47 resultados para Refrigeration installation
em CentAUR: Central Archive University of Reading - UK
Resumo:
In his 1967 essay, “Art and Objecthood”, Michael Fried bemoaned the theatricality of minimalist sculpture, which replaced the presentness of compositional sculpture with the staging of an experience for the viewer as performer. His argument has since been inverted by artists and art writers invested in the idea of sculptures as props forming part of an artistic experience economy. This discourse has accompanied the rise of relational aesthetics as a dominant paradigm for contemporary art. More recently, however, there has been a turn away from relationality to ‘object-oriented’ art, where objects are seen to stage their own theatrical experiences, performing themselves without requiring the activation of a viewer’s body. We trace parallels between the philosophy of Bruno Latour and the “Speculative Materialism” group and this emerging trend in sculpture. In ascribing agency to objects, Latour proposes a radical shift from philosophy’s traditional investigation of the relationship between the mind and the world. Drawn to the idea that matter can be creative, artists have embraced his thinking. However, we argue that this has lead to a generalized, universalizing humanism that disables political action. Moreover, it undermines the potential for anti-humanist critique latent in object-oriented philosophy.
Resumo:
In this study, the performance, yield and characteristics of a 15 year old photovoltaic system installation has been investigated. The technology, BP Saturn modules which were steel-blue polycrystalline silicon cells are no longer in production. A bespoke monitoring system was designed and purpose built to monitor the characteristics of 6 strings, of 18 modules connected in series. The total output of the system is configured to 6.5kWp (series to parallel configuration). The PV system is demonstrating system outputs to be inferior by 0.7% per year. However,efficiency values in comparison to standard test conditions have remained practically the same. This output though very relevant to the possible performance and stability of aging cells, requires additional parametric studies to develop a more robust argument. The result presented in this paper is part of an on going investigation into PV system aging effects.
Resumo:
A combined windcatcher and light pipe (SunCatcher) was installed in the seminar room at the University of Reading, UK. Monitoring of indoor environment in real weather conditions was conducted to evaluate the application of windcatchers for natural ventilation. In addition, a subjective occupancy survey was undertaken. External weather conditions and internal indoor air quality indicators were recorded. The “tracer-gas decay” method using SF6 was used to establish air change rate for various conditions. The results indicated that the ventilation rate achieved through the windcatcher depends on the difference between internal and external air temperatures, and on wind speed and direction, in agreement with other published work in the area. The indoor air quality parameters were found to be within acceptable levels when the windcatcher was in operation. The measured air change rate was between 1.5ac/h and 6.8ac/h. Occupants’ questionnaires showed 75 per cent satisfaction with the internal conditions and welcomed the installation of the systems in UK buildings.
Resumo:
Many systems might have a long time dormant period, during which the systems are not operated. For example, most building services products are installed while a building is constructed, but they are not operated until the building is commissioned. Warranty terms for such products may cover the time starting from their installation times to the end of their warranty periods. Prior to the commissioning of the building, the building services products are protected by warranty although they are not operating. Developing optimal burn-in policies for such products is important when warranty cost is analysed. This paper considers two burn-in policies, which incur different burn-in costs, and have different burn-in effects on the products. A special case about the relationship between the failure rates of the products at the dormant state and at the operating state is presented. Numerical examples compare the mean total warranty costs of these two burn-in policies.
Resumo:
Constructing a building is a long process which can take several years. Most building services products are installed while a building is constructed, but they are not operated until the building is commissioned. The warranty term for the building service systems may cover the time starting from their installation to the end of the warranty period. Prior to the commissioning of the building, the building services systems are protected by warranty although they are not operated. The bum in time for such systems is important when warranty costs is analyzed. In this paper, warranty cost models for products with burn in periods are presented. Two burn in policies are developed to optimize the total mean warranty cost. A special case on the relationship between the failure rates of the product at the dormant state and at the I operating state is presented.
Resumo:
Most building services products are installed while a building is constructed, but they are not operated until the building is commissioned. The warranty of the products may cover the time starting from their installation to the end of the warranty period. Prior to the commissioning of the building, the products are at a dormant mode (i.e., not operated) but protected by the warranty. For such products, both the usage intensity and the failure patterns are different from those with continuous usage intensity and failure patterns. This paper develops warranty cost models for repairable products with a dormant mode from both the manufacturer's and buyer's perspectives. Relationships between the failure patterns at the dormant mode and at the operational mode are also discussed. Numerical examples and sensitivity analysis are used to demonstrate the applicability of the methodology derived in the paper.
Resumo:
The aim was to investigate (i) the occurrence of sublethal injury in Listeria monocytogenes, Escherichia coli, and Saccharomyces cerevisiae after high hydrostatic pressure (HHP) treatment as a function of the treatment medium pH and composition and (ii) the relationship between the occurrence of sublethal injury and the inactivating effect of a combination of HHP and two antimicrobial compounds, tert-butyl hydroquinone (TBHQ) and citral. The three microorganisms showed a high proportion of sublethally injured cells (up to 99.99% of the surviving population) after HHP. In E. coli and L. monocytogenes, the extent of inactivation and sublethal injury depended on the pH and the composition of the treatment medium, whereas in S. cerevisiae, inactivation and sublethal injury were independent of medium pH or composition under the conditions tested. TBHQ alone was not lethal to E. coli or L. monocytogenes but acted synergistically with HHP and 24-h refrigeration, resulting in a viability decrease of >5 log(10) cycles of both organisms. The antimicrobial effect of citral depended on the microorganism and the treatment medium pH. Acting alone for 24 h under refrigeration, 1,000 ppm of citral caused a reduction of 5 log(10) cycles of E. coli at pH 7.0 and almost 3 log(10) cycles of L. monocytogenes at pH 4.0. The combination of citral and HHP also showed a synergistic effect. Our results have confirmed that the detection of sublethal injury after HHP may contribute to the identification of those treatment conditions under which HHP may act synergistically with other preserving processes.
