82 resultados para Power system stability


Relevância:

90.00% 90.00%

Publicador:

Resumo:

A novel algorithm, immune genetic algorithm (IGA) is proposed for reactive power optimization of power system. While retaining excellent characteristics of genetic algorithm (GA), through imitating the biological immune system, the algorithm evaluates and selects the optimal solutions by the affinities between antigens and antibodies. With the regulation of the activating and suppressing of antibodies, IGA can achieve the dynamic balance between individual diversity and population convergence, and avoid getting into the local optimal solution. The proposed IGA is applied to the IEEE 30-bus system, and the results show that it is superior to the GA with good population convergence and fast computing speed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Artificial neural networks have a good potential to be employed for fault diagnosis and condition monitoring problems in complex processes. In this paper, the applicability of the fuzzy ARTMAP (FAM) neural network as an intelligent learning system for fault detection and diagnosis in a power generation plant is described. The process under scrutiny is the circulating water (CW) system, with specific attention to the conditions of heat transfer and tube blockage in the CW system. A series of experiments has been conducted systematically to investigate the effectiveness of FAM in fault detection and diagnosis tasks. In addition, a set of domain rules has been extracted from the trained FAM network so that its predictions can be explained and justified. The outcomes demonstrate the benefits of employing FAM as an intelligent fault detection and diagnosis tool with an explanatory capability for monitoring and diagnosing complex processes in power generation plants.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study mainly focuses on the terminal sliding mode control (TSMC) strategy design, including an adaptive terminal sliding mode control (ATSMC) and an exact-estimator-based terminal sliding mode control (ETSMC) for second-order nonlinear dynamical systems. In the ATSMC system, an adaptive bound estimation for the lump uncertainty is proposed to ensure the system stability. On the other hand, an exact estimator is designed for exact estimating system uncertainties to solve the trouble of chattering phenomena caused by a sign function in ATSMC law in despite of the utilization of a fixed value or an adaptive tuning algorithm for the lumped uncertainty bound. The effectiveness of the proposed control schemes can be verified in numerical simulations.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

All over the world, electrical power systems are encountering radical change stimulated by the urgent need to decarbonize electricity supply, to swap aging resources and to make effective application of swiftly evolving information and communication technologies (ICTs). All of these goals converge toward one direction; ‘Smart Grid.’ The Smart Grid can be described as the transparent, seamless, and instantaneous two-way delivery of energy information, enabling the electricity industry to better manage energy delivery and transmission and empowering consumers to have more control over energy decisions. Basically, the vision of Smart Grid is to provide much better visibility to lower-voltage networks as well as to permit the involvement of consumers in the function of the power system, mostly through smart meters and Smart Homes. A Smart Grid incorporates the features of advanced ICTs to convey real-time information and facilitate the almost instantaneous stability of supply and demand on the electrical grid. The operational data collected by Smart Grid and its sub-systems will allow system operators to quickly recognize the best line of attack to protect against attacks, susceptibility, and so on, sourced by a variety of incidents. However, Smart Grid initially depends upon knowing and researching key performance components and developing the proper education program to equip current and future workforce with the knowledge and skills for exploitation of this greatly advanced system. The aim of this chapter is to provide a basic discussion of the Smart Grid concept, evolution and components of Smart Grid, environmental impacts of Smart Grid and then in some detail, to describe the technologies that are required for its realization. Even though the Smart Grid concept is not yet fully defined, the chapter will be helpful in describing the key enabling technologies and thus allowing the reader to play a part in the debate over the future of the Smart Grid. The chapter concludes with the experimental description and results of developing a hybrid prediction method for solar power which is applicable to successfully implement the ‘Smart Grid.’

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This letter presents a novel approach to the load-frequency control (LFC) of interconnected power systems. Based on functional observers theory, quasi-decentralized functional observers (QDFOs) are designed to implement any given global PI state feedback controller. The designed functional observers are decoupled from each other and also of low-order; thus, they are cost effective and easy to implement. Although the proposed approach is applicable to N- area power systems, an example of a two-area interconnected power system with reheat thermal turbines is considered for simplicity.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The phenomenal growth in economy experienced in developed countries throughout the 20th century has largely been driven by the availability of conventional energy sources for electricity generation. However, increased concern about fossil fuels and adverse effect of carbon dioxide emission in to atmosphere changed the conventional power system to a viable one by integrating renewable energy sources into the existing system. Among the Renewable Energy (RE) sources, wind energy is one of the fastest growing technologies in reducing the Green House Gas (GHG) emissions in to the atmosphere due to its continuous availability throughout a period. Hence, this paper discusses the performance of a wind-grid connected system in a semi-arid region by conducting a case study. Wilson promontory, one of the best locations for wind generation in Victoria is considered as a case study. Hybrid Optimization Model for Electric Renewable (HOMER) is used as a simulating tool for this analysis. This study also presents the influences of storage system in the proposed Hybrid Power System (HPS) allowing energy to be stored during higher generations or lower load demands. In addition this paper also discusses the major integration issues to facilitate the large scale wind energy into the grid for reliable power generation and distribution.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

