110 resultados para DOUBLE-IONIZATION
em CentAUR: Central Archive University of Reading - UK
Resumo:
Three double phenoxido-bridged dinuclear nickel(II) complexes, namely [Ni-2(L-1)(2)(NCS)(2)] (1), [Ni-2(L-2)(2)(NCS)(2)] (2), and [Ni-2(L-3)(2)(NCS)(2)] (3) have been synthesized using the reduced tridentate Schiff-base ligands 2-[1-(3-methylamino-propylamino)-ethyl]-phenol (HL1), 2-[1-(2-dimethylamino-ethylamino)-ethyl]-phenol (HL2), and 2-[1-(3-dimethylarnino-propylamino)-ethyl]-phenol (HL3), respectively. The coordination compounds have been characterized by X-ray structural analyses, magnetic-susceptibility measurements, and various spectroscopic methods. In all complexes, the nickel(II) ions are penta-coordinated in a square-pyramidal environment, which is severely distorted in the case of 1 (Addison parameter tau = 0.47) and 3 (tau = 0.29), while it is almost perfect for 2 (tau = 0.03). This arrangement leads to relatively strong antiferromagnetic interactions between the Ni(II) (S = 1) metal centers as mediated by double phenoxido bridges (with J values of -23.32 (1), -35.45 (2), and -34.02 (3) cm(3) K mol(-1), in the convention H = -2JS(1)S(2)). The catalytic activity of these Ni compounds has been investigated for the aerial oxidation of 3,5-di-tert-butylcatechol. Kinetic data analysis following Michaelis-Menten treatment reveals that the catecholase activity of the complexes is influenced by the flexibility of the ligand and also by the geometry around the metal ion. Electrospray ionization mass spectroscopy (ESI-MS) studies (in the positive mode) have been performed for all the coordination compounds in the presence of 3,5-DTBC to characterize potential complex-substrate intermediates. The mass-spectrometry data, corroborated by electron paramagnetic resonance (EPR) measurements, suggest that the metal centers are involved in the catecholase activity exhibited by the complexes.
Resumo:
A bipolar air conductivity instrument is described for use with a standard disposable meteorological radiosonde package. It is intended to provide electrical measurements at cloud boundaries, where the ratio of the bipolar air conductivities is affected by the presence of charged particles. The sensors are two identical Gerdien-type electrodes, which, through a voltage decay method, measure positive and negative air conductivities simultaneously. Voltage decay provides a thermally stable approach and a novel low current leakage electrometer switch is described which initiates the decay sequence. The radiosonde supplies power and telemetry, as well as measuring simultaneous meteorological data. A test flight using a tethered balloon determined positive (σ+) and negative (σ−) conductivities of σ+ = 2.77±0.2 fS m−1 and σ− = 2.82±0.2 fS m−1, respectively, at 400 m aloft, with σ+/σ− = 0.98±0.04.
Resumo:
Procedures for routine analysis of soil phosphorus (P) have been used for assessment of P status, distribution and P losses from cultivated mineral soils. No similar studies have been carried out on wetland peat soils. The objective was to compare extraction efficiency of ammonium lactate (PAL), sodium bicarbonate (P-Olsen), and double calcium lactate (P-DCaL) and P distribution in the soil profile of wetland peat soils. For this purpose, 34 samples of the 0-30, 30-60 and 60-90 cm layers were collected from peat soils in Germany, Israel, Poland, Slovenia, Sweden and the United Kingdom and analysed for P. Mean soil pH (CaCl2, 0.01 M) was 5.84, 5.51 and 5.47 in the 0-30, 30-60 and 60-90 cm layers, respectively. The P-DCaL was consistently about half the magnitude of either P-AL or P-Olsen. The efficiency of P extraction increased in the order P-DCaL < P-AL &LE; P-Olsen, with corresponding means (mg kg(-1)) for all soils (34 samples) of 15.32, 33.49 and 34.27 in 0-30 cm; 8.87, 17.30 and 21.46 in 30-60 cm; and 5.69, 14.00 and 21.40 in 60-90 cm. The means decreased with depth. When examining soils for each country separately, P-Olsen was relatively evenly distributed in the German, UK and Slovenian soils. P-Olsen was linearly correlated (r = 0.594, P = 0.0002) with pH, whereas the three P tests (except P-Olsen vs P-DCaL) significantly correlated with each other (P = 0.017850.0001). The strongest correlation (r = 0.617, P = 0.0001) was recorded for P-AL vs P-DCaL) and the two methods were inter-convertible using a regression equation: P-AL = -22.593 + 5.353 pH + 1.423 P-DCaL, R-2 = 0.550.
