12 resultados para Quality of Service,

em Cochin University of Science


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we study a k-out-of-n system with single server who provides service to external customers also. The system consists of two parts:(i) a main queue consisting of customers (failed components of the k-out-of-n system) and (ii) a pool (of finite capacity M) of external customers together with an orbit for external customers who find the pool full. An external customer who finds the pool full on arrival, joins the orbit with probability and with probability 1− leaves the system forever. An orbital customer, who finds the pool full, at an epoch of repeated attempt, returns to orbit with probability (< 1) and with probability 1 − leaves the system forever. We compute the steady state system size probability. Several performance measures are computed, numerical illustrations are provided.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

School of Industrial Fisheries, Cochin University of Science and Technology

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study focused on the quality of rainwater at various land use locations and its variations on interaction with various domestic rainwater harvesting systems.Sampling sites were selected based upon the land use pattern of the locations and were classified as rural, urban, industrial and sub urban. Rainwater samples were collected from the south west monsoon of May 2007 to north east monsoon of October 2008, from four sampling sites namely Kothamangalam, Emakulam, Eloor and Kalamassery, in Ernakulam district of the State of Kerala, which characterized typical rural, urban, industrial and suburban locations respectively. Rain water samples at various stages of harvesting were also collected. The samples were analyzed according to standard procedures and their physico-chemical and microbiological parameters were determined. The variations of the chemical composition of the rainwater collected were studied using statistical methods. It was observed that 17.5%, 30%, 45.8% and 12.1% of rainwater samples collected at rural, urban, industrial and suburban locations respectively had pH less than 5.6, which is considered as the pH of cloud water at equilibrium with atmospheric CO,.Nearly 46% of the rainwater samples were in acidic range in the industrial location while it was only 17% in the rural location. Multivariate statistical analysls was done using Principal Component Analysis, and the sources that inf1uence the composition of rainwater at each locations were identified .which clearly indicated that the quality of rain water is site specific and represents the atmospheric characteristics of the free fall The quality of harvested rainwater showed significant variations at different stages of harvesting due to deposition of dust from the roof catchment surface, leaching of cement constituents etc. Except the micro biological quality, the harvested rainwater satisfied the Indian Standard guide lines for drinking water. Studies conducted on the leaching of cement constituents in water concluded that tanks made with ordinary portland cement and portland pozzolana cement could be safely used for storage of rain water.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis entitled' On Queues with Interruptions and Repeat or Resumption of Service' introduces several new concepts into queues with service interruption. It is divided into Seven chapters including an introductory chapter. The following are keywords that we use in this thesis: Phase type (PH) distribution, Markovian Arrival Process (MAP), Geometric Distribution, Service Interruption, First in First out (FIFO), threshold random variable and Super threshold random variable. In the second chapter we introduce a new concept called the 'threshold random variable' which competes with interruption time to decide whether to repeat or resume the interrupted service after removal of interruptions. This notion generalizes the work reported so far in queues with service interruptions. In chapter 3 we introduce the concept of what is called 'Super threshold clock' (a random variable) which keeps track of the total interruption time of a customer during his service except when it is realized before completion of interruption in some cases to be discussed in this thesis and in other cases it exactly measures the duration of all interruptions put together. The Super threshold clock is OIl whenever the service is interrupted and is deactivated when service is rendered. Throughout this thesis the first in first out service discipline is followed except for priority queues.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives of the present study are to find out the proximate composition of 20 commercially important tropical fish species on the west coast of India. To determine the collagen content in these commercially important fish species and fractionation of collagen into acid soluble collagen (ASC) and hot water soluble (insoluble) collagen (ISC). To classify fishes according to its collagen content and To study the different storage characteristics in the mince based product—surimi, from different species of fishes. The researcher tries to find out a suitable collagen source to incorporate in surimi. and studies the different storage qualities in the mince based product, surimi at different levels of collagen in different species of fishes. The optimum collagen level to get desirable texture and storage quality for mince based product. The researcher aims to develop some products from surimi with desirable level of collagen. And compare the products prepared from surimi of lesser collagen content fish containing desirable level of collagen with surimi prepared with high collagen content fish without collagen. This study gains in importance as there is littleinformation on the collagen content of different species of fishes in India. So far no attempt was made to classify fishes according to its collagen content.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Condoms are widely accepted as a contraceptive for family planning and population control. It is also accepted as the most effective barrier against sexually transmitted diseases, especially AIDS, the incurable disease. But presence of pinholes and low film strength of condoms make it unsuitable for the purpose. Quality improvement of condoms by reducing the pinhole formation and increasing the film strength is thus an essential requirement for population control as well as for preventing the spread of sexually transmitted diseases. Strict implementation of WHO specification of condoms further increases the rejection percentage. This causes higher rejection loss to condom manufacturers because the defects could be identified only at the final stage of processing. If the influence of various factors which cause these defects is known, manufacturers can take remedial measures to reduce the defectives so that rejection loss can be decreased and quality of condoms increased. In the present study, it was proposed to conduct experiments to improve the quality of condoms by reducing the pinhole rejection percentage and increasing the tensile properties, burst volume, and burst pressure. Ageing property improvement also was an important target among other parameters. Until a cure for AIDS is found, a high quality latex condom is the only effective device in the prevention of the spread of HIV, AIDS and STD's. Hence it is all the more necessary to have high quality condoms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study aims at the investigation of the 1ysico—chemical features of a tropical tidal river viz. we Muvattupuzha river. This river is expected to receive Jderate to heavy pollution loads in years to come, from we lone industrial unit, already set up on its bank. ilike other rivers, the geographical disposition of this Lver attains unique importance as regards its dynamics for 3) availability of natural runoff water from catchment :eas, which becomes very heavy during the monsoon season 3) regular steady availability of tail race water from a /dro—electric power station throughout the yearThe study also aims at arriving at the balancing forces of inherent self~purification of the river verses pollution loads from the factory effluents. The investigation period falls ahead of actual pollution occurrence and so the ambient conditions for a period of nearly one-and-a—half years were investigated, the analyses of which providflz to formulate the inter-relations of parameters varying with seasons. Tracer experiments were carried out which revealed the dispersion and dilution characteristics of the river in the vicinity of effluent outfall. The studv covers the trial—cum-capacity production periods of the factory during which effluents of various strength and quantity were discharged into the river; a few computed values arQ’cjmpgrQdl ... with the observed values. The base data along with the profiles of Oxygen sag equation have been utilized fb develop a mathematical model of the river with regard to its water quality

