3 resultados para Connection admission control

em Dalarna University College Electronic Archive


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The main objective for this degree project was to analyze the Endpoint Security Solutions developed by Cisco, Microsoft and a third minor company solution represented by InfoExpress. The different solutions proposed are Cisco Network Admission Control, Microsoft Network Access Protection and InfoExpress CyberGatekeeper. An explanation of each solution functioning is proposed as well as an analysis of the differences between those solutions. This thesis work also proposes a tutorial for the installation of Cisco Network Admission Control for an easier implementation. The research was done by reading articles on the internet and by experimenting the Cisco Network Admission Control solution. My background knowledge about Cisco routing and ACL was also used. Based on the actual analysis done in this thesis, a conclusion was drawn that all existing solutions are not yet ready for large-scale use in corporate networks. Moreover all solutions are proprietary and incompatible. The future possible standard for Endpoint solution might be driven by Cisco and Microsoft and a rude competition begins between those two giants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

During last decades, the Internet teleobotics has been growing at an enormous ratedue to the rapid improvement of Internet technology. This paper presents theinternet-based remote control of mobile robot. To face unpredictable Internet delaysand possible connection rupture, a direct continuous control based teleoperationarchitecture with “Speed Limit Module” (SLM) and “Delay Approximator” (DA) isproposed. This direct continuous control architecture guarantees the path error of therobot motion is restricted within the path error tolerance of the application.Experiment results show the feasibility and effectiveness of this direct Internet controlarchitecture in the real Internet environment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper studies the influence of hydraulics and control of thermal storage in systems combined with solar thermal and heat pump for the production of warm water and space heating in dwellings. A reference air source heat pump system with flat plate collectors connected to a combistore was defined and modeled together with the IEA SHC Task 44 / HPP Annex 38 (T44A38) “Solar and Heat Pump Systems” boundary conditions of Strasbourg climate and SFH45 building. Three and four pipe connections as well as use of internal and external heat exchangers for DHW preparation were investigated as well as sensor height for charging of the DHW zone in the store. The temperature in this zone was varied to ensure the same DHW comfort was achieved in all cases. The results show that the four pipe connection results in 9% improvement in SPF compared to three pipe and that the external heat exchanger for DHW preparation leads to a 2% improvement compared to the reference case. Additionally the sensor height for charging the DHW zone of the store should not be too low, otherwise system performance is adversely affected