2 resultados para Obstrução da Via Aérea

em Universidad del Rosario, Colombia


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: During the past years, alveolar recruitment maneuvers (RM) have produced growing interest due to their beneficial potential in pulmonary protection, and have been introduced in clinical practice. Objective: To describe and analyze the knowledge of MR and its application at seven intensive care units in the city of Cali, Colombia. Methods and materials: Descriptive Cross-Sectional Study with an intentional sample of 64 professionals working in seven intensive care units and who apply MR. The self-completed survey was made up of thirteen questions, and the application period was two months. Results: Out of 64 professionals surveyed, 77.8% of them follow a protocol guide; 54.7% employes during RM the ideal Positive end-expiratory pressure (PEEP), which maintains a saturation > 90% and a PaO2 > 60 mmHg; 42.1% tolerates airway pressures between 35 and 50 cmH2O; 48.4% perform RM with a progressive increase of the PEEP and a low tidal volume. Conclusions: Regarding the knowledge related to RM, heterogeneity was found in the answers. There is currently no consensus about which is the most effective and secure way to implement an MR. This study can be the starting point to create awareness towards the revision of knowledge, capacities and abilities that are required to perform RM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) have a impact on the respiratory system and the recommendations for mechanical ventilation of patients with IAH/ACS remain unclear. Our study characterize the influence of elevated intra-abdominal pressure (IAP) and positive end-expiratory pressure (PEEP) on airway plateau pressure (PPLAT) and bladder pressure (PBLAD). Methods: Nine (n=9) deeply anesthetized swine were mechanically ventilated via tracheostomy: volume-controlled mode at tidal volume = 10 ml/kg, frequency=15, Inspiratory:Expiratory ratio=1:2 and PEEP of 1 and 10 cmH2O (PEEP1 and PEEP10, respectively). A tracheostomy tube was place in the peritoneal cavity and different levels of IAP were applied utilizing a CPAP system. Measurements were performed during both PEEP1 and PEEP10. Results: PBLAD increased as experimental IAP rose. Minimal underestimation of IAP by PBLAD was observed. Applying PEEP10 did not significantly affect the correlation between experimental IAP and PBLAD. PBLAD (in cmH2O) was reflected by changes in PPLAT regardless of the PEEP.