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One thousand, two hundred and sixty four samples of individually quick-frozen (IQF) peeled and deveined raw and 914 samples of cooked ready to eat shrimp samples produced from farm raised black tiger (Penaeus monodon) obtained from a seafood unit working under HACCP concept were analysed for total aerobic plate count (APC), coliform count, Escherichia coli, coagulase positive Staphylococci and Salmonella. The overall bacteriological quality of the product was found to be good. Of the frozen raw shrimp, 96% of samples showed APC below 105 while 99% of the frozen cooked ready-to-eat samples showed APC less than 104. The APC ranged from 1·0´102 to 4·2´106 cfu/gm in frozen raw shrimp and from 1·0´102 to 6·4´104 cfu/gm in the frozen cooked shrimp. Prevalences of coliforms in raw shrimp and cooked shrimp samples were 14·4% and 2·9% respectively. The coliform count in raw products ranged from 1·0´101 to 2·5´103 cfu/gm and in the cooked products, from 1·0 ´101 to 1·8´102 cfu/gm. Although all the cooked shrimp samples were free of coagulase positive staphylococci, E. coli and Salmonella, 1·0, 2·0 and 0·1% of the frozen raw shrimp samples tested positive for coagulase positive Staphylococci, E. coli and Salmonella respectively. The Salmonella strain was identified as Salmonella typhimurium. The results of the present study highlight the importance of implementation of HACCP system in the seafood industry to ensure consistent quality of frozen seafood

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bacteriological quality of individually quick frozen (IQF) shrimp products produced from aquacultured tiger shrimp (Penaeus monodon) has been analysed in terms of aerobic plate count (APC), coliforms, Escherichia coli, coagulase-positive staphylococci, Salmonella, and Listeria monocytogenes. Eight hundred forty-six samples of raw, peeled, and deveined tail-on (RPTO), 928 samples of cooked, peeled, and deveined tail-on (CPTO), 295 samples of headless, undeveined shell-on (HLSO), and 141 samples of raw, peeled, and deveined tail-off (RPND) shrimps were analysed for the above bacteriological parameters. Salmonella was isolated in only one sample of raw, peeled tail-on. Serotyping of the strain revealed that it was S. typhimurium. While none of the cooked, peeled tail-on shrimp samples exceeded the aerobic plate count (APC) of 105 colony forming units per gram (cfu/g), 2.5% of raw, peeled, tail-on, 6.4% of raw, peeled tail-off, and 7.5% of headless shell-on shrimp samples exceeded that level. Coliforms were detected in all the products, though at a low level. Prevalence of coliforms was higher in headless shell-on (26%) shrimps followed by raw, peeled, and deveined tail-off (19%), raw, peeled tail-on (10%), and cooked, peeled tail-on (3.8%) shrimps. While none of the cooked, peeled tail-on shrimp samples were positive for coagulase-positive staphylococci and E. coli, 0.6–1.3% of the raw, peeled tail-on were positive for staphylococci and E. coli, respectively. Prevalence of staphylococci was highest in raw, peeled tail-off (5%) shrimps and the highest prevalence of E. coli (4.8%) was noticed in headless shell-on shrimps. L. monocytogenes was not detected in any of the cooked, peeled tail-on shrimps. Overall results revealed that the plant under investigation had exerted good process control in order to maintain superior bacteriological quality of their products

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Effect of delayed icing on the microbial quality and shelf-life of Hilsa toll was studied . Fish iced in rigor condition had a shelf-life of 11 days irrespective of the state of rigor . Fish procured from the landing centre had a shelf-life of only 8 days . It showed the presence of coagulase positive staphylococci, faecal streptococci and E. coli. Total bacterial count was low in all the samples and it increased after spoilage