15 resultados para ATOMIC-FORCE MICROSCOPE

em Deakin Research Online - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The double layer structure of two ionic liquids (ILs), 1-butyl-1- methylpyrrolidinium tris(pentafluoroethyl)trifluorophosphate ([Py 1,4]FAP) and 1-ethyl-3-methylimidazolium tris(pentafluoroethyl) trifluorophosphate ([EMIm]FAP) at the polarized Au(111) electrode interface is probed using Atomic Force Microscopy force measurements. The force-separation profiles suggest a multilayered morphology is present at the electrified Au(111)-IL interface, with more near surface layers detected at higher potentials. At the (slightly negative) open circuit potential, multiple ion layers are present, and the innermost layer, in contact with the Au(111) surface, is enriched in the cation due to electrostatic adsorption. Upon applying negative electrode potentials (-1.0 V, -2.0 V), stronger IL near surface structure is detected: both the number of ion layers and the force required to rupture these layers increases. Positive electrode potentials (+1.0 V, +2.0 V) also enhance IL near surface structure, but not as much as negative potentials, because surface-adsorbed anions are less effective at templating structure in subsequent layers than cations. This interfacial structure is not consistent with a double layer in the Stern-Gouy-Chapman sense, as there is no diffuse layer. The structure is consistent with a capicitative double-layer model, with a very small separation distance between the planes of charge.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Current advancements in nanotechnology are dependent on the capabilities that can enable nano-scientists to extend their eyes and hands into the nano-world. For this purpose, a haptics (devices capable of recreating tactile or force sensations) based system for AFM (Atomic Force Microscope) is proposed. The system enables the nano-scientists to touch and feel the sample surfaces, viewed through AFM, in order to provide them with better understanding of the physical properties of the surface, such as roughness, stiffness and shape of molecular architecture. At this stage, the proposed work uses of ine images produced using AFM and perform image analysis to create virtual surfaces suitable for haptics force analysis. The research work is in the process of extension from of ine to online process where interaction will be done directly on the material surface for realistic analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An atomic force microscope was used to measure the forces acting between two polystyrene latex spheres in aqueous media. The results show an electrostatic repulsion at large separations which is overtaken by an attractive “hook” that pulls the two spheres into contact from a considerable range (20−400 nm), much larger than could be expected for a van der Waals attraction. The range of operation of this attraction varies from one experiment to another and is not correlated with electrolyte concentration. However, the range is found to decrease significantly when the level of dissolved gas in the water is reduced.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A model developed previously to analyze force measurements between two deformable droplets in the atomic force microscope [Langmuir 2005, 21, 2912-2922] is used to model the drainage of an aqueous film between a mica plate and a deformable mercury drop for both repulsive and attractive electrical double-layer interactions between the mica and the mercury. The predictions of the model are compared with previously published data [Faraday Discuss. 2003, 123, 193-206] on the evolution of the aqueous film whose thickness has been measured with subnanometer precision. Excellent agreement is found between theoretical results and experimental data. This supports the assumptions made in the model which include no-slip boundary conditions at both interfaces. Furthermore, the successful fit attests to the utility of the model as a tool to explore details of the drainage mechanisms of nanometer-thick films in which fluid flow, surface deformations, and colloidal forces are all involved. One interesting result is that the model can predict the time at which the aqueous film collapses when attractive mica-mercury forces are present without the need to invoke capillary waves or other local instabilities of the mercury/electrolyte interface.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a method for single cell stiffness measurement based on a nano-needle and nanomanipulation. The nano-needle with a buffering beam was fabricated from an atomic force microscope cantilever by the focused ion beam etching technique. Wild type yeast cells (W303) were prepared and placed on the sample stage inside an environmental scanning electron microscope (ESEM) chamber. The nanomanipulator actuated the nano-needle to press against a single yeast cell. As a result, the deformation of the cell and nano-needle was observed by the ESEM system in real-time. Finally, the stiffness of the single cell was determined based on this deformation information. To reveal the relationship between the cell stiffness and the environmental humidity conditions, the cell stiffness was measured at three different humidity conditions, i.e. 40, 70 and 100%, respectively. The results show that the stiffness of a single cell is reduced with increasing humidity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The performance of composite