42 resultados para Constant-pressure conditions

em Deakin Research Online - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using a column packed with fully porous particles, four methods for controlling the flow rates at which gradient elution runs are conducted in very high pressure liquid chromatography (VHPLC) were tested to determine whether reproducible thermal conditions could be achieved, such that subsequent analyses would proceed at nearly the same initial temperature. In VHPLC high flow rates are achieved, producing fast analyses but requiring high inlet pressures. The combination of high flow rates and high inlet pressures generates local heat, leading to temperature changes in the column. Usually in this case a post-run time is input into the analytical method to allow the return of the column temperature to its initial state. An alternative strategy involves operating the column without a post-run equilibration period and maintaining constant temperature variations for subsequent analysis after conducting one or a few separations to bring the column to a reproducible starting temperature. A liquid chromatography instrument equipped with a pressure controller was used to perform constant pressure and constant flow rate VHPLC separations. Six replicate gradient separations of a nine component mixture consisting of acetophenone, propiophenone, butyrophenone, valerophenone, hexanophenone, heptanophenone, octanophenone, benzophenone, and acetanilide dissolved in water/acetonitrile (65:35, v/v) were performed under various experimental conditions: constant flow rate, two sets of constant pressure, and constant pressure operation with a programmed flow rate. The relative standard deviations of the response factors for all the analytes are lower than 5% across the methods. Programming the flow rate to maintain a fairly constant pressure instead of using instrument controlled constant pressure improves the reproducibility of the retention times by a factor of 5, when plotting the chromatograms in time.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper investigates the temperature and contact pressure conditions in hot stamped channels of boron steel. Hot stamping has been used for many years to produce high strength structural auto-motive components. The high tensile strengths achievable by hot stamping is beneficial where the intrusion during a vehicle crash is not desirable – e.g. for the vehicle occupant compartment. How-ever, the high blank temperatures and high temperature cycling causes a large amount of wear in the tooling. These conditions have led to high tool failures and die maintenance costs. Thus, un-derstanding the main causes of wear behaviour in the hot stamping process is of high interest to hot stampers.
To this aim, a generic 2D thermo-mechanical finite element model of a hat-shaped crash formed hot stamped component was developed (based on the authors previous hot stamp model), and a modified phase transformation model based on Scheil’s additive principle has been applied. The model was created in the finite element software ABAQUS Standard V6.13, including convection and radiation when the component was transferred from furnace to the tool as well as the air-cooling process. A USDFLD subroutine was used to model the phase transformation and a HET-VAL subroutine was used to model the latent heat. Contact heat conductance was a function of the pressure.
The authors have used techniques from their previous work on tool wear estimation for cold stamping to estimate the contact pressure on the tooling, and the amount of sliding that occurs over the tooling, and the corresponding tooling temperature. This data provides a unique data set to understand the wear on the tooling, and will eventually lead to a model for estimating tooling life.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pharmaceutical benefits provide a stable framework within which consumers, prescribers, suppliers, pharmacists and other actors undertake transactions. The state in effect delivers a good that enhances individual autonomy. A major reason for the legitimacy enjoyed by pharmaceutical benefits in both Australia and Sweden is that these programs have strong attributes of universalism (rather than targeting). Sweden's predominantly public health system allows greater scope for pharmaceutical policy innovation. Australia's Pharmaceutical Benefits Scheme (PBS), while historically resilient and effective, is now wedged precariously between traditional considerations of equity and public health on the one hand, and constant pressure for increased marketisation on the other.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Australian healthcare system underwent radical reform in the 1990s as economic rationalist policies were embraced. As a result, there was significant organisational restructuring within hospitals. Traditional indicators, such as nursing absenteeism and attrition, increase during times of organisational change. Despite this, nurses' views of healthcare reform are under-represented in the literature and little is known about the impact of organisational restructuring on perceived performance. This study investigated the perceived impact of organisational restructuring on a group of intensive care unit (ICU) nurses' workplace performance. It employed a qualitative approach to collect data from a purposive sample of clinical nurses. The primary method of data collection was semi-structured interviews. Content analysis generated three categories of data. Participants identified constant pressure, inadequate communication and organisational components of restructuring within the hospital as issues that had a significant impact on their workplace performance. They perceived organisational restructuring was poorly communicated, and this resulted in an environment of constant pressure. Organisational components of restructuring included the subcategories of specialised service provision and an alternative administrative structure that had both positive and negative ramifications for performance.
To date, there has been little investigation of nurses' perceptions of organisational restructure or the impact this type of change has in the clinical domain. Participants in this study believed reorganisation was detrimental to quality care delivery in intensive care, as a result of fiscal constraint, inadequate communication and pressure that influenced their workplace performance.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

