5 resultados para Tubo Neural

em Universidad del Rosario, Colombia


Relevância:

60.00% 60.00%

Publicador:

Resumo:

 Introduction: the 5, 10-methylenetetrahydrofolate reductase (MTHFR) is an essential enzyme in folate metabolism; their polymorphisms have been associated with heart disease risk increase, obstetric problems, neural tube defects in fetuses and cancer susceptibility. This gene has a single nucleotide polymorphism, a C-T change at nucleotide 677, which affects significantly its enzymatic activity. Objective: because of the biological importance of this enzyme and the Colombian population genetic heterogeneity characteristic, a study was performed to determine allele and genotype frequencies of MTHFR C677T polymorphism in healthy individuals, taking into account that in Colombia there are only studies that have involved case-control methodology. Methods: we analyzed this polymorphism trough the amplification of the DNA of a 206 students sample population. Additionally, Colombian overall frequencies were calculated, using data from healthy controls reported in other studies. Results: a Hardy-Weinberg disequilibri m was found in the sample tested. For the Colombian data, we found that the global population was in equilibrium. Conclusion: T allele population frequency seems to be under positive selection pressure, which is reflected in the population allele increase, despite its deleterious effect. A Spanish study reported similar results and identified folic acid supplementation on expectant mothers as a probably cause of this change. 

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La selección apropiada del tamaño de los tubos endotraqueales (TET) para utilizar en niños es importante en anestesia general y cuidado crítico. Se han descrito muchos métodos para determinar el tamaño requerido del TET para cada paciente que son usados en la práctica clínica en la actualidad. La fórmula que considera la edad y las técnicas basadas en características físicas del niño han sido ampliamente utilizadas, pero tienen poco valor en predecir el tamaño del TET en pacientes entre 2 a 8 años. En este estudio analítico se correlacionaron las dimensiones anatómicas externas de la laringe (diámetros externos) con el tamaño del tubo endotraqueal (diámetro interno de la laringe) en 110 pacientes pediátricos llevados a cirugía electiva bajo anestesia general; se tomaron las medidas en la superficie externa de la laringe y se registró el tamaño del tubo endotraqueal que fue adecuado en cada niño, no se controló la técnica anestésica la cual fue elegida por el anestesiólogo a cargo. Se encontró correlación estadísticamente significativa entre las de la medida del diámetro externo del cartílago tiroides con el tamaño del tubo endotraqueal en pacientes de género femenino. Con estos datos es posible calcular el tamaño apropiado del tubo endotraqueal en estos pacientes diseñando una herramienta que permita mostrar el número del tubo a utilizar tomando como referencia la medición de este diámetro.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neural network methods have facilitated the unification of several unfortunate splits in psychology, including nature versus nurture. We review the contributions of this methodology and then discuss tentative network theories of caring behavior, of uncaring behavior, and of how the frontal lobes are involved in the choices between them. The implications of our theory are optimistic about the prospects of society to encourage the human potential for caring. 

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La presión que ejerce el manguito del tubo orotraqueal (TOT) sobre la mucosa al ser insuflado debe mantenerse en un rango de seguridad que evite complicaciones por sobreinflación o por desinsuflación. En nuestro medio, los instrumentos de medición objetiva no son de uso común. Objetivo: evaluar la concordancia de la presión del manguito del TOT estimada por palpación frente al uso de un manómetro manual en pacientes adultos sometidos a anestesia general. Materiales y métodos: se realizó un estudio de corte transversal que incluyó a 40 pacientes, a quienes, una vez intubados, dos anestesiólogos enmascarados, diferentes al que los intubó, palparon el manguito del TOT categorizándolo como sobreinflado, normal o desinflado; posteriormente, uno de los investigadores registró la medida con un manómetro en fase inspiratoria y espiratoria. Se consideró como rango normal de 20 a 30 cm H2O. Resultados: la concordancia de la estimación por palpación entre los dos anestesiólogos fue débil (Kappa = 0,21, ES: 0,11). La concordancia entre la estimación por palpación y la medición con el manómetro manual fue muy débil. Entre el primer anestesiólogo y el investigador en fase inspiratoria, . 0,08 (ES: 0,09), y en espiración, . 0,08 (ES: 0,07). Entre el segundo anestesiólogo y el investigador, . 0,05 (ES: 0,07) y 0,02 (ES: 0,06), respectivamente. Conclusión: el estudio muestra que la concordancia entre los métodos subjetivo y objetivo para determinar si el manguito del TOT está adecuadamente inflado fue débil. Se sugiere el empleo de métodos más objetivos para su determinación.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El objetivo de este estudio fue realizar una prueba de validez diagnostica del test neural 1 para el diagnóstico del Síndrome de Túnel del Carpo (STC) utilizando como prueba de referencia o de oro el test de conducción nerviosa. En este estudio participaron 115 sujetos, 230 manos con sospecha clínica de STC quienes fueron evaluados con el test de conducción nerviosa y el test neural 1. Se encontró una sensibilidad del 93.0% (IC 95%:88,21-96,79) y una especificidad del 6,67% (IC 95%:0,0-33,59), razón de verosimilitud positiva fue de 1,00 y razón de verosimilitud negativa de 1,05. Valor predictivo positivo de 86,9% y un valor predictivo negativo de 12,5%. Se concluye que el test neural 1 es una prueba clínica de alta sensibilidad y baja especificidad de gran utilidad para el monitoreo e identificación del STC. Es un procedimiento para el diagnóstico clínico de bajo costo que puede incluirse en los exámenes de rutina de los trabajadores como complemento a las pruebas clínicas sugeridas por las Gatiso para dar mayor precisión a la identificación temprana del STC. Se sugiere combinarla con otros test de mayor especificidad para ser aplicada en trabajadores en condiciones de riesgo o que presenten síntomas en miembros superiores y realizar otros estudios en donde participen sujetos sin diagnóstico clínico del STC.