65 resultados para Desorption


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The adsorption of L-alanine on Ni{111} has been studied as a 10 model of enantioselective heterogeneous catalysts. Synchrotron-based X-ray 11 photoelectron spectroscopy and near-edge X-ray absorption fine structure 12 (NEXAFS) spectroscopy were used to determine the chemical state, bond 13 coordination, and out-of-plane orientation of the molecule on the surface. 14 Alanine adsorbs in anionic and zwitterionic forms between 250 and ≈320 K. 15 NEXAFS spectra exhibit a strong angular dependence of the π* resonance 16 associated with the carboxylate group, which is compatible with two distinct 17 orientations with respect to the surface corresponding to the bidentate and 18 tridentate binding modes. Desorption and decomposition begin together at 19 ≈300 K, with decomposition occurring in a multistep process up to ≈450 K. Comparison with previous studies of amino acid 20 adsorption on metal surfaces shows that this is among the lowest decomposition temperatures found so far and lower than typical 21 temperatures used for hydrogenation reactions where modified Ni catalysts are used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The ‘soft’ ionization technique matrix-assisted laser desorption/ionization (MALDI) is without doubt one of the great success stories of modern mass spectrometry (MS). In particular, the further development of MALDI and in general ‘soft’ laser ionization, focusing on their unique characteristics and advantages in areas such as speed, spatial resolution, sample preparation and low spectral complexity, have led to great advances in mass spectral profiling and imaging with an extremely auspicious future in (bio)medical analyses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although liquid matrix-assisted laser desorption/ionization (MALDI) has been used in mass spectrometry (MS) since the early introduction of MALDI, its substantial lack of sensitivity compared to solid (crystalline) MALDI was for a long time a major hurdle to its analytical competitiveness. In the last decade, this situation has changed with the development of new sensitive liquid matrices, which are often based on a binary matrix acid/base system. Some of these matrices were inspired by the recent progress in ionic liquid research, while others were developed from revisiting previous liquid MALDI work as well as from a combination of these two approaches. As a result, two high-performing liquid matrix classes have been developed, the ionic liquid matrices (ILMs) and the liquid support matrices (LSMs), now allowing MS measurements at a sensitivity level that is very close to the level of solid MALDI and in some cases even surpasses it. This chapter provides some basic information on a selection of highly successful representatives of these new liquid matrices and describes in detail how they are made and applied in MALDI MS analysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Matrix-assisted laser desorption/ionisation (MALDI) coupled with time-of-flight (TOF) mass spectrometry (MS) is a powerful tool for the analysis of biological samples, and nanoflow high-performance liquid chromatography (nanoHPLC) is a useful separation technique for the analysis of complex proteomics samples. The off-line combination of MALDI and nanoHPLC has been extensively investigated and straightforward techniques have been developed, focussing particularly on automated MALDI sample preparation that yields sensitive and reproducible spectra. Normally conventional solid MALDI matrices such as α-cyano-4-hydroxycinnamic acid (CHCA) are used for sample preparation. However, they have limited usefulness in quantitative measurements and automated data acquisition because of the formation of heterogeneous crystals, resulting in highly variable ion yields and desorption/ ionization characteristics. Glycerol-based liquid support matrices (LSM) have been proposed as an alternative to the traditional solid matrices as they provide increased shot-to-shot reproducibility, leading to prolonged and stable ion signals and therefore better results. This chapter focuses on the integration of the liquid LSM MALDI matrices into the LC-MALDI MS/MS approach in identifying complex and large proteomes. The interface between LC and MALDI consists of a robotic spotter, which fractionates the eluent from the LC column into nanoliter volumes, and co-spots simultaneously the liquid matrix with the eluent fractions onto a MALDI target plate via sheath flow. The efficiency of this method is demonstrated through the analysis of trypsin digests of both bovine serum albumin (BSA) and Lactobacillus plantarum WCFS1 proteins.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Liquid matrix-assisted laser desorption/ionization (MALDI) allows the generation of predominantly multiply charged ions in atmospheric pressure (AP) MALDI ion sources for mass spectrometry (MS) analysis. The charge state distribution of the generated ions and the efficiency of the ion source in generating such ions crucially depend on the desolvation regime of the MALDI plume after desorption in the AP-tovacuum inlet. Both high temperature and a flow regime with increased residence time of the desorbed plume in the desolvation region promote the generation of multiply charged ions. Without such measures the application of an electric ion extraction field significantly increases the ion signal intensity of singly charged species while the detection of multiply charged species is less dependent on the extraction field. In general, optimization of high temperature application facilitates the predominant formation and detection of multiply charged compared to singly charged ion species. In this study an experimental setup and optimization strategy is described for liquid AP-MALDI MS which improves the ionization effi- ciency of selected ion species up to 14 times. In combination with ion mobility separation, the method allows the detection of multiply charged peptide and protein ions for analyte solution concentrations as low as 2 fmol/lL (0.5 lL, i.e. 1 fmol, deposited on the target) with very low sample consumption in the low nL-range.