Resumo:
The creation of OFDM based Wireless Personal Area Networks (WPANs) has allowed the development of high bit-rate wireless communication devices suitable for streaming High Definition video between consumer products, as demonstrated in Wireless-USB and Wireless-HDMI. However, these devices need high frequency clock rates, particularly for the OFDM, FFT and symbol processing sections resulting in high silicon cost and high electrical power. The high clock rates make hardware prototyping difficult and verification is therefore very important but costly. Acknowledging that electrical power in wireless consumer devices is more critical than the number of implemented logic gates, this paper presents a Double Data Rate (DDR) architecture for implementation inside a OFDM baseband codec in order to reduce the high frequency clock rates by a complete factor of 2. The presented architecture has been implemented and tested for ECMA-368 (Wireless- USB context) resulting in a maximum clock rate of 264MHz instead of the expected 528MHz clock rate existing anywhere on the baseband codec die.
Resumo:
The creation of OFDM based Wireless Personal Area Networks (WPANs) has allowed high bit-rate wireless communication devices suitable for streaming High Definition video between consumer products as demonstrated in Wireless- USB. However, these devices need high clock rates, particularly for the OFDM sections resulting in high silicon cost and high electrical power. Acknowledging that electrical power in wireless consumer devices is more critical than the number of implemented logic gates, this paper presents a Double Data Rate (DDR) architecture to reduce the OFDM input and output clock rate by a factor of 2. The architecture has been implemented and tested for Wireless-USB (ECMA-368) resulting in a maximum clock of 264MHz instead of 528MHz existing anywhere on the die.
Resumo:
In this article we examine sources of technical efficiency for rice farming in Bangladesh. The motivation for the analysis is the need to close the rice yield gap to enable food security. We employ the DEA double bootstrap of Simar and Wilson (2007) to estimate and explain technical efficiency. This technique overcomes severe limitations inherent in using the two-stage DEA approach commonly employed in the efficiency literature. From a policy perspective our results show that potential efficiency gains to reduce the yield gap are greater than previously found. Statistically positive influences on technical efficiency are education, extension and credit, with age being a negative influence.
Resumo:
The paper provides one of the first applications of the double bootstrap procedure (Simar and Wilson 2007) in a two-stage estimation of the effect of environmental variables on non-parametric estimates of technical efficiency. This procedure enables consistent inference within models explaining efficiency scores, while simultaneously producing standard errors and confidence intervals for these efficiency scores. The application is to 88 livestock and 256 crop farms in the Czech Republic, split into individual and corporate.
Resumo:
The paper provides one of the first applications of the double bootstrap procedure (Simar and Wilson 2007) in a two-stage estimation of the effect of environmental variables on non-parametric estimates of technical efficiency. This procedure enables consistent inference within models explaining efficiency scores, while simultaneously producing standard errors and confidence intervals for these efficiency scores. The application is to 88 livestock and 256 crop farms in the Czech Republic, split into individual and corporate.
Resumo:
The double triangular test was introduced twenty years ago, and the purpose of this paper is to review applications that have been made since then. In fact, take-up of the method was rather slow until the late 1990s, but in recent years several clinical trial reports have been published describing its use in a wide range of therapeutic areas. The core of this paper is a detailed account of five trials that have been published since 2000 in which the method was applied to studies of pancreatic cancer, breast cancer, myocardial infarction, epilepsy and bedsores. Before those accounts are given, the method is described and the history behind its evolution is presented. The future potential of the method for sequential case-control and equivalence trials is also discussed. Copyright © 2004 John Wiley & Sons, Ltd.
Resumo:
It has become evident that the mystery of life will not be deciphered just by decoding its blueprint, the genetic code. In the life and biomedical sciences, research efforts are now shifting from pure gene analysis to the analysis of all biomolecules involved in the machinery of life. One area of these postgenomic research fields is proteomics. Although proteomics, which basically encompasses the analysis of proteins, is not a new concept, it is far from being a research field that can rely on routine and large-scale analyses. At the time the term proteomics was coined, a gold-rush mentality was created, promising vast and quick riches (i.e., solutions to the immensely complex questions of life and disease). Predictably, the reality has been quite different. The complexity of proteomes and the wide variations in the abundances and chemical properties of their constituents has rendered the use of systematic analytical approaches only partially successful, and biologically meaningful results have been slow to arrive. However, to learn more about how cells and, hence, life works, it is essential to understand the proteins and their complex interactions in their native environment. This is why proteomics will be an important part of the biomedical sciences for the foreseeable future. Therefore, any advances in providing the tools that make protein analysis a more routine and large-scale business, ideally using automated and rapid analytical procedures, are highly sought after. This review will provide some basics, thoughts and ideas on the exploitation of matrix-assisted laser desorption/ ionization in biological mass spectrometry - one of the most commonly used analytical tools in proteomics - for high-throughput analyses.