laminates depends on the adhesion between the fibre reinforcement and matrix, with the surface properties of the fibres playing a key role in determining the level of adhesion achieved. For this reason it is important to develop an in-depth understanding of the surface functionalities on the reinforcement fibres. In this work, multi-scale surface analysis of carbon fibre during the three stages of manufacture; carbonisation, electrolytic oxidation, and epoxy sizing was carried out. The surface topography was examined using scanning electron microscopy (SEM), which revealed longitudinal ridges and striations along the fibre-axis for all fibre types. A small difference in surface roughness was observed by scanning probe microscopy (SPM), while the coefficient of friction measured by an automated single fibre tester showed 51% and 98% increase for the oxidised and sized fibres, respectively. The fibres were found to exhibit heterogeneity in surface energy as evidenced from SPM force measurements. The unsized fibres were much more energetically heterogeneous than the sized fibre. A good correlation was found between fibre properties (both physical and chemical) and interlaminar shear strength (ILSS) of composites made from all three fibre types. © 2014 Elsevier Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The remarkable physical properties of ionic liquids (ILs) make them potentially excellent lubricants. One of the challenges for using ILs as lubricants is their high cost. In this article, atomic force microscopy (AFM) nanotribology measurements reveal that a 1 mol % solution of IL dissolved in an oil lubricates the silica surface as effectively as the pure IL. The adsorption isotherm shows that the IL surface excess need only be approximately half of the saturation value to prevent surface contact and effectively lubricate the sliding surfaces. Using ILs in this way makes them viable for large-scale applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel tri-block copolymer poly(oxopentanoate ethyl methacrylate)-block-poly(pyridyl disulfide ethyl acrylate)-block-poly(ethylene glycol acrylate) [poly(OEMA-b-PDEA-b-PEGA)], retaining active keto groups and pyridyl disulfide (PDS) side functionalities, was synthesized as a drug delivery vehicle using reversible addition-fragmentation chain transfer (RAFT) polymerization method. One mimic drug pyridine-2-thione (PT) was introduced into the monomer, PDEA for copolymerization. The other mimic drug O-benzylhydroxylamine (BHA) was conjugated with tri-block copolymer via efficient oxime coupling chemistry, followed by the attachment onto graphene via π-π stacking interaction to obtain a graphene/tri-block copolymer composite. 1H NMR, UV-vis absorption spectroscopy, fluorescence spectroscopy, gel permeation chromatography (GPC), atomic force microscope (AFM) and transmission electron microscope (TEM) were used to verify the successful step-wise preparation of the tri-block copolymer and drug loaded composite. In vitro release behaviors of BHA and PT from graphene/tri-block copolymer composite via dual drug release mechanisms were investigated. BHA can be released under acid environment, while PT will be released in the presence of reducing agents, such as dithiothreitol (DTT) or glutathione (GSH). It can be envisioned that this novel composite could be exploited as a novel intracellular drug delivery system via dual release mechanisms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

© 2015 Elsevier Ltd. All rights reserved. Most researches on graphene/polymer composites are focusing on improving the mechanical and electrical properties of polymers at low graphene content instead of paying attention to constructing graphene's macroscopic structures. In current study the homo-telechelic functionalized polyethylene glycols (FPEGs) were tailored with π-orbital-rich groups (namely phenyl, pyrene and di-pyrene) via esterification reactions, which enhanced the interaction between polyethylene glycol (PEG) molecules and chemical reduced graphene oxide (RGO) sheets. The π-π stacking interactions between graphene sheets and π-orbital-rich groups endowed the composite films with enhanced tensile strength and tunable electrical conductivity. The formation of graphene network structure mediated by the FPEGs fillers via π-π stacking non-covalent interactions should account for the experimental results. The experimental investigations were also complemented with theoretical calculation using a density functional theory. Atomic force microscope (AFM), scanning electron microscope (SEM), X-ray diffraction (XRD), nuclear magnetic resonance (NMR), thermal gravimetric analysis (TGA), UV-vis and fluorescence spectroscopy were used to monitor the step-wise preparation of graphene composite films.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An improved method for mass production of good-quality graphene nanosheets (GNs) via ball milling pristine graphite with dry ice is presented. We also report the enhanced performance of these GNs as working electrode in lithium-ion batteries (LIBs). In this improved method, the decrease of necessary ball milling time from 48 to 24 h and the increase of Brunauer–Emmett–Teller surface area from 389.4 to 490 m2/g might be resulted from the proper mixing of stainless steel balls with different diameters and the optimization of agitation speed. The as-prepared GNs are investigated in detail using a number of techniques, such as scanning electron microscope, atomic force microscope, high-resolution transmission electron microscopy, selected area electron diffraction, X-ray diffractometer, and Fourier transform infrared spectroscopic. To demonstrate the potential applications of these GNs, the performances of the LIBs with pure Fe3O4 electrode and Fe3O4/graphene (Fe3O4/G) composite electrode were carefully evaluated. Compared to Fe3O4-LIBs, Fe3O4/G-LIBs exhibited prominently enhanced performance and a reversible specific capacity of 900 mAh g−1 after 5 cycles at 100 and 490 mAh g−1 after 5 cycles at 800 mA g−1. The improved cyclic stability and enhanced rate capability were also obtained.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