n this paper, the design of a nonlinear excitation control of a synchronous generator is presented where the generator is connected to a single machine infinite bus (SMIB) system. An adaptive backstepping method is used to design the excitation controller with an objective of enhancing the overall dynamic stability of the SMIB system under different contingencies. In this paper, two types of contingencies are considered- i) unknown parameters and physical quantities during the controller design process and ii) controller performance evaluation under different system configurations such as three-phase short circuit faults. The adaption law, which is mainly based on the formulation of Lyapunov function, is used to estimate the unknown parameters which guarantee the convergence of different physical quantities of synchronous generators, e.g., the relative speed, terminal voltage, etc. The effectiveness of the proposed scheme is evaluated under different system configurations as mentioned in the second contingency and compared to that of an existing adaptive backstepping controller and a conventional power system stabilizer (PSS). Simulation results demonstrate the superiority of the proposed control scheme over the existing controllers.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Electric vehicles (EVs) have recently gained much popularity as a green alternative to fossil-fuel cars and a feasible solution to reduce air pollution in big cities. The use of EVs can also be extended as a demand response tool to support high penetration of renewable energy (RE) sources in future smart grid. Based on the certainty equivalent adaptive control (CECA) principle and a customer participation program, this paper presents a novel control strategy using optimization technique to coordinate not only the charging but also the discharging of EV batteries to deal with the intermittency in RE production. In addition, customer charging requirements and schedules are incorporated into the optimization algorithm to ensure customer satisfaction, and further improve the control performance. The merits of this scheme are its simplicity, efficiency, robustness and readiness for practical applications. The effectiveness of the proposed control algorithm is demonstrated by computer simulations of a power system with high level of wind energy integration.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This article engages one of the important gaps in the literature on party system effects: the consequences of party system change. We discuss how existing empirical approaches to party system change do not actually capture the changeability of patterns of party competition, which is the most direct understanding of the term “party system.” We propose a measure that does exactly this: the index of fluidity. Applying this measure to countries in South East Asia, we show that party system change is associated with harmful effects, including lower foreign direct investment and deterioration of the rule of law.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Over the past decade, the growing demand of Grid-connected photo voltaic (GCPV) system has been increasing due to an extensive use of renewable energy technologies for sustainable power generation and distribution. High-penetrated GCPV systems enhance the operation of the network by improving the voltage levels and reducing the active power losses along the length of the feeder. This paper aims to investigate the voltage variations and Total Harmonic Distortion (THD) of a typical GCPV system modelled in Power system simulator, PSS SINCAL with the change of level of PV integrations in a Low Voltage (LV) distribution network. Five different case studies are considered to investigate the impact of PV integrations on LV nodes and the corresponding voltage variations and harmonics. In addition, this paper also explores and benchmarks the voltage improvement techniques by implementing On Load Tap Changer (OLTC) with respective to the main transformer and addition of Shunt Capacitor (SC) at appropriate node points in LV network,

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Microgrid (MG) power system plays an important role to fulfill reliable and secure energy supply to critical loads of communities as well as for communities in remote area. Distributed Generation (DG) sources integrated in a MG provides numerous benefits, at the same time leads to power quality issues in the MG power distribution network. Power Quality (PQ) issue arises due to the integration of an intermittent nature of Renewable Energy (RE) sources with advanced Power Electronics (PE) converter technology. Also, presence of non-linear and unbalancing loads in MG seems to affect PQ of the energy supply in power distribution network. In this paper, PQ impacts like; power variation, voltage variation, Total Harmonic Distortion (THD), and Unbalance voltage level have been analysed in Low Voltage (LV) distribution network of typical MG power system model. In this study, development of MG model and PQ impact analysis through simulation has been done in PSS-Sincal software environment. Analysis results from the study can be used as a guideline for developing a real and independent MG power system with improved PQ conditions.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Integration of solar PV and wind in to the distribution network is one of the most promising challenges of the modern power system networks to meet the growing demand of energy. Analysis of the effects of solar and wind intermittencies in the network are vital to maintain the power quality. Keeping this in view, this research paper focuses on impact analysis study of a typical power network with hybrid generation: solar PV and wind integration to quantify the level of impacts like power variation and voltage variation in the network through load flow analysis. Initially, a typical network model is developed using PSS-SINCAL and load profile analysis has been carried out based on the typical daily load profile and wind/solar profile to verify the power and voltage variations extensively in the network considering different scenarios. Results of this research analysis can be used as guidelines for utility grid to provide regulated and improved quality of energy supply by implementing appropriate planning of generation reserve and other control measures in the network

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Microgrid (MG) integrated with Distributed Generation (DG) provides several benefits like reliable, secure, and high efficient of energy supply, while minimizing power loss, deferring expansion of power distribution infrastructures, and reduced carbon emission of energy supply etc. to the communities. Despite of the several benefits, there are several challenges existing due to the integration of different characteristics and technology of DG sources in MG network. Power Quality (PQ) issue is one of the main technical challenges in MG power system. In order to provide improved PQ of energy supply, it is necessary to analyse and quantify the PQ level in MG network. This paper investigates the detail of PQ impacts in a real MG network carried out through an experimental analysis. Voltage and frequency variations/deviations are analysed in both on-grid and off-grid mode of MG operation at varying generation and varying load conditions. Similarly un-balance voltage and current level in neutral are estimated at unbalanced PV generation and uneven load distribution in MG network. Also current and voltage THD are estimated at different PV power level. Finally the results obtained from the analysis are compared to that of Australian network standard level.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Wind energy system integration can lead to adverse effects on modern electric grid so it is imperative toassess their dynamic performance before actual plant startup. Transmission system operators all over theworld stress the need for a proper wind turbine generator model for dynamic performance as well asancillary service assessments. Due to the bulk power system assessment requirements, developmentof suitable generic modeling has gained high priority. Generic modeling of type 4 full converter wind turbinegenerator system for application in frequency ancillary service investigations under varying windspeed and varying reference power has been presented in this study. Prevalent generic model, manufacturerspecific proprietary generic model along with detailed wind turbine model with synchronous generatoris also provided to highlight various modelling framework difference. Descriptions of individualsub models of proposed generic model are presented in detail and performance results are comparedand validated with GE’s proprietary generic model and detailed WTG model by means of simulationsin the MATLAB Power System Block set.