35 resultados para PV modules

em CentAUR: Central Archive University of Reading - UK


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper assesses the potential for using building integrated photovoltaic (BIPV) roof shingles made from triple-junction amorphous silicon (3a-Si) for electrification and as a roofing material in tropical countries, such as Accra, Ghana. A model roof was constructed using triple-junction amorphous (3a-Si) PV on one section and conventional roofing tiles on the other. The performance of the PV module and tiles were measured, over a range of ambient temperatures and solar irradiance. PVSyst (a computer design software) was used to determine the most appropriate angle of tilt. It was observed that 3a-Si performs well in conditions such as Accra, because it is insensitive to high temperatures. Building integration gives security benefits, and reduces construction costs and embodied energy, compared to freestanding PV systems. Again, it serves as a means of protection from salt spray from the oceans and works well even when shaded. However, compared to conventional roofing materials, 3a-Si would increase the indoor temperature by 1-2 °C depending on the surface area of the roof covered with the PV modules. The results presented in this research enhance the understanding of varying factors involved in the selection of an appropriate method of PV installation to offset the short falls of the conventional roofing material in Ghana.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A ground source heat pump assisted by an array of photovoltaic (PV)-thermal modules was studied in this work. Extracting heat from an array of PV modules should improve the performance of both the PV cells and the heat pump. A series of computer simulations compare the performance of a ground source heat pump with a short ground circuit, used to provide space heating and domestic hot water at a house in southern England. The results indicate that extracting heat from an array of PV-thermal modules would improve the performance of a ground source heat pump with an undersized ground loop. Nevertheless, open air thermal collectors could be more effective, especially during winter. In one model more electricity was saved in ohmic heating than was generated by cooling the PV cells. Cooling the PV modules was found to increase their electrical output up to 4%, but much of the extra electricity was consumed by the cooling pumps.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study, the performance, yield and characteristics of a 15 year old photovoltaic system installation has been investigated. The technology, BP Saturn modules which were steel-blue polycrystalline silicon cells are no longer in production. A bespoke monitoring system was designed and purpose built to monitor the characteristics of 6 strings, of 18 modules connected in series. The total output of the system is configured to 6.5kWp (series to parallel configuration). The PV system is demonstrating system outputs to be inferior by 0.7% per year. However,efficiency values in comparison to standard test conditions have remained practically the same. This output though very relevant to the possible performance and stability of aging cells, requires additional parametric studies to develop a more robust argument. The result presented in this paper is part of an on going investigation into PV system aging effects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study, the performance, yield and characteristics of a 16 year old photovoltaic (PV) system installation have been investigated. The technology, BP Saturn modules which were steel-blue polycrystalline silicon cells are no longer in production. A bespoke monitoring system has been designed to monitor the characteristics of 6 refurbished strings, of 18 modules connected in series. The total output of the system is configured to 6.5 kWp (series to parallel configuration). In addition to experimental results, the performance ratio (PR) of known values was simulated using PVSyst, a simulation software package. From calculations using experimental values, the PV system showed approximately 10% inferior power outputs to what would have been expected as standard test conditions. However, efficiency values in comparison to standard test conditions and the performance ratio (w75% from PVSyst simulations) over the past decade have remained practically the same. This output though very relevant to the possible performance and stability of aging cells, requires additional parametric studies to develop a more robust argument. The result presented in this paper is part of an on-going investigation into PV system aging effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent numerical experiments have demonstrated that the state of the stratosphere has a dynamical impact on the state of the troposphere. To account for such an effect, a number of mechanisms have been proposed in the literature, all of which amount to a large-scale adjustment of the troposphere to potential vorticity (PV) anomalies in the stratosphere. This paper analyses whether a simple PV adjustment suffices to explain the actual dynamical response of the troposphere to the state of the stratosphere, the actual response being determined by ensembles of numerical experiments run with an atmospheric general-circulation model. For this purpose, a new PV inverter is developed. It is shown that the simple PV adjustment hypothesis is inadequate. PV anomalies in the stratosphere induce, by inversion, flow anomalies in the troposphere that do not coincide spatially with the tropospheric changes determined by the numerical experiments. Moreover, the tropospheric anomalies induced by PV inversion are on a larger scale than the changes found in the numerical experiments, which are linked to the Atlantic and Pacific storm-tracks. These findings imply that the impact of the stratospheric state on the troposphere is manifested through the impact on individual synoptic-scale systems and their self-organization in the storm-tracks. Changes in these weather systems in the troposphere are not merely synoptic-scale noise on a larger scale tropospheric response, but an integral part of the mechanism by which the state of the stratosphere impacts that of the troposphere.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the Eady model, where the meridional potential vorticity (PV) gradient is zero, perturbation energy growth can be partitioned cleanly into three mechanisms: (i) shear instability, (ii) resonance, and (iii) the Orr mechanism. Shear instability involves two-way interaction between Rossby edge waves on the ground and lid, resonance occurs as interior PV anomalies excite the edge waves, and the Orr mechanism involves only interior PV anomalies. These mechanisms have distinct implications for the structural and temporal linear evolution of perturbations. Here, a new framework is developed in which the same mechanisms can be distinguished for growth on basic states with nonzero interior PV gradients. It is further shown that the evolution from quite general initial conditions can be accurately described (peak error in perturbation total energy typically less than 10%) by a reduced system that involves only three Rossby wave components. Two of these are counterpropagating Rossby waves—that is, generalizations of the Rossby edge waves when the interior PV gradient is nonzero—whereas the other component depends on the structure of the initial condition and its PV is advected passively with the shear flow. In the cases considered, the three-component model outperforms approximate solutions based on truncating a modal or singular vector basis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Four races of Xanthomonas campestris pv. mal-vacearum (Xcm) viz. races 23, 27 and 32 (isolated from Gossypium hirsutum) and race 23b (from Gossypium barbadense) were studied. The plasmid profile of the natural isolates showed four plasmids in races 23 and 23b (ca. 60, 40, 23, 8.2 kb), five in race 27 (ca. 60, 40, 23, 8.2 and 3.7 kb) and six in race 32 (ca. 60, 40, 23, 8.2, 3.7 and 1.6 kb). Continuously sub-cultured laboratory isolates of the Xcm races resulted in the loss of all but two plasmids, ca. 60 and 40 kb in size. When the laboratory isolates were passed through cotton (Gossypium hirsutum), they regained certain plasmids so that four plasmids were found in race 23 and 23b (ca. 60, 40, 23 and 8.2 kb), five in race 27 (ca. 60, 40, 23, 8.2 and 3.7 kb) and six in race 32 (ca. 60, 40, 23, 8.2, 3.7 and 1.6 kb), which was more or less similar to the original isolates. The isolates recovered from cotton maintained their plasmid profile (except for minor changes in the miniplasmids) after storage for six months at -70degreesC in 50% glycerol. It is suggested that plasmid profiles among highly virulent races of Xcm are unstable during repeated sub-culturing at room temperature, resulting in rapid loss of some plasmids. However, when the cultures were sub-cultured and stored at -70degreesC the plasmid profile was fairly stable except for the miniplasmids (ca. 3.7 and 1.6 kb).

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador: