27 resultados para Cholesterol Determination
Resumo:
The authors apply the theory of photothermal lens formation and also that of pure optical nonlinearity to account for the phase modulation in a beam as it traverses a nonlinear medium. It is used to simultaneously determine the nonlinear optical refraction and the thermo-optic coefficient. They demonstrate this technique using some metal phthalocyanines dissolved in dimethyl sulfoxide, irradiated by a Q-switched Nd:YAG laser with 10 Hz repetition rate and a pulse width of 8 ns. The mechanism for reverse saturable absorption in these materials is also discussed.
Resumo:
Irradiation of a Polymethyl methacrylate target using a pulsed Nd-YAG laser causes plasma formation in the vicinity of the target. The refractive index gradient due to the presence of the plasma is probed using phase-shift detection technique. The phase-shift technique is a simple but sensitive technique for the determination of laser ablation threshold of solids. The number density of laser generated plasma above the ablation threshold from Polymethyl methacrylate is calculated as a function of laser fluence. The number density varies from 2×1016 cm-3 to 2×1017 cm-3 in the fluence interval 2.8-13 J · cm-2.
Resumo:
Pulsed photoacoustic technique which is found to be a very convenient and accurate method, is used for the determination of absolute fluorescence quantum yield of laser dye rhodamine B. Concentration and power dependence of quantum yield of rhodamine B in methanol for excitation at 532 nm is reported here. Results show that a rapid decrease in quantum yield as the concentration is increased and finally it reaches the limit corresponding to fluorescence quenching.
Resumo:
Photothermal deflection technique was used for determining the laser damage threshold of polymer samples of teflon (PTFE) and nylon. The experiment was conducted using a Q-switched Nd-YAG laser operating at its fundamental wavelength (1-06μm, pulse width 10 nS FWHM) as irradiation source and a He-Ne laser as the probe beam, along with a position sensitive detector. The damage threshold values determined by photothermal deflection method were in good agreement with those determined by other methods.
Resumo:
In many fields such as earth science biology, environment and electronics, the knowledge about elemental distributions and chemical speciation is important. The determination of metal levels especially the toxic ones both in the environment and in biological materials are increasingly demanded by the society.Ion selective sensors have become one of the most effective ad powerful means for analytical scientists for the trace level monitoring of metal ions. The wide range of applications ,low material requirements and simplicity of analytical procedure have not only brought ion-selective electrodes in to the lime light of analytical chemistry,but have promoted their use as tools for physiologists,medical researchers,biologists,geologists,environmental protection specialists etc.Potentiometric ion-selective sensors have been developed for the determination of lanthanide ions such as La3+,Nd3+,Pr3+,Sm3+, and Gd3+.The sensors fabricated include both PVC membrane sensor and chemically modified carbon paste sensor. A set of 10 sensors have been developed. The response parameters of all the sensors have been studied and the sensors were applied as an indicator electrode in the potentiometric titration and for the determination of metal ions in real samples.
Resumo:
The quality of a drug is determined after establishing its authenticity by testing its purity and quality of the pure substance in the drug and its formulations.Ion selective sensors have become one of the most effective and powerful means for analytical scientists in the determination of drug substances and are playing an increasing role in pharmaceutical analysis.ISEs are cost effective,easy to prepare and can be rapidly manipulated . Potentiometric ion selective sensors have been developed for six drugs namely trimethoprim, ketoconazole, lamivudine, domperidon, nimesulide and Lomefloxacin. The sensors fabricated include both PVC membrane sensor as well as carbon paste sensor. A total of sixteen different sensors have been developed. The response parameters of all the sensors have been studied and the sensors were applied to the determination of the drugs in pharmaceutical formulations and also in real samples like urine.
