3 resultados para Polyvinyl chloride.

em Brock University, Canada


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Sediment samples were taken from seven locations in the WeIland River in December 1986 and April 1987. The DMSO extracts of these sediment samples showed a significant (ppolyvinyl chloride plant's discharge pipe (station D-l) . It was concluded that genotoxic contaminants were associated with the sediments from this l ocation. Analysis of sediment samples from the nearby station D-2 resulted in a significant (p <0 . 05) positive genotoxic response in December but not in April. Chironomids (midge larvae) taken from each of seven study locations were analyzed for the frequency of chironomid labial plate deformities (over 1000 individual specimens were observed) . The samples from station D-l showed the highest frequency of chironomid labial plate deformities (10 . 9% ± 3.2%), while samples from the upstream control (station A) displayed t,he lowest frequency of deformities (3.8% ± 1.3%). All samples were coded to avoid unconscious biases . The results of the genotoxicity study indicated that station D-l in the WeIland River was contaminated with genotoxic materials. The genotoxic materials may have induced the observed increased frequency in chironomid labial plate deformities . Samples from stations C and D-l, located in a downstream portion of the river bounded by an industrialized area were slightly toxic according to -the alkaline phosphatase inhib_ii~ion component of the 50S chromotest analyses. The toxicity of these samples was only evident once they had been activated by the 59 (liver extract) mixture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Flow injection analysis (FIA) was applied to the determination of both chloride ion and mercury in water. Conventional FIA was employed for the chloride study. Investigations of the Fe3 +/Hg(SCN)2/CI-,450 nm spectrophotometric system for chloride determination led to the discovery of an absorbance in the 250-260 nm region when Hg(SCN)2 and CI- are combined in solution, in the absence of iron(III). Employing an in-house FIA system, absorbance observed at 254 nm exhibited a linear relation from essentially 0 - 2000 Jlg ml- 1 injected chloride. This linear range spanning three orders of magnitude is superior to the Fe3+/Hg(SCN)2/CI- system currently employed by laboratories worldwide. The detection limit obtainable with the proposed method was determin~d to be 0.16 Jlg ml- 1 and the relative standard deviation was determined to be 3.5 % over the concentration range of 0-200 Jig ml- 1. Other halogen ions were found to interfere with chloride determination at 254 nm whereas cations did not interfere. This system was successfully applied to the determination of chloride ion in laboratory water. Sequential injection (SI)-FIA was employed for mercury determination in water with the PSA Galahad mercury amalgamation, and Merlin mercury fluorescence detection systems. Initial mercury in air determinations involved injections of mercury saturated air directly into the Galahad whereas mercury in water determinations involved solution delivery via peristaltic pump to a gas/liquid separator, after reduction by stannous chloride. A series of changes were made to the internal hardware and valving systems of the Galahad mercury preconcentrator. Sequential injection solution delivery replaced the continuous peristaltic pump system and computer control was implemented to control and integrate all aspects of solution delivery, sample preconcentration and signal processing. Detection limits currently obtainable with this system are 0.1 ng ml-1 HgO.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Please consult the paper edition of this thesis to read. It is available on the 5th Floor of the Library at Call Number: Z 9999 C54 L434 1989