Resumo:
The potentials of applying the lactoperoxidase system (LPS) in extending the shelf life of raw milk at ambient temperatures was investigated in the western highlands of Cameroon. Raw milk was LPS-activated by adding various concentrations (ppm) of thiocyanate and peroxide and denoted as 0:0, 7:10 ppm, 10:10 ppm and 20:20 ppm. The keeping quality of the activated milk samples was assessed by the alcohol stability and clot-on-boiling tests, pH changes and titratable acidity. The milk in all the treatments remained fresh during the first 12 hours but the control was spoiled by the 15th hour. There was a continuous drop in pH values matched by a steady rise in titratable acidity. For all parameters measured, 20:20ppm was the last treatment to spoil, suggesting that the shelf life of milk increases with increasing concentrations of thiocyanate and peroxide. With small amounts of thiocyanate (20 ppm) and peroxide (20 ppm) the shelf life of raw milk can effectively be extended under Cameroonian conditions by approximately 9 hours without refrigeration. Thus LPS-activated milk can be stored for as long 21 hours, allowing sufficient time for its appropriate disposal.
Resumo:
The creation of Wireless Personal Area Networks (WPANs) offers the Consumer Electronics industry a mechanism to truly unwire consumer products, leading to portability and ease of installation as never seen before. WPAN's can offer data-rates exceeding those that are required to convey high quality broadcast video, thus users can easily connect to high quality video for multimedia presentations in education, libraries, advertising, or have a wireless connection at home. There have been many WPAN proposals, but this paper concentrates on ECMA-368 as this standard has the largest industrial and implementers' forum backing. This paper discusses the technology behind ECMA-368, the required numerical bandwidth, buffer memory requirements and implementation considerations while concentrating on supporting all the offered data-rates'.
Resumo:
The creation of Wireless Personal Area Networks (WPANs) offers the Consumer Electronics industry a mechanism to truly unwire consumer products, leading to portability and ease of installation as never seen before. WPAN's can offer data-rates exceeding those that are required to convey high quality broadcast video, thus users can easily connect to high quality video for multimedia presentations in education, libraries, advertising, or have a wireless connection at home. There have been many WPAN proposals, but this paper concentrates on ECMA-368 as this standard has the largest industrial and implementers' forum backing. With the aim to effective consumer electronic define and create cost equipment this paper discusses the technology behind ECMA-368 physical layer, the design freedom availabilities, the required processing, buffer memory requirements and implementation considerations while concentrating on supporting all the offered data-rates(1).
Resumo:
This paper assesses the potential for using building integrated photovoltaic (BIPV) roof shingles made from triple-junction amorphous silicon (3a-Si) for electrification and as a roofing material in tropical countries, such as Accra, Ghana. A model roof was constructed using triple-junction amorphous (3a-Si) PV on one section and conventional roofing tiles on the other. The performance of the PV module and tiles were measured, over a range of ambient temperatures and solar irradiance. PVSyst (a computer design software) was used to determine the most appropriate angle of tilt. It was observed that 3a-Si performs well in conditions such as Accra, because it is insensitive to high temperatures. Building integration gives security benefits, and reduces construction costs and embodied energy, compared to freestanding PV systems. Again, it serves as a means of protection from salt spray from the oceans and works well even when shaded. However, compared to conventional roofing materials, 3a-Si would increase the indoor temperature by 1-2 °C depending on the surface area of the roof covered with the PV modules. The results presented in this research enhance the understanding of varying factors involved in the selection of an appropriate method of PV installation to offset the short falls of the conventional roofing material in Ghana.
Resumo:
IPLV overall coefficient, presented by Air-Conditioning and Refrigeration Institute (ARI) of America, shows running/operation status of air-conditioning system host only. For overall operation coefficient, logical solution has not been developed, to reflect the whole air-conditioning system under part load. In this research undertaking, the running time proportions of air-conditioning systems under part load have been obtained through analysis on energy consumption data during practical operation in all public buildings in Chongqing. This was achieved by using analysis methods, based on the statistical energy consumption data distribution of public buildings month-by-month. Comparing with the weight number of IPLV, part load operation coefficient of air-conditioning system, based on this research, does not only show the status of system refrigerating host, but also reflects and calculate energy efficiency of the whole air-conditioning system. The coefficient results from the processing and analyzing of practical running data, shows the practical running status of area and building type (actual and objective) – not clear. The method is different from model analysis which gets IPLV weight number, in the sense that this method of coefficient results in both four equal proportions and also part load operation coefficient of air-conditioning system under any load rate as necessary.