecin (CPT-11). ATP7A preferentially localized
doxorubicin fluorescence to the Golgi apparatus in contrast to the more intense nuclear staining of doxorubicin in the parental cells. Brefeldin A   partially and monensin completely altered the distribution of doxorubicin to the nuclei in the ATP7A-expressing cells. ATP7A expression also enhanced the efflux rates of doxorubicin and SN-38 from cells and increased the uptake of SN-38 in membrane vesicles. These findings strongly suggested that   ATP7A confers multidrug resistance to the cells by compartmentalizing drugs in the Golgi apparatus and by enhancing efflux of these drugs, and the trans-Golgi network has an important role of ATP7A-related drug resistance. ATP7A was expressed in 8 of 34 (23.5%) clinical colon cancer specimens but not in the adjacent normal epithelium. Using the histoculture drug response assay that is useful for the prediction of drug sensitivity of clinical cancers, ATP7A-expressing colon cancer cells were significantly more  resistant to SN-38 than ATP7Anegative cells. Thus, ATP7A confers  resistance to various anticancer agents on cancer cells and might be a good index of drug resistance in clinical colon cancers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Damaged skeletal muscle fibres are replaced with new contractile units via muscle regeneration. Regenerating muscle fibres synthesize functionally distinct isoforms of contractile and regulatory proteins but little is known of their functional properties during the regeneration process. An advantage of utilizing single muscle fibre preparations is that assessment of their function is based on the overall characteristics of the contractile apparatus and regulatory system and as such, these preparations are sensitive in revealing not only coarse, but also subtle functional differences between muscle fibres. We examined the Ca2+- and Sr2+-activated contractile characteristics of permeabilized fibres from rat fast-twitch (extensor digitorum longus) and slow-twitch (soleus) muscles at 7, 14 and 21 days following myotoxic injury, to test the hypothesis that fibres from regenerating fast and slow muscles have different functional characteristics to fibres from uninjured muscles. Regenerating muscle fibres had ∼10% of the maximal force producing capacity (Po) of control (uninjured) fibres, and an altered sensitivity to Ca2+ and Sr2+ at 7 days post-injury. Increased force production and a shift in Ca2+ sensitivity consistent with fibre maturation were observed during regeneration such that Po was restored to 36–45% of that in control fibres by 21 days, and sensitivity to Ca2+ and Sr2+ was similar to that of control (uninjured) fibres. The findings support the hypothesis that regenerating muscle fibres have different contractile activation characteristics compared with mature fibres, and that they adopt properties of mature fast- or slow-twitch muscle fibres in a progressive manner as the regeneration process is completed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the design and numerical simulation of a T-shape microfluidic electroosmotic micromixer. It is equipped with six microelectrodes that are embedded in the side surfaces of the microchannel. The electrode array consists of two sets of three 20 ¿m and 60 ¿m microelectrodes arranged in the form of two opposing triangles. Numerical analysis of electric potential and frequency effects on mixing efficiency of the micromixer is carried out by means of two sets of simulations. First, the electric potential is kept at 2 V while the frequency is varied within 10-50 Hz. The highest achieved mixing efficiency is 96% at 22 Hz. Next, the frequency is kept at 30 Hz whilst the electric potential is varied within 1-5 V. The best achieved mixing efficiency is 97% at 3 V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hybrid electric vehicles are powered by an electric system and an internal combustion engine. The components of a hybrid electric vehicle need to be coordinated in an optimal manner to deliver the desired performance. This paper presents an approach based on direct method for optimal power management in hybrid electric vehicles with inequality constraints. The approach consists of reducing the optimal control problem to a set of algebraic equations by approximating the state variable which is the energy of electric storage, and the control variable which is the power of fuel consumption. This approximation uses orthogonal functions with unknown coefficients. In addition, the inequality constraints are converted to equal constraints. The advantage of the developed method is that its computational complexity is less than that of dynamic and non-linear programming approaches. Also, to use dynamic or non-linear programming, the problem should be discretized resulting in the loss of optimization accuracy. The propsed method, on the other hand, does not require the discretization of the problem producing more accurate results. An example is solved to demonstrate the accuracy of the proposed approach. The results of Haar wavelets, and Chebyshev and Legendre polynomials are presented and discussed. © 2011 The Korean Society of Automotive Engineers and Springer-Verlag Berlin Heidelberg.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The report shows that Australians generally have good health and are privileged to have a range of health care services available to them. There are stark exceptions to this that can be confronting—even if well-known already—notably the generally much poorer health status of Indigenous Australians.