One of the major challenges of MIS activities is the difficulty in measuring the effectiveness of delivered systems. The principal purpose of my research is to explore this field in order to develop an instrument by which to measure such effectiveness. Conceptualisation of Information System (IS) Effectiveness has been substantially framed by DeLone and McLean's (1992) Success; Model. But with the innovation in Information Technology (IT) over the past decade, and the constant pressure in IT to improve performance, there is merit in undertaking a fresh appraisal of the issue. This study built on the model of IS Success developed by DeLone and MeLean, but was broadened to include related research from the domains of IS, Management and Marketing. This analysis found that an effective IS function is built on three pillars: the systems implemented; the information held and delivered by these systems; and, the service provided in support of the IS function. A common foundation for these pillars is the concept of stakeholder needs. In seeking to appreciate the effectiveness: of delivered IS applications in relation to the job performance of stakeholders, this research developed an understanding of what quality means in an IT context I argue that quality is a more useful criterion for effectiveness than the more customary measures of use and user satisfaction. Respecification of the IS Success Model was then proposed. The second phase of the research was to test this model empirically through judgment panels, focus groups and interviews. Results consistently supported the structure and components of the respecified model. Quality was determined as a multi-dimensional construct, with the key dimensions for the quality of delivered IS differing from those used in the research from other disciplines. Empirical work indicated that end-user stakeholders derived their evaluations of quality by internally evaluating perceived performance of delivered IS in relation to their expectations for such performance. A short trial explored whether, when overt measurement of expectations was concurrent with the measurement of perceptions, a more revealing appraisal of delivered IS quality was provided than when perceptions alone were measured. Results revealed a difference between the two measures. Using the New IS Success Model as the foundation, and drawing upon the related theoretical and empirical research, an instrument was developed to measure the quality/effectiveness of delivered IS applications. Four trials of this instrument, QUALIT, are documented. Analysis of results from preliminary trials indicates promise in terms of business value: the instrument is simple to administer and has the capacity to pinpoint areas of weakness. The research related to the respecification of the New IS Success Model and the associated empirical studies, including the development of QTJALIT, have both contributed to the development of theory about IS Effectiveness. More precisely, my research has reviewed the components of an information system, the dimensions comprising these components and the indicators of each, and based upon these findings, formulated an instrument by which to measure the effectiveness of a delivered IS.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction
Angiotensin II (Ang II) is known to induce cardiac growth and modulate myocardial contractility. It has been reported that elevated levels of endogenous Ang II contribute to the development of cardiac hypertrophy in hypertensives. However, the long-term functional effects of cardiac exposure to Ang II in normotensives is unclear.

A recently developed transgenic mouse (TG1306/1R), in which cardiac-specific overproduction of Ang II produces primary hypertrophy, provides a new experimental model for investigation of this phenotype. The aim of the present study was to use this model to investigate whether there is a functional deficit in primary hypertrophy that may predispose to cardiac failure and sudden death. We hypothesised that primary cardiac hypertrophy is associated with mechanical dysfunction in the basal state.

Methods
Normotensive heterozygous TG1306/1R mice harbouring multiple copies of a cardiac-specific rat angiotensinogen gene were studied at age 30—40 weeks and compared with age-matched wild-type littermates. Left ventricular function was measured ex vivo in bicarbonate buffer-perfused, Langendorffmounted hearts ( at a perfusion pressure of 80 mmHg, 37°C) using a fluid-filled PVC balloon interfaced to a pressure transducer and digital data acquisition system.

Results
There was no difference in the mean (±SEM) intrinsic heart rate of TG1306/1R and wild-type control mice (357.4±11.8 vs. 367.5±20.9 bpm, n=9 & 7). Under standardised end-diastolic pressure conditions, TG1306/1R hearts exhibited a significant reduction in peak developed pressure (132.2±9.4 vs. 161.5±3.1 mmHg, n=9 & 7, p<0.05) and maximum rate of pressure development (3566.7±323.7 vs. 4486.3±109.4 mmHg, n=9 & 7, p<0.05). TG1306/1R mice show a significant correlation between incidence of arrhythmia and increasing heart size (Spearman's correlation coefficient 0.61).

