9 resultados para system comparison

em Dalarna University College Electronic Archive


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Within the aging building stock of Europe, there is great potential of saving energy through renovation and upgrading to modern standards, and to thereby approach the internationally set goals of lower energy use. This paper concerns the planned renovation of the building envelope and HVAC systems in a multi-family house in Ludwigsburg, Germany. Five systemic HVAC solutions were compared, with special focus on two systems: A) Balanced ventilation with HRC + Micro heat pump, and B) Forced exhaust ventilation + Heat pump with exhaust air HRC + Ventilation radiators. Given the predicted heating demand and ventilation rate of the house after renovation, the performance of the two systems was compared, alongside three common systems for reference. Calculations were made using TMF Energi, a tool developed by SP Technical Research Institute of Sweden.    Both systems A and B were found to have the lowest electrical energy use together with the ground source heat pump system for the assumed conditions. For other assumptions, including different climate and degree of insulation, some differences between these three systems were noted. Most significant is the increased electrical use of system B for higher heating loads due to limitations in the power available from the heat source, exhaust air, which is dependent on the ventilation rate.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this thesis the solar part of a large grid-connected photovoltaic system design has been done. The main purpose was to size and optimize the system and to present figures helping to evaluate the prospective project rationality, which can potentially be constructed on a contaminated area in Falun. The methodology consisted in PV market study and component selection, site analysis and defining suitable area for solar installation; and system configuration optimization based on PVsyst simulations and Levelized Cost of Energy calculations. The procedure was mainly divided on two parts, preliminary and detailed sizing. In the first part the objective was complex, which included the investigation of the most profitable component combination and system optimization due to tilt and row distance. It was done by simulating systems with different components and orientations, which were sized for the same 100kW inverter in order to make a fair comparison. For each simulated result a simplified LCOE calculation procedure was applied. The main results of this part show that with the price of 0.43 €/Wp thin-film modules were the most cost effective solution for the case with a great advantage over crystalline type in terms of financial attractiveness. From the results of the preliminary study it was possible to select the optimal system configuration, which was used in the detailed sizing as a starting point. In this part the PVsyst simulations were run, which included full scale system design considering near shadings created by factory buildings. Additionally, more complex procedure of LCOE calculation has been used here considered insurances, maintenance, time value of money and possible cost reduction due to the system size. Two system options were proposed in final results; both cover the same area of 66000 m2. The first one represents an ordinary South faced design with 1.1 MW nominal power, which was optimized for the highest performance. According to PVsyst simulations, this system should produce 1108 MWh/year with the initial investment of 835,000 € and 0.056 €/kWh LCOE. The second option has an alternative East-West orientation, which allows to cover 80% of occupied ground and consequently have 6.6 MW PV nominal power. The system produces 5388 MWh/year costs about 4500,000 € and delivers electricity with the same price of 0.056 €/kWh. Even though the EW solution has 20% lower specific energy production, it benefits mainly from lower relative costs for inverters, mounting and annual maintenance expenses. After analyzing the performance results, among the two alternatives none of the systems showed a clear superiority so there was no optimal system proposed. Both, South and East-West solutions have own advantages and disadvantages in terms of energy production profile, configuration, installation and maintenance. Furthermore, the uncertainty due to cost figures assumptions restricted the results veracity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this project is to update the tool of Network Traffic Recognition System (NTRS) which is proprietary software of Ericsson AB and Tsinghua University, and to implement the updated tool to finish SIP/VoIP traffic recognition. Basing on the original NTRS, I analyze the traffic recognition principal of NTRS, and redesign the structure and module of the tool according to characteristics of SIP/VoIP traffic, and then finally I program to achieve the upgrade. After the final test with our SIP data trace files in the updated system, a satisfactory result is derived. The result presents that our updated system holds a rate of recognition on a confident level in the SIP session recognition as well as the VoIP call recognition. In the comparison with the software of Wireshark, our updated system has a result which is extremely close to Wireshark’s output, and the working time is much less than Wireshark. In the aspect of practicability, the memory overflow problem is avoided, and the updated system can output the specific information of SIP/VoIP traffic recognition, such as SIP type, SIP state, VoIP state, etc. The upgrade fulfills the demand of this project.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A one year data analysis for a micro PV-Wind hybrid system (0.52 kW + 1 kW), installed in Borlänge/Sweden is presented in this paper. The system performance was evaluated according the guidelines of the IEC 61724 standard. The parameters obtained allow a comparison with similar systems. The measurement data are also used to evaluate the sizing and operation of the hybrid system. In addition, the system was modelled in HOMER to study sizing options.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Participation as observer at the meeting of Task 14 of IEA's Solar Heating and Cooling Projects held in Hameln, Germany has led to greater understanding of interesting developments underway in several countries. This will be of use during the development of small scale systems suitable for Swedish conditions. A summary of the work carried out by the working groups within Task 14 is given, with emphasis on the Domestic Hot Water group. Experiences of low-flow systems from several countries are related, and the conclusion is drawn that the maximum theoretical possible increase in performance of 20% has not been achieved due to poor heat exchangers and poor stratification in the storage tanks. Positive developments in connecting tubes and pumps is noted. Further participation as observer in Task 14 meetings is desired, and is looked on favourably by the members of the group. Another conclusion is that SERC should carry on with work on Swedish storage tanks, with emphasis on better stratification and heat exchangers, and possible modelling of system components. Finally a German Do-it-Vourself kit is described and judged in comparison with prefabricated models and Swedish Do-it-Yourself kits.