276 resultados para Corrosion Pitting


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of chromate on metastable pitting of AA7075-T651 as determined via potentiostatic polarisation is reported. A systematic study of metastable pitting and its correlation with stable pits was conducted in various concentrations of sodium chromate (Na2CrO4), revealing the metastable pitting rate was able to provide a quantitative metric for pitting corrosion. The size and number of metastable pits decreased significantly in the presence of chromate. The present study is intended as a general baseline for the assessment of future chromate replacement technologies, as elaborated herein. © 2014 Elsevier Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of Fe in Al is technologically important for commercial Al-alloys, and in recycled Al. This work explores the use of the novel rapid solidification technology, known as direct strip casting, to improve the recyclability of Al-alloys. We provide a comparison between the corrosion and microstructure of Al-Fe alloys prepared with wide-ranging cooling rates (0.1. °C/s to 500. °C/s). Rapid cooling was achieved via direct strip casting, while slow cooling was achieved using sand casting. Corrosion was studied via polarisation and immersion tests, followed by surface analysis using scanning electron microscopy and optical profilometry. It was shown that the corrosion resistance of Al-Fe alloys is improved with increased cooling rates, attributed to the reduced size and number of Fe-containing intermetallics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Corrosion has significant adverse effects on the durability of reinforced concrete (RC) structures, especially those exposed to a marine environment and subjected to mechanical stress, such as bridges, jetties, piers and wharfs. Previous studies have been carried out to investigate the corrosion behaviour of steel rebar in various concrete structures, however, few studies have focused on the corrosion monitoring of RC structures that are subjected to both mechanical stress and environmental effects. This paper presents an exploratory study on the development of corrosion monitoring and detection techniques for RC structures under the combined effects of external loadings and corrosive media. Four RC beams were tested in 3% NaCl solutions under different levels of point loads. Corrosion processes occurring on steel bars under different loads and under alternative wetting - drying cycle conditions were monitored. Electrochemical and microscopic methods were utilised to measure corrosion potentials of steel bars; to monitor galvanic currents flowing between different steel bars in each beam; and to observe corrosion patterns, respectively. The results indicated that steel corrosion in RC beams was affected by local stress. The point load caused the increase of galvanic currents, corrosion rates and corrosion areas. Pitting corrosion was found to be the main form of corrosion on the surface of the steel bars for most of the beams, probably due to the local concentration of chloride ions. In addition, visual observation of the samples confirmed that the localities of corrosion were related to the locations of steel bars in beams. It was also demonstrated that electrochemical devices are useful for the detection of RC beam corrosion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mild steel infrastructure is constantly under corrosive attack in most environmental and industrial conditions. There is an ongoing search for environmentally friendly, highly effective inhibitor compounds that can provide a protective action in situations ranging from the marine environment to oil and gas pipelines. In this work an organic salt comprising a protic imidazolinium cation and a 4-hydroxycinnamate anion has been shown to produce a synergistic corrosion inhibition effect for mild steel in 0.01 M NaCl aqueous solutions under acidic, neutral, and basic conditions; an important and unusual phenomenon for one compound to support inhibition across a range of pH conditions. Significantly, the individual components of this compound do not inhibit as effectively at equivalent concentrations, particularly at pH 2. Immersion studies show the efficacy of these inhibitors in stifling corrosion as observed from optical, SEM, and profilometry experiments. The mechanism of inhibition appears to be dominated by anodic behavior where dissolution of the steel, and in particular the pitting process, is stifled. FTIR spectroscopy provides confirmation of a protective interfacial layer, with the observation of interactions between the steel surface and 4-hydroxycinnamate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of the heat treatment on the corrosion behaviour of amorphous Al88Ni6La6 made by melt-spun has been investigated by electrochemical measurements. Heat treatment was carried out at 523 K and 673 K for 4 min and 15 min respectively. The evolution of the crystallization process after annealing was identified by differential scanning calorimeter (DSC) as well as X-ray diffraction. The XRD patterns show that the structure of samples heat-treated at higher temperature changes towards a crystal state. The results obtained from the polarization curves reveal that all Al88Ni6La6 alloys exhibit spontaneously passivated behaviour. Furthermore, it is noted that the partially crystallized alloy has the best corrosion resistance in comparison with as-spun amorphous and fully crystallized alloys, while the fully crystallized sample shows deterioration in the corrosion resistance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of crystallization on the corrosion resistance of a  Cu52.5Ti30Zr11.5Ni6 bulk amorphous alloy in 1 mol/L HCl, and 6 mol/L NaOH solutions were studied. The amorphous alloy was identified by  differential thermal analysis(DSC) and by X-ray diffraction(XRD). The partially and fully crystallized alloys were prepared by controlling the annealing  temperatures at 738 and 873 K for 1 and 12 min, respectively, and the corrosion resistances of those annealed alloys were compared with that of the amorphous alloy by immersion test and potentiodynamic measurements in 1 mol/L HCl and 6 mol/L NaOH solutions. The results show that the  partially crystallized alloy exhibits high corrosion resistance, whereas full crystallization results in deteriorated corrosion resistance compared with that of the as-cast amorphous alloy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Corrosion testing (half-cell and LPR) was carried out on a number reinforced concrete panels which had been taken from the fascia of a twenty five year old high rise building in Melbourne, Australia. Corrosion, predominantly as a result of carbonation of the concrete, was associated with a limited amount of cracking. A monitoring technique was established in which probe electrodes (reference and counter) were retro-fitted into the concrete. The probe electrode setup was identical for all panels tested. It was found that the corrosion behaviour of all panels tested closely fitted a family of results when the corrosion potential is plotted against the polarisation resistance (Rp). This enabled the development of a so-called 'control curve' relating the corrosion potential to the Rp for all of the panels under investigation. This relationship was also confirmed on laboratory samples, indicating that for a fixed geometry and experimental conditions a relationship between the potential and polarisation resistance of steel can be established for the steel-concrete system. Experimental results will be presented which indicate that for a given monitoring cell geometry, it may be possible to propose criteria for the point at which remediation measures should be considered. The establishment of such a control curve has enabled the development of a powerful monitoring tool for the assessment of a number of proposed corrosion remediation techniques. The actual effect of any corrosion remediation technique becomes clearly apparent via the type and magnitude of deviation of post remediation data from the original (preremediation) control curve.