Conclusion
These data demonstrate that chronic in vivo exposure to elevated levels of intra-cardiac Ang II is associated with significant contractile abnormalities evident in the ex vivo intact heart. Our findings suggest that endogenous overproduction of cardiac Ang II, independent of changes in blood pressure, is sufficient to induce ventricular remodelling that culminates in impaired cardiac function which may precede failure.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Due to ever increasing demands on lubricants, such as increased service intervals, reduced volumes and reduced emissions, there is a need to develop new lubricants and improved wear additives. Ionic liquids (ILs) are room temperature molten salts that have recently been shown to offer many advantages in this area. The application of ILs as lubricants in a diverse range of systems has found that these materials can show remarkable protection against wear and significantly reduce friction in the neat state. Recently, some researchers have shown that a small family of ILs can also be incorporated into non-polar base oils, replacing traditional anti-wear additives, with excellent performance of the neat IL being maintained. ILs consist of large asymmetrical ions that may readily adsorb onto a metal surface and produce a thin, protective film under boundary lubrication conditions. Under extreme pressure conditions, certain IL compounds can also react to form a protective tribofilm, in particular when fluorine, phosphorus or boron atoms are present in the constituent ions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nanoporous titania nanoparticles (NTNs) were synthesized and used as an additive at a low concentration of 0.1-1 wt % in the fabrication of poly(ethersulfone) (PES) ultrafiltration membranes via non-solvent-induced phase separation. The structure and properties of nanoparticles were characterized using nitrogen sorption, X-ray diffraction, scanning electron microscopy, and transmission electron microscopy. The NTNs have a size distribution with a particle size of mainly <100 nm and have a Brunauer, Emmett, and Teller surface area of ∼100 m2 g-1. The modified membranes were fabricated and investigated in terms of their pure water flux, solute rejection, and fouling resistance. The water permeability and molecular weight cutoffs (MWCOs) of membranes were determined under constant-pressure filtration in dead-end mode at 100 kPa. The membrane fouling resistance was characterized under constant flux operation using bovine serum albumin as a model foulant. The membranes were characterized in terms of morphology, porosity, pore size distribution, energy-dispersive X-ray spectroscopy, contact angle goniometry, surface free energy, and viscosity of the dope solution. Overall, the modified membrane showed increased wettability and reduced surface free energy and pore size. The modified UF membrane with 0.5 wt % NTN loading exhibited improved fouling resistance (fouling rate of 0.58 kPa/min compared to a rate of 0.70 kPa/min for the control membrane) with ∼80% water flux recovery. The same membrane showed an ∼20% increase in water flux, an improvement in MWCO, and a narrower pore size distribution.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

To quantify the frictional behaviour in sheet forming operations, several laboratory experiments which simulate the real forming conditions are performed. The Bending Under Tension Test is one such experiment which is often used to represent the frictional flow of sheet material around a die or a punch radius. Different mathematical representations are used to determine the coefficient of friction in the Bending Under Tension Test. In general the change in the strip thickness in passing over the die radius is neglected and the radius of curvature to thickness ratio is assumed to be constant in these equations. However, the effect of roller radius, sheet thickness and the surface pressure are also omitted in some of these equations. This work quantitatively determined the effect of roller radius and the tooling pressure on the coefficient of friction. The Bending Under Tension Test was performed using rollers with different radii and also lubricants with different properties. The tool radii were found to have a direct influence in the contact pressure. The effect of roller radius on friction was considerable and it was observed that there is a clear relationship between the contact pressure and the coefficient of friction.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Counter-pressure was used to extend the duration of field-amplified sample injection in isotachophoresis (FASI-ITP) in order to improve the detection of bacterial cells. Using 0.51-μm negatively charged encapsulated fluorescent beads as a model, the counter-pressure, injection and separation voltages, and times were optimized. Using 6-min 8,963-Pa counter-pressure FASI-ITP injections at −12 kV followed by mobilization of the ITP band with continued injection at −6 kV, the limit of detection (LOD) for Escherichia coli was improved to 78 cells/mL, a factor of 4 when compared with FASI-ITP without counter-pressure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The quality of high pressure die castings is a function of many interdependent parameters. It has been observed that many defects detected in the HPDC castings can be tracked back to poor die temperature distribution in the critical areas. It has therefore been recommended that the development of a technique to directly control the critical features - making them less sensitive to thermal related parameters - be very beneficial to the HPDC industry. From the information obtained from thermal image (processing), computational fluid dynamics has been applied to design the layout of internal cooling system and assign the flow conditions such as flow rate and pressure of the cooling water. it is observed that CFD prediction provides an excellent insight into the thermal balance of the high pressure die casting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We attempt to generate new solutions for the moisture content form of the one-dimensional Richards' [1931] equation using the Lisle [1992] equivalence mapping. This mapping is used as no more general set of transformations exists for mapping the one-dimensional Richards' equation into itself. Starting from a given solution, the mapping has the potential to generate an infinite number of new solutions for a series of nonlinear diffusivity and hydraulic conductivity functions. We first seek new analytical solutions satisfying Richards' equation subject to a constant flux surface boundary condition for a semi-infinite dry soil, starting with the Burgers model. The first iteration produces an existing solution, while subsequent iterations are shown to endlessly reproduce this same solution. Next, we briefly consider the problem of redistribution in a finite-length soil. In this case, Lisle's equivalence mapping is generalized to account for arbitrary initial conditions. As was the case for infiltration, however, it is found that new analytical solutions are not generated using the equivalence mapping, although existing solutions are recovered.