Health care service provider and funding arrangements are both increasingly complex and increasingly costly to both individuals and taxpayers. A continuing challenge is how to balance both the complementary and competitive perspectives of government and non-government agencies, professional groups, and small businesses. Overall, national expenditure on health was 9.7% of GDP in 2003–04; and average health expenditure per person has grown by an average 3.8% each year between 1997–98 to 2002–03. Expenditure on aids and appliances, health research and pharmaceuticals contributed more to this growth than other areas.

While the ageing of the population is having a significant impact on the number and type of health care services delivered, high quality services for children continue to be a priority. Australia’s health 2006 has a special chapter focusing on children and their health. The chapter highlights the fact that while our children are generally very healthy, there are concerns that their ongoing health could be affected by more and more of them becoming overweight or obese. Levels of diabetes are now rising among our children and it is a continuing concern that asthma and mental health problems affect so many of them.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Exploring high performance cathode materials is essential to realize the adoption of Li-ion batteries for application in electric vehicles and hybrid electric vehicles. FeF3, as a typical iron-based fluoride, has been attracting considerable interest due to both the high electromotive force value of 2.7 V and the high theoretical capacity of 237 mA h g_1 (1e_ transfer). In this study, we report a facile lowtemperature solution phase approach for synthesis of uniform iron fluoride nanocrystals on reduced graphene sheets stably suspended in ethanol solution. The resulting hybrid of iron fluoride nanocrystals and graphene sheets showed high specific capacity and high rate performance for iron fluoride type cathode materials. High stable specific capacity of about 210 mA h g_1 at a current density of 0.2 C was achieved, which is much higher than that of LiFePO4 cathode material. Notably, these iron fluoride/ nanocomposite cathode materials demonstrated superior rate capability, with discharge capacities of 176, 145 and 113 mA h g_1 at 1, 2 and 5 C, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a brief review of major techniques applied in carbon dioxide corrosion testing and monitoring. The focus is on the advantages and disadvantages of variously designed testing apparatus and monitoring devices for localized corrosion detection and assessment. Critical factors affecting the reliability and accuracy of major corrosion testing techniques are briefly discussed. It is concluded that major reasons that lead to reporting of inaccurate corrosion rates and patterns include: (i) limitations in conventional electrochemical and nonelectrochemical methods for localized corrosion measurements, and difficulties in data interpretation; (ii) challenges in simulating localized corrosion mechanisms and their changes with the extension of corrosion testing. Underdeposit corrosion testing is presented as a case to illustrate challenges in simulating localized corrosion processes and mechanisms. Experiment data have been presented to show potential difficulties of the artificial pit electrode method in evaluating underdeposit corrosion and its inhibitors. The wire beam electrode method has been used to study underdeposit corrosion with and without inhibitor present. Several interesting corrosion mechanisms have been revealed at different stages of underdeposit corrosion processes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study is to design a low-cost planar Archimedean dipole antenna for batteryless transcranial direct current stimulation devices. The antenna parameters including resonance frequency, radiation efficiency, radiation pattern, and gain are simulated using finite difference time domain based electromagnetic simulation software XFdtd. The proposed antenna is simulated with low-cost FR4 PCB substrate of thickness of 1.6 mm. The antenna is designed with half wavelength of resonant frequency and fed with a matching line. The target frequency band is the industrial, scientific and medical (ISM) band of 915 MHz which is in the simulated band width of 31 MHz (903-934MHz). Moreover, since the bio-effect of specific absorption rate by radio frequency electromagnetic wave for power harvesting is an important concern, we try to find out the safety limit. Thus a quantitative analysis of distributions of electric field and power absorption in anatomical human head model by the far field radio frequency energy received by our designed antenna has been presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents systematic studies on aligning carbon nanofillers in epoxy by external fields, either electric fields or magnetic fields, to create nanocomposites with greatly improved mechanical and electrical properties. Carbon nanofibers (CNFs) and graphene nanoplatelets (GnPs) were observed to align along the field direction in the epoxy resin. Compared to the unmodifed epoxy and those with randomly-oriented carbon nanofillers, the nanocomposites with aligned carbon nanofillers showed significantly higher fracture toughness and electrical conductivity along the direction of the external field. Compared with randomly-oriented nanofillers, aligned GnPs and CNFs produced 40% and 27% improvement in fracture energy at 1.0 wt%, bringing the total increase in fracture energy over the neat polymer to more than 10 times. Several key toughening mechanisms were identified through fractographic analysis, which was used to develop predictive models to quantify the increases in the value of GIc as a result of 1-D and 2D carbon nanofillers. The present findings suggest that aligning carbon nanofillers presents a very promising technique to create multi-scale reinforcement with greatly increased electric conductivity and fracture toughness.