3 resultados para small angle X-ray analysis

em Brock University, Canada


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gramicidin is an antibiotic peptide that can be incorporated into the monolayers of cell membranes. Dimerization through hydrogen bonding between gramicidin monomers in opposing leaflets of the membrane results in the formation of an iontophoretic channel. Surrounding phospholipids, with various associated mechanical properties, have been shown to influence the gating properties of this channel. Conversely, gramicidin incorporation has been shown to affect the structure of spontaneously formed lipid assemblies. Using small-angle x-ray diffraction and model systems composed of phospholipids and gramicidin, the physical effects incurred by gramicidin incorporation were measured. The reverse hexagonal (H^) phase composed of dioleoylphosphatidylethanolamine (DOPE) monolayers decreased in lattice dimension with increasing incorporation of gramicidin. This indicated that gramicidin was adding negative curvature to the monolayers. In this system, gramicidin was measured to have an apparent intrinsic radius of curvature (Rop*™") of -7. 1 A. The addition of up to 4 mol% gramicidin in mixtures with DOPE did not result in the monolayers becoming stiffer, as indicated by unaltered bending moduli for each composition. Dioleoylphosphatidylcholine (DOPC) alone forms the lamellar (LJ phase when hydrated, but undergoes a transition into the H^ phase when mixed with gramicidin. The lattice repeat dimension decreases systematically with increased gramicidin content. Again, this indicated that gramicidin was adding negative curvature to the monolayers. At 12 mol% gramicidin in mixtures with DOPC, the apparent radius of intrinsic curvature of gramicidin (Rop*"^) was measured to be -7.4 A. This mixture formed monolayers that were very resistant to bending under osmotic pressure, with a measured bending modulus of 1 15 kT. The measurements made in this study demonstrate that peptides are able to modulate the spontaneous curvature and other mechanical properties of phospholipid assemblies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method is presented for determining the composition of thin films containing the elements Bi, Sr, Br, Cu, and Ca. Quantitative x-ray fluorescence (XRF) consisting of radioactive sources (secondary foil excitor 241Am-Mo source and 55Pe source), a Si(Li) detector, and a multichannel analyzer were employed. The XRF system was calibrated by using sol gel thin films of known element composition and also by sputtered thin films analyzed by the conventional Rutherford Back Scattering (RBS). The XRF system has been used to assist and optimize the sputter target composition required to produce high-Tc BiSrCaCuO films with the desired metal composition.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using the energy dispersive x ...ray diffraction (EDXD) technique, the room temperature diffraction pattern of Al powder was obtained at diffraction angles ~ 30° and 50°. From the small angle diffraction pattern the average relative intensities (IR) of the (111), (200), and (220) lines were measured to be equal to 100, 62, and 32 respectively. From the large diffraction angle IR for the (220), (311+222), (400), (331+420), and (422) lines were measured to be 100,201,17,90, and 19.5 respectively. The diffraction pattern at those two angles were obtained at several higher temperatures to measure the change in the intensities of the Al lines. From the intensity changes the increase of the Debye- Waller temperature factor, i.e ~B(T), with respect to the value at room temperature was determined to be 0.6+0.1 at 250°C, 1.10+0.15 at 350°C, 1.45+0.20 at 450°C, and 2.20±0.35 at 550°C.