'Torayca' T800H/3900-2 is the first material qualified on Boeing Material Specification (BMS 8-276) which utilizes the thermoplastic-particulate interlayer toughening technology. Two manufacturing processes, the autoclave process and the fast heating rated Quickstep™ process, were employed to cure this material. The Quickstep process is a unique composite production technology which utilizes the fast heat transfer rate of fluid to heat and cure polymer composite components. The manufacturing influence on the mode I delamination fracture toughness of laminates was investigated by performing double cantilever beam tests. The composite specimens fabricated by two processes exhibited dissimilar delamination resistance curves (R-curves) under mode I loading. The initial value of fracture toughness GIC-INIT was 564 J/m2 for the autoclave specimens and 527 J/m2 for the Quickstep specimens. However, the average propagation fracture toughness GIC-PROP was 783 J/m2 for the Quickstep specimens, which was 2.6 times of that for the autoclave specimens. The mechanism of fracture occurred during delamination was studied under scanning electron microscope (SEM). Three types of fracture were observed: the interlayer fracture, the interface fracture, and the intralaminar fracture. These three types of fracture played different roles in affecting the delamination resistance curves during the crack growth. More fiber bridging was found in the process of delamination for the Quickstep specimens. Better fiber/matrix adhesion was found in the Quickstep specimens by conducting indentation-debond tests.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The application of surface force apparatus (SFA) capabilities in measuring interactions between surfaces over nanometer separations was described. The technique is used when both the materials are transparent. It was observed that the poorly reflecting surface produce fringes that have low contrast and low finesse. The results show that the technique is successful when the visibility of the interference fringes is maximized.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Technologies, such as Atomic Force Microscopy (AFM), have proven to be one of the most versatile research equipments in the field of nanotechnology by providing physical access to the materials at nanoscale. Working principles of AFM involve physical interaction with the sample at nanometre scale to estimate the topography of the sample surface. Size of the cantilever tip, within the range of few nanometres diameter, and inherent elasticity of the cantilever allow it to bend in response to the changes in the sample surface leading to accurate estimation of the sample topography. Despite the capabilities of the AFM, there is a lack of intuitive user interfaces that could allow interaction with the materials at nanoscale, analogous to the way we are accustomed to at macro level. To bridge this gap of intuitive interface design and development, a haptics interface is designed in conjunction with Bruker Nanos AFM. Interaction with the materials at nanoscale is characterised by estimating the forces experienced by the cantilever tip employing geometric deformation principles. Estimated forces are reflected to the user, in a controlled manner, through haptics interface. Established mathematical framework for force estimation can be adopted for AFM operations in air as well as in liquid mediums.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Herein, a uniform three-dimensional (3-D) graphene nanodots-encaged porous gold electrode was prepared via ion beam sputtering deposition (IBSD) and mild corrosion chemistry for efficient enzyme electrode fabrication. Enzymes, like glucose oxidase and catalase, were modified with pyrene functionalities and then loaded into the graphene nanodots encaged porous gold electrode via non-covalent π-π stacking interaction between pyrene and graphene. The fabricated enzyme electrodes showed profound reusability and repeatability, high sensitivity, inherent selectivity and enhanced detection range. As for glucose analysis a broad linear range from 0.05 to 100 mM was obtained and the linear range for hydrogen peroxide was 0.005 to 4 mM. Detection limits of 30 μM for glucose and 1 μM for hydrogen peroxide were achieved (S/N = 3), respectively. These electrodes can be applied to analyze the clinical samples with reliable results. The formation mechanism and 3-D structure of the porous electrode were investigated using high resolution transmission electron microscope (HRTEM), atomic force microscopy (AFM), scanning electron microscope (SEM) and electrochemical impedance spectroscopy (EIS). Most importantly, various other ideal biosensors can be fabricated using the same porous electrode and the same enzyme modification methodology.