Resumo:
We have combined several key sample preparation steps for the use of a liquid matrix system to provide high analytical sensitivity in automated ultraviolet -- matrix-assisted laser desorption/ionisation -- mass spectrometry (UV-MALDI-MS). This new sample preparation protocol employs a matrix-mixture which is based on the glycerol matrix-mixture described by Sze et al. The low-femtomole sensitivity that is achievable with this new preparation protocol enables proteomic analysis of protein digests comparable to solid-state matrix systems. For automated data acquisition and analysis, the MALDI performance of this liquid matrix surpasses the conventional solid-state MALDI matrices. Besides the inherent general advantages of liquid samples for automated sample preparation and data acquisition the use of the presented liquid matrix significantly reduces the extent of unspecific ion signals in peptide mass fingerprints compared to typically used solid matrices, such as 2,5-dihydroxybenzoic acid (DHB) or alpha-cyano-hydroxycinnamic acid (CHCA). In particular, matrix and low-mass ion signals and ion signals resulting from cation adduct formation are dramatically reduced. Consequently, the confidence level of protein identification by peptide mass mapping of in-solution and in-gel digests is generally higher.
Resumo:
Flavonoid extracts derived from plant foods have been shown to benefit certain types of fluid retention. However, no studies have investigated these compounds for use in premenstrual fluid retention, a complaint common among women with otherwise normal menstrual cycles. Therefore, we conducted a double-blind, placebo-controlled, pilot study into the effect of a daily flavonoid extract (Colladeen(R), 320 mg oligomeric procyanidins) on premenstrual fluid retention. Fluid retention was assessed at baseline and throughout 4 menstrual cycles of the intervention using validated questionnaires. Leg girth was also measured at baseline and at the end of the study. Thirty subjects completed the study (n = 18 active treatment; n = 12 placebo). Although no significant changes in leg girth measurements were noted, there was a significant improvement in subjective "leg health" scores after flavonoid treatment compared to placebo (p = 0.013). Furthermore, this was accompanied by an improvement in reported premenstrual fluid retention nearing significance (p = 0.066). We conclude that flavonoids supplements may provide a new therapeutic direction to counter premenstrual fluid retention and improve leg health. A larger study is now warranted.
Resumo:
Objectives: This study aimed to investigate the efficacy of St. John's wort extract (SJW) as a treatment for premenstrual symptoms. Design: The study was a randomized, double-blinded, placebo-controlled trial, with two parallel treatment groups. After a no-treatment baseline cycle, volunteers were randomized to either SJW or placebo for a further two menstrual cycles. Settings/location: A postal trial conducted from The University of Reading, Berkshire, England. Subjects: One hundred and sixty-nine (169) normally menstruating women who experienced recurrent premenstrual symptoms were recruited onto the study. One hundred and twenty-five (125) completed the protocol and were included in the analysis. Interventions: Six hundred milligrams (600) mg of SJW (standardized to contain 1800 mug of hypericin) or placebo (containing lactose and cellulose). Outcome measure: A menstrual diary was used to assess changes in premenstrual symptoms. The anxiety-related subgroup of symptoms of this instrument was used as the primary outcome measure. Results: After averaging the effects of treatment over both treatment cycles it was found that there was a trend for SJW to be superior to placebo. However, this finding was not statistically significant. Conclusion: The possibility that this nonsignificant finding resulted from insufficient statistical power in the study, rather than a lack of efficacy of SJW, is discussed. Following this discussion the recommendation is made that, in future, similar studies should be powered to detect a minimum clinically relevant difference between treatments.
Resumo:
Electron impact ionization of dinitrogen pentoxide for incident electron energies up to about 25 eV has been investigated by use of a crossed beams quadrupole mass spectrometer system. The experiments reported in this paper detected the fragmentation products NO2+, NO+, O+, N+, and NO3+. No stable N2O5+ ion was observed. The NO3+ fragment, for which we determine an appearance energy 13.25 +/- 0.30 ev, has not been observed previously. This appearance energy is close to the calculated threshold.