Resumo:
With a seacoast of 8,1 18 km, an exclusive economic zone (EEZ) of 2 million square km, and with an area of about 30,000 square km under aquaculture, lndia produces close to six million tonnes of fish, over 4 per cent of the world fish production. While the marine waters upto 50m depth have been fully exploited, those beyond, remain unexplored. There is an ever increasing demand for fishery resources as food. The coastal fishery resources of the country are dwindling at a rapid pace and it becomes highly imperative that we search for alternate fishery resources for food. The option we have is to hunt for marine fishery resources. Studies pertaining to proximate composition, amino acid and fatty acid composition are essential to understand the nutraceutical values of these deep sea fishery resources. The present study was aimed to carry out proximate composition of deep sea fishery resources obtained during cruises onboard the FORV Sarise Sampada, to identify fishery resources which have appreciable lipid content and thereby analyse the bioactive potentials of marine lipids, to study the amino acid profile of these fishery resources, to understand the contents of SPA, MUFA and PUFA and to calculate the n3/n6 fatty acid contents. Though the presence of nutraceuticals was identified in the marine fishery resources their use as potential food resources deserve further investigation. So the study were carried out to calculate the hepatosomatic indices of sharks & chimaeras and conduct biochemical characterisation of liver oils of Apristurus indicus, Cenlrophorus scalprams, Centroselachus crepidater, Neoharriotta raleighana, and Harriotta pinnata obtained during cruises onboard the FORV Sugar Sampada.Therapeutic use of shark liver oil is evident from its use for centuries as a remedy to heal wounds and fight flu (Neil er al. 2006). Japanese seamen called it 'samedava' or "cure all". Shark liver oil is being promoted worldwide as a dietary supplement to boost the immune system, fight infections, to treat cancer and to lessen the side effects of conventional cancer treatment. These days more emphasis is laid on the nutritive benefits of shark liver oils especially on the omega 3 polyunsaturated fatty acids ( PUFAs) (Anandan er al. 2007) and alkylglycerols (AKGs) (Pugliese er al. I998) contained in them due to the high rise of inflammatory disorders such as arthritis, asthma and neurodegenerative diseases like Alzheimer’s, Parkinson’s and Schizophrenia. So the present study also evaluate the pharmacological properties with respect to analgesic, anti-inflammatory, anti pyretic and anti-ulcer effects of four different liver oils of sharks belonging to the Indian EEZ and to identify the components of oil responsible for these activities.The analgesic and anti-inflammatory activities of liver oils from Neoharriotra raleighana (NR), Centrosymnus crepidater (CC), Apristurus indicus (AI), and Centrophorus sculpratus (CS) sharks caught from the Arabian Sea and the Indian Ocean were compared. The main objectives also include determination of the cholesterol lowering effects of liver oils of Neoharriotra raleighana (NR) and Centrophorus sculpratus (CS) on the high fat diet induced dyslipidemia and to compare the impact of four isolipidemic diets, on levels of serum diagnostic marker enzymes, on lipid profile of blood and liver and antioxidant status of heart in male Albino rats. And also to study the efficacy of Centrophorus sculpratus (CS) liver oil against Complete Freund’s Adjuvant-induced arthritis and to compare the anti-inflammatory activity of this oil with a traditionally used anti-inflammatory substance gingerol (oleoresin extracted from ginger.). The results of the present study indicated that both (Centrophorus sculpratus liver oils as well as gingerol extracts proved to be effective natural remedies against CFA-induced arthritis in Albino rats.
Resumo:
Electrochemical sensors are increasingly being investigated to perform measurements for single or multiple analytes. Demanded by modern medical diagnosis, advances in microfabrication technology have led to the development of fast, sensitive and selective electrochemical sensors for drug analysis. Electrochemical sensors for the measurement of analytes of interest in clinical chemistry are ideally suited for these applications, due to their high sensitivity and selectivity, simple-to-operate, rapid response time and low-cost. As part of the present investigations eight voltammetric sensors have been fabricated for six drugs such as PAM Chloride, Tamsulosin Hydrochloride, Hesperidin Methyl Chalcone, Guaiphenesin, Cephalexin and Amoxicillin trihydrate. The modification techniques adopted as part of the present work include multiwalled carbon nanotube (MWNT) based modifications, electropolymerization, gold nanoparticle (AuNP) based modifications and platinum nanoparticle (PtNP) based modifications. The thesis is divided into nine chapters
Resumo:
The present study focuses on vibrios especially Vibrio harveyi isolated from shrimp (P. monodon) larval production systems from both east and west coasts during times of mortality. A comprehensive approach has been made to work out their systematics through numerical taxonomy and group them based on RAPD profiling and to segregate the virulent from non- virulent isolates based on the presence of virulent genes as well as their phenotypic expression. The information gathered has helped to develop a simple scheme of identification based on phenotypic characters and segregate the virulent from non virulent strains of V. harveyi.
Resumo:
The fabrication and electrochemical response characteristics of two novel potentiometric sensors for the selective determination of domperidone (DOM) are described. The two fabricated sensors incorporate DOM–PTA (phosphotungstic acid) ion pair as the electroactive material. The sensors include a PVC membrane sensor and a carbon paste sensor. The sensors showed a linear, stable, and near Nernstian slope of 56.5 and 57.8 mV/decade for PVC membrane and carbon paste sensors, respectively over a relatively wide range of DOM concentration (1.0 9 10-1–1.0 9 10-5 and 1.0 9 10-1–3.55 9 10-6 M). The response time of DOM–PTA membrane sensor was less than 25 s and that in the case of carbon paste sensor was less than 20 s.Auseful pH range of 4–6 was obtained for both types of sensors. A detection limit of 7.36 9 10-5 M was obtained for PVC membrane sensor and 1.0 9 10-6 M was obtained for carbon paste sensor. The proposed sensors showed very good selectivity toDOMin the presence of a large number of other interfering ions. The analytical application of the developed sensors in the determination of the drug in pharmaceutical formulations such as tablets was investigated. The results obtained are in good agreement with the values obtained by the standard method. The sensors were also applied for the determination ofDOMin real samples such as urine by the standard addition method.
Resumo:
The carrier transport mechanism of polyaniline (PA) thin films prepared by radio frequency plasma polymerization is described in this paper. The mechanism of electrical conduction and carrier mobility of PA thin films for different temperatures were examined using the aluminium–PA–aluminium (Al–PA–Al) structure. It is found that the mechanism of carrier transport in these thin films is space charge limited conduction. J –V studies on an asymmetric electrode configuration using indium tin oxide (ITO) as the base electrode and Al as the upper electrode (ITO–PA–Al structure) show a diode-like behaviour with a considerable rectification ratio
Resumo:
Cochin University of Science & Technology