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Projektet omfattade en jämförelsestudie avseende stomsystem. Studien undersökte ramverk och fackverk/balk/pelar-system och genomfördes självständigt med stöttning av Ramböll AB´s kontor i Falun. Syftet var främst att undersöka vilka skillnader det finns mellan tvåledsramar och fackverk/balk/pelar-system för lätta hallbyggnader och försöka få klarhet i varför fackverk/balk/pelar-system är det dominerande systemet i Sverige eftersom övriga Europa har tagit en annan utveckling och domineras av tvåledsramar. Studien undersöker skillnaderna mellan systemen i en hallbyggnad med förutbestämda mått i stål.Inledningsvis gjordes en litteraturstudie för att få en bredare bakgrund av systemen och en bättre förståelse om förutsättningarna för varje system. Efter litteraturstudien kunde sedan ett typhus och beräkningsunderlag för jämförelsestudien tas fram. Även en enkätstudie gjordes med syftet att skapa en tydlig bild av vilket stomsystem konstruktörer i Sverige oftast väljer och varför. Resultatet av studien visade att tvåledsramar ger en ökad kostnad jämfört med fackverk/balk/pelar-system i materialåtgång och framställning samt att beräkningarna blir mer komplicerade. Skulle fortsatta studier göras med dessa system i byggnader med andra mått skulle det kanske gå att få fram speciella mått på byggnader där kostnaden för tvåledsramar blir densamma som för fackverk/balk/pelar-system och därför är ett likvärdigt alternativ som stomsystem.En viktig slutsats från projektet är att tvåledsramar används mycket mer sällan än fackverk/balk/pelar-system som stomsystem i lätta hallbyggnader i Sverige på grund av att kostnaderna blir mycket högre med tvåledsramar och att det är ett mer komplicerat system i beräkningsarbetet. De viktigaste slutsatserna från jämförelsestudien går att sammafatta som följande: Tvåledsramar är dyrare att använda. Tvåledsramar är ett mer komplicerat system beräkningsmässigt. Traditionen av att använda tvåledsramar finns inte och därför används inte systemet.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this article, the prevailing official view of supervision as a regulatory instrument is examined as it applies to the social services sector in Sweden. The study is based on a comparison of the views expressed on the design of supervision as a regulatory instrument by two government commissions, the Supervision Commission and the Commission on Supervision within the Social Services (UTIS), and on the positions taken by the Government regarding the definitions of the concept of supervision proposed by these commissions. The view of supervision as a regulatory instrument expressed in these policy documents is analysed with the help of a theoretical framework describing the components, their functions and the governance characteristics of control systems. In the framework separate interrelated characteristics of the components are identified and summarized into two models of control systems. The analysis shows that supervision in the Swedish social services sector can be described in terms of both a disciplinary and non-disciplinary system. By its system theoretical basis and the identification of interrelated characteristics the study contributes to a broadened understanding of the construction and functions of supervision as a regulatory instrument and of how supervision within the Swedish social sector is meant to be designed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Trafikverket, är den statliga verksamhet som har hand om alla Sveriges vägar och järnvägar har den så kallade nollvisionen som ett huvudmål. Tanken bakom nollvisionen är att de som använder vägarna skall vara säkra och inte komma till skada. En del av uppfyllandet av detta mål är att Trafikverket ger ut korttidsprognoser för väglag och körförhållande. I nuläget så används ett mycket manuellt systemet som heter NTIS, men man håller på att utveckla det nya automatiska systemet RCC som skall kunna ta fram korttidsprognoser baserat på olika former av data, t.ex. data från väderstationer. Syftet med denna studie är att utvärdera hur väl de två olika systemen utför en korttidsprognos och jämföra de mot varandra, samt verkligheten. Denna studie gjordes i form av en förklarande fallstudie. Som datainsamling används dokument i olika former och analysen var kvantitativ då resultatet av utvärdering ger olika procenttal av hur rätt respektive system har. Under undersökningen gång så kom vi fram till att båda systemen hade sina fördelar och nackdelar. T.ex. så det gamla NTIS systemet fortfarande bäst på isigt och moddigt väglag. Medans det nya RCC systemet hade sina egna fördelar, t.ex. snöigt väglag och vått väglag. Samt så hade RCC en klar fördel med sin rapporteringstid, vilket var ett problem man såg med NTIS. Resultat var som sagt ett procenttal av hur rätt de två olika systemen hade, men även förslag till förbättringar. T.ex. hur man skulle kunna ändra RCC regler för bättre resultat.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, dynamic simulation was used to compare the energy performance of three innovativeHVAC systems: (A) mechanical ventilation with heat recovery (MVHR) and micro heat pump, (B) exhaustventilation with exhaust air-to-water heat pump and ventilation radiators, and (C) exhaust ventilationwith air-to-water heat pump and ventilation radiators, to a reference system: (D) exhaust ventilation withair-to-water heat pump and panel radiators. System A was modelled in MATLAB Simulink and systems Band C in TRNSYS 17. The reference system was modelled in both tools, for comparison between the two.All systems were tested with a model of a renovated single family house for varying U-values, climates,infiltration and ventilation rates.It was found that A was the best system for lower heating demand, while for higher heating demandsystem B would be preferable. System C was better than the reference system, but not as good as A or B.The difference in energy consumption of the reference system was less than 2 kWh/(m2a) betweenSimulink and TRNSYS. This could be explained by the different ways of handling solar gains, but also bythe fact that the TRNSYS systems supplied slightly more than